1 |
The Development of an Improved Milk Substrate for Rennet Coagulation Assay on an Automatic Clot- TimerStevens, Mark Brimhall 01 May 1973 (has links)
A substrate was developed for measuring the milk clotting strength of rennet preparations on an automatic clot-timer . The substrate contained 8 percent pasteurized skim milk solids, 1 percent chloroform, 0.3 percent 200 bloom gelatin, 0.03 M added CaCl2 and was buffered to pH 6.6 with 0.057 M cacodylic acid and 0.042 M triethanolamine. The substrate was shelf-stable for 18 days at room temperatures. It was found that rennet preparations could be standardized to within 1 percent of each other, in terms of milk clotting strength, by use of the substrate on the automatic clot-timer. The method appears to have advantages over conventional rennet standardizing procedures. The research included studies on the effect of chloroform, nonfat dry milk and CaCl2 concentrations; heat and ionizing radiation on the substrate coagulation time.
|
2 |
Local Delivery of Bisphosphonates from FibMat MatrixAronsson, Henrik January 2008 (has links)
Improving the functionality and reducing revision rates are important driving forces in the development of orthopaedic implants. FibMat is a fibrinogen based matrix developed towards commercialisation by the company Optovent AB. This matrix can be coated on implants and act as a local drug delivery system for bisphosphonates (BPs). BPs are drugs inhibiting bone resorption, and applied with FibMat to improve stability of implants in bone, e.g. when fixing bone fractures. In this thesis, FibMat loaded with BP (FibMat/BP) was coated on stainless-steel screws and titanium screws in order to investigate some technology properties relevant to its clinical applicability. Bone-mimicking materials were used to study scrape-off effect upon insertion. The coagulation properties of fibrinogen as well as the structural properties of BPs were studied after exposure to gamma radiation. The screws were coated with FibMat and BP (alendronate and 14C-alendronate) using standard coupling techniques. The total amount and distribution of BP after insertion was measured by liquid scintillation and autoradiography. Coagulation assays were performed in order to determine the coagulation properties of fibrinogen, exposed to doses up to 35 kGy, mixed with thrombin. The structural properties of four different BPs (alendronate, pamidronate, zoledronate and ibandronate), exposed to doses up to 35 kGy were analysed by transmission infrared spectroscopy. The results show that FibMat/BP coating on porous stainless-steel screws is virtually unaffected by insertion into bone materials. The anodised, planar titanium screws are more affected by the insertion process, but an even BP distribution in the cancellous material is indicated. The coagulation assays show that gamma-irradiated fibrinogen has a slower coagulation process compared to non-irradiated fibrinogen and form interrupted network unable to clot. The chemical structures of the BPs seem unaffected by exposure to gamma irradiation. In conclusion, the FibMat/BP is a promising technology for local distribution of BP in conjunction with bone implants.
|
3 |
Local Delivery of Bisphosphonates from FibMat MatrixAronsson, Henrik January 2008 (has links)
<p>Improving the functionality and reducing revision rates are important driving forces in the development of orthopaedic implants. FibMat is a fibrinogen based matrix developed towards commercialisation by the company Optovent AB. This matrix can be coated on implants and act as a local drug delivery system for bisphosphonates (BPs). BPs are drugs inhibiting bone resorption, and applied with FibMat to improve stability of implants in bone, e.g. when fixing bone fractures. In this thesis, FibMat loaded with BP (FibMat/BP) was coated on stainless-steel screws and titanium screws in order to investigate some technology properties relevant to its clinical applicability. Bone-mimicking materials were used to study scrape-off effect upon insertion. The coagulation properties of fibrinogen as well as the structural properties of BPs were studied after exposure to gamma radiation.</p><p>The screws were coated with FibMat and BP (alendronate and 14C-alendronate) using standard coupling techniques. The total amount and distribution of BP after insertion was measured by liquid scintillation and autoradiography. Coagulation assays were performed in order to determine the coagulation properties of fibrinogen, exposed to doses up to 35 kGy, mixed with thrombin. The structural properties of four different BPs (alendronate, pamidronate, zoledronate and ibandronate), exposed to doses up to 35 kGy were analysed by transmission infrared spectroscopy.</p><p>The results show that FibMat/BP coating on porous stainless-steel screws is virtually unaffected by insertion into bone materials. The anodised, planar titanium screws are more affected by the insertion process, but an even BP distribution in the cancellous material is indicated. The coagulation assays show that gamma-irradiated fibrinogen has a slower coagulation process compared to non-irradiated fibrinogen and form interrupted network unable to clot. The chemical structures of the BPs seem unaffected by exposure to gamma irradiation. In conclusion, the FibMat/BP is a promising technology for local distribution of BP in conjunction with bone implants.</p>
|
4 |
Studies on Intrinsic Coagulation Pathway of ZebrafishIyer, Neha 08 1900 (has links)
In the past couple of decades, the zebrafish has been widely used to study hemostatic disorders. In this study, we generated a CRISPR/Cas9 mediated zebrafish mutant that contains a 55-nucleotide insertion in exon 29 of the von Willebrand factor (vwf) gene. The mutants had impaired ristocetin-mediated agglutination of whole blood, prolonged PTT and more bleeding in the lateral incision compared to wild-type fish. The bleeding phenotype observed here is similar to the phenotype observed in vwf knockout mice and patients with von Willebrand disease (VWD). The mutant model developed here can thus be used for exploring the role of Vwf in angiogenesis and for developing gene therapy. The deficiency of VWF causes VWD and the etiology remains unknown in 30% of Type 1 VWD cases. Previous studies have identified that the ABO blood group and ST3GAL4 (glycosyltransferases) are involved in the regulation of VWF levels. Since VWF is heavily glycosylated, we hypothesized that other glycosyltransferases may also be involved in regulating VWF. We performed a knockdown screen of 234 glycosyltransferase genes and identified 14 genes that altered Vwf levels. The sequencing of these genes in Type 1 VWD patients could help identify novel mutations to decipher the molecular basis for the unknown etiologies in Type 1 VWD. Moreover, therapeutic interventions could be designed in the future by modulation of these gene products to control bleeding or thrombosis.Zebrafish has three f9 genes, f9a, f9b, and f9l and the ortholog to human F9 is unknown. RNA analysis showed an age-dependent increase in expression of all three genes from larval stages to adults, comparable to those observed in mice and humans while mass spectrometry and immunohistochemistry confirmed the presence of all three proteins in the fish. Based on coagulation assays performed after individual gene knockdown and immunodepletion, we identified that zebrafish f9a has functional activity similar to human F9 and Fixl is functionally similar to Fx. Thus, the zebrafish could be used to identify factors controlling f9 gene expression with age and for modeling Hemophilia B in the quest to develop gene therapy protocols.
In zebrafish, dilute plasma with exogenously added human fibrinogen was used for kinetic coagulation assays. Here, we developed a microkinetic assay using 25% zebrafish or 30% human plasma followed by the addition of coagulation activators and CaCl2. Our results showed both zebrafish and human plasmas yielded kinetic PT, kinetic PTT, and kinetic Russel's viper venom time curves similar to previously established human kinetic curves. Moreover, clotting times derived from these kinetic curves were identical to human PT, PTT, and Russel's viper venom time. Thus, the microkinetic assay developed here could measure blood coagulation activity in small animal models like zebrafish and human blood samples obtained from a finger prick in adults or heel prick in infants.
|
Page generated in 0.1144 seconds