• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 47
  • 11
  • 4
  • Tagged with
  • 62
  • 62
  • 31
  • 15
  • 15
  • 12
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Contribution à la simulation numérique des transferts de chaleur par conduction, rayonnement et convection thermosolutale dans des cavités / Contribution to the numerical simulation of heat transfert by conduction, radiation and thermosolutal convection in cavities

Laaroussi, Najma 30 June 2008 (has links)
L'objectif de cette thèse est de contribuer à la simulation numérique des transferts de chaleur par conduction dans les parois, par rayonnement et par convection thermosolutale dans des cavités fermées ou dans des conduites. Dans la plupart des cas pratiques, les trois modes de transfert de chaleur sont fortement couplés lorsque le fluide en mouvement est un mélange de gaz. Le transfert de chaleur par convection naturelle associé à la condensation surfacique dans une cavité à deux dimensions, remplie d'air humide a été étudié numériquement. Les parois verticales, d'épaisseur finie, sont en contact avec une ambiance extérieure froide. La modélisation faiblement compressible permet à la fois de tenir compte de la diminution de la masse du mélange et de la pression thermodynamique. Egalement, une étude de la convection mixte associée à l'évaporation d'un film liquide ruisselant sur les deux parois d'un canal vertical a été menée. Les effets des forces d'Archimède thermique et solutale sur le développement de l'écoulement ont été montrés. Les résultats ont été obtenus en considérant que les propriétés du mélange sont constantes ou basées sur la règle d'un tiers. Deux mélanges binaires de gaz parfaits air-vapeur et air-hexane ont été considérés en vertu de diverses conditions aux limites / The purpose of this thesis is the contribution to the numerical simulation of heat transfer by conduction, radiation and thermosolutal convection in a closed cavity or in a vertical channel. In most practical cases, the three modes of heat transfer are strongly coupled when the fluid in motion is a mixture of gases. Heat transfer by natural convection and surface condensation in two-dimensional enclosures in contact with a cold external ambient through a wall of finite thickness was studied numerically. Special attention was given on the modeling of the flow of a binary mixture consisting of humid air. Low-Mach number assumption was introduced in order to account for decreases in mixture mass and average pressure within the enclosure between the initial and steady states. Also, a numerical investigation was conducted to study mixed convection in a vertical channel with evaporation of thin liquid films on wetted walls. The effects of the thermal and solutal buoyancy forces on the flow field, heat and mass transfer are illustrated. Results were obtained both for variable and for constant properties using the one-third rule. Air-water vapor and air-hexane vapor mixtures, assumed as ideal gases, are considered under various boundary conditions
32

Etude numérique de la convection naturelle thermique engendrée par des blocs générant de la chaleur dans un canal horizontal et dans une géométrie cubique / Numerical study of thermal natural convection induced by heating blocks in a horizontal channel and in a cubical geometry

Mouhtadi, Driss 03 May 2012 (has links)
L'objectif de ce travail est d'étudier les détails des écoulements et des transferts thermiques induits par convection naturelle au sein d'un canal (simulation bidimensionnelle) et au sein d'une cavité cubique (simulation tridimensionnelle) munis de blocs chauffants. La chaleur dégagée par les blocs résulte d'une génération volumique uniforme de la chaleur, d'une température chaude constante ou d'un flux surfacique uniforme. On utilise l'air (Pr=0.72) comme fluide. Les paramètres de l'étude sont le rapport des conductivités thermiques du bloc solide et du fluide (0.1≤k*≤200), le nombre de Rayleigh (〖10〗^4≤Ra≤〖10〗^7) et la hauteur relative des blocs (1/8≤B≤1/2). La détermination des conditions de validité du modèle à blocs isothermes et du modèle à blocs libérant un flux surfacique uniforme, en fonction du rapport des conductivités thermiques et des autres paramètres du problème, compte parmi les principaux objectifs de ce travail. Les résultats obtenus montrent que l'écoulement et le transfert thermique ainsi que les conditions de validité des modèles mentionnés sont fortement influencés par les paramètres de contrôle et par la multiplicité de solutions trouvée en régime convectif. / The object of this work is to study the details of the flow and heat transfer induced by natural convection in a channel (2D simulation) and in a cubic cavity (3D simulation) containing heating blocks. The heat released by the blocks results from a uniform volumetric heat generation, a constant hot temperature or a uniform surface flux. Air (Pr=0.72) is used as working fluid. The parameters of the study are the thermal conductivities ratio of solid blocks and fluid (0.1≤k*≤200), the Rayleigh number (〖10〗^4≤Ra≤〖10〗^7) and the relative height of the blocks (1/8≤B≤1/2). Among the main objects of this work is the determination of the conditions of validity of the model with isothermal blocks and the model with blocks releasing a uniform surface flux, as functions of the thermal conductivities ratio and the other parameters of the problem. The results obtained show that the flow and heat transfer and the conditions of validity of the models mentioned are strongly affected by the control parameters and the multiplicity of solutions found in the convective regime.
33

Transition vers le chaos en convection naturelle confinée : descriptions lagrangienne et eulérienne / Transition to chaos in confined natural convection : Lagrangian and Eulerian descriptions

Oteski, Ludomir 30 June 2015 (has links)
Cette thèse est une étude numérique d'un écoulement d'air dans une cavité différentiellement chauffée bidimensionnelle en présence de gravité. Pour un rapport hauteur/largeur de deux et des parois horizontales supposées adiabatiques, l'écoulement de base correspond à une recirculation autour de la cavité avec un coeur stratifié et des couches limites verticales. Les équations de Navier-Stokes sont résolues par un code de simulation numérique directe spectrale instationnaire basé sur l’hypothèse de Boussinesq couplé à un algorithme de suivi de particules avec interpolation. Le nombre de Rayleigh basé sur la différence de température est choisi comme paramètre de contrôle de l’écoulement. La transition vers le chaos au sein de cet écoulement est explorée à la fois du point de vue eulérien (développement de l’instationnarité) et lagrangien (mélange chaotique).L'approche lagrangienne considère le mélange de traceurs passifs infinitésimaux non diffusifs. L'étude se base sur l'identification d'objets invariants de la dynamiques : points fixes, orbites périodiques et leurs variétés stable/instable, connections homoclines et hétéroclines, trajectoires toroïdales. Le mélange des traceurs est partiel lorsque l'écoulement subit une première bifurcation de Hopf. La dispersion globale des traceurs résulte d'un compromis entre la présence de tores Kolmogorov-Arnold-Moser qui jouent le rôle de barrières au mélange, et d'enchevêtrements homoclines/hétéroclines responsables du chaos lagrangien. L'étude statistique des temps de retour et du taux d'homogénéisation révèle la présence de zones où la dynamique est non hyperbolique. En augmentant le nombre de Rayleigh, le mélange devient progressivement complet avant que l'écoulement ne devienne quasi-périodique en temps. L'approche eulérienne considère les divers scénarios de transition vers le chaos par l'identification numérique d'attracteurs et des bifurcations associées lorsque le nombre de Rayleigh varie. Deux routes principales se distinguent en fonction des symétries associées aux deux premières bifurcations de Hopf du système, contenant chacune plusieurs branches hystérétiques. Trente trois régimes différents sont identifiés et analysés depuis l'écoulement stationnaire jusqu'à un écoulement chaotique voire hyperchaotique. Parmi ceux-ci, des branches de tores à deux et trois fréquences incommensurables, ainsi que des régimes intermittents sont examinés. Des diagrammes de bifurcations qualitatifs et quantitatifs sont proposés pour résumer l'ensemble des dynamiques observées. / This thesis is about the numerical study of an air flow inside a two dimensionally heated cavity. The aspect ratio height/width is set to two. Boundary conditions on horizontal walls are taken as adiabatic. In this case, the base flow consists of a recirculation around the stratified core of the cavity and of boundary layers along the vertical walls. The Navier-Stokes equations are solved using a spectral direct numerical simulation code under the Boussinesq assumption coupled with a particle tracking scheme based on interpolation. The Rayleigh number, based on the temperature difference is chosen as the control parameter of the system. The transition to chaos in this flow is considered both from the Eulerian and Lagrangian point of view.The Lagrangian point of view considers the mixing of point-wise non-diffusive passive tracers. The study is based on the identification of invariant objects: fixed points, periodic orbits and their stable/unstable manifolds,homoclinic and heteroclinic connections, toroidal trajectories.The mixing of tracers is partial when the flow undergoes the first Hopf bifurcation. The complete mixing of tracers results from a compromise between Kolmogorov-Arnold-Moser's tori, which act as barriers to mixing, and homoclinic/heteroclinic tangles which are responsible for the mixing.The statistical study of return times and the homogenisation rate shows regionswhere the dynamics is non-hyperbolic. When the Rayleigh number is increased, mixing is increasingly complete before the flow becomes quasi-periodic in time.The Eulerian description considers the transition to chaos via the numerical identification of attractors and their associated bifurcations when the Rayleigh number is varied. Two main routes are found depending on the symmetries associated with the first two Hopf bifurcations of the system. A total of thirty three different regimes are identified from steady to hyperchaotic, among which two- and three-frequency tori as well as intermittent dynamics. Both quantitative and qualitative bifurcation diagrams are suggested for the system.
34

Étude numérique et expérimentale du refroidissement des convertisseurs auxiliaires de puissance dans les trains par convection naturelle, film liquide et caloduc / Numerical and experimental study of cooling of the auxiliary converters in trains by natural convection, liquid film and heat pipe

Zouitene, Saâd 06 June 2014 (has links)
Cette thèse porte sur l’étude et l’optimisation du refroidissement des convertisseurs électriques de puissance (CVS) utilisés dans les trains. Ces composants de grandes dimensions sont lourds, bruyants, et représentent un gouffre énergétique à cause de leur système de refroidissement composé de ventilateur. Nous analysons d’autres types de refroidissements économiques et efficaces. Nous étudions numériquement sous Comsol Multiphysics le refroidissement des CVS par convection naturelle en utilisant l’effet cheminée et par film liquide en exploitant le changement de phase pour évacuer le maximum de chaleur. Les résultats numériques sont validés avec les résultats issus de la littérature et ceux obtenus expérimentalement grâce à un dispositif réalisé pour cette étude. Les résultats obtenus ont permis de constater que la convection naturelle n’est pas suffisante pour évacuer la chaleur et que le refroidissement par film liquide représente une solution très efficace. Nous avons aussi étudié expérimentalement l’efficacité du refroidissement par caloducs. L’influence de la répartition de la chaleur a aussi été analysée pour optimiser l’emplacement des composants électroniques dans le CVS. Une comparaison générale de tous les résultats a permis de proposer le système le plus optimiser en fonction des paramètres choisis. / This thesis is about a study and optimization of the cooling electric power converters (CVS) used in trains. These components are heavy, noisy, and are not energetically efficient. We analyze other types of economic and efficient cooling. We used Comsol Multiphysics to study numerically CVS cooling by natural convection using the chimney effect and liquid film by exploiting the phase change to evacuate heat. The numerical results are validated with the results from literature and those obtained experimentally. The results have shown that natural convection is not sufficient to evacuate the heat and the cooling by liquid film represents an interesting solution. We also studied experimentally the effect of the heat pipe cooling. The influence of the heat distribution was also analyzed to optimize the location of the electronic components in the CVS. A general comparison of all results was proposed to optimize the cooling system.
35

Convection turbulente dans une cellule de Rayleigh-Bénard cryogénique : de nouveaux éléments en faveur du Régime Ultime de Kraichnan

Gauthier, Frédéric 08 December 2008 (has links) (PDF)
Cette thèse est consacrée à l'étude de la convection turbulente pour des nombres de Rayleigh (Ra) pouvant atteindre 10^14 grâce à l'utilisation de l'hélium cryogénique. Nous nous intéressons plus particulièrement au régime de convection apparaissant pour Ra≈10^12. Ce régime a été observé et interprété à Grenoble il y a une dizaine d'années, comme la transition vers le Régime Ultime de la convection prédit par R. Kraichnan en 1962. Deux signatures de ce régime avaient alors été observées : une augmentation du nombre de Nusselt (Nu) ainsi qu'un changement qualitatif sur les fluctuations de température dans le cœur de la cellule, cette dernière signature ayant été contestée en invoquant un effet de taille de capteurs. Dans un premier temps, nous confirmons la transition déjà observée sur les mesures locales de température, à partir de mesures réalisées avec un thermomètre dix fois plus petit. Ce résultat est complété par une étude de l'influence de la taille des thermomètres sur les mesures. Des thermomètres dont la taille varie de 17 microns à 2 mm ont été fabriqués dans ce but. Ensuite, nous observons indirectement une instabilité de la couche limite thermique, en accord avec les prédictions sur le Régime Ultime. Cette observation est réalisée à partir de mesures des fluctuations de température de la plaque inférieure de la cellule. Cette transition et celle sur Nu interviennent pour le même Ra. Enfin, nous écartons l'hypothèse selon laquelle la transition observée sur le transfert thermique serait associée à une transition de l'écoulement à grande échelle dans la cellule, grâce à une caractérisation de cet écoulement avant et après la transition.
36

Contribution à l'analyse et à la modélisation des écoulements turbulents en régime de convection mixte - Application à l'entreposage des déchets radioactifs

Lecocq, Yannick 17 December 2008 (has links) (PDF)
Dans le cadre de la problématique du refroidissement des déchets radioactifs, ce travail a pour objectifs l'étude de l'écoulement autour d'un cylindre chauffant monté en paroi soumis à un écoulement transverse selon l'approche URANS. Les limitations bien connues de la modélisation au premier ordre conduisent à considérer une approche au deuxième ordre. C'est dans ce sens qu'un modèle d'échange thermique est développé puis validé sur des cas académiques.<br>Dans un premier temps, lorsque le régime de convection mixte est dominant, ces calculs, réalisés par le modèle bas-Reynolds k-w SST, et complétés par un calcul isotherme, mettent en évidence de nombreuses structures tourbillonnaires recensées par la bibliographie. Un calcul avec le modèle haut-Reynolds Rij-epsilon SSG est aussi effectué. Avec le modèle k-w SST, l'échange thermique est convenablement reproduit par rapport à l'expérience VALIDA, conduite par le CEA, alors qu'avec le modèle Rij-epsilon SSG celui-ci est fortement sous-estimé, certainement en raison de l'utilisation de lois de paroi. <br>Dans un second temps, lorsque la convection naturelle est prépondérante, la topologie des écoulements est alors complètement différente et le transfert thermique est bien moins fidèle à l'expérience VALIDA.<br>Le modèle à pondération elliptique EBRSM, issu de l'approche de Durbin, consiste en la prise en compte des effets de paroi, et en particulier le blocage à la paroi. D'après ce formalisme, un modèle algébrique des flux thermiques avec pondération elliptique est développé, l'EBAFM. Avec ce modèle, des tests a priori dans les trois régimes de convection puis les simulations sur les mêmes cas montrent une nette amélioration dans la prédiction des différents écoulements faisant place à une perspective intéressante d'un modèle intermédiaire entre une formulation SGDH et des équations de transport.
37

Contribution à l'analyse et à la modélisation des écoulements turbulents en régime de convection mixte - Application à l'entreposage des déchets radioactifs

Lecocq, Yannick 17 December 2008 (has links) (PDF)
Dans le cadre de la problématique du refroidissement des déchets radioactifs, ce travail a pour objectifs l'étude de l'écoulement autour d'un cylindre chauffant monté en paroi soumis à un écoulement transverse selon l'approche URANS. Les limitations bien connues de la modélisation au premier ordre conduisent à considérer une approche au deuxième ordre. C'est dans ce sens qu'un modèle d'échange thermique est développé puis validé sur des cas académiques. <br /><br />Dans un premier temps, lorsque le régime de convection mixte est dominant, ces calculs, réalisés par le modèle bas-Reynolds ßt, et complétés par un calcul isotherme, mettent en évidence de nombreuses structures tourbillonnaires recensées par la bibliographie. Un calcul avec le modèle haut-Reynolds Rij-epsilon SSG est aussi effectué. Avec le modèle k-w SST, l'échange thermique est convenablement reproduit par rapport à l'expérience VALIDA, conduite par le CEA, alors qu'avec le modèle Rij-epsilon SSG celui-ci est fortement sous-estimé, certainement en raison de l'utilisation de lois de paroi. <br /><br />Dans un second temps, lorsque la convection naturelle est prépondérante, la topologie des écoulements est alors complètement différente et le transfert thermique est bien moins fidèle à l'expérience VALIDA.<br /><br />Le modèle à pondération elliptique EB-RSM, issu de l'approche de Durbin, consiste en la prise en compte des effets de paroi, et en particulier le blocage à la paroi. D'après ce formalisme, un modèle algébrique des flux thermiques avec pondération elliptique est développé, l'EB-AFM. Avec ce modèle, des tests a priori dans les trois régimes de convection puis les simulations sur les mêmes cas montrent une nette amélioration dans la prédiction des différents écoulements faisant place à une perspective intéressante d'un modèle intermédiaire entre une formulation SGDH et des équations de transport.
38

Instabilités de Rayleigh-Bénard-Marangoni, induites par évaporation, en régime transitoire. Applicatons aux solutions polymères

Trouette, Benoît 09 December 2010 (has links) (PDF)
Dans ce travail nous étudions numériquement le déclenchement d'instabilités thermo-solutales dans le cas du séchage d'une solution polymère. L'évaporation du solvant entraine une baisse de la température et de la concentration du solvant en surface. Ceci peut générer des instabilités thermo-convectives et solutales, induites par les variations de la masse volumique (poussée d'Archimède) et/ou de la tension super ficielle (eff et Marangoni). L'épaisseur du milieu ainsi que les gradients de température et de concentration évoluent au cours du séchage et il s'agit donc d'un problème transitoire. Deux modèles simplifiés sont mis en place, tenant respectivement compte des e ffets thermique et solutal. L'étude porte principalement sur trois points : la détermination du rôle respectif de chaque phénomène, le caractère transitoire du problème, et enfi n l'influence de l'évolution de la viscosité de la solution avec la concentration au cours du séchage sur les seuils de transition entre les régimes conductif et convectif.
39

Etude expérimentale de la convection naturelle en canal vertical à flux de chaleur imposé : application au rafraîchissement passif de composants actifs de l'enveloppe des bâtiments

Daverat, Christophe 15 October 2012 (has links) (PDF)
La réduction de la consommation des bâtiments passe par : l'économie d'énergie, l'efficacité énergétique et l'utilisation des énergies renouvelables. Sur ce dernier point, l'intégration à grande échelle de composants photovoltaïques (PV) est une solution. Le rendement et la durée de vie des cellules PV en silicium cristalin diminuant avec l'augmentation de leur température de fonctionnement, il est essentiel de mettre au point des configurations d'intégration limitant leur échauffement. L'intégration en configuration de double-peau - la surface PV est séparée du bâtiment par une lame d'air - est une solution prometteuse. Sous l'effet de la chaleur, un écoulement de convection naturelle se met en place entre les deux parois, refroidissant ainsi les panneaux PV. Cet écoulement peut également servir de moteur pour la ventilation en été, et de préchauffage de l'air en hiver. Cette étude, expérimentale, fait partie d'un projet visant à comprendre le fonctionnement des double-peaux PV en analysant séparément les différents phénomènes physiques avant de prendre en compte l'ensemble des couplages. Elle porte plus particulièrement sur la convection naturelle au sein des double-façades verticales. Ici, la double-peau est modélisée par un canal vertical dont les deux parois principales sont chauffées sous des conditions de flux imposé. Un banc d'essais a été développé pour étudier la convection naturelle dans un canal vertical en eau. L'eau a été choisie pour se placer dans le cas d'un écoulement de convection pure (pas de rayonnement entre les parois). C'est un canal vertical de 65 cm de haut avec un écartement réglable placé dans une cuve de 1,5 m de haut contenant 160 L d'eau. Les parois sont chauffées à l'aide de 24 chaufferettes indépendantes délivrant un flux de chaleur uniforme, ce qui permet d'appliquer différentes configurations de chauffage. Des mesures de flux et de température sont réalisées au niveau des parois, et un système couplant de la velocimétrie laser Doppler deux composantes à un micro-thermocouple (25 μm) a été développé pour avoir accès aux vitesses verticale et horizontale et à la température dans le canal. Ce banc et son instrumentation sont décrits et les incertitudes de mesure associées ont été caractérisées. La configuration de chauffage uniforme symétrique a été étudiée ici pour différentes puissances injectées. Les profils de vitesse et de température moyennes mettent en évidence la présence d'un changement de régime d'écoulement dans le canal pour un nombre de Rayleigh indéntifié. L'étude approfondie des profils des fluctuations de vitesse et de température a permis de mettre au point une modélisation comportementale de ce changement de régime. De plus, une première approche est développée pour évaluer la pression dans le canal à partir de l'analyse et de l'estimation des différents termes de l'équation de conservation de la quantité de mouvement.
40

Etude d'une paroi ventilée multifonctionnelle adaptée à la rénovation énergétique des bâtiments par l'intérieur

Pinard, Sébastien 13 December 2012 (has links) (PDF)
Le secteur tertiaire représente une source potentielle d'économie incontournable pour parvenir à réduire la dépendance énergétique de la France. Le taux de renouvellement du parc immobilier Français étant relativement faible, un effort doit être porté sur l'existant. Dans ces travaux, nous étudions un procédé innovant de rénovation par l'intérieur, dont l'élément principal est une paroi ventilée multifonctionnelle, assurant l'isolation, l'émission de chaleur basse température ainsi que la finition des surfaces murales. Les premiers travaux sur cette paroi ventilée furent menés sur un prototype dimensionné _a l'aide d'un modèle numérique simplifié. Deux séries d'expériences menées dans une cellule climatique nous ont permis de quantifier les flux de chaleur à travers le système. Le bon fonctionnement de la paroi ventilée repose sur les mécanismes de convection naturelle dans un canal vertical. Les résultats issus du prototype ont montré la présence de phénomènes complexes intervenant au sein de l'écoulement. Nous avons donc choisi d'étudier plus en détails les phénomènes thermoconvectifs dans un système du type source chaude/cheminée avant de poursuivre l'étude sur le système global. Une étude théorique et une expérience ont été menées sur un cas académique du problème. A l'issue des résultats expérimentaux, nous avons observé plusieurs régimes d'écoulements, dépendants du rapport de forme du canal et du nombre de Richardson en sortie. Enfin, nous proposons un modèle analytique de la paroi ventilée comprenant l'ensemble des variables géométriques influentes. Ce modèle a été implémenté dans l'environnement de simulation Trnsys, dans la perspective d'effectuer des simulations annuelles à l'échelle du bâtiment.

Page generated in 0.126 seconds