Spelling suggestions: "subject:"connector"" "subject:"conectar""
21 |
Análise teórica e experimental de pisos mistos de pequena altura compostos por vigas metálicas e lajes alveolares de concreto / Theoretical and experimental analysis of slim floor systems composed by steel beam and concrete hollow core slabsPatricia Tavares de Souza 22 March 2016 (has links)
No mercado mundial existe uma visível tendência de tornar as obras mais industrializadas e racionalizadas com o objetivo de reduzir os desperdícios, acelerar a velocidade de execução das obras e garantir maior qualidade às mesmas. A adoção de elementos estruturais com certo grau de industrialização pode trazer benefícios em relação aos custos, à mão de obra, ao tempo de execução e ao impacto ambiental. Neste contexto, as estruturas mistas de aço e concreto satisfazem essa necessidade, pois tanto os elementos de aço quanto os elementos de concreto podem ser pré-fabricados, ficando apenas as etapas de içamento e montagem a serem realizadas na obra, reduzindo o uso de fôrmas e escoramentos. Os pisos mistos de aço e concreto de pequena altura caracterizam-se pelo embutimento da laje de concreto na altura do perfil de aço, sendo a principal vantagem, em relação ao piso misto convencional, a redução da altura total do composto. Portanto, este trabalho tem como objetivo analisar o comportamento de pisos mistos de aço e concreto de pequena altura com laje alveolar em concreto protendido por meio de ensaios de cisalhamento direto (push-out test) e de flexão. Na solução proposta, a transferência de esforços entre o perfil de aço e a laje alveolar foi feita por meio de conectores tipo pino com cabeça e concreto moldado no local. Os resultados demonstraram-se promissores em termos de comportamento do piso misto de pequena altura, aumentando significativamente a rigidez do sistema em relação à viga de aço isolada. Em complemento, foi desenvolvida uma simulação numérica dos modelos físicos ensaiados utilizando o pacote computacional DIANA®, fundamentado no método dos elementos finitos, na qual o modelo numérico representou adequadamente o comportamento dos pisos mistos de pequena altura, permitindo análises paramétricas. / On the world market, there is a visible tendency to turn buildings construction more industrialized and rationalized in order to reduce waste, accelerate the construction speed and ensure higher quality to them. The adoption of structural elements with a degree of industrialization can bring benefits regarding costs, labor, construction time and environmental impact. In this context, steel and concrete composite structures satisfy this need, since steel and concrete elements can be prefabricated, with only lifting and mounting steps to be performed on site, reducing use of formwork and shoring. A type of slim floor system consists in precast concrete hollow core slabs supported on the lower flange of steel beams. The major advantage of this solution, compared to conventional composite beam, is reducing the overall height of the floor. Therefore, this study aims to analyze the behavior of slim floor with prestressed concrete hollow core slabs through push-out and bending tests. In the proposed solution, the transfer of forces between steel beam and hollow core slabs was made by stud bolts and cast on site concrete. The obtained results proved to be promising in terms of slim floor behavior, significantly increasing the system stiffness regarding the isolated steel beam. In addition, a numerical modeling of the studied slim floor system was developed, using finite element based software DIANA®, in which the numerical model adequately represented the behavior of the composite beam, allowing parametric analysis.
|
22 |
Mejora del transbordo Corredor Rojo-Metro de Lima por medio de un conector peatonal en la intersección de la Av. Javier Prado con Av. Aviación / Improvement of the transhipment “Corredor Rojo”-Lima’s Metro by a pedestrian connector at the intersection of Javier Prado Avenue with Aviacion AvenueAsenjo Albitres, Christian, Tocas Morales, Frank Anthony 19 November 2020 (has links)
La realidad peruana refleja una falta de integración de los sistemas de transporte. Asimismo, se evidencia bajos estándares de calidad con relación a las infraestructuras urbanas y una inseguridad hacia el peatón en la ciudad de Lima, un ejemplo de lo mencionado ocurre en la intersección de la Avenida Javier Prado con Aviación.
Mediante el software Vissim-Visswalk 9 se realiza una microsimulación que refleja las trayectorias, frecuencias y composiciones vehiculares y peatonales, la cual se calibra y valida respectivamente.
La metodología propuesta describe una delimitación de la intersección mencionada, luego se realiza la clasificación de usuarios de transportes públicos y tipos de vehículos para proceder al levantamiento de información dinámica en cuanto al aforo de vehículos y peatones y posteriormente registrarlas en el Vissim-Viswalk 9.
De manera cualitativa, la seguridad vial se evalúa mediante la utilización de listas de chequeo las cuales reflejan claramente una inseguridad y alta vulnerabilidad hacia la integridad del peatón evidenciado en los 13 ítems analizados.
La propuesta de solución consiste en el diseño de un conector peatonal de 320 metros, el cual cumple con los reglamentos requeridos ya que tiene un ancho efectivo constante de 1.6 metros y una pendiente máxima de 5% y 10% en el conector y en la rampa, respectivamente.
Los resultados demuestran que la propuesta permite una reducción del tiempo de transbordo en un 17.1% y un aumento en la velocidad promedio de 26.1%, asimismo se evidencia un aumento significativo de la seguridad vial hacia los peatones. / Peruvian reality reflects a lack of integration of transport systems. In addition, low quality standards are evident in relation to urban infrastructures and a pedestrian insecurity in the city of Lima, an example of what is mentioned at the intersection of Avenida Javier Prado with Aviacion.
The Vissim-Visswalk 9 software performs a microsimulation that reflects the trajectories, frequencies and vehicular and pedestrian compositions, which is calibrated and validated respectively.
The proposed methodology describes a delimitation of the mentioned intersection, then the classification of public transport users and vehicle types is carried out to carry out dynamic information regarding the capacity of vehicles and pedestrians and subsequently register them in Vissim-Viswalk 9.
Qualitatively, road safety is evaluated by using checklists which clearly reflect insecurity and high vulnerability to pedestrian integrity evident in the 13 items analyzed.
The solution proposal consists of the design of a pedestrian connector of 320 meters, which complies with the required regulations since it has a constant effective width of 1.6 meters and a maximum slope of 5% and 10% on the connector and on the ramp, respectively.
The results show that the proposal allows for a reduction in transfer time by 17.1% and an increase in average speed of 26.1%, and there is also a significant increase in road safety towards pedestrians. / Tesis
|
23 |
Estudo da aderência de arames da armadura de tração em conectores de dutos flexíveis / Study of adhesion of tensile armor wiles in connectors for flexible pipelinesMarcelo Badini Daflon 08 September 2010 (has links)
Este projeto tem o objetivo de apresentar o estudo dos arames da armadura de tração que são empregados no transporte de óleo, gás e umbilicais hidráulicos na indústria petrolífera. Este estudo foi desenvolvido sob a necessidade de melhor ancoragem dos arames da armadura de tração de modo a garantir que, mesmo após a ruptura do arame dentro do conector não haverá o escorregamento do mesmo provocando a queda do duto flexível. Assim sendo, foi estabelecido o estudo de aderência da interface dos arames da armadura de tração dos dutos flexíveis. Com os ensaios concluídos se estudou um novo procedimento para o melhoramento de aderência mecânica dos arames com a resina epóxi. Após os ensaios de aderência e adesão concluídos foi realizado ensaio de tração em cada arame da armadura de tração sob sua montagem no conector de extremidade para verificação de carregamento que chegam nos ganchos dos arames da armadura de tração. Os estudos realizados no conector de extremidade de 2,5 demonstram que os ganchos dos arames da armadura de tração são de grande importância para a integridade estrutural do duto flexível, visto que o cone de resina formado dentro do conector não está em contato com toda a área dos arames das armaduras de tração. / This project aims to present the study of tensile armor wires usually employed in the transport of oil, gas and hydraulic umbilicals in the petroleum industry. This study was developed as a need for better anchoring of the tensile armor wires in order to guarantee that even after the rupture of the wire within the connector it will not slip causing the fall of the flexible riser. Thus was established the adhesion study of the interface of the tensile armor wires of the flexible risers. After the end of the tests a new procedure for improving mechanical adhesion between the wires and the epoxy resin was studied. After the end of the adhesion tests tensile test was performed on each wire of the tensile armor under its mounting on the end fitting for checking the loading that reaches the hook of the armor wires. The trials performed in the
2.5end fitting show that the tensile armor wire hooks are of great importance for the structural integrity of the flexible riser, as there is no contact between the resin cone formed within the end fitting and the tensile armor wires area.
|
24 |
Estudo da aderência de arames da armadura de tração em conectores de dutos flexíveis / Study of adhesion of tensile armor wiles in connectors for flexible pipelinesMarcelo Badini Daflon 08 September 2010 (has links)
Este projeto tem o objetivo de apresentar o estudo dos arames da armadura de tração que são empregados no transporte de óleo, gás e umbilicais hidráulicos na indústria petrolífera. Este estudo foi desenvolvido sob a necessidade de melhor ancoragem dos arames da armadura de tração de modo a garantir que, mesmo após a ruptura do arame dentro do conector não haverá o escorregamento do mesmo provocando a queda do duto flexível. Assim sendo, foi estabelecido o estudo de aderência da interface dos arames da armadura de tração dos dutos flexíveis. Com os ensaios concluídos se estudou um novo procedimento para o melhoramento de aderência mecânica dos arames com a resina epóxi. Após os ensaios de aderência e adesão concluídos foi realizado ensaio de tração em cada arame da armadura de tração sob sua montagem no conector de extremidade para verificação de carregamento que chegam nos ganchos dos arames da armadura de tração. Os estudos realizados no conector de extremidade de 2,5 demonstram que os ganchos dos arames da armadura de tração são de grande importância para a integridade estrutural do duto flexível, visto que o cone de resina formado dentro do conector não está em contato com toda a área dos arames das armaduras de tração. / This project aims to present the study of tensile armor wires usually employed in the transport of oil, gas and hydraulic umbilicals in the petroleum industry. This study was developed as a need for better anchoring of the tensile armor wires in order to guarantee that even after the rupture of the wire within the connector it will not slip causing the fall of the flexible riser. Thus was established the adhesion study of the interface of the tensile armor wires of the flexible risers. After the end of the tests a new procedure for improving mechanical adhesion between the wires and the epoxy resin was studied. After the end of the adhesion tests tensile test was performed on each wire of the tensile armor under its mounting on the end fitting for checking the loading that reaches the hook of the armor wires. The trials performed in the
2.5end fitting show that the tensile armor wire hooks are of great importance for the structural integrity of the flexible riser, as there is no contact between the resin cone formed within the end fitting and the tensile armor wires area.
|
Page generated in 0.0457 seconds