• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 3
  • 1
  • Tagged with
  • 36
  • 36
  • 35
  • 28
  • 26
  • 22
  • 20
  • 19
  • 19
  • 19
  • 17
  • 16
  • 13
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Investigation into a beam-column connection in precast concrete

Zang, Jin 03 1900 (has links)
Thesis (MScEng (Civil Engineering))--University of Stellenbosch, 2010. / ENGLISH ABSTRACT: Pre-cast sections have the advantages of structural efficiency, better quality control and less construction time, which enable them to be widely used in building structures. The connections of pre-cast buildings play a vital role for the stability and strength of structures. Nowadays, more attention is drawn to the aesthetical appearance of building structures, especially by architects. The Hidden Corbel Connection (HCC) was then developed to make the building structures stable and aesthetically pleasing. A modified HCC was designed and investigated in this study. Amongst all the mechanisms in the connection zone, the mechanism of the end anchorage length of tension reinforcement plays a key role in the economy of the connection and is hence further investigated. In order to investigate whether the end anchorage length of tension reinforcement can be reduced for a simply supported beam, a 2D non-linear finite element model is used to analyze the stress distribution inside the connection zone. Based on the stress distribution in the connection zone, the tensile force was calculated at the face of the support, which directly correlates to the required end anchorage length of tension reinforcement. The confinement in the connection zone increases the bond stress, which in turn reduces the required anchorage length of tension reinforcement. Therefore, a 3D model is used to analyze the region inside the modified HCC to find the position of the best confinement. By comparing the finite element (FE) results with Eurocode 2 (2004), and SABS 0100-1 (2000), it is demonstrated that the FE results require the shortest anchorage length, while the longest anchorage length is specified in SABS 0100-1 (2000). Based on the comparison between the FE results and the design codes, a laboratory experiment was then performed to determine if the end anchorage length of tension reinforcement can be reduced. Four beams with different support conditions and with different end anchorage length of tension reinforcement were tested. The results of the laboratory experiment indicate that the end anchorage length for simply supported beams can be shortened from the specification of SABS 0100-1 (2000).
12

Comportamento de chumbadores embutidos em concreto com fibras de aço para ligações viga-pilar de concreto pré-moldado / Behavior of dowel embedded in steel fibers concrete for beam-column connections in precast concrete

Bellucio, Ellen Kellen 23 March 2016 (has links)
O presente trabalho trata do estudo do comportamento de chumbadores grauteados inseridos em concreto com fibras de aço em ligações viga-pilar de estruturas de concreto pré-moldado. Este estudo é importante para se entender e poder quantificar a influência da rigidez deste componente no comportamento de ligações semirrígidas de estruturas de concreto pré-moldado. O objetivo do trabalho é estudar o mecanismo do chumbador no concreto com fibras de aço em ensaios específicos e avaliar também o comportamento de uma ligação viga-pilar de concreto pré-moldado utilizando estas fibras no consolo e no dente da viga. Nesta pesquisa foi realizado um programa experimental no Laboratório de Estruturas da EESC, uma análise numérica com o emprego do software DIANA® e uma comparação com formulações analíticas existentes para o cálculo da força última destes componentes. Foram ensaiados nove modelos experimentais para avaliar especificamente o mecanismo resistente do chumbador, variando-se os diâmetros das barras, sua inclinação e a porcentagem de fibras de aço no concreto. Além destes modelos, foi realizado ensaio de uma ligação viga-pilar de concreto pré-moldado para avaliar a rigidez da ligação com chumbador inserido em concreto com fibras de aço. Nos ensaios experimentais dos chumbadores observou-se que modelos com concreto com fibras de aço apresentam rigidez até 25% maior se comparado ao modelo com concreto convencional. Verificou-se que o graute utilizado para solidarizar os chumbadores exerce significativa influência na capacidade última do modelo, podendo diminuir em cerca de 30% a capacidade de carga. A ligação viga-pilar de concreto pré-moldado utilizando concreto com fibras de aço no consolo e no dente da viga se comportou de maneira satisfatória, não apresentando fissuração na interface dos diferentes concretos. Na comparação dos modelos ensaiados com as formulações teóricas extraídas de trabalhos de referência verificou-se que, para os modelos específicos de chumbador, a formulação existente é representativa. Para a ligação viga-pilar, alguns ajustes na formulação analítica se fizeram necessários para considerações de efeitos de grupo e de borda observados e decorrentes da utilização de dois chumbadores na ligação proposta neste trabalho. / This research deals with the study of the behavior of grouted dowels embedded in concrete with steel fibers. This study is important to understand and quantify the stiffness transmitted by this component in a semi-rigid connection of precast concrete structures. The objective is to study the mechanism of the dowel in the concrete with steel fibers and evaluate the mechanical behavior of a precast beam-column connection using this type of concrete on the corbels and in the dapped-end beam. In this research, an experimental program in the EESC Structures Laboratory was carried out, as well as a numerical analysis with the use of DIANA® software and a comparison with existing formulations to calculate these components. Nine models were experimentally tested to specifically evaluate the dowel resistant mechanism by varying the diameters of the bars, the declination and the percentage of steel fibers in concrete. Furthermore, an experimental test was performed in order to evaluate the behavior of the connector. The results indicate that for the dowels with concrete and steel fibers, the ultimate capacity of the connection occurs by failure of the connector (excessive deformation of the bars), while in conventional concrete this capability is associated with the rupture of the concrete and that the concrete with steel fibers decreases by 25% the deformability of the models. The grout has a significant impact on the ultimate capacity of the model, which may increase in less than 30%. In the analysis of the beam-column connection, it is possible to observe that the proposed connection exceeds by more than 20% the ultimate capacity compared to traditional beam-column connections. In comparing the theoretical models tested with the formulations shown by previous studies, it was found that for specific models dowels, the existing formulation is representative. For the beam-column connection, adjustment was performed in the previous formulation considerations group and edge effects that occur due to the use of two dowels on the tested connection.
13

Ligação viga-pilar em elementos pré-moldados de concreto solidarizados por concreto reforçado com fibras de aço: análises estática e dinâmica / Beam-column connection in precast concrete structures using steel fiber reinforced concrete

Oliveira Júnior, Luiz Álvaro de 13 June 2012 (has links)
No presente trabalho, utiliza-se concreto com fibras de aço, traspasse de armaduras e chaves de cisalhamento para desenvolver uma ligação viga-pilar capaz de resistir a ações cíclicas e dinâmicas e que possa ser empregada na pré-moldagem de estruturas de casas de força de usinas hidrelétricas. Para atingir este objetivo, inicialmente foram realizados ensaios de caracterização dos materiais, cujos resultados mostraram aumentos de 34% na resistência à tração na flexão, 16% na resistência à compressão e 33% na tenacidade, comprovando os efeitos benéficos das fibras de aço nas propriedades mecânicas do concreto. Em seguida, foram realizados ensaios de tração em tirantes, cujos resultados sugeriram que um comprimento de 15Ø é suficiente para que a emenda desenvolva as tensões de aderência de modo adequado; e ensaios de cisalhamento, cujos resultados mostraram que a ligação viga-pilar resiste a tensões de cisalhamento direto de até 0,77 MPa. Na sequencia, foram realizados ensaios cíclicos em dois modelos cruciformes para caracterização da ligação (um monolítico e outro de concreto pré-moldado, o qual empregava concreto com 1% de fibras na região da ligação), sendo o carregamento aplicado em cinco níveis de força, cada um com dez ciclos de carregamento e descarregamento. Os resultados desses ensaios mostraram que a ligação do modelo em concreto pré-moldado apresentou 85% da resistência do modelo monolítico e ruptura governada por flexão. Por fim, os ensaios dinâmicos foram realizados nos modelos cruciformes em três diferentes situações (íntegros, fraturados e após ruptura da ligação) para estimar o coeficiente de amortecimento, o qual sofreu uma redução de 31% após o ensaio cíclico. Simulações computacionais foram realizadas para complementar a investigação realizada neste trabalho. Elas mostraram representação aceitável da rigidez, mas não da resistência do modelo. / In the present work, steel fiber reinforced concrete, splicing bars and shear keys are used in order to develop a beam-column connection able to support cyclic and dynamic loadings and which can be used in precasting power houses structures of power plants. To achieve this goal, tests were carried out to characterize the materials, which showed increases of 34% in flexural tensile strength, 16% in compressive strength and 33% in toughness factor, confirming the beneficial effects of steel fibers in mechanical properties of the concrete. Then, tensile tests were carried out on rods, whose results suggested that a length of 15Ø can assure appropriate development of bond stresses through the splice; and shear tests, whose results showed that the beam-column connection resists to shear stresses of up to 0,77 MPa on shear key. After, cyclic tests were performed in two cruciform models in order to characterize the beam-column connection (one monolithic and the other precast concrete, which employed 1% steel fiber reinforced concrete in connection region, being the loading applied in five loading levels, each one in 10 cycles of loading and unloading. Results of these tests showed that precast beam-column connection presented 85% of the strength presented by the monolithic model and bending failure. Finally, dynamic tests were performed in cruciform models in three different situations (uncracked, cracked and after failure) for estimating the damping ratio, which was reduced by 31% after cycles. Computer simulations were performed to complement the research developed in this work. They showed acceptable representation of stiffness, but the strength of the model.
14

Estudo teórico-experimental de ligação viga-pilar com almofada de argamassa e chumbador para estruturas de concreto pré-moldado / Theoretical and experimental study of beam-to-column connection with pad of mortar and bolts for precast concrete structures

Sawasaki, Fábio Yoshio 05 May 2010 (has links)
As ligações com chumbador e almofada, sem continuidade estrutural, são comumente empregadas em obras de concreto pré-moldado como galpões, edifícios de poucos pavimentos e no topo de pilares. Na análise estrutural, este tipo de ligação é caracterizado como articulado. Este trabalho teve como objetivo fazer um estudo com este tipo de ligação levando em conta que a transferência de momento fletor ocorrerá em função da rigidez proporcionada por uma almofada de compósito de argamassa e por chumbadores de aço. A idéia é considerar o benefício da redução das solicitações nos elementos de concreto pré-moldado, particularmente, na base dos pilares. A análise experimental foi feita com modelos em escala reduzida 1:2. Foram ensaiados quatro modelos da ligação que são: a) Modelo 1 - chumbadores de aço CA-25 e almofada de compósito de argamassa; b) Modelo 2 - chumbadores de aço CA-25 e almofada de policloropreno; c) Modelo 3 - chumbadores de aço CA-50 e almofada de compósito de argamassa e; d) Modelo 4 - chumbadores de aço CA-50 e pilar com largura igual a 50% maior que os casos anteriores e almofada de argamassa. Foi feita ainda a análise numérica tridimensional dos modelos da ligação utilizando o software Ansys e análises de pórtico plano para avaliar a distribuição de solicitações ao longo de estruturas representativas. Foi desenvolvido um modelo de projeto para prever o comportamento da ligação. Com as simulações de pórtico plano, onde foram consideradas as semirigidezes das ligações, obteve-se uma redução de até 48% do momento fletor na base dos pilares para um edifício de quatro pavimentos, cujas ligações viga-pilares apresentavam um consolo de 40 cm, e de 21,8% para um edifício de um pavimento do tipo galpão, cujas ligações continham quatro chumbadores, considerando apenas a carga de frenagem. A análise de deslocamentos nos pórticos planos também aponta o benefício da consideração da semirigidez nas ligações. Uma redução de deslocamento horizontal do topo do pórtico do tipo galpão de até 32,8% para o modelo com ligações com quatro chumbadores e somente força horizontal, e de até 71,9% para o edifício de quatro pavimentos considerando as ligações semirígidas com consolos de 40 cm. / Connections with bolts and pad, without structural continuity, are commonly used in construction of precast concrete as one-storey building, building with a few storeys and on top of columns. In structural analysis, this type of connection is characterized as pinned, that is, without restriction of the rotation on the connection. This work aims to make a study of this type of connection taking into account that the transfer of bending moment will occur due to the stiffness provided by a pad of mortar composite and the steel bolts. The idea is to consider the benefit of reducing the demands on the elements of precast concrete, particularly at the base of the columns. The experimental analysis was done with models scale 1:2. Four models of connection were tested: a) Model 1 - steel bolts CA-25 and pad of mortar composite, b) Model 2 - steel bolts CA-25 and chloroprene rubber pad, c) Model 3 - bolts of CA-50 steel and pad of mortar composite, and d) Model 4 - steel bolts CA-50 and column with a width of 50% larger that the others and mortar pad. It was still a three-dimensional numerical analysis of the lead models using Ansys software and frame plan analysis to evaluate the stress distribution along the representative structures. A model design to predict the behavior of the connection was developed. Based on the numerical simulations on precast concrete frames, semi-rigidity of connections was take in to account, it was obtained a reduction of up to 48% of the bending moment at the base of the columns of a four-storey building, which beam-to-column connections had a corbel 40 cm, and 21,8% for a one-storey building, which connections contained four bolts, considering only the horizontal load. The analysis of displacements in the plane frame also shows the benefit of considering the semi-rigidity connections. Reduction in horizontal displacement of the top of the one-storey building to 32,8% for the model with four bolts in the connections with only horizontal force, and 71,9% for the four-storey buildings with semi-rigid connections considering the corbels of 40 cm.
15

Ligações de montagem viga-pilar para estruturas de concreto pré-moldado: estudo de caso / Assembly connections beam-column for structures of precast concrete: case study

Prado, Lisiane Pereira 19 September 2014 (has links)
A pesquisa em questão é direcionada ao estudo de uma ligação provisória entre o pilar e a viga pré-moldada para que possa servir de suporte durante a execução da ligação de estrutura, que consiste na utilização de barras de aço salientes do pilar e da viga, traspassando entre si, finalizada por concreto com adição de fibras. O uso de consolo metálico formado por perfil tipo \"U\" e dente metálico constituído de um perfil de seção retangular vazado foi o método proposto para a ligação provisória, na qual a montagem da viga no pilar se dá pelo encaixe dos elementos. O modelo adotado como dente metálico é denominado \"Cazaly Hanger\". Para avaliar o comportamento da ligação estudada foram analisados os modelos analíticos referentes aos elementos da ligação e, posteriormente, foi montado um pórtico estrutural com a ligação provisória em estudo, para analisar o seu comportamento sob um carregamento estático e monotônico. Inicialmente foi aplicada uma força referente a 71,75% da capacidade da ligação, no meio do vão da viga e excêntrico ao seu eixo para analisar a torção na ligação, simulando uma possível força acidental que venha a ocorrer durante a montagem dos elementos. Na segunda etapa foi aplicada uma força a 1/2,94 do vão da viga a fim de determinar a capacidade do dente metálico e, na terceira e última etapa, o carregamento foi aplicado a 1/7,14 do vão da viga, na extremidade oposta a força aplicada na etapa 2, para determinar a capacidade de suporte do consolo metálico. Os resultados dos ensaios mostraram que a capacidade resistida pelo dente metálico foi 33% maior que o determinado no modelo analítico e, o estado limite último do consolo metálico constituído por perfil \"U\" foi caracterizado pela deformação excessiva da alma, na região superior do consolo. Pode-se concluir que o modelo de cálculo usado no trabalho foi coerente com os resultados encontrados para o dente metálico, mas, para os consolos metálicos, os valores teóricos não foram compatíveis com os resultados encontrados no modelo prático. / The research is directed to the study of a beam-column temporary connections to provide support during the execution of structure connection, which consist on using steel bars protruding from the column and beam finalized by addition of concrete with fibers. The use of steel \"U\" shaped corbel in the column and a steel hangers rectangular hollow core section in the beam was proposed for temporary connection method, in which the erecting the beam in the columns occurs by the nest of the elements. To evaluate the behavior of the studied connections it was analyzed the analytical models of connections and, after were building a structural portico with the connection to analyze their behavior under static and monotonic loading. Initially it was applied a load corresponding to 71,75% of the connection capacity, mid-span of the beam and its eccentric to check the torsion moment on the connection, simulating a possible live load that may occur during assembly of the elements. In the second stage was applied a load of 1/2,94 span beam to determine the capacity of steel hanger rectangular hollow core section and the third and last step the load was applied at 1/7,14 span of the beam, the end opposite the load applied in step 2, to determine the ability of the steel \"U\" shaped corbel. The results showed that the steel hanger inserted capacity was 33% higher than determined in the analytical model and the ultimate limit state of the steel \"U\" shaped corbel was characterized by excessive deformation of vertical plate, in the upper region of corbel. Can conclude that the calculation model used in the study was consistent with the results found for the steel hangers rectangular hollow core section, but for the steel \"U\" shaped corbel, the theoretical values were not consistent with the results found in practical model.
16

Estudo teórico-experimental do efeito da laje na transferência de forças em ligações viga-pilar misto preenchido / Experimental and theorical analysis of slab effect on the force transfer strength of steel beam to concrete filled columns connection

Farias, Rômulo da Silva 07 May 2008 (has links)
Este trabalho tem como objetivo analisar a influência da laje de concreto armado em uma ligação viga-pilar misto mediante um estudo experimental e uma modelagem numérica. A ligação considerada é constituída por uma viga de aço unida a um pilar misto preenchido através de barras rosqueadas que trabalham como parafusos passantes. Esse tipo de ligação já foi investigado em trabalhos anteriores, mediante análise experimental em modelos que não incluíam a laje, resultando em uma indesejável ruptura dos parafusos. A análise da ligação completa, com a presença da laje de concreto tornando a ligação uma ligação mista, além de ser mais realista, melhora as características de resistência e rigidez do modelo, além de tornar mais dúctil o seu comportamento. Para isso foram analisados três modelos experimentais que se diferenciam pela ausência ou tipo de conector de cisalhamento presente na região interna do pilar misto. Os resultados obtidos mostraram que a ruptura da ligação passou a ser determinada pela laje, associada ao escoamento da armadura longitudinal sem que a ligação viga-pilar fosse comprometida. Para a análise numérica foi utilizado o pacote computacional DIANA®, baseado no método dos elementos finitos. Os modelos numéricos foram desenvolvidos e calibrados pelos resultados experimentais, produzindo resultados bastante satisfatórios. Finalmente foi realizada uma análise numérica paramétrica variando a armadura longitudinal da laje e a resistência do concreto com o objetivo de se entender melhor a influência desses parâmetros no comportamento da ligação investigada. / The main objective of this work was to analyze the contribution of the concrete slab for the behavior of a steel beam-concrete filled composite column connection through an experimental program and also a numerical modeling. The considered connection was constituted of steel beams connected to a concrete filled tubular column of rectangular cross section by means of passing bars. This type of connection was studied before through an experimental analysis of connections that did not include the slab, resulting in failure of the passing bars. In the present study, the presence of the slab is considered, turning the connection a composite one. The studied model is more representative of the real structure, and also improves the resistance and the stiffness of the connection, turning the behavior more ductile. Three specimens were tested, where the studied variable was the type of shear connector, angles or stud-bolts, and one specimen without connectors as a reference. The obtained results showed that the failure was determined by the slab, associated to the yielding of the longitudinal reinforcement, without affecting the beam column connection. The finite element based software DIANA® was used to the numerical analysis. The numerical models were developed and calibrated by the experimental results, producing a good agreement. Finally, a parametric analysis was done, varying the slab longitudinal reinforcement and the concrete strength in order to better understand the influence of these parameters in the behavior of the studied connection.
17

Comportamento de chumbadores grauteados de ligações viga-pilar parcialmente resistentes a momento fletor / Behavior of grouted dowel of partial moment resistant beam-to-column connections

Aguiar, Eduardo Aurélio Barros 05 May 2010 (has links)
Neste trabalho estudou-se o comportamento dos chumbadores grauteados, usados em ligações viga-pilar parcialmente resistentes a momento fletor. O foco da pesquisa foi a análise teórica e experimental do mecanismo resistente do chumbador inclinado. O programa experimental englobou 15 modelos, sendo que as variáveis analisados foram: a) diâmetros dos chumbadores, de 16 mm, 20 mm e 25 mm; b) inclinações dos chumbadores, de 0º (chumbador normal à interface), 45º e 60º; c) resistência à compressão do concreto adjacente ao chumbador, sendo usado concreto das classes C35 e C50; d) aplicação de força de compressão normal à interface. Os resultados experimentais indicaram aumentos significativos tanto na capacidade última quanto na rigidez a cisalhamento do chumbador. Foram realizadas simulações numéricas, onde foi verificada a sensibilidade dos resultados aos parâmetros inerentes à interface concreto - almofada de apoio, sendo desenvolvidas expressões para estimar tais parâmetros. Com base na análise experimental e em análises numéricas, foram propostos modelos analíticos que conseguiram representar de forma satisfatória a influência da inclinação e demais parâmetros analisados no mecanismo resistente do chumbador. / This research deals with the behavior of grouted dowels, used in partial moment resistant beam-to-column connections. The focus of the research was the theoretical and experimental analysis of dowels resistant mechanism. The experimental program include 15 models, and its variables analyzed were: a) the dowel diameter of 16 mm, 20 mm and 25 mm; b) the dowel inclination of 0° (dowels perpendicular to the interface), 45° and 60°; c) compressive strength of concrete adjacent to the dowels of classes C35 and C50, d) application of compression load, normal to the interface. Experimental results indicated significant increases in ultimate capacity and the shear stiffness of the dowels. Numerical simulations were carried out which identified the sensitivity of results to the parameters of the interface concrete bearing pad, and developed expressions to estimate such parameters are given. Based on experimental and numerical analysis analytical models have been proposed that could adequately represent the influence of inclination and other parameters in the mechanism resistant dowels.
18

Ligações mistas viga-pilar - análise teórica e experimental / Composite beam-column connection – Theoretical and experimental analysis

Luciana Maria Bonvino Figueiredo 19 August 2004 (has links)
Uma ligação em estruturas de aço é denominada mista quando considera-se a contribuição da laje no seu comportamento. Assim, além do detalhe da ligação em aço, outros parâmetros interferem no comportamento da ligação mista, como a taxa de armadura e o nível de interação entre a laje e a viga de aço. Os métodos de cálculo de ligações mistas derivam do Método dos Componentes proposto pelo Eurocode 3 para cálculo de ligações em aço. Apresenta-se uma adaptação de um destes métodos para cálculo de ligações mistas que representam a realidade brasileira em termos de perfis e detalhes de ligação. Foi elaborado um programa experimental de caráter exploratório envolvendo ligações mistas com chapa de topo estendida. Foram ensaiados modelos simulando pilares internos e pilares de canto. Um modelo numérico foi desenvolvido utilizando o programa Ansys, que permite a análise destas ligações de maneira simples e satisfatória. Os resultados experimentais foram confrontados com os resultados da análise numérica e com os valores obtidos a partir do modelo analítico. / A composite joint is a joint between a composite beam and a steel or composite column in which reinforced concrete slab is take into account. The moment-rotation relationship of composite joints depends on a significant number of parameters besides the type and configuration of the steel connection, as for example: the amount of steel reinforcement of the slab and the degree of interaction between the slab and the steel beam section. Based on the Eurocode 3 method for bare steel connection (Components Method), some methods have been developed for prediction the moment capacities of composite connections. I this work, an adaptation of one of these methods has been developed in which steel sections and connections details common in Brazil are considered. A short experimental program was planed in order to understand the composite behaviour of extended end-plate composite beam-column connection. The test specimens were configured as cruciform type and cantilever type. Finally, a Finite Element model was built in Ansys software. The numerical modeling was found to have good approach with experimental results. Some analyses are done involving experimental, numerical and analytical results.
19

Reforço e incremento da rigidez à flexão de ligações viga-pilar de estruturas de concreto pré-moldado com polímero reforçado com fibra de carbono (PRFC) / Flexural strengthening and stiffness increasing of precast beam-to-column connections by NSM CFRP strips

Fonseca, Tatiana de Cássia Coutinho Silva da 18 December 2007 (has links)
Este trabalho apresenta o desenvolvimento de uma técnica de incremento da resistência e da rigidez à flexão de ligações de elementos de concreto pré-moldado, com aplicação de laminados de polímero reforçado com fibra de carbono (PRFC). O procedimento adotado consiste na colagem dos laminados de PRFC em entalhes no concreto de cobrimento, de acordo com a técnica conhecida como \"near-surface mounted\" (NSM), de modo a incorporar à ligação novos elementos resistentes à tração. Para solidarizar a ligação e possibilitar a transferência de esforços de compressão entre os elementos de concreto existentes, preenchem-se os espaços vazios (grauteamento) com argamassa fluida à base de cimento Portland. Foram desenvolvidos modelos em escala reduzida, com o intuito de representar os mecanismos resistentes de uma ligação viga-pilar composta por encaixe de dente Gerber e consolo, com uso de chumbador, almofada de apoio e graute. Esse tipo de ligação é muito utilizado na construção de galpões e tem, na sua concepção original, comportamento essencialmente de articulação. Em uma etapa preliminar, realizaram-se ensaios para a caracterização da aderência segundo a configuração de reforço proposta. Os resultados dessa análise subsidiaram a fixação do comprimento de laminado a ancorar e a escolha do tipo de resina a empregar para colagem do reforço. Os modelos representativos da técnica de reforço proposta foram preparados, cada um deles, pela montagem de um elemento de pilar-consolo com elementos de viga nos respectivos chumbadores e almofadas. Foram também preparados modelos de referência para o estudo da influência da almofada de apoio e do grauteamento no comportamento resistente e da deformabilidade da ligação. Nesses modelos, as juntas eram perfeitamente conjugadas, isto é, os trechos de viga foram concretados com um elemento pré-moldado de pilar-consolo posicionado dentro da fôrma, sem disposição de almofadas. Todos os modelos de ligação foram reforçados e submetidos a ensaios estáticos. Esses ensaios consistiram na aplicação de carregamento cíclico alternado de curta duração, solicitando-se os modelos a momento fletor positivo ou negativo. Este trabalho também apresenta procedimento executivo de ensaios dinâmicos para avaliação da rigidez dos modelos de ligação em três condições: modelo íntegro reforçado, modelo reforçado fissurado (após aplicação de carregamento de aproximadamente 30% do carregamento de ruptura da ligação, em ensaio estático) e modelo reforçado rompido. Com o reforço, a ligação apresentou comportamento semi-rígido e adquiriu resistência à flexão compatível à de estrutura monolítica armada com barras de PRF. / This work presents the development of a technique for flexural strengthening and stiffness increasing of precast beam-to-column connections by the embedding of FRP strips into grooves made on the concrete cover. According to this technique, the tension in the connection is transferred by the Near-Surface Mounted (NSM) FRP strips. To allow the transference of compression efforts among the concrete elements, the empty spaces are filled out with grout. Small-scale specimens were developed to represent the resistant mechanisms of pined beam-to-column connection composed by elastomeric cushion and dowels. Preliminary experimental tests on bond behavior of NSM strips were carried out. The results analysis conducted the decision about the adhesive type and bond length to be employed in the beam-to-column connection specimens. Each specimen was made of the assembly of a column section connected to beam sections through their respective dowels and cushions. The connection specimens were reinforced by embedding CFRP strips in the lateral concrete cover and filling out the spaces between beams and column. In addition, control specimens were prepared to study the influence of the cushion and grout in the connection performance. In those models, the joints were conjugated perfectly, which means that the beam sections were laid inside the wooden forms and cast together with a precast column section with no cushions between them. Experimental static and dynamic tests were done. The tests results show that strengthened connection exhibits semi-rigid behavior and acquires flexural strength compatible to monolithic structure reinforced with FRP bars.
20

Estudo experimental de uma ligação viga-pilar em concreto pré-moldado utilizando perfis metálicos e solda / Experimental study of a precast concrete beam-column connection using welded steel shapes

Trotta, André Marcon 03 September 2012 (has links)
Nesta pesquisa estudou-se o comportamento de uma ligação viga-pilar em concreto pré-moldado utilizando perfis metálicos embutidos nos elementos estruturais. O modelo da ligação estudada permite a transmissão de momentos fletores positivo e negativo. Para a continuidade de momento fletor negativo, utilizam-se um consolo metálico com seção \"U\" embutido no pilar e dentes metálicos com seção tubular retangular embutidos nas vigas, soldados. Para a continuidade de momento positivo, utilizam-se cantoneiras metálicas embutidas no pilar que são soldadas à armadura positiva da viga. O estudo consistiu em análise experimental de um modelo cruciforme em duas etapas. Na primeira etapa o modelo foi solicitado a carregamentos cíclicos reversíveis por meio de um atuador servo hidráulico acoplado sobre o topo do pilar. Na segunda etapa, o modelo foi solicitado a carregamento estático monotônico por meio de macacos hidráulicos dispostos sob o pilar para causar a ruptura com momento negativo. O modelo apresentou uma considerável facilidade de montagem, já que na fase transitória a ligação é articulada e o consolo do pilar em perfil \"U\" permite a estabilidade lateral da viga. O consolo metálico embutido no pilar escoou muito antes de atingir a capacidade resistente dos outros componentes da ligação, pois na seção da ligação junto à face do pilar, apenas o consolo resiste à flexão. / In this research the behavior of a beam-column connection in precast concrete system using welded steel shapes built-in structural elements was studied. The model of the studied connection allows transmission of positive and negative moments. For the continuity of negative moment, is used a steel \"U\" shaped corbel inserted in the column welded with tubular section steel hangers inserted in each beam. For the continuity of positive moment, use is made of metal embedded in abutment ledges that are welded to the positive reinforcement of the beam. The study consisted on experimental analysis of a cross-shaped specimen in two steps. In the first step was applied to the specimen a cyclic load using hydraulic actuator coupled to the column head. In the second step was applied in the specimen a static load using hydraulic jack positioned under the column to cause rupture with negative moment. The connection model showed a considerably easy assembly, as in the transitional phase the connection is articulated and the steel \"U\" shaped corbel of the column allows the lateral stability of the beam. The rupture occurred by yielding of the steel U shaped corbel in the section near the column. The steel corbel inserted in the column yielded before reaches the resistant capacity of other components of the connection, because of the section in the connection close of the column, only steel corbel resists the negative moment.

Page generated in 0.1219 seconds