• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 171
  • 122
  • 21
  • 13
  • 11
  • 6
  • 5
  • 5
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 592
  • 141
  • 133
  • 84
  • 73
  • 57
  • 57
  • 55
  • 53
  • 51
  • 50
  • 42
  • 40
  • 38
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Estabelecimento de um novo metodo de calibracao de camaras de ionizacao tipo lapis para dosimetria em feixes de tomografia computadorizada / Establishment of a new calibration method of pencil ionization chamber for dosimetry in computed tomography

DIAS, DANIEL M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:45Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:14Z (GMT). No. of bitstreams: 0 / As câmaras de ionização tipo lápis são utilizadas para dosimetria de feixes em equipamentos de tomografia computadorizada (CT). Neste estudo foi estabelecida uma nova metodologia de calibração destas câmaras, visando a adequação do Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares (LCI) aos atuais padrões metrológicos internacionais que tratam dos procedimentos específicos para calibração das câmaras utilizadas em CT. Primeiramente partiu-se da implantação das novas qualidades de radiação padrão RQT, que simulam feixes não atenuados usados para aplicações em CT, de acordo com a IEC 61267 da International Electrotechnical Commission (IEC). Após o estabelecimento dos campos padrões de radiação, foi implantada a metodologia de calibração específica para câmaras lápis segundo o Technical Report Series No. 457, da International Atomic Energy Agency (IAEA), que descreve as particularidades do procedimento a ser seguido pelos Laboratórios de Dosimetria Padrão Secundário (SSDLs) em termos de colimação e posicionamento em relação ao feixe de radiação. Inicialmente, foram realizadas medições de PPV (kV) e determinação das filtrações adicionais de cobre por meio dos valores de camada semi-redutora (CSR) recomendados pela norma IEC 61267, para que as qualidades de radiação de referência: RQT 8, RQT 9 e RQT 10 fossem implantadas. Para os filtros adicionais, foram utilizados alumínio e cobre de alta pureza (maior ou igual a 99,9%). Uma metodologia alternativa para determinar as filtrações adicionais também foi utilizada, através da qual se encontrou diretamente as RQTs em espessuras de filtros de cobre equivalente ao conjunto RQR (Al) + Filtração Adicional (Cu), sendo esta uma opção quando não se têm implantadas as RQRs. Com a implantação desta nova metodologia de calibração das câmaras de ionização tipo lápis, o LCI está pronto para calibrar estes instrumentos de acordo com as recentes recomendações internacionais. Permitindo assim uma melhoria na rastreabilidade das calibrações, como também na qualidade dos serviços metrológicos que o IPEN oferece para todo o País. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
82

Desenvolvimento de um sistema de tomografia por coerencia optica no dominio de Fourier sensivel a polarizacao e sua utilizacao na determinacao das matrizes de mueller / Development of an polarization sensitive Fourier domain optical coherence tomography and it utilization on the Mueller matrix determination

RAELE, MARCUS P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:57Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:18Z (GMT). No. of bitstreams: 0 / Este estudo abordou os aspectos teóricos e experimentais relacionados ao desenvolvimento de um sistema de tomografia por coerência óptica (OCT) no domínio de Fourier sensível à polarização (PS-FD-OCT) e a sua utilização na determinação da Matriz de Mueller (MM-OCT). O estudo iniciou-se com uma revisão bibliográfica que abordou desde os primeiros estudos relacionados à técnica até o estado da arte, bem como o formalismo matemático da interferometria de baixa coerência no domínio espectral e polarização da luz. Realizaram-se estudos baseados em simulação numérica sobre três tipos diferentes de algoritmos, responsáveis pela recuperação do sinal de espalhamento, sendo eles: a Transformada de Fourier Direta; Interpolação e Zero-Filling. Ao fim dessa etapa concluiu-se que o algoritmo Zero-Filling 2N apresentou melhores características quando comparado aos outros algoritmos. Na parte experimental, primeiramente, diferentes arranjos OCT foram montados e medidas realizadas para verificação aspectos relacionados à teoria. Consecutivamente, utilizando uma amostra polimérica, realizaram-se imagens de birrefringência, que permitiram a determinação da birrefringência da amostra quantitativamente. Finalmente, imagens em diferentes estados de polarização foram realizadas, através delas determinou-se as imagens referentes aos elementos das Matrizes de Mueller, que foram analisadas individualmente. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
83

Caracterizacao de um modelo de camada limite planetaria para avaliar liberacoes de radionuclideos em instalacoes nucleares

MOLNARY, LESLIE de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:37:42Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:15Z (GMT). No. of bitstreams: 1 12905.pdf: 6893791 bytes, checksum: 505c8ae6d27e32929e2edfaa656b4e81 (MD5) / Dissertacao (Mestrado) / IEA/D / Instituto Astronomico e Geofisico, Universidade de Sao Paulo - IAG/USP
84

Simulação semi-empírica da resposta termoluminescente sob diferentes geometrias de filtro

SHAMMAS, GABRIEL I.J. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:24Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:17Z (GMT). No. of bitstreams: 0 / Muitos materiais termoluminescentes têm sido desenvolvidos e utilizados para a monitoração individual externa de fótons, mas nenhum tem todas as características desejadas sozinho. Estas características incluem robustez, alta sensibilidade, independência de resposta quanto à energia do fóton, larga faixa de detecção de energia, boa reprodutibilidade, evanescência pequena e curva de emissão termoluminescente simples, com picos abaixo de 150oC. O dosímetro de sulfato de cálcio dopado com disprósio CaSO4:Dy) tem sido usado por muitos laboratórios, principalmente no Brasil e na Índia. Outro fósforo interessante é o fluoreto de cálcio (CaF2). As vantagens destes fósforos começam a ser mais requisitadas e suas desvantagens mais aparentes, no mercado globalizado mais e mais competitivo. Estes fósforos são utilizados em monitoração de área e ambiental devido à sua maior sensibilidade do que outros fósforos, como o LiF:Mg. A sua maior desvantagem é a forte dependência energética da resposta, que deve ser corrigida para suas aplicações em campo, onde o fóton é desconhecido a priori. Um modo interessante de fazer esta correção numa incidência ortogonal da radiação no fósforo é a interposição de um filtro plano vazado entre o feixe e o fósforo. Com o objetivo de reduzir a dependência energética sob incidência em qualquer ângulo, reduzindo a incerteza de medição da dose em campo também, este trabalho apresenta um estudo de simulação em geometrias de filtro esféricas. Foram simuladas irradiações de fótons com raios gama do cobalto 60, com raios-X de 33, 48 e 118 keV, em vários ângulos de incidência de zero a noventa graus. Estas simulações computacionais semi-empíricas, utilizando diferenças finitas em três dimensões, foram feitas em coordenadas esféricas. Os resultados indicaram as melhores espessuras e larguras para a otimização da correção da dependência energética. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
85

Modelamento matematico e simulacao computacional do processo de nitretacao de acos

POLITANO, RODOLFO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:48:10Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:51Z (GMT). No. of bitstreams: 1 09314.pdf: 4165568 bytes, checksum: 1f807085172cb5f0db4904459a6e288b (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
86

Contribuição ao modelamento e simulação de motores com imãs permanentes e comutação eletrônica de alta rotação

SILVA, WANDERLEI M. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:14Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:14Z (GMT). No. of bitstreams: 1 12437.pdf: 4743815 bytes, checksum: 224eec9c107091a47a85eb64ff2540c5 (MD5) / Dissertacao (Mestrado) / IPEN/D / Escola Politecnica, Universidade de Sao Paulo - POLI/USP
87

Estudos dos precursores de ozônio da cidade de São Paulo através de simulação computacional / A study about the ozone precursors in the São Paulo city using computational simulation

ORLANDO, JOAO P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:30Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:22Z (GMT). No. of bitstreams: 0 / O ozônio (O3) representa o principal poluente atmosférico para a Região Metropolitana de São Paulo (RMSP), sendo freqüentes os dias em que sua concentração excede os padrões nacionais de qualidade do ar. Por se tratar de um poluente secundário, resultante principalmente, da interação entre os óxidos de nitrogênio (NOx) e compostos orgânicos voláteis (COVs) na presença de luz solar, torna-se muito difícil a elaboração de estratégias eficazes para a redução deste poluente. A utilização de simulação computacional se mostra como uma interessante alternativa para avaliar os muitos fatores que afetam a formação de O3, para o desenvolvimento de escalas de reatividade para COVs e para definição de possíveis estratégias que visem a redução dos níveis de O3. Neste trabalho foi utilizado o modelo de trajetórias OZIPR (Ozone Isopleth Package for Research) em conjunto com o modelo químico SAPRC (Statewide Air Pollution Research Center) para se determinar a escala de reatividade incremental para COVs para a cidade de São Paulo e para a simulação de diversas situações de redução das emissões de NOx e COVs. Para alimentar os modelos foram utilizadas medidas de COVs de duas campanhas: uma realizada pelo Laboratório de Química Atmosférica (LQA-IPEN) em conjunto com a CETESB na estação Cerqueira César, no período de agosto e setembro de 2006 e outra realizada somente pelo LQA durante todo o ano de 2006 com amostragens na Cidade Universitária. Dados de CO, NOx e parâmetros meteorológicos foram obtidos através dos monitores automáticos da mesma estação e da estação Pinheiros. Foram criados cinco casos base: um com os dados de COVs da estação Cerqueira César e quatro com os dados da Cidade Universitária, sendo estes, um para cada estação do ano. Após o ajuste dos casos base, cada COV presente na mistura teve sua concentração aumentada e diminuída em 0,2% dos COVs totais para se verificar a variação no máximo de ozônio e assim se determinar o potencial de formação de ozônio de cada COV. Estes resultados forneceram uma escala de reatividade para ozônio para cada caso base criado. Foram também realizadas simulações, onde as emissões horárias de NOx e COVs foram reduzidas em 5, 10, 20 e 30% independente e simultaneamente afim de se verificar as variações na formação de O3. Com os dados de saída do simulador foram construídos gráficos de isopletas de ozônio para a cidade de São Paulo. A análise dos resultados obtidos mostrou que os compostos encontrados com mais freqüência entre os dez principais precursores de ozônio na cidade de São Paulo nas escalas de reatividade criadas a partir dos cinco casos base são: formaldeído, acetaldeído, propeno, isopreno, cis e trans 2-buteno, sendo o formaldeído sempre o principal composto formador de ozônio. As simulações mostraram também que uma estratégia eficaz para se reduzir os níveis de O3 na cidade de São Paulo é diminuir as emissões totais de COVs. O mesmo não foi observado para os NOx, já que a redução destes poluentes faria aumentar as concentrações de O3. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP
88

Modelagem e simulacao do processo de atomizacao na industria de revestimento ceramico

FAVALLI, RENATA C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:46:58Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:27Z (GMT). No. of bitstreams: 1 07981.pdf: 5585359 bytes, checksum: c0160291db44ef247a97d5737dda9a36 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:96/11957-7
89

Efeitos do colimador na qualidade de imagem em tomografia industrial de terceira geração / Collimator effects on image quality in industrial tomography third generation

CARVALHO, DIEGO V. de S. 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T11:06:37Z No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T11:06:37Z (GMT). No. of bitstreams: 0 / O estudo do efeito da colimação nos detectores de radiação sobre a qualidade de imagem do tomógrafo industrial de terceira geração desenvolvido no IPEN/CNEN-SP é descrito neste trabalho. Três conjuntos de colimadores de chumbo foram projetados e confeccionados, sendo um com janelas retangulares de 2 x 5 x 50 mm e outro com 4 x 10 x 50 mm (largura x comprimento x profundidade) e um terceiro com orifício circular de 5 mm de diâmetro x 40 mm de profundidade. Os colimadores foram projetados para poderem ser facilmente substituídos entre si nos detectores de radiação. Paralelamente, foram confeccionados e utilizadas a eletrônica associada, constituída de analisadores de sinais tipo multicanal de 8 bits contendo a unidade de alta tensão e o amplificador. Dentre as vantagens deste sistema destaca-se a sua capacidade de análise multicanal rápida e possuir uma eletrônica mais simples. Valores de resolução energética comparável com a da literatura foram encontrados utilizando a eletrônica desenvolvida acoplada ao detector de radiação de NaI(Tl). Os efeitos dos colimadores foram avaliados pelas medidas tomográficas em um fantom de polimetilmetacrilato contendo componentes multifásicos estáticos (ferro, alumínio e ar). Fontes de radiação com energias de das fontes de 75Se (97 keV, 121 keV, 136 keV, 265 keV, 279 keV e 400 keV), de 137Cs (662 keV) e de 192Ir (317 keV, 468 keV e 602 keV) observou-se que a melhor imagem do fantom foi obtida com os colimadores de janelas retangulares (fendas) de 2 x 5 x 50 mm. Na avaliação dinâmica da formação de bolhas em coluna simuladora de processos industriais, a melhor imagem foi obtida com a fonte de 192Ir. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
90

Teoria e experimentação com metodos incrementais relaxados em tomografia por emissão / Theory and experimentation with relaxed incremental methods in emission tomography

Helou Neto, Elias Salomão 04 December 2005 (has links)
Orientador: Alvaro Rodolfo De Pierro / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Matematica, Estatistica e Computação Cientifica / Made available in DSpace on 2018-08-14T01:15:10Z (GMT). No. of bitstreams: 1 HelouNeto_EliasSalomao_M.pdf: 1733678 bytes, checksum: 44e680915a74638897d279b1d09a007f (MD5) Previous issue date: 2005 / Resumo: O principal assunto desta dissertação é a teoria e prratica em metodos iterativos incrementais relaxados para reconstrução estatística de imagens em Tomografia por Emissão de Positrons - PET. Especial atenção é dedicada ao estudo teorico dos algoritmos, com a apresentação de resultados novos sobre convergência com o parâmetro de relaxação variando dentre as subiterações e sobre a regularidade da sequência gerada por tais algoritmos no caso específico da função de log-verossimilhança que surge em PET. Alem disso, uma comparação experimental entre a qualidade da imagem obtida com metodos relaxados e não relaxados é efetuada / Abstract: The main subject of this dissertation is the theory and practice in iterative incremental relaxed methods for statistical image reconstruction in Positron Emission Tomograpy | PET. Special atention is drawn to the theoretical study of the algorithms, with the presentation of new results concerning convergence with a relaxation parameter wich is allowed to vary within the subiterations and about the regularity of the sequence generated by such algorithms in the specific case of the log-likelihood function that arises in PET. Furthermore, an experimental comparsion is made to test the quality of the image obtained with relaxed methods against those generated by non-relaxed ones / Mestrado / Mestre em Matemática Aplicada

Page generated in 0.0841 seconds