• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 652
  • 41
  • 40
  • 40
  • 39
  • 24
  • 11
  • 11
  • 10
  • 10
  • 6
  • 5
  • 2
  • 1
  • 1
  • Tagged with
  • 674
  • 625
  • 333
  • 252
  • 178
  • 146
  • 142
  • 142
  • 115
  • 110
  • 76
  • 74
  • 73
  • 66
  • 57
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Efeito do selamento, reparo e recontorno sobre a longevidade de restaurações de resina composta em dentes posteriores segundo critério USPHS/RYGE

Fernández Godoy, Eduardo Maximiliano [UNESP] 15 July 2015 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-15. Added 1 bitstream(s) on 2016-12-09T13:54:49Z : No. of bitstreams: 1 000867872.pdf: 1681629 bytes, checksum: 8c8d0ef7b0cc0f0f1c1d43325e7ab114 (MD5) / O objetivo geral deste trabalho foi determinar o efeito de selamento marginal, recontorno e reparo sobre a longevidade de restaurações de resina composta em dentes posteriores segundo Critério USPHS/Ryge. Foi realizado estudo experimental, longitudinal, prospectivo triplo-cego, incluímos 107 restaurações de resina composta de um grupo de 26 pacientes, de ambos os gêneros. Todos os pacientes foram recrutados na clínica da faculdade de Odontologia da Universidade do Chile em 2003 de acordo com os seguintes critérios de inclusão: apresentar restaurações de resina composta em dentes posteriores com defeitos, apresentando uma ou mais características clínicas classificadas como Bravo ou Charlie acordo com critérios USPHS/Ryge.Foram constituídos os seguintes grupos experimentais: 1.- Selamento, 2.- recontorno, 3.- Reparação, 4.- substituição, 5.- Sem intervenção.Os dentes dos voluntários foram avaliados e classificados pelo critério USPHS/Ryge por dois examinadores treinados e calibrados (0.75), A longevidade das restaurações foi avaliada antes da intervenção e após 1, 2, 3, 4, 5 e 10 anos de observação. Resultados, em geral, os grupos estudados mostraram restaurações clinicamente aceitáveis após dez anos de acompanhamento. O selamento e o recontorno mostraram efeito de melhoria imediata, que se perdeu ao longo do tempo (p<0.05). O reparo foi efetivo e apresentou resultados semelhantes a substituição total da restauração após 10 anos de uso clínico (p>0.05). Conclusão: O reparo aumentou a longevidade da restauração de resina composta em dentes posteriores por 10 anos enquanto o recontorno e o selamento marginal mostraram benefícios somente até 4 anos. Estes procedimentos minimamente invasivos mostraram-se validos e poderiam ser adotados pelos programas de saúde pública e pela faculdade...(Resumo completo, clicar acesso eletrônico abaixo) / The aim of this study was to determine the effect of marginal sealing, refurbishing and repair on the longevity of composite resin restorations in posterior teeth by criteria USPHS / Ryge. This clinical trial was longitudinal, tripleblind prospective. Were included 107 composite restorations of a group of 26 patients, of both genders. All patients were recruited in the clinic of Dentistry faculty of the University of Chile in 2003 according to the following inclusion criteria: presenting composite restorations in posterior teeth with defects, showing one or more clinical features classified as Bravo or Charlie according to USPHS / Ryge. According following criteria constituted the groups: 1.-Sealing, 2.-Refurbished 3. Repair, 4. No treatment and 5. Replacement. The restorations were evaluated and classified by USPHS criteria / Ryge by two trained and calibrated examiners (kappa 0.75), longevity of restorations was evaluated before the intervention and after 1, 2, 3, 4, 5 and 10 years. Results, in general, the groups showed restorations values acceptable to the ten year follow-up in the repair group, sealed and refurbished, the improvements were immediate and the effect remained se. Conclusions: Alternative treatments repair, sealing and refurbishing were able to improve some parameters deteriorated...(Complete abstract electronic access below)
112

Avaliação in vitro da rugosidade de superfície de uma resina composta coberta com selantes com ou sem carga quando submetida à abrasão por escovação com diferentes tipos de dentifrícios

Pressi, Heloísa January 2015 (has links)
Made available in DSpace on 2015-04-30T14:06:27Z (GMT). No. of bitstreams: 1 000467672-Texto+Completo-0.pdf: 1155191 bytes, checksum: e28fce24bd1c2748fbcead34d7bf4c08 (MD5) Previous issue date: 2015 / The objectives of this in vitro study were: 1) to evaluate the surface roughness of a composite resin covered by sealing surface containing inorganic filler or not, subject to brushing; 2) to analyze, with the aid of scanning electron microscopy, the presence of the sealant after 48 months of simulated toothbrushing; 3) verify that the type of toothpaste reduces the useful life of sealants; 4) verify the presence of inorganic filler prevents the increase in roughness forward to brushing. For this, 54 samples were made of composite resin and divided into nine groups: G1 - without composite sealant (control); G2 - Sealant Fortify, toothpaste Colgate Professional Whitening; G3 - Fortify, Colgate Total Clean Mint; G4 - Fortify, Edel White Whitening; G5 - Fortify, Edel White Gum Care; G6 - Fortify Plus, Colgate Whitening Professional; G7 - Fortify Plus, Colgate Total Clean Mint; G8 - Fortify Plus White Whitening Edel; G9 - Fortify Plus, Edel White Gum Care and analyzed the simulated periods of brushing (12,24, 36 and 48 months). Reading roughness was performed at baseline and after each simulated toothbrushing period, using a surface roughness (SJ 201 Mututoyo).Two specimens of each group were observed by SEM. The data were submitted to ANOVA and Tukey's test (5%). There was a significant difference between the two sealants, with the sealant Fortify Plus rougher. Among the toothpaste, Colgate Clean Mint associated with Fortify Plus sealant obtained the higher roughness values. Lower values were associated with Gum Care Fortify sealant. The protective layer formed by the sealant remained partially by the end of 48 months of brushing, maintaining the smoothness of the composite. We conclude that both sealants guaranteed protection of the composite, and the Fortify Plus rougher for all assessed toothpastes. Clinical significance: The roughness of the surface sealant is changed for different toothpastes and different times of brushing and the addition of inorganic filler in sealants promotes different performances in relation to surface roughness. / Os objetivos deste estudo in vitro foram: 1) avaliar a rugosidade de superfície de uma resina composta coberta por selantes de superfície contendo carga inorgânica ou não, submetidas à escovação simulada; 2) analisar, com auxílio da microscopia eletrônica de varredura, a presença dos selantes após 48 meses de escovação simulada; 3) verificar se o tipo de dentifrício diminui o tempo de vida útil dos selantes; 4) verificar se a presença de carga inorgânica previne o aumento da rugosidade frente à escovação. Para isto, foram confeccionadas 54 amostras de resina composta e divididas em nove grupos: G1 – compósito sem selante (controle); G2 – Selante Fortify, dentifrício Colgate Professional Whitening; G3 – Fortify, Colgate Total Clean Mint; G4 – Fortify, Edel White Branqueador; G5 – Fortify, Edel White Gum Care; G6 – Fortify Plus, Colgate Professional Whitening; G7 – Fortify Plus, Colgate Total Clean Mint; G8 – Fortify Plus Edel White Branqueador; G9 – Fortify Plus, Edel White Gum Care e analisados nos períodos simulados de escovação de 12, 24, 36 e 48 meses. A leitura da rugosidade foi realizada no baseline e após cada período de escovação simulada, utilizando um rugosímetro de superfície (SJ 201 Mututoyo). Dois corpos de prova de cada grupo foram observados em MEV. Os dados foram submetidos à ANOVA e Teste de Tukey (5%). Verificou-se diferença significativa entre os dois selantes, sendo o selante Fortify Plus mais rugoso. Entre os dentifrícios, o Colgate Clean Mint associado ao selante Fortify Plus obteve os maiores valores de rugosidade. Os menores valores observados foram com Gum Care associado ao selante Fortify. A camada de proteção formada pelos selantes permaneceu parcialmente até o final de 48 meses de escovação, mantendo a lisura do compósito. Conclui-se que ambos os selantes garantiram proteção da resina composta, sendo o Fortify Plus mais rugoso para todos os dentifrícios avaliados. Significância clínica: A rugosidade dos selantes de superfície é alterada em função de diferentes dentifrícios e diferentes tempos de escovação e a adição de carga inorgânica nos selantes promove desempenhos diferentes em relação à rugosidade superficial.
113

Análise da citotoxicidade de compósitos restauradores para técnica direta e indireta: estudo in vitro

Mildner, Mariele Diná January 2015 (has links)
Made available in DSpace on 2015-09-05T02:05:03Z (GMT). No. of bitstreams: 1 000474592-Texto+Completo-0.pdf: 757600 bytes, checksum: b10e64c161ec1e67c4e8d9aa24a580ae (MD5) Previous issue date: 2015 / An appropriate monomer conversion of composite resins is very important to improve your biocompatibility. The aim of this study was to evaluate additional polymerization methods of dental resins cytotoxicity. A total of 72 samples were prepared from the following materials: Filtek Z350XT® (3M/ESPE, St Paul, MN, EUA), Sinfony (3M/ESPE, St Paul, MN, EUA), Lava Ultimate (3M/ESPE, St Paul, MN, EUA). The used color was A2 for all composite resins. To Filtek Z350XT and Sinfony a Teflon mould (3x2mm) was used. From Lava Ultimate block 1,6mm cubes was cutting with diamond discs and digital pachymeter. Samples was divided in 4 groups: FK Group: 20s LED polymerization, S Group: Sinfony with light and vacuum additional polymerization, L Group: Lava Ultimate, FPA Group: Filtek Z350XT with light and vacuum additional polymerization. Evaluate specimens was stored in DMEM medium for 24, 48 and 72 hours respectively. Thereafter, culture medium was in contact with NIH/3T3 fibroblasts. MTT test determined cellular viability. Statistical analysis realized by Levene and Kolmogorov-Smirnov tests (α=0,05). The S group show the lower cytotoxicity. Additional polymerization of FK group wasn´t efficient to cellular viability. Sinfony presented minor cytotoxicity among all tested materials. Light and vacuum additional polymerization of Filtek Z350XT don´t improve your cytotoxicity results when compared with direct polymerization of the same dental composite. / Um satisfatório grau de conversão do monômero é importante para melhorar a biocompatibilidade das resinas compostas. O objetivo deste estudo foi avaliar o efeito dos métodos de polimerização adicional na citotoxicidade de diferentes compósitos restauradores. Para isso foram confeccionadas 18 amostras de cada uma das seguintes resinas testadas: Filtek Z350XT® (3M/ESPE, St Paul, MN, EUA), Sinfony (3M/ESPE, St Paul, MN, EUA), Lava Ultimate (3M/ESPE, St Paul, MN, EUA). A cor usada em todas as reinas foi a A2 de corpo. Para as resinas Filtek Z350XT e Sinfony utilizaram-se moldes de politetrafluoretileno de 3x2mm. Para a resina Lava Ultimate foram cortados do bloco cubos com 1,6mm de face usando um disco diamantado e paquímetro digital. As amostras foram divididas em 4 grupos: Grupo FK: Filtek Z350XT polimerizada por 20s com LED, Grupo S: Sinfony com polimerização adicional com luz e vácuo, Grupo L: Lava Ultimate, Grupo FPA: Filtek Z350XT com polimerização adicional com luz e vácuo. As espécies avaliadas estiveram em contato com meio DMEM por um período de incubação de 24, 48 e 72 horas respectivamente. Após, o meio de cultura foi colocado em contato com as células de fibroblastos NIH/3T3. Teste de MTT foi realizado para análise da viabilidade celular. Testes de Levene e Kolmogorov-Smirnov (α=0,05) foram utilizados para análise estatística. O grupo S apresentou-se com a citotoxicidade mais baixa. Já a polimerização adicional no grupo FK não mostrou-se eficiente para a viabilidade celular. A resina Sinfony apresentou a menor citotoxicidade dentre os três materiais analisados. Uma polimerização adicional por luz e vácuo na resina Filtek Z350XT não melhora seu resultado para citotoxicidade quando comparado a polimerização direta da mesma.
114

Avaliação da adaptação e da microinfiltração marginal de uma resina composta de incremento único frente a diferentes técnicas de fotoativação

Gamarra, Vania Stephanie Sánchez January 2016 (has links)
Made available in DSpace on 2016-04-13T12:03:53Z (GMT). No. of bitstreams: 1 000477938-Texto+Parcial-0.pdf: 192614 bytes, checksum: ac0bcd8326b2183c17301f29601b81ee (MD5) Previous issue date: 2016 / The aim of this study was to evaluate, in vitro, the marginal adaptation and microleakage of class II restorations of SonicFill composite resin with different curing techniques. Class II preparations were prepared in 40 human premolars (mesial margin 1 mm below the CEJ, distal margin 1 mm above the CEJ), and randomly divided into 4 groups according to curing technique (n = 10 per group): G1: 1200 mW/cm2 for 20 s; G2: 1200 mW/cm2 for 40 s; G3: Soft-start for 20 s (650 mW/cm2 for 5 s, increasing to 1200 mW/cm2 for 15 s); G4: Soft-start for 40 s (650 mW/cm2 for 10 s, increasing to 1200 mW/cm2 for 30 s). Three-step etch&rinse adhesive Optibond FL was applied and the cavity was filled in bulk with SonicFill composite resin, followed by oclusal sculpture and photoactivation. Impressions were made using polyvinyl siloxane and epoxy resin replicas were obtained, before and after thermocycling. The occlusal and cervical margins were analyzed with SEM at 200x magnification. The marginal adaptation was expressed as percentages of continuous margins. After thermocycled, the specimens were immersed in silver nitrate 50%, and analyzed the extention of dye penetration in the cervical-mesial and cervical-distal margins. According to ANOVA and Tukey’s test, there was statistical difference in the percentage of continuous margins on the occlusal-palatine for group 1 (83. 19%), differing statistically from groups 2, 3 and 4 that had values over 95% for continuous margins (p≤0,05).In the cervical margin there was no statistical difference between the groups (p≥0,05). According to Student's t test, after thermocycling, there was a statistical significant reduction of percentage of continuous margins in occlusal-buccal margin for groups 1, 2 and 4, as well as in the cervical-mesial margin for groups 1, 3 and 4, and cervical-distal margin only to group 1. According to Kruskal-Wallis test, there was no significant difference in the microleakage scores between groups in the enamel (p=0. 373) and in dentin (p=0. 561), being predominantly score 1 in enamel and score 3 in dentin. The bulk filling technique with SonicFill composite resin associated with three-step etch&rinse adhesive Optibond FL in class II cavities provided gap formation and microleakage, especially in the cervical dentin region, regardless of the curing technique. / O objetivo do estudo foi avaliar, in vitro, a adaptação e o selamento marginal de restaurações classe II em resina composta SonicFill com diferentes técnicas de fotoativação. Foram realizados preparos classe II em 40 pré-molares humanos (caixa mesial 1 mm abaixo da JCE, caixa distal 1 mm acima JCE), sendo divididos aleatoriamente em 4 grupos de acordo com a técnica de fotoativação (n = 10 por grupo): G1: 1200 mW/cm2 por 20 s; G2: 1200 mW/cm2 por 40 s; G3: Soft-start por 20 s (650 mW/cm2 por 5 s, elevando para 1200 mW/cm2 por 15 s); G4: Soft-start por 40 s (650 mW/cm2 por 10 s, elevando para 1200 mW/cm2 por 30 s). O sistema adesivo Optibond FL foi aplicado e a cavidade foi preenchida em incremento único com a resina composta SonicFill, seguido da escultura da oclusal e fotoativação. A partir de moldagens com silicone por adição, foram obtidas réplicas em resina epóxica das restaurações antes e após termociclagem. As margens das réplicas, ao nível oclusal e cervical, foram analisadas no MEV em 200x, sendo determinada a porcentagem de margens continuas. Após termociclagem, os corpos de prova foram submetidos à metodologia de microinfiltração com nitrato de prata a 50%, sendo analisada a extensão da penetração na margem cervical mesial e distal. De acordo com ANOVA e teste de Tukey, houve diferença estatística na porcentagem de margens contínuas na oclusal-palatina para o grupo 1 (83,19%), diferindo estatisticamente dos grupos 2, 3 e 4 que tiveram valores acima de 95% para margens contínuas (p≤0,05).Na margem cervical não houve diferença estatística entre os grupos (p≥0,05). De acordo com o teste t-student, após termociclagem, houve redução estatisticamente significativa na porcentagem de margens continuas na margem oclusal-vestibular para os grupos 1, 2 e 4, assim como na margem cervical-mesial para os grupos 1, 3 e 4, e na região cervical-distal apenas para o grupo 1. De acordo com o teste de Kruskal-Wallis, não houve diferença significativa para os escores de microinfiltração entre os grupos, tanto no esmalte (p=0,373) como na dentina (p=0,561), sendo predominantemente escore 1 em esmalte e escore 3 em dentina. A técnica de incremento único com a resina composta SonicFill, associada ao sistema adesivo Optibond FL, em cavidades classe II, proporcionou a formação de fendas e a ocorrência de microinfiltração, principalmente na região cervical com término em dentina, independente da técnica de fotoativação.
115

Obtenção de compósitos de borracha natural com resíduo industrial de couro reticulados com diferentes peróxidos /

Santos, Renivaldo José dos. January 2014 (has links)
Orientador: Aldo Eloizo Job / Banca: José Antonio Malmonge / Banca: Ana Maria Pires / Banca: Eduardo Ribeiro de Azevedo / Banca: Maria Alice Martins / Resumo: Processos de curtimento de couro têm causado impacto ambiental como resultado da geração de resíduo sólido, resíduos provenientes do processo de lavagem do couro (waterwaste) bem como a liberação de gases durante os procedimentos. O descarte inapropriado deste resíduo pode promover, por exemplo, a oxidação do cromo, passando de Cr III para Cr IV, tornando-se extremamente tóxico. Além disso, o descarte apropriado do resíduo (principalmente o resíduo sólido) em aterros regularizados aumenta consideravelmente o custo de produção para a indústria de couro. Baseado nestas informações, esta tese de doutorado, reporta um método de reciclagem de resíduo industrial de couro (coletado na região de Presidente Prudente) implementado na preparação de compósitos de borracha natural, variando a quantidade de resíduo incorporado nos compósitos de 40 e 80 phr, bem como avaliado o uso de diferentes agentes de vulcanização, os quais são peróxido de dicumila (DCP), peróxido 2,5 Dimetil Hexano 2,5 Di Terc-Butil, (DHBP) e enxofre (S), todo obtidos comercialmente. Os compósitos foram preparados sob alta pressão e nas de temperaturas de 150 e 180ºC. A caracterização foi realizada utilizado reometria, cálculo de energia da ativação aparente, determinação da densidade de ligações cruzadas por inchamento e ressonância magnética nuclear, ensaio de envelhecimento acelerado, resistência a tração na ruptura, resistência a abrasão, dureza Shore A, microscopia eletrônica de varredura (MEV), espectroscopia por FT-IR no modo ATR, calorimetria exploratória diferencial (DSC), termogravimetria (TG) acoplada a espectroscopia no infravermelho (TG/FTIR), análise dinâmica mecânica (DMA) e lixiviação. O principal resultado demonstra que aumentando a quantidade de resíduo de couro aumenta-se a tensão de ruptura e resistência ao desgaste, apresentando boa reprodutibilidade bem como uniformidade na distribuição do resíduo... / Abstract: Leather tanning processes have occasioned environmental impact as a result of the generation of solid waste, wasterwater and release of gases during the procedures. The improper disposal of such waste may promote the oxidation of chromium, increasing the Cr III to Cr IV, in which becomes extremely toxic. Furthermore, the appropriate disposal of the residue (mainly solid residue) at regularized landfil increase substantialy the production cost to the leather industry. Based on this information, this Ph.D. thesis reports a new method to recycling industrial leather waste (collected around Presidente Prudente city) implemented on preparation of natural rubber composites varying the amount of residue between 20 and 80 phr as well as evaluating different curing agents (crosslink generation) using dicumyl peroxide (DCP), peroxide 2,5 Dimethyl Hexane 2.5 Di Tert. Butyl (DHBP) and sulfur (S) obtained commercially. The composites were prepared under high pressure at a range of temperature of 150 to 180ºC. Moreover, the characterization was performed using, rhemetry, calculation of the apparent activation energy, determination of crosslink density by swelling and nuclear magnetic resonance, accelerated aging tests, stress-strain tests (rupture resistance at break), abrasion resistance, hardness Shore A, scanning electron microscopy (SEM), FT-IR spectroscopy in ATR mode, differential scanning calorimetry (DSC), thermalgravimetric (TG) coupled to infrared spectroscopy (TGA/FTIR), dynamic mechanical analysis (DMA) and evaluation of the leaching compounds. The main result showed that increasing the waste leather amount increased the tensile strength and abrasion resistance, with good reproducibility and uniformity of residuals distribution as fillers (miscible materials). The production of the natural rubber/leather waste composite lead to a correct management to the leather waste into a viable industrial application, eliminating a major... / Doutor
116

Avaliação do efeito da fumaça do cigarro na translucidez da resina composta : influência do selante da superfície e da escovação /

Takeuchi, Cristina Yoshie Garcia. January 2004 (has links)
Orientador: Welingtom Dinelli / Banca: José Roberto Cury Saad / Banca: Regina Guenka Palma Dibb / Resumo: O objetivo deste estudo foi avaliar in vitro a translucidez da resina composta, em função do efeito do selamento superficial; da exposição à fumaça de cigarro e da escovação. Para tanto, 40 corpos-de-prova (10 mm X 1 mm) foram confeccionados com resina composta Filtek Z250 divididos aleatoriamente em 4 grupos (n=10), sendo: G1 - controle (saliva artificial e sem selante); G2 - saliva artificial e com selante (Protect-it!); G3 - cigarro e sem selante e G4 - cigarro e com selante. Os espécimes foram submetidos à avaliação da translucidez em diferentes tempos: T1: imediatamente após a confecção; T2: após o polimento; T3: após o selamento (G2 e G4); T4: após o 1º tratamento (10 dias imersos em saliva artificial ou manchados por 200 cigarros); T5: após serem submetidos a 1ª escovação (850 ciclos); T6: após o 2º tratamento (10 dias imersos em saliva artificial ou manchados por 200 cigarros); T7: após serem submetidos a 2ª escovação (850 ciclos); T8: após o 3º tratamento (10 dias imersos em saliva artificial ou manchados por 200 cigarros); T9: após serem submetidos a 3ª escovação (850 ciclos). Os valores de translucidez foram obtidos no aparelho JOUAN e analisados estatisticamente pelos testes de Mann-Whitney, Kruskal-Wallis, Friedman, seguidos da Análise de Variância e teste de Tukey. Observou-se que o selamento não provocou alteração significativa da translucidez dos espécimes e que após a 1ª escovação ocorreu aumento significativo, mantendo-se constante nos G1 e G2, e para os G3 e G4 o cigarro provocou severo manchamento que foi removido parcialmente pela escovação. Concluindo que o selamento não promoveu melhora na translucidez com o tempo e nem protegeu contra manchamento, sendo que a escovação não restabeleceu a translucidez. / Abstract: The aim of this study was to assess in vitro the translucency of the composite resin, in function of the effect of the surface sealing; after the exposition to the cigarette smoke and of the toothbrushing. Forty specimens (10mm X 1mm) they were made with composite resin Filtek Z250 divided into 4 groups (n = 10), being: G1 - it controls (it artificial saliva and without sealant); G2 - it artificial saliva and with sealant (Protect-it!); G3 - cigarette and without sealant and G4 - cigarette and with sealant. The specimens were submitted to the evaluation of the translucency in different times: T1: immediately after the making; T2: after the polishing; T3: after the sealing (G2 and G4); T4: after the 1st treatment (10 submerged days in artificial saliva or spotted for 200 cigarettes); T5: after they be submitted to 1st toothbrushing (850 cycles); T6: after the 2nd treatment (10 submerged days in artificial saliva or spotted for 200 cigarettes); T7: after they be submitted to 2nd toothbrushing (850 cycles); T8: after the 3rd treatment (10 submerged days in artificial saliva or spotted for 200 cigarettes); T9: after they be submitted to 3rd toothbrushing (850 cycles). The translucency values were obtained in the JOUAN apparel and analyzed by the tests of Mann-Whitney, Kruskal-Wallis and Friedman, following by the Analysis of Variance and test of Tukey. It was observed that the sealing didn't provoke significant alteration of the translucency of the specimens and that after to 1st toothbrushing it happened significant increase, staying constant in G1 and G2, and for G3 and G4 the cigarette provoked severe staining that was removed partially by the toothbrushing. Concluding that the sealing didn't promote improvement in the translucency with the time and nor it protected against staining, and the toothbrushing didn't reestablish the translucency. / Mestre
117

Propriedades mecânicas, físico-químicas e biológica de adesivo experimental com incorporação de epigalocatequina-3-galato /

Fonseca, Beatriz Maria da. January 2015 (has links)
Orientador: Sérgio Eduardo de Paiva Gonçalves / Co-orientador: Anuradha Prakki / Banca: Alexandre Luiz Souto Borges / Banca: Kátia Regina Hostílio Cervantes Dias / Banca: Roberta Caroline Bruschi Alonso / Banca: César Rogério Pucci / Resumo: O objetivo desse estudo foi avaliar o efeito da adição de EGCG em adesivo experimental na manutenção da camada híbrida, avaliando suas propriedades mecânicas, físico-químicas e biológica. A primeira etapa do estudo envolveu a manipulação do adesivo com incorporação de EGCG (0,5%, 1,0% e 1,5%) na relação BisGMA 55% / HEMA 45%, canforoquinona 0,5% e DMAEMA 0,5%. O grau de conversão (GC) dos monômeros foi avaliado por Espectroscopia micro-Raman (GC : EGCG 1.5 - 99,11a; EGCG 1.0 - 99,02a; EGCG 0.5 - 96,58ab; Controle - 85,47b). A segunda etapa envolveu a realização de análises mecânicas e físico-químicas [resistência flexural (RF) e módulo de elasticidade (ME); módulo de resiliência (RE) e resistência a compressão(RCo); sorção (A) e solubilidade (S) em água; contração de polimerização (CP)]; teste de resistência à microtração (RA) imediato (24 h) e longitudinal (6 meses); e teste biológico [ensaio de citotoxicidade (CI)]. Os resultados foram: RF, ME, RE, RCo e CP não apresentaram diferença significativa entre os grupos. Os testes de A e S apresentaram redução dos valores para os grupos EGCG 0.5 e 1.0; RA imediato (24 h) não apresentou diferença entre os grupos. Após 6 meses houve redução dos valores somente para os grupos Controle e EGCG 1.5, os grupos EGCG 0.5 e 1.0 mantiveram os valores de RA constantes. CI: a incorporação de EGCG aumentou a viabilidade celular nas diluições de 0,1% e 1,0%, comparado ao grupo Controle. Pôde-se concluir que a incorporação de EGCG independente da concentração não afetou o GC. As concentrações de 0,5% (100 μg/ml) e 1,0% (200 μg/ml) em volume de EGCG é capaz de preservar a camada híbrida formada e prorrogar a longevidade das restaurações em resina composta, além de aumentar a viabilidade celular / Abstract: The aim of this study was to evaluate the effect of EGCG in an experimental adhesive to reduce the hybrid layer degradation, through mechanical, physical-chemical and biological analysis. The first step of this study involved manipulation of the adhesive model with the incorporation three different concentrations of EGCG (0.5%, 1.0% and 1.5%) in relation BisGMA 55% / 45% HEMA, 0.5% camphorquinone and 0.5% DMAEMA. The conversion degree (DC) of adhesive monomers was evaluated by micro-Raman spectroscopy (GC: EGCG 1.5 (1.5%) - 99,11a; EGCG 1.0 (1.0%) - 99,02a; EGCG 0.5 (0.5%) - 96,58ab; Control - 85,47b). The second step involved the mechanical and physicochemical analysis [flexural strength (FS) and elastic modulus (EM); resiliency modulus (RM) and compressive bond strength (CBS), sorption (A) and solubility (S) in water; shrinkage polymerization (SP)]; microtensile bond strength test (μTBS) immediately (24 h) and longitudinal (6 months) and biological analyze [cytotoxicity assay (CY)]. The results were: FS, EM, RM, CBS and SP showed no significant difference between groups; A and S tests showed reduced values only for EGCG 0.5 and 1.0 groups. RA immediately (24) did not differ between groups. After six months there was a reduction of the values only for the control and EGCG 1.5 groups, EGCG groups 0.5 and 1.0 maintained the RA values. CY: EGCG incorporation increased the cell viability in 0.1% and 1.0% dilutions compared to the control group. It was concluded incorporation of EGCG at 0.5, 1.0 and 1.5 concentrations did not affect the degree of conversion of the monomers. Thus, the incorporation of 0.5% (100 μg/ml) and 1.0% (200 μg/ml) EGCG amount can preserve the hybrid layer formed and prolong longevity composite resin restorations in addition to increasing cell viability. / Doutor
118

Análise da efetividade de polimerização, adaptação marginal e interna de restaurações Classe II de resinas compostas de inserção em bloco utilizando diferentes matrizes /

Gutierrez, Natália Cortez. January 2016 (has links)
Orientador: Carlos Rocha Gomes Torres / Banca: Eduardo Bresciani / Banca: Taciana Marco Ferraz Caneppele / Banca: Roberta Tarkany Basting Höfling / Banca: Sérgio Ricardo Garcia Badini / Resumo: O objetivo deste estudo foi analisar a efetividade de polimerização, a adaptação marginal e interna de resinas compostas para dentes posteriores, empregando diferentes matrizes associadas ao envelhecimento artificial. Cento e vinte incisivos bovinos foram cortados e desgastados para simular dentes posteriores, nos quais foram realizados preparados de Classe II, com o ângulo cavosuperficial gengival em dentina. As cavidades tinham 6 mm de altura (ocluso-cervical), 3 de largura (vestibulo-lingual) e 1,5 de profundidade (mesio-distal). Os espécimes foram divididos em seis grupos de acordo com o material restaurador utilizado: GrandioSO (Voco)- convencional incremental, G-aenial universal flo (GC)- fluída incremental, Xtra fil (Voco)- convencional com inserção em bloco, X-tra base (Voco)- fluída com inserção em bloco, Venus Bulk Fill (Kulzer)- fluída com inserção em bloco e SureFil SDR (Dentsply)- fluída com inserção em bloco. As resinas fluídas com inserção em bloco foram inseridas em incremento de 4 mm e receberam uma cobertura oclusal de 2 mm utilizando a resina GrandioSO, com exceção da X-tra fil que foi coberta com uma camada adicional do mesmo material. Nos demais grupos foi utilizada uma técnica incremental de 2 mm. Metade dos espécimes foi restaurada com matriz metálica e a outra metade com matriz de poliéster. O percentual de polimerização foi mensurado através da dureza Knoop e da relação dureza base/topo. A média da largura das fendas marginais presentes nas margens de cada restauração foi calculada após medição, em micrometros, no microscópio óptico (100x). Os espécimes foram submetidos à ciclagem mecânica (500,000 ciclos) e térmica (1,000 ciclos) e a fenda marginal foi avaliada novamente. Para fenda interna, os espécimes foram seccionados em uma cortadeira de precisão e o comprimento, em milímetros, da parede gengival que apresentava fenda foi mensurado no microscópio óptico... / Abstract: The aim of this study was to analyze the effectiveness of cure, marginal and internal adaptation of composite resins for posterior teeth using different matrices bands associated with artificial aging. One hundred and twenty bovine incisors were cut and flattened in order to simulate posterior teeth, and then were prepared for class II cavities with gingival cavosurface margin in dentin. Cavities had 6 mm height (occluso-cervical), 3 mm width (bucco-lingual) and 1.5 mm deep (mesio-distal). Specimens were divided into six groups according to the restorative material: GrandioSO (Voco)- conventional, G-aenial universal flo (GC)- flowable, X-tra fil (Voco)- conventional bulk, X-tra base (Voco)- flowable bulk, Venus Bulk Fill (Kulzer)- flowable bulk, and SureFil SDR (Dentsply)- flowable bulk. Bulk-fill composites were placed in single increment of 4mm and received a 2mm occlusal coverage of GrandioSO, with the exception of X-tra fil which was covered with a layer of the same material. The remmaing groups were restored in 2 mm incremental technique. Half of the specimens were restored with metallic and the other half with polyester matrix. Effectiveness of cure was measured by Knoop hardness and the bottom/top hardness ratio was evaluated. The average width of marginal gaps present in the restoration was calculated after optical microscope measuring (100x), in microns. The specimens were subjected to mechanical (500.000 cycles) and thermal cycling (1.000 cycles) and marginal gap was evaluated again. For internal adaptation, the specimens were sectioned and the gap length, in millimeters, present on the gingival wall was measured in an optical microscope. The percentage of gap length in relation to the total length of the wall was also calculated. Data were analyzed with three and two-way ANOVA and Tukey's test. Regarding effectiveness of cure, significant differences were observed for resin... / Doutor
119

Efeito do selamento, reparo e recontorno sobre a longevidade de restaurações de resina composta em dentes posteriores segundo critério USPHS/RYGE

Fernández Godoy, Eduardo Maximiliano. January 2015 (has links)
Orientador: Osmir Batista de Oliveira Junior / Co-orientador: / Banca: Hermes Pretel / Banca: Andréa Abi Rached Dantas / Banca: Cláudia Silami de Magalhães / Banca: Allyson Nogueira Moreira / Resumo: O objetivo geral deste trabalho foi determinar o efeito de selamento marginal, recontorno e reparo sobre a longevidade de restaurações de resina composta em dentes posteriores segundo Critério USPHS/Ryge. Foi realizado estudo experimental, longitudinal, prospectivo triplo-cego, incluímos 107 restaurações de resina composta de um grupo de 26 pacientes, de ambos os gêneros. Todos os pacientes foram recrutados na clínica da faculdade de Odontologia da Universidade do Chile em 2003 de acordo com os seguintes critérios de inclusão: apresentar restaurações de resina composta em dentes posteriores com defeitos, apresentando uma ou mais características clínicas classificadas como Bravo ou Charlie acordo com critérios USPHS/Ryge.Foram constituídos os seguintes grupos experimentais: 1.- Selamento, 2.- recontorno, 3.- Reparação, 4.- substituição, 5.- Sem intervenção.Os dentes dos voluntários foram avaliados e classificados pelo critério USPHS/Ryge por dois examinadores treinados e calibrados (0.75), A longevidade das restaurações foi avaliada antes da intervenção e após 1, 2, 3, 4, 5 e 10 anos de observação. Resultados, em geral, os grupos estudados mostraram restaurações clinicamente aceitáveis após dez anos de acompanhamento. O selamento e o recontorno mostraram efeito de melhoria imediata, que se perdeu ao longo do tempo (p<0.05). O reparo foi efetivo e apresentou resultados semelhantes a substituição total da restauração após 10 anos de uso clínico (p>0.05). Conclusão: O reparo aumentou a longevidade da restauração de resina composta em dentes posteriores por 10 anos enquanto o recontorno e o selamento marginal mostraram benefícios somente até 4 anos. Estes procedimentos minimamente invasivos mostraram-se validos e poderiam ser adotados pelos programas de saúde pública e pela faculdade...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to determine the effect of marginal sealing, refurbishing and repair on the longevity of composite resin restorations in posterior teeth by criteria USPHS / Ryge. This clinical trial was longitudinal, tripleblind prospective. Were included 107 composite restorations of a group of 26 patients, of both genders. All patients were recruited in the clinic of Dentistry faculty of the University of Chile in 2003 according to the following inclusion criteria: presenting composite restorations in posterior teeth with defects, showing one or more clinical features classified as Bravo or Charlie according to USPHS / Ryge. According following criteria constituted the groups: 1.-Sealing, 2.-Refurbished 3. Repair, 4. No treatment and 5. Replacement. The restorations were evaluated and classified by USPHS criteria / Ryge by two trained and calibrated examiners (kappa 0.75), longevity of restorations was evaluated before the intervention and after 1, 2, 3, 4, 5 and 10 years. Results, in general, the groups showed restorations values acceptable to the ten year follow-up in the repair group, sealed and refurbished, the improvements were immediate and the effect remained se. Conclusions: Alternative treatments repair, sealing and refurbishing were able to improve some parameters deteriorated...(Complete abstract electronic access below) / Doutor
120

Comparação da rugosidade após abrasão por escovação e da microdureza entre resinas compostas nanoparticuladas e microhíbrida

Rosa, Rogério Simões January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:07Z (GMT). No. of bitstreams: 2 000386619-0.pdf: 4143713 bytes, checksum: 264c046972f7bb6da411606f1d2ba903 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The objective of this in vitro study was to evaluate the surface roughness after three body wear and Vickers microhardness of direct composite resins with different sizes of inorganic filler particles, microhybrid Z250 and nano-filled Z350 and Supreme XT, which are fabricated by one company (3M ESPE, St Paul, Minessota, USA). Six specimens (n=6) of each composite resin were manufactured to be evaluated, in sequence, in each one of control, 6 months, 1 year and 2 years simulated toothbrushing periods. Three measurements of surface roughness Ra (μm) were realized for specimen after each simulation. One representative specimen was manufactured to each composite resin tested in each simulated toothbrushing period to be examinated in SEM. The minimums and maximums means values were 0. 14 μm control group Z350 composite resin and 0. 21 μm 1 year simulated toothbrushing period Z250. Were analyzed with ANOVA and Tukey ( =0. 05) and there was no significant statistically difference between the groups. The General Linear Model and Tukey ( =0. 05) was applied, with purpose to evaluated composite resin and time factors in surface roughness Ra (μm). There was significant statistically difference of control time roughness (0. 15 μm) in regard to 1 year time roughness (0. 19 μm), about the kind of composite resin, both nano-filled composite resins (0. 16 μm) had more homogeneous surface after three body wear than microhybrid (0. 19 μm).The photomicrographs did not show any difference among the three composite resins control group. However, the nano-filled 6 months, 1 year and 2 years simulated toothbrushing periods photomicrographs showed the most homogeneous surface. For Vickers microhardness, 5 specimens of each composite resin were manufactured (n=5). Means for Vickers microhardness (VHN) were: Z250 74. 44; Z350 73. 87; XT 78. 28. Data were statistically compared with ANOVA, and there was no significant difference between the means. The results of this study indicate that the nano-filled composite resins showed a similar behavior to microhybrid for Vickers microhardness, but had more homogeneous surface after three body wear. / O objetivo deste estudo in vitro foi avaliar a rugosidade após abrasão por escovação de corpo triplo e a microdureza Vickers de resinas compostas para uso direto com diferentes tamanhos de partículas de carga inorgânica, como a microhíbrida Z250 e as nanoparticuladas Z350 e Supreme XT, de mesma marca comercial (3M ESPE, St Paul, Minessota, EUA). Seis corpos-de-prova (n=6) foram confeccionados para cada resina composta (Supreme XT, Z250 e Z350) e submetidos, na seqüência, a cada período simulado de escovação (controle, 6 meses, 1 ano e 2 anos). Foram realizadas 3 leituras de rugosidade de superfície Ra (μm) em cada amostra após cada simulação (total=216). Foi confeccionado 1 corpode- prova representativo de cada período simulado de escovação para cada resina composta (total=12), a fim de que fosse observado em MEV. Os valores médios mínimos e máximos obtidos foram, respectivamente, de 0,14 μm (controle) para a resina Z350 e 0,21 μm (1 ano) para a resina Z250. Foi aplicada a análise de variância, seguida do teste de Tukey ( =0,05) e constatou-se que não houve diferença estatisticamente significante entre os grupos. A fim de avaliar a rugosidade em relação ao tempo e ao tipo de resina composta testada foi aplicado o modelo linear geral, seguido do teste de Tukey ( =0,05). Observou-se uma diferença estatisticamente significante da rugosidade no período controle (0,15 μm) em relação ao período de 1 ano (0,19 μm), com relação ao tipo de resina, ambas nanoparticuladas (0,16 μm) apresentaram-se significativamente menos rugosas que a microhíbrida (0,19 μm). Os aspectos morfológicos superficiais obtidos em MEV mostram que houve padrões semelhantes de desgaste entre as resinas compostas nos grupos controle. Após os períodos simulados de escovação de 6 meses, 1 ano e 2 anos, observou-se uma surperfície mais uniforme para as resinas compostas nanoparticuladas em relação à microhíbrida. Para a microdureza Vickers, 5 amostras para cada resina composta foram confeccionadas (n=5). As médias (VHN) foram: Z250 74,44; Z350 73,87; XT 78,28. Após análise de variância, observou-se que não houve diferença significante entre elas. Baseado nos resultados, concluiu-se que as resinas compostas nanoparticuladas (Z350, Supreme XT) obtiveram comportamento similar à microhíbrida (Z250) quanto à microdureza Vickers, porém, se apresentaram menos rugosas após a abrasão por escovação.

Page generated in 0.0578 seconds