• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 3
  • 1
  • Tagged with
  • 36
  • 36
  • 35
  • 28
  • 26
  • 22
  • 20
  • 19
  • 19
  • 19
  • 17
  • 16
  • 13
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estudo teórico-experimental de ligação viga-pilar com almofada de argamassa e chumbador para estruturas de concreto pré-moldado / Theoretical and experimental study of beam-to-column connection with pad of mortar and bolts for precast concrete structures

Fábio Yoshio Sawasaki 05 May 2010 (has links)
As ligações com chumbador e almofada, sem continuidade estrutural, são comumente empregadas em obras de concreto pré-moldado como galpões, edifícios de poucos pavimentos e no topo de pilares. Na análise estrutural, este tipo de ligação é caracterizado como articulado. Este trabalho teve como objetivo fazer um estudo com este tipo de ligação levando em conta que a transferência de momento fletor ocorrerá em função da rigidez proporcionada por uma almofada de compósito de argamassa e por chumbadores de aço. A idéia é considerar o benefício da redução das solicitações nos elementos de concreto pré-moldado, particularmente, na base dos pilares. A análise experimental foi feita com modelos em escala reduzida 1:2. Foram ensaiados quatro modelos da ligação que são: a) Modelo 1 - chumbadores de aço CA-25 e almofada de compósito de argamassa; b) Modelo 2 - chumbadores de aço CA-25 e almofada de policloropreno; c) Modelo 3 - chumbadores de aço CA-50 e almofada de compósito de argamassa e; d) Modelo 4 - chumbadores de aço CA-50 e pilar com largura igual a 50% maior que os casos anteriores e almofada de argamassa. Foi feita ainda a análise numérica tridimensional dos modelos da ligação utilizando o software Ansys e análises de pórtico plano para avaliar a distribuição de solicitações ao longo de estruturas representativas. Foi desenvolvido um modelo de projeto para prever o comportamento da ligação. Com as simulações de pórtico plano, onde foram consideradas as semirigidezes das ligações, obteve-se uma redução de até 48% do momento fletor na base dos pilares para um edifício de quatro pavimentos, cujas ligações viga-pilares apresentavam um consolo de 40 cm, e de 21,8% para um edifício de um pavimento do tipo galpão, cujas ligações continham quatro chumbadores, considerando apenas a carga de frenagem. A análise de deslocamentos nos pórticos planos também aponta o benefício da consideração da semirigidez nas ligações. Uma redução de deslocamento horizontal do topo do pórtico do tipo galpão de até 32,8% para o modelo com ligações com quatro chumbadores e somente força horizontal, e de até 71,9% para o edifício de quatro pavimentos considerando as ligações semirígidas com consolos de 40 cm. / Connections with bolts and pad, without structural continuity, are commonly used in construction of precast concrete as one-storey building, building with a few storeys and on top of columns. In structural analysis, this type of connection is characterized as pinned, that is, without restriction of the rotation on the connection. This work aims to make a study of this type of connection taking into account that the transfer of bending moment will occur due to the stiffness provided by a pad of mortar composite and the steel bolts. The idea is to consider the benefit of reducing the demands on the elements of precast concrete, particularly at the base of the columns. The experimental analysis was done with models scale 1:2. Four models of connection were tested: a) Model 1 - steel bolts CA-25 and pad of mortar composite, b) Model 2 - steel bolts CA-25 and chloroprene rubber pad, c) Model 3 - bolts of CA-50 steel and pad of mortar composite, and d) Model 4 - steel bolts CA-50 and column with a width of 50% larger that the others and mortar pad. It was still a three-dimensional numerical analysis of the lead models using Ansys software and frame plan analysis to evaluate the stress distribution along the representative structures. A model design to predict the behavior of the connection was developed. Based on the numerical simulations on precast concrete frames, semi-rigidity of connections was take in to account, it was obtained a reduction of up to 48% of the bending moment at the base of the columns of a four-storey building, which beam-to-column connections had a corbel 40 cm, and 21,8% for a one-storey building, which connections contained four bolts, considering only the horizontal load. The analysis of displacements in the plane frame also shows the benefit of considering the semi-rigidity connections. Reduction in horizontal displacement of the top of the one-storey building to 32,8% for the model with four bolts in the connections with only horizontal force, and 71,9% for the four-storey buildings with semi-rigid connections considering the corbels of 40 cm.
32

Comportamento de chumbadores embutidos em concreto com fibras de aço para ligações viga-pilar de concreto pré-moldado / Behavior of dowel embedded in steel fibers concrete for beam-column connections in precast concrete

Ellen Kellen Bellucio 23 March 2016 (has links)
O presente trabalho trata do estudo do comportamento de chumbadores grauteados inseridos em concreto com fibras de aço em ligações viga-pilar de estruturas de concreto pré-moldado. Este estudo é importante para se entender e poder quantificar a influência da rigidez deste componente no comportamento de ligações semirrígidas de estruturas de concreto pré-moldado. O objetivo do trabalho é estudar o mecanismo do chumbador no concreto com fibras de aço em ensaios específicos e avaliar também o comportamento de uma ligação viga-pilar de concreto pré-moldado utilizando estas fibras no consolo e no dente da viga. Nesta pesquisa foi realizado um programa experimental no Laboratório de Estruturas da EESC, uma análise numérica com o emprego do software DIANA® e uma comparação com formulações analíticas existentes para o cálculo da força última destes componentes. Foram ensaiados nove modelos experimentais para avaliar especificamente o mecanismo resistente do chumbador, variando-se os diâmetros das barras, sua inclinação e a porcentagem de fibras de aço no concreto. Além destes modelos, foi realizado ensaio de uma ligação viga-pilar de concreto pré-moldado para avaliar a rigidez da ligação com chumbador inserido em concreto com fibras de aço. Nos ensaios experimentais dos chumbadores observou-se que modelos com concreto com fibras de aço apresentam rigidez até 25% maior se comparado ao modelo com concreto convencional. Verificou-se que o graute utilizado para solidarizar os chumbadores exerce significativa influência na capacidade última do modelo, podendo diminuir em cerca de 30% a capacidade de carga. A ligação viga-pilar de concreto pré-moldado utilizando concreto com fibras de aço no consolo e no dente da viga se comportou de maneira satisfatória, não apresentando fissuração na interface dos diferentes concretos. Na comparação dos modelos ensaiados com as formulações teóricas extraídas de trabalhos de referência verificou-se que, para os modelos específicos de chumbador, a formulação existente é representativa. Para a ligação viga-pilar, alguns ajustes na formulação analítica se fizeram necessários para considerações de efeitos de grupo e de borda observados e decorrentes da utilização de dois chumbadores na ligação proposta neste trabalho. / This research deals with the study of the behavior of grouted dowels embedded in concrete with steel fibers. This study is important to understand and quantify the stiffness transmitted by this component in a semi-rigid connection of precast concrete structures. The objective is to study the mechanism of the dowel in the concrete with steel fibers and evaluate the mechanical behavior of a precast beam-column connection using this type of concrete on the corbels and in the dapped-end beam. In this research, an experimental program in the EESC Structures Laboratory was carried out, as well as a numerical analysis with the use of DIANA® software and a comparison with existing formulations to calculate these components. Nine models were experimentally tested to specifically evaluate the dowel resistant mechanism by varying the diameters of the bars, the declination and the percentage of steel fibers in concrete. Furthermore, an experimental test was performed in order to evaluate the behavior of the connector. The results indicate that for the dowels with concrete and steel fibers, the ultimate capacity of the connection occurs by failure of the connector (excessive deformation of the bars), while in conventional concrete this capability is associated with the rupture of the concrete and that the concrete with steel fibers decreases by 25% the deformability of the models. The grout has a significant impact on the ultimate capacity of the model, which may increase in less than 30%. In the analysis of the beam-column connection, it is possible to observe that the proposed connection exceeds by more than 20% the ultimate capacity compared to traditional beam-column connections. In comparing the theoretical models tested with the formulations shown by previous studies, it was found that for specific models dowels, the existing formulation is representative. For the beam-column connection, adjustment was performed in the previous formulation considerations group and edge effects that occur due to the use of two dowels on the tested connection.
33

Reforço de ligações viga-pilar de estruturas de concreto pré-moldado pela colagem de laminados de polímero reforçado com fibra de carbono (PRFC) em entalhes no concreto de cobrimento / Strengthening of beam-to-column connections in precast concrete structures by NSM CFRP strips

Fonseca, Tatiana de Cássia Coutinho Silva da 07 February 2013 (has links)
Buscou-se por meio desta pesquisa avaliar a eficiência do reforço de ligações viga-pilar em estruturas de concreto pré-moldado. A técnica de reforço utilizada consiste na colagem de laminados de Polímero Reforçado com Fibra de Carbono (PRFC) em entalhes no concreto de cobrimento. Trata-se de uma técnica desenvolvida há cerca de dez anos, que apresentou, em pesquisas, desempenho superior às alternativas de colagem externa de mantas e laminados no tocante a reforço à flexão. Nenhuma referência ao uso desta ou de qualquer outra técnica para o reforço de ligações viga-pilar de estruturas pré-moldadas foi encontrada na pesquisa bibliográfica realizada. Entretanto, considera-se importante que esta opção seja apreciada ao se verificar comportamento insatisfatório de uma estrutura, haja vista a importância das ligações em seu desempenho global. Dado o caráter da pesquisa e o ineditismo da proposta, realizou-se um estudo experimental diversificado. Um ensaio piloto em modelo reduzido de pórtico com elementos de pilar e viga pré-moldados foi realizado. Por meio deste ensaio, verificou-se que o reforço promoveu significativa redução no deslocamento vertical da viga. Embora os resultados tenham sido promissores, destaca-se que o modelo reduzido impôs limitações, em relação ao comprimento para colagem do laminado e à distância do laminado ao canto da viga, que contribuíram para o seu arrancamento prematuro em uma das ligações. Realizou-se um ensaio em um modelo de ligação em escala real reforçado a momento fletor negativo e positivo. Em relação ao momento negativo, se alcançou um aumento de cerca de 100% na rigidez do modelo. Realizaram-se ensaios experimentais estáticos e dinâmicos em três modelos de pórtico cuja viga tinha escala real. Os resultados destes ensaios comprovaram a eficiência do reforço das ligações no aumento da sua rigidez , da frequência natural do pórtico e da resistência da estrutura. Observou-se também que o reforço promoveu redução da solicitação das armaduras principais da ligação. A simulação numérica dos ensaios dinâmicos permitiu a determinação indireta da rigidez das ligações de modo satisfatório e subsidiou a adoção de apoios elásticos na simulação dos ensaios estáticos que permitiram expandir a análise dos resultados experimentais em relação à fissuração e à distribuição de tensões. Por meio desta pesquisa comprovou-se a possibilidade de emprego da técnica de reforço proposta para a reabilitação de estruturas com deficiência relacionadas ao estado limite ultimo, já que o aumento de resistência foi alcançado, e também relacionadas aos estados limites de serviço, uma vez que as estruturas reforçadas apresentaram menores deslocamentos verticais e maiores frequências naturais. Destaca-se ainda uso eficiente da experimentação dinâmica que se prestou não somente à obtenção dos parâmetros modais da estrutura, mas também a uma avaliação realista das condições de contorno dos ensaios estáticos. / In this research, the strengthening of beam-to-column connections in precast concrete structures is evaluated. The strengthening technique used is internationally known as Near-Surface-Mounted and involves the bonding of CFRP (Carbon Fiber Reinforced Polymer) strips into slits made in concrete cover. There are no references about the use of this or any else technique in the strengthening of connections in precast structures however it could be an option when the structure presents an unsatisfactory behavior. Because of the innovative characteristic of the purpose, experimental tests are required. A pilot test was performed in a frame with reduced dimensions. The frame had initially pinned connections that were strengthened. The strengthening provided a reduction in the beam deflection and the recovery of the initial stiffness of the frame. Although the promising results, the frame dimensions imposed limitations in relation to the strips bonding length and to the distance to the beam edge that contributed to the premature failure by splitting of strips and concrete. It was also performed a test in a strengthened semi-rigid connection. An increase in the connection stiffness was observed. Experimental static and dynamic tests were performed on three real scaled frame models. The results of these tests demonstrated the effectiveness of the strengthening in the increasing of stiffness, natural frequency and strength of the frame. It was also observed that the strengthening reduced the reinforcement strain. The numerical simulation of the dynamic tests allowed the indirect determination of the connections stiffness and supported the definition of boundary conditions in the simulation of the static tests that allowed a better understanding in relation to cracking and stress distribution. Through this research it was confirmed that the strengthening technique proposed is useful for rehabilitation of structures with disabilities related to ultimate limit state, since the increase in resistance was achieved, and also related to the serviceability limit states, since strengthened structures presented lower vertical displacements and higher natural frequencies. It is highlighted that the dynamic tests were important not only to obtain the modal parameters of the structure, but also to evaluate the real boundary conditions of the static tests.
34

Análise da influência da rigidez das ligações viga-pilar no comportamento estrutural de edifícios de múltiplos pavimentos em concreto armado / Analysis of the influence of the stiffness of beam-column connections on the structural behavior of reinforced concrete buildings with multiple floors

Santos, Júlia Borges dos 25 April 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Conventional structural analysis of buildings in reinforced concrete is performed considering beam-column connections as rigid. However, experimental results prove the existence of relative rotations in beam-column connections of reinforced concrete structures, showing the partial transfer of bending moment. In this study the influence of the stiffness of beam-column connections on the structural behavior of multi-storey buildings in reinforced concrete was investigated. On a first stage, the value of the rotation restriction of connections was varied, observing the impact on horizontal displaceability of the structure, on the γz coefficient, on the negative and positive moments of the beams and on the longitudinal reinforcement of the pillars. This analysis was performed for buildings with 05, 10, 15 and 19 floors. The results show that the reduction of the rotation restriction of connections increases the values of the horizontal displacements, of the γz coefficient, of the positive moments and of the reinforcement of the pillars. The increases that occur on the values of the analyzed parameters become larger as the number of floors of buildings increases. On a second stage, the same building was calculated with rigid connections and deformable connections. In order to determine the factor αR of deformable connections, two analytical models available in literature were used, and a comparison between the results obtained by each analytical model was also performed. Based on the results, it is concluded that neglecting the influence of the stiffness of the beam-column connections on the analysis of monolithic reinforced concrete structures may result in different solutions compared to the real behavior of the structure. The stiffness values obtained with the analytical models that were used differ considerably from the condition of rigid connections, suggesting an adjustment on the standard consideration of rigid connections adopted by the computer programs of structural calculation. / A análise estrutural convencional de edificações em concreto armado é realizada considerando as ligações viga-pilar como rígidas. Entretanto, resultados experimentais comprovam a existência de rotações relativas nas ligações viga-pilar de estruturas de concreto armado, evidenciando a transmissão parcial de momento fletor. Neste trabalho foi investigada a influência da rigidez das ligações viga-pilar no comportamento estrutural de edificações de múltiplos pavimentos em concreto armado. Em uma primeira etapa, variou-se o valor de restrição à rotação das ligações observando os impactos na deslocabilidade horizontal da estrutura, no coeficiente γz, nos momentos negativos e positivos das vigas e nas armaduras longitudinais dos pilares. Esta análise foi realizada para edificações com 05, 10, 15 e 19 pavimentos. Observou-se por meio dos resultados que a redução da rigidez à rotação das ligações provoca aumento nos valores dos deslocamentos horizontais, do coeficiente γz, dos momentos positivos das vigas e das armaduras dos pilares. Os acréscimos ocorridos nos valores dos parâmetros analisados são maiores à medida em que se aumentam o número de pavimentos das edificações. Em uma segunda etapa, calculou-se uma mesma edificação com ligações rígidas e com ligações deformáveis. Para determinação da restrição à rotação das ligações deformáveis, utilizaram-se dois modelos analíticos disponíveis na literatura, realizando-se, também, uma comparação entre os resultados obtidos pelos modelos. Com base nos resultados, conclui-se que negligenciar a influência da rigidez das ligações viga-pilar na análise de estruturas monolíticas em concreto armado pode gerar soluções muito diferentes do comportamento real da estrutura na prática. Os valores de rigidez obtidos pelos modelos analíticos utilizados divergem consideravelmente da condição de ligações rígidas, sugerindose a adequação na consideração padrão de ligações rígidas adotada pelos programas computacionais de cálculo estrutural. / Mestre em Engenharia Civil
35

Reforço de ligações viga-pilar de estruturas de concreto pré-moldado pela colagem de laminados de polímero reforçado com fibra de carbono (PRFC) em entalhes no concreto de cobrimento / Strengthening of beam-to-column connections in precast concrete structures by NSM CFRP strips

Tatiana de Cássia Coutinho Silva da Fonseca 07 February 2013 (has links)
Buscou-se por meio desta pesquisa avaliar a eficiência do reforço de ligações viga-pilar em estruturas de concreto pré-moldado. A técnica de reforço utilizada consiste na colagem de laminados de Polímero Reforçado com Fibra de Carbono (PRFC) em entalhes no concreto de cobrimento. Trata-se de uma técnica desenvolvida há cerca de dez anos, que apresentou, em pesquisas, desempenho superior às alternativas de colagem externa de mantas e laminados no tocante a reforço à flexão. Nenhuma referência ao uso desta ou de qualquer outra técnica para o reforço de ligações viga-pilar de estruturas pré-moldadas foi encontrada na pesquisa bibliográfica realizada. Entretanto, considera-se importante que esta opção seja apreciada ao se verificar comportamento insatisfatório de uma estrutura, haja vista a importância das ligações em seu desempenho global. Dado o caráter da pesquisa e o ineditismo da proposta, realizou-se um estudo experimental diversificado. Um ensaio piloto em modelo reduzido de pórtico com elementos de pilar e viga pré-moldados foi realizado. Por meio deste ensaio, verificou-se que o reforço promoveu significativa redução no deslocamento vertical da viga. Embora os resultados tenham sido promissores, destaca-se que o modelo reduzido impôs limitações, em relação ao comprimento para colagem do laminado e à distância do laminado ao canto da viga, que contribuíram para o seu arrancamento prematuro em uma das ligações. Realizou-se um ensaio em um modelo de ligação em escala real reforçado a momento fletor negativo e positivo. Em relação ao momento negativo, se alcançou um aumento de cerca de 100% na rigidez do modelo. Realizaram-se ensaios experimentais estáticos e dinâmicos em três modelos de pórtico cuja viga tinha escala real. Os resultados destes ensaios comprovaram a eficiência do reforço das ligações no aumento da sua rigidez , da frequência natural do pórtico e da resistência da estrutura. Observou-se também que o reforço promoveu redução da solicitação das armaduras principais da ligação. A simulação numérica dos ensaios dinâmicos permitiu a determinação indireta da rigidez das ligações de modo satisfatório e subsidiou a adoção de apoios elásticos na simulação dos ensaios estáticos que permitiram expandir a análise dos resultados experimentais em relação à fissuração e à distribuição de tensões. Por meio desta pesquisa comprovou-se a possibilidade de emprego da técnica de reforço proposta para a reabilitação de estruturas com deficiência relacionadas ao estado limite ultimo, já que o aumento de resistência foi alcançado, e também relacionadas aos estados limites de serviço, uma vez que as estruturas reforçadas apresentaram menores deslocamentos verticais e maiores frequências naturais. Destaca-se ainda uso eficiente da experimentação dinâmica que se prestou não somente à obtenção dos parâmetros modais da estrutura, mas também a uma avaliação realista das condições de contorno dos ensaios estáticos. / In this research, the strengthening of beam-to-column connections in precast concrete structures is evaluated. The strengthening technique used is internationally known as Near-Surface-Mounted and involves the bonding of CFRP (Carbon Fiber Reinforced Polymer) strips into slits made in concrete cover. There are no references about the use of this or any else technique in the strengthening of connections in precast structures however it could be an option when the structure presents an unsatisfactory behavior. Because of the innovative characteristic of the purpose, experimental tests are required. A pilot test was performed in a frame with reduced dimensions. The frame had initially pinned connections that were strengthened. The strengthening provided a reduction in the beam deflection and the recovery of the initial stiffness of the frame. Although the promising results, the frame dimensions imposed limitations in relation to the strips bonding length and to the distance to the beam edge that contributed to the premature failure by splitting of strips and concrete. It was also performed a test in a strengthened semi-rigid connection. An increase in the connection stiffness was observed. Experimental static and dynamic tests were performed on three real scaled frame models. The results of these tests demonstrated the effectiveness of the strengthening in the increasing of stiffness, natural frequency and strength of the frame. It was also observed that the strengthening reduced the reinforcement strain. The numerical simulation of the dynamic tests allowed the indirect determination of the connections stiffness and supported the definition of boundary conditions in the simulation of the static tests that allowed a better understanding in relation to cracking and stress distribution. Through this research it was confirmed that the strengthening technique proposed is useful for rehabilitation of structures with disabilities related to ultimate limit state, since the increase in resistance was achieved, and also related to the serviceability limit states, since strengthened structures presented lower vertical displacements and higher natural frequencies. It is highlighted that the dynamic tests were important not only to obtain the modal parameters of the structure, but also to evaluate the real boundary conditions of the static tests.
36

Понашање моментих веза са чеоном плочом и четири завртња у реду / Ponašanje momentih veza sa čeonom pločom i četiri zavrtnja u redu / Behaviour of end-plate moment connections with four bolts per row

Jovanović Đorđe 05 June 2020 (has links)
<p>У овом раду спроведене су опсежна експериментална и нумеричка<br />испитивања понашања веза са чеоном плочом и четири завртња у реду,<br />као и карактеристичне компоненте ових веза - Т-елемента.<br />Експериментална испитивања укључују тестирања 36 узорака<br />Т-елемената у природној величини, као и четири везе греда-стуб са<br />чеоном плочом и четири завртња у реду, такође у природној величини.<br />Нумеричке анализе, спроведене у софтверском пакету ABAQUS, су<br />обухватале све типове нелинеарности, али и отказ материјала, те се као<br />такве сврставају међу ретке којима су слични проблеми нумерички<br />испитивани. Параметарска студија обухвата 33 различите конфигурације<br />Т-елемената са четири завртња и представља највећу такву студију<br />изведену за ову компоненту. Као основни још увек нерешен проблем,<br />круцијалан за понашање Т-елемената, препознати су положај сила услед<br />ефеката полуге, али и савијање завтњева. Приказан је и предложен нови<br />аналитички модел прорачуна носивости Т-елемената са четири завртња,<br />и квантификована његова предност над до сада постојећим моделима.</p> / <p>U ovom radu sprovedene su opsežna eksperimentalna i numerička<br />ispitivanja ponašanja veza sa čeonom pločom i četiri zavrtnja u redu,<br />kao i karakteristične komponente ovih veza - T-elementa.<br />Eksperimentalna ispitivanja uključuju testiranja 36 uzoraka<br />T-elemenata u prirodnoj veličini, kao i četiri veze greda-stub sa<br />čeonom pločom i četiri zavrtnja u redu, takođe u prirodnoj veličini.<br />Numeričke analize, sprovedene u softverskom paketu ABAQUS, su<br />obuhvatale sve tipove nelinearnosti, ali i otkaz materijala, te se kao<br />takve svrstavaju među retke kojima su slični problemi numerički<br />ispitivani. Parametarska studija obuhvata 33 različite konfiguracije<br />T-elemenata sa četiri zavrtnja i predstavlja najveću takvu studiju<br />izvedenu za ovu komponentu. Kao osnovni još uvek nerešen problem,<br />krucijalan za ponašanje T-elemenata, prepoznati su položaj sila usled<br />efekata poluge, ali i savijanje zavtnjeva. Prikazan je i predložen novi<br />analitički model proračuna nosivosti T-elemenata sa četiri zavrtnja,<br />i kvantifikovana njegova prednost nad do sada postojećim modelima.</p> / <p>In this research, extensive experimental and numerical investigations of<br />behaviour of end-plate moment connection with four bolts per row are<br />performed, as well as specific component of the connection &ndash; T-stub element.<br />Experimental research comprises tests on 36 unscaled specimens of T-stub<br />elements and 4 specimens of beam-to-column joints with end-plate connection<br />and four bolts per row, also in full-size. Numerical analyses, performed with<br />software ABAQUS, included all types of nonlinearities, and material<br />deterioration, hence they can be considered as one of the few most<br />sophisticated analyses used for investigation of the considered problem. The<br />parametric study comprises 33 different configurations of the T-stub element<br />with four bolts per row and it presents the biggest study of this kind for this type<br />of component. Bending of the bolts and position of the prying forces are<br />recognized as the largest, still unsolved problem, crucial for the behavior of the<br />T-stub elements. A new theoretical model for the resistance of the T-stub<br />element with four bolts per row is proposed and its advantage over the existing<br />models is presented and quantified.</p>

Page generated in 0.1207 seconds