Spelling suggestions: "subject:"computergestützte chirurgie"" "subject:"computergestützte dagchirurgie""
1 |
Effect of surgical experience on imageless computer-assisted femoral component positioning in hip resurfacing – a preclinical studyStiehler, Maik, Goronzy, Jens, Kirschner, Stephan, Hartmann, Albrecht, Schäfer, Torsten, Günther, Klaus-Peter 17 July 2015 (has links) (PDF)
Background:
The clinical outcome of hip resurfacing (HR) as a demanding surgical technique associated with a substantial learning curve depends on the position of the femoral component. The aim of the study was to investigate the effects of the level of surgical experience on computer-assisted imageless navigation concerning precision of femoral component positioning, notching, and oversizing rate, as well as operative time.
Methods:
Three surgeons with different levels of experience in both HR and computer-assisted surgery (CAS) prepared the femoral heads of 54 synthetic femurs using the Durom
TM Hip Resurfacing (Zimmer, Warsaw, IN, USA) system. Each surgeon prepared a total of 18 proximal femurs using the Navitrack® system (ORTHOsoft Inc., Montreal,
Canada) or the conventional free-hand Durom TM K-wire positioning jig. The differences between planned and postoperative stem shaft angle (SSA) and anteversion angle in standardized x-rays were measured and the operative time, not including the time for calibrating the CAS-system, was documented. Notching was evaluated by the three surgeons in a randomized manner. Oversizing was determined by the difference of the preoperative determined cap and the cap size advised by the CAS-system.
Results:
CAS significantly reduced the overall mean deviation between planned and postoperative SSA in comparison with the conventional procedure (mean ± SD, 1 ± 1.7° vs. 7.4 ± 4.4°, P <0.01) regardless of the surgeon’s level of experience. The incidence of either varus or valgus SSA deviations exceeding 5° were 1/27 for CAS and 15/27 for the conventional method, respectively (P<0.001), corresponding to a reduction by 97%. Using CAS, the rate of notching was reduced by 100%.
Conclusions:
The accuracy of femoral HR component orientation is significantly increased by use of CAS regardless of the surgeon’s level of experience in our preclinical study. Thus, imageless computer-assisted navigation can be a valuable tool to improve implant positioning in HR for surgeons at any stage of their learning curve.
|
2 |
Effect of surgical experience on imageless computer-assisted femoral component positioning in hip resurfacing – a preclinical studyStiehler, Maik, Goronzy, Jens, Kirschner, Stephan, Hartmann, Albrecht, Schäfer, Torsten, Günther, Klaus-Peter 17 July 2015 (has links)
Background:
The clinical outcome of hip resurfacing (HR) as a demanding surgical technique associated with a substantial learning curve depends on the position of the femoral component. The aim of the study was to investigate the effects of the level of surgical experience on computer-assisted imageless navigation concerning precision of femoral component positioning, notching, and oversizing rate, as well as operative time.
Methods:
Three surgeons with different levels of experience in both HR and computer-assisted surgery (CAS) prepared the femoral heads of 54 synthetic femurs using the Durom
TM Hip Resurfacing (Zimmer, Warsaw, IN, USA) system. Each surgeon prepared a total of 18 proximal femurs using the Navitrack® system (ORTHOsoft Inc., Montreal,
Canada) or the conventional free-hand Durom TM K-wire positioning jig. The differences between planned and postoperative stem shaft angle (SSA) and anteversion angle in standardized x-rays were measured and the operative time, not including the time for calibrating the CAS-system, was documented. Notching was evaluated by the three surgeons in a randomized manner. Oversizing was determined by the difference of the preoperative determined cap and the cap size advised by the CAS-system.
Results:
CAS significantly reduced the overall mean deviation between planned and postoperative SSA in comparison with the conventional procedure (mean ± SD, 1 ± 1.7° vs. 7.4 ± 4.4°, P <0.01) regardless of the surgeon’s level of experience. The incidence of either varus or valgus SSA deviations exceeding 5° were 1/27 for CAS and 15/27 for the conventional method, respectively (P<0.001), corresponding to a reduction by 97%. Using CAS, the rate of notching was reduced by 100%.
Conclusions:
The accuracy of femoral HR component orientation is significantly increased by use of CAS regardless of the surgeon’s level of experience in our preclinical study. Thus, imageless computer-assisted navigation can be a valuable tool to improve implant positioning in HR for surgeons at any stage of their learning curve.
|