• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1392
  • 17
  • 16
  • 15
  • 15
  • 15
  • 7
  • 7
  • 7
  • 4
  • 4
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 1431
  • 690
  • 469
  • 306
  • 241
  • 205
  • 197
  • 185
  • 166
  • 158
  • 122
  • 121
  • 116
  • 108
  • 105
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Efeito da porosidade e dos tratamentos termoquímicos de nitretação e nitrocementação na resistência à corrosão de ferro puro sinterizado e tratado via plasma

Antunes, Flávio de Oliveira January 2017 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Ciência e Engenharia de Materiais, Florianópolis, 2017. / Made available in DSpace on 2017-10-31T03:19:03Z (GMT). No. of bitstreams: 1 348701.pdf: 1936544 bytes, checksum: 0db6dcf8e065c7748c105a61bbf71cd0 (MD5) Previous issue date: 2017 / A presença de poros em componentes produzidos via Metalurgia do Pó (MP) dificulta a aplicação em situações onde se requer resistência à corrosão. As técnicas de nitretação e nitrocementação vêm sendo utilizadas com o intuito de atribuir aos componentes produzidos via MP melhoras nas propriedades tribológicas e resistência à corrosão. No entanto, sabe-se que a eficiência destes tratamentos superficiais nem sempre apresenta resultados positivos, dependendo das características da porosidade presente na superfície. Muitos estudos têm sido realizados visando melhorar a qualidade das camadas formadas, selecionando parâmetros que resultem em melhoras na resistência à corrosão. Neste trabalho, amostras com diferentes graus de porosidade foram nitretadas e nitrocementadas por plasma com o intuito de avaliar as melhores respostas no desempenho à corrosão. Para obter diferentes graus de porosidade foram processadas amostras com 3 faixas de granulometria de pós. As amostras foram sinterizadas por plasma em atmosfera de (95%Ar-5%H2), a 1150 oC por 1 hora. A nitretação foi também realizada via plasma em atmosfera de (90%N2-10%H2), 570 oC e por 2 horas. A nitrocementação foi realizada em atmosfera de (90%N2?7,5%H2-2,5%CH4), a 570 oC e por 2 horas. Os ensaios eletroquímicos foram realizados com solução de 0,5 M KNO3. Como resultado, observou-se que o tamanho dos poros e a morfologia da camada produzida no tratamento termoquímico exerce grande influência na resistência a corrosão dos aços sinterizados. Os tratamentos de nitretação e nitrocementação atribuíram ao componente sinterizado uma maior resistência a corrosão, que está ligado à espessura e continuidade da camada de compostos. As amostras sinterizadas com menor granulometria e nitrocementadas apresentaram melhores resultados de resistência à corrosão.<br> / Abstract : The presence of pores in the components produced by Powder Metallurgy (MP) makes it difficult to apply them in situations where corrosion resistance is required. The nitriding and nitrocarburising techniques have been used with the aim of assigning MP pieces to the tribological properties and resistance to corrosion. However, it is known that the efficiency of these surface treatments does not always present positive results, depending on the characteristics of the pores present on the surface. Many studies have been carried out aiming at improving the quality of the formed layers, selecting parameters that result in improvements in the resistance to corrosion. In this work, samples with different degrees of porosity were nitrided and nitrocarburised by plasma in order to evaluate the best responses in the corrosion performance. Samples with 3 bands of powder granulometry were processed to obtain different degrees of porosity. The samples were sintered by plasma in atmosphere of (95%Ar-5%H2) at 1150 oC for 1 hour. Nitriding was also performed via plasma in an atmosphere of (90%N2-10%H2), 570 oC and for 2 hours. Nitrocarburization was carried out in an atmosphere of (90%N - 7.5%H2 - 2.5%CH4) at 570 ° C for 2 hours. The electrochemical tests were performed with 0.5M KNO3 solution. As a result, it was observed that the pores size and the morphology of the layer produced in the thermochemical treatment exerts a great influence on the corrosion resistance of the sintered steels. The treatments of nitriding and nitrocarburising gave the sintered component a higher resistance to corrosion, which is related to the thickness and continuity of the layer of compounds. The sintered samples with lower particle size and nitrocarburized showed better corrosion resistance results.
322

Estudo da adição de polietilenoglicol em ácido hexafluorzircônico na formação da camada nanocerâmica

Santos, Fábio Souza dos January 2016 (has links)
O estudo de pré-tratamentos, para aumentar a resistência aos efeitos da corrosão e melhorar a performance da pintura para prolongar a vida útil dos materiais, é muito importante para o setor industrial. Os prejuízos referentes à corrosão alcançam valores inimagináveis por todos nós. Entender o funcionamento desta área é vital. O pré-tratamento mais usado atualmente ainda é a fosfatização, que desempenha bem o seu papel de revestimento protetivo e base para a pintura, porém deixa resíduos perigosos no ambiente, a chamada lama, ou lodo, de fosfatização. Em função disso novos métodos são estudados, e alguns já estão sendo usados na indústria com cada vez mais frequência. Um dos métodos é através do uso de camadas de conversão a base de ácidos hexafluorzircônico ou hexafluortitânico. Por já estarem estabelecidos no mercado, é necessário aprimorar seu uso, buscando melhorias no desempenho destes produtos. A camada formada consiste em uma fina camada de óxido de zircônio em escala nanométríca, sendo por isso conhecida como camada ou revestimento nanocerâmico. No presente trabalho foi feito uma avaliação da camada protetora formada em solução de ácido hexafluorzircônico, sem e com adição de determinadas quantidades de um polímero, o polietilenoglicol, e avaliou-se a qualidade dos revestimentos obtidos. Para avaliar a qualidade de cada camada protetora foram realizados diversos ensaios, simulando ambientes salinos e urbanos, ensaios eletroquímicos e de aderência. Foi possível verificar que a adição do polímero na solução de pré-tratamento é capaz de proporcionar benefícios à qualidade de barreira protetora nanocerâmica. O comportamento da barreira em ensaios eletroquímicos e ensaios acelerados simulando ambientes corrosivos mostrou que em certas concentrações e valores de pH o desempenho é promissor e justifica seu uso. / The pre-treatments studies to increase resistence to the corrosion effects and improve painting performance for prolong the life of the materials is very important for industry. Losses related to the corrosion may appear unimpressive, but reach unimaginable values for all of us. To understand the functioning of this area is vital. The most widely used pre-treatment is currently still phosphating. He plays well its role of protective coating and base for painting, but leaves dangerous waste on the environment. As a result, new methods are studied, and some are already being used in the industry with increasingly frequency. One method is through the use of conversion layers by the use of zirconium or titanium acids. Because they are already established on market, it is necessary to improve its use, seeking improvements in the performance of these products. The formed layer consists of a thin zirconium oxide layer on a nanometric scale, so it is known as a nanoceramic layer or nanoceramic coating. In the present work was done an evaluation of the protective layer formed by an acid, the hexafluorzirconic acid, with and without addition of certain amounts of a polymer, polyethylene glycol, and evaluate the quality of the coatings obtained. Therefore many tests were carried out, simulating saline and urban environments, electrochemical tests and grip tests. It was verified that the addition of polymer in the pre-treatment solution is capable of providing benefits for the quality of nanoceramic protective barrier. The barrier performance in electochemical tests and accelerated tests simulating corrosive environments showed that at certain concentrations and pH values the performance is promising and justifies its use.
323

Simulação e operação de célula de combustível com geração in situ de hidrogênio através da corrosão alcalina do alumínio

Porciúncula, Cleiton Bittencourt da January 2013 (has links)
Células de combustível são dispositivos onde ocorre a oxidação eletroquímica de um combustível, apresentando maior eficiência, segurança e escalabilidade do que a maioria dos motores de combustão interna. A geração de hidrogênio a partir do alumínio possui a vantagem de utilizar-se metal que pode ser completamente recuperado, reciclado e reprocessado. Além disso, refugos feitos à base de alumínio tais como: latas de bebidas; peças de dispositivos eletrônicos; brinquedos; dentre outros, podem ser utilizados para geração de hidrogênio, o que incentivaria a reciclagem de materiais. A reação ocorre com a água na presença de álcalis fortes, tais como NaOH e KOH, que atuam como catalisadores, não sendo assim consumidos no processo. O objetivo principal deste trabalho é a construção de uma célula de combustível de baixa temperatura, denominada na literatura de PEMFC (Proton Exchange Membrane Fuel Cell, Célula de Combustível com Membrana de Troca de Prótons) acoplada à geração local de hidrogênio por meio da corrosão alcalina do alumínio. Foram realizados experimentos variando-se os seguintes itens: concentração dos álcalis (de 1 a 3 mol.L-1), temperatura (295 a 345 K) e forma do metal (folhas de alumínio com 0,02 mm de espessura, lâminas com 0,5 mm e com 1 mm de espessura). Nesta primeira etapa, verificou-se que a concentração e temperatura influenciam fortemente a reação. Os tempos de reação variaram desde valores próximos de 2 minutos (reação de folhas de alumínio em presença de NaOH a 3 mol.L-1 na temperatura de 325 K) até tempos da ordem de 700 minutos (em experimentos utilizando lâminas de 1 mm a 315 K em presença de KOH 1 mol.L-1). A análise de difração de raios-x juntamente com a microscopia eletrônica de varredura (MEV) confirmou a presença de hidróxido de alumínio na forma de um precipitado de gibsita sobre uma amostra metálica após reação com NaOH, possibilitando a visualização da estrutura cristalina deste precipitado. Após construção e operação do reator alumínio-água acoplado à célula de combustível, obteve-se valores de diferença de potencial máximos da ordem de 150 mV e densidade de corrente máxima próxima a 5.10-3 mA.cm-2. Estes valores encontram-se muito abaixo dos valores esperados para uma célula de combustível de hidrogênio comum (ao redor de 700 mV e 200-400 mA.cm-2, respectivamente). Um modelo transiente simplificado do sistema, baseado em balanços de massa, energia e carga elétrica, foi utilizado para a compreensão do funcionamento do dispositivo. Assim, verificou-se que uma das possíveis causas da operação estar abaixo da eficiência esperada foi devido à baixa relação estequiométrica entre oxigênio alimentado por difusão do ar e vazão de hidrogênio obtido a partir da reação entre alumínio e água. / Fuel Cells are devices where electrochemical oxidation of a fuel occurs, showing more efficiency, safety and scalability than most of the internal combustion engines. The production of hydrogen from aluminum has the advantage to utilize a metal that might be completely recovered, recycled and re-processed. Moreover, wastes made with aluminum such drink cans, pieces of electronic devices, toys, among others, are possible to be utilized to generate hydrogen, which would encourage the material recycling. The reaction occurs with the water in the presence of strong alkali like NaOH and KOH, which act as catalysts, so not being consumed in the process. The main objective of this work is the construction of a low temperature fuel cell, named in the literature as PEMFC (Proton Exchange Membrane Fuel Cell) coupled to local hydrogen generation by means of the aluminum alkaline corrosion. Experiments were conducted by varying the following items: alkali concentration (1-3 mol.L-1), temperature (295-345 K) and metal shape (0.02 mm thick aluminum foils, 0.5 mm and 1 mm thick aluminum plates). In this first step, it has been verified that the concentration and temperature strongly influence the reaction. The reaction times varied from values close to 2 minutes (aluminum foils in the presence of NaOH 3 mol.L-1 at 325 K) up to times about 700 minutes (experiments utilizing 1 mm thick plates at 315 K in the presence of KOH 1 mol.L-1). Analysis of Scanning Electron Microscopy (SEM) together with X-ray Difraction (XRD) has confirmed the presence of aluminum oxide as gibbsite precipitate on the metallic sample after reaction with NaOH, which enabled the visualization of its crystalline structure. After construction and operation of the aluminum-water reactor coupled with the fuel cell, maximum values of electrical potential about 150 mV and current density about 5.10-3 mA.cm-2 were obtained. These values are very low in comparison with the values expected for common hydrogen fuel cells (about 700 mV and 200–400 mA.cm-2, respectively). A simplified transient model was developed, based on mass, energy and electric charge balances, in order to understand the operation of the device. It has been verified that one of the possible issues of low efficiency of the operation is due to low stoichiometric ratio between oxygen fed by air diffusion and hydrogen mass flow obtained from aluminum–water reaction.
324

Avaliação da resistência à corrosão-fadiga do aço API 5CT P1 10 em meio aquoso salino contendo H2S

Krauspenhar, Thiago Luz January 2012 (has links)
Este trabalho tem por objetivo avaliar a resistência à corrosão-fadiga do aço API 5CT P110 em meio aquoso salino contendo CO2 e H2S e comparar com os resultados de fadiga ao ar, bem como avaliar a sua adequação ao uso nessas condições conforme normas vigentes e revisão da literatura. Esse aço é classificado como sendo do tipo ARBL (alta resistência, baixa liga) e é especificado principalmente para uso em colunas de revestimento (casing) e colunas de produção (tubing) para poços de petróleo e gás. As colunas de revestimento e de produção para poços de petróleo offshore necessitam operar sob altas pressões em profundidades cada vez mais elevadas, necessitando apresentar alta resistência e boa tenacidade para suportar as solicitações de tração, pressão interna, colapso e fadiga ao longo da sua vida útil. Adicionalmente, essas tubulações precisam resistir também à corrosão causada pela fase aquosa produzida juntamente com o petróleo e gás extraídos, os quais podem conter gases agressivos dissolvidos, tais como o CO2 e o H2S, além de espécies agressivas como os íons cloretos. As condições do meio agressivo do ensaio de corrosão-fadiga foram escolhidas para simular condições possíveis de serem encontradas em poços de petróleo e gás offshore. Para atingir estes objetivos foram realizados ensaios de fadiga ao ar e ensaios de corrosão-fadiga utilizando um controle de carga sob flexão a três pontos. Para os ensaios de fadiga ao ar, foi utilizada uma máquina servo-hidráulica, razão de carregamento de 0,1, frequência de 20 Hz e run out de 10 milhões de ciclos. Já os ensaios de corrosão-fadiga foram realizados em um equipamento especial para ensaios de corrosão-fadiga, contendo todo um sistema específico para automação e controle dos ensaios. Para corrosão-fadiga foi utilizada a razão de carregamento de 0,1, frequência de 0,5 Hz e run out de 1 milhão de ciclos. Para os ensaios de corrosão-fadiga foi utilizada uma solução aquosa salina contendo 115.000 ppm de cloretos, previamente desaerada. Dentro da cuba, durante o ensaio, a solução foi saturada com uma mistura gasosa composta de CO2 contendo 10.000 ppm de H2S. A cuba de ensaio foi pressurizada com a mistura gasosa até atingir a pressão atmosférica e a temperatura de ensaio de 50°C. Foram ensaiados oito corpos de prova em fadiga ao ar e seis em corrosão-fadiga. As amostras foram usinadas a partir de um segmento de tubo e foram previamente lixadas para retirar os riscos de usinagem e evitar concentradores de tensão na superfície. Os resultados foram plotados em um mesmo gráfico de amplitude de tensão (Δσ) no eixo das ordenadas e logaritmo do número de ciclos até a fratura no eixo das abscissas para a construção das curvas de Wöhler. O comportamento em corrosão-fadiga apresentou uma redução significativa na vida em fadiga em relação à fadiga ao ar, demonstrando a forte agressividade do meio causada principalmente pela presença do H2S. Desse modo, este trabalho apresenta resultados indicando uma grande queda no desempenho em fadiga do aço API 5CT P110 frente a meios contendo H2S na produção de óleo e gás, principalmente associado ao mecanismo de trincamento sob tensão em presença de sulfeto (sulfide stress cracking). / Casing and tubing for offshore wells in the petroleum and natural gas industries are subjected to high pressures under increasing well depths, so they increasingly require high strength and good toughness in order to support the tensile stresses, internal pressure, collapse and fatigue during the predicted lifetime. Additionally, these casing and tubing need to support the corrosion caused by the aqueous phase produced together with the petroleum and gas extracted that may also contain aggressive dissolved gases such as CO2 and H2S and even aggressive species such as chloride ions. Thus, this work aims to determine and compare the fatigue and corrosion fatigue behavior of the API 5CT P110 steel in the presence of water with high chloride content containing CO2 and 10.000 ppm of H2S and evaluate the fitness for purpose in this environment based on current standards and literature review. This steel is classified as a high strength low alloy steel (HSLA) and is specified for use as casing and tubing for wells in the petroleum and natural gas industries. Fatigue and corrosion fatigue tests were performed in air and in aggressive environment. The experiments were conducted using three point bend test and a frequency of 20 Hz in air and 0,5 Hz in aggressive environment. All final data are presented on a Wöhler curve. The corrosion fatigue behavior showed a significant reduction in fatigue life compared to fatigue in air, demonstrating the strong aggressiveness of the environment mainly caused by the H2S presence. Thereby, this work presents results indicating a large decrease in fatigue performance of API 5CT P110 steel facing H2S containing environments in oil and gas production, mainly associated with the mechanism of sulfide stress cracking.
325

Comportamento eletroquímico e susceptibilidade a corrosão sob tensão do aço ABNT 1080 utilizado em armaduras de concreto protendido

Schroeder, Roberto Moreira January 1999 (has links)
Estudou-se o comportamento à corrosão e à corrosão-sob-tensão do aço eutetóide empregado em concreto protendido utilizando diversas técnicas experimentais, como curvas de polarização, ensaios de tração com velocidades de deformação média, e ensaios fractomecânicos. Utilizou-se como meio, simulando, o que é usualmente encontrado nos poros do concreto, o Ca(OH)2 saturado, contaminado com diversos teores de cloreto e sulfatos. Com fins comparativos, utilizou-se a solução de tiocianato de amônia padronizada para avaliar a susceptibilidade de aços à fragilização por hidrogênio de aços em concreto. A influência de parâmetros como potencial, temperatura (entre 0° e 90 ) e temperatura de revenido, entre outros são avaliados. O mecanismo de ruptura é avaliado tendo o hidrogênio uma participação importante neste processo. / The corrosion and stress corrosion behaviour of AISI 1080 steel employed in concrete prestressed tendon was studied with different experimental techniques. A simulated solution usually found in concrete with and without contaminants as chlorides and sulphates was used. For comparison purpose the standard ammonium tiocianate solution was employed in some Polarization tests, constant extention rate tests with intermediate velocities and fractomechanic tests. The influence of parameters like potentiall temperature (between 0° and 90°), temper temperature of the steell was studied. The results showed that the fracture mechanism is associated with hydrogen action in the stress corrosion cracking process.
326

Crescimento e caracterização microestrutural e microquímica de filmes de nitreto de cromo depositados por magnetron sputtering desbalanceado

Senna, Marcos Jose Hoffmann de January 1996 (has links)
Filmes de nitreto de cromo foram depositados por magnetron sputtering desbalanceado, em atmosferas contendo N2 puro. Foram utilizados como substratos wafers de SiO2 amorfo e de MgO (001). Os filmes sobre Si02 foram depositados a 250 °C, e os filmes sobre MgO a 500 °C. A energia da partícula bombardeando a superficie durante a deposição e o fluxo dessas partículas para o substrato foram variados independentemente um do outro, permitindo que sua influência sobre a microestrutura resultante fosse determinada. A caracterização do plasma foi feita com o uso de sondas eletrostáticas. Para a caracterização dos filmes foram utilizadas as técnicas de microscopia eletrônica de transmissão de vista de topo e de seção transversal, microscopia eletrônica de varredura, difração de raios-x convencional e de alta resolução, difração de elétrons, espectrometria de Rutherford back-scattering e espectroscopia eletrônica Auger. Os filmes depositados sobre SO2 mostraram ser policristalinos monofãsicos com estrutura cristalina correspondente a do CrN, e apresentaram forte orientação preferencial na direção (111). Um aumento no bombardeamento iônico sobre o substrato causou uma sensível densificação do filme, com diminuição da porosidade inter- e intra-colunar. Os filmes obtidos sobre MgO (001) eram epitaxiais, com estrutura do CrN. O parâmetro de rede na direção do crescimento desses filmes aumentou em relação aos valores bulk, indicando a presença de tensão residual compressiva. Os filmes depositados com o uso de alta taxa de fluxo iônico para fluxo metálico J/JMc eram completamente densos, enquanto que aqueles nos quais foi usado baixo fluxo ocorreu a formação de vazios de dimensões nanoscópicas. A resistividade elétrica dos filmes epitaxiais foi influenciada por degraus existentes na superficie dos wafers, formados durante a etapa de clivagem. A nanodureza dos filmes epitaxiais apresentou um valor de cerca de 1300 kgfmm-2 . / Chromium nitride films, tipically 1 μm thick, were grown on amorphous SiO2 at 250 °C and on MgO (001) at 500 °C by ultra-high-vacuum reactive unbalancing magnetron sputter deposition in pure N2 discharges. The effects o f incident ion/metal flux ratio and ion energy on the film microstructure, texture, composition, morphology and stress state were examined using x-ray diffraction, transmission electron diffraction, transmission electron microscopy, scanning electron microscopy, Rutherford back-scattering spectrometry and Auger electron spectroscopy. Films grown on SiO2 presented a single-phase polycrystalline strongly (111)-oriented Bl NaCl-structure corresponding to CrN. In the absence of ion bombardment films deposited on Si02 were underdense and exhibited high inter- and intra-grain porosity. A high-flux low-energy ion irradiation during deposition leads to film densification with a sharp decrease in porosity. Films deposited on MgO (001) with low and high flux were epitaxiaL demonstrating that epitaxiality was mainly determiued by the temperature. Films deposited using high flux, however, showed a completely dense structure while those ones obtained using low flux presented some nanoscopic voids. Electrical resistivity of the epitaxial films was influenced by cleavage-induced steps in the substrate. Hardness of the epitaxial films, determiued with a pyramidal nanoindenter, was about 1300 kgfmm-2.
327

Tratamento químico e eletroquímico de superfícies de silício em meios contendo fluoretos

Gomes, Carmem Rosane Isse January 1996 (has links)
A preparação de superfícies de silício na indústria microeletrônica é feita por processos que, geralmente, envolvem uma etapa por via úmida com soluções alcalinas ou contendo fluoretos. Tais sistemas produzem acabamentos diferenciados: a partir da dissolução em presença de bases fortes, ocorre a dissolução por meio de reações de natureza anisotrópica e com o uso de soluções contendo fluoretos, a maior aplicação tecnológica é devida ao ataque químico isotrópico. O presente trabalho investigou o comportamento de superfícies de p-Si (100) em condições de circuito aberto e de polarização anódica em meios contendo fluoretos. Foram utilizadas soluções de NH4F de diferentes concentrações, pH e tipo de solvente (água e metanol). A partir dos testes realizados avaliou-se a taxa de dissolução do silício e a morfologia resultante foi observada. Os resultados obtidos mostram que a taxa de dissolução aumenta com a concentração de fluoretos na solução. Com relação ao pH, foi observado que o ataque em meios ácidos é mais intenso em profundidade, produzindo superfícies porosas para qualquer condição testada. O efeito do solvente foi mais pronunciado nos ensaios em que a amostra foi polarizada. Evidenciando-se, assim, a possibilidade de obtenção de diferentes acabamentos superficiais pelo controle das condições adequadas de composição do meio (concentração de fluoretos, pH e solvente). / The silicon surfaces preparation in microelectronical industry is carried out generally by processes involving one wet step with alcaline or fluoride solutions. Such systems cause different superficial structures: by dissolution in presence of strong alcalis involving reactions of anisotropic nature or by the use of fluoride solutions, whose the largest technological application is due to isotropic chemical etching. The present work investigated the behavior of p-Si (100) under open circuit and anodic polarization conditions in solutions containing fluoride. NH4F solutions with different concentrations, pH and solvent (water and methanol) were used. The silicon dissolution rate was evaluated based on the tests carried out and the surface morphology was observed. The results obtained shown that the silicon dissolution rate increases with the fluoride concentration in the solution. Regarding to pH, we noted that the etching in acid solutions is deeper than in alcaline solutions, this kind of etching resulting in the formation of porous layers on the surface to any condition investigated. The solvent effect was observed when the samples were polarized. The results become evident, therefore, the possibility to obtain different superficial structures by the contrai of suitable conditions of solution composition (fluoride concentration, solution pH and solvent).
328

Revestimentos de nióbio obtidos por aspersão térmica hipersônica (HVOF) sobre aço API 5CT P110

Noronha, Leandro Câmara January 2014 (has links)
Neste trabalho amostras de API 5CT P110 foram revestidas com nióbio empregando-se o processo de Aspersão Térmica Hipersônica HVOF (High Velocity Oxi-Fuel Flame). Previamente à aspersão com nióbio, o substrato foi preparado conforme recomenda a norma da Petrobras (N2568, 2011), sendo que após o processo de aspersão foram realizadas as caracterizações quanto à resistência à corrosão em solução contendo cloretos e quanto à fragilização por hidrogênio. Os revestimentos também foram caracterizados quanto à morfologia por microscopia eletrônica de varredura, análises metalográficas, de microestrutura, aderência e dureza. O revestimento obtido apresentou uma boa resistência à corrosão. Além disso, realizou-se o ensaio com carregamento prévio com hidrogênio, onde o substrato apresentou uma redução na tenacidade praticamente desprezível comparativamente ao substrato sem revestimento e sem carregamento prévio. Isto indica que o revestimento obtido parece atuar como barreira ao ingresso de hidrogênio no aço API 5CT P110. / In this work, samples of API 5CT P110 were coated with niobium employing the thermal spray process Hipersonica HVOF (High Velocity Oxy-Fuel Flame). Prior to spraying with niobium, substrate was prepared as recommended by the norm of Petrobras ( N2568 , 2011) , and after the process of spraying, the characterizations for resistance to corrosion in chloride-containing solution and to hydrogen embrittlement were performed. The coatings were also characterized for morphology by scanning electron microscopy hardness, metallographic, microstructure and adhesion analyses. The obtained coating had good corrosion resistance. Moreover , we performed the test with prior loading with hydrogen, the substrate showed a negligible reduction in toughness compared to the uncoated substrate without preloading. This indicates that the coating obtained seems to act as a barrier to the entry of hydrogen in API 5CT P110 steel.
329

Efeito da adição de inibidores de corrosão em filmes a base de TEOS/Acetato de celulose sobre o comportamento eletroquímico da liga de alumínio AA2024-T3

Wollman, Tatiana Inhaquite January 2006 (has links)
A liga AA2024-T3 é uma liga de alumínio extensivamente empregada na indústria aeronáutica, cujo segundo elemento principal da liga é o cobre. A presença de partículas intermetálicas provoca baixa resistência à corrosão por pites. Com o intuito de prevenir a corrosão, vários tratamentos de superfície têm sido avaliados, entre os quais os filmes sol-gel têm grande destaque. O objetivo deste trabalho é a obtenção, desenvolvimento e caracterização de filmes de acetato de celulose (AC) combinado com tetraetilortosilicato (TEOS) para proteção contra a corrosão da liga de alumínio AA2024-T3 em NaCl 0,05 mol L-1. Além disso, foi investigado o efeito da quantidade relativa entre AC e TEOS sobre o comportamento eletroquímico da liga metálica revestida. Diferentes inibidores de corrosão forma incorporados na matriz AC e TEOS. As propriedades anticorrosivas da liga com os filmes foram estudadas usando espectroscopia de impedância eletroquímica (EIE) durante sete dias de imersão no meio corrosivo. A composição química dos filmes foi determinada por espectroscopia de infravermelho (FT-IR), enquanto a morfologia foi examinada através de Microscopia Eletrônica de Varredura (MEV). Verificou-se que revestimentos obtidos a partir de soluções contendo 70% (m/m) de TEOS e 30% (m/m) de AC e 1.10-3 mol L-1 nitrato de cério propiciaram melhor a resistência à corrosão da liga AA2024 para tempos prolongados de imersão. / The aluminum alloy 2024-T3 is extensively employed in the aerospace industry and copper is the second alloying element. The presence of intermetallic particles causes low resistance to localized corrosion. In order to prevent the corrosion, several surface treatments have been evaluated, being sol-gel films the most prominent. The aim of this work is to obtain, develop and characterize films of cellulose acetate (AC) combined with tetraethylortosilicate (TEOS) for corrosion protection of aluminum alloy 2024-T3 in NaCl 0.05 mol L-1 solution. In addition, the effect of the AC and TEOS ratio on the electrochemical behavior of the coated metal surface was investigated. Different corrosion inhibitors were incorporated into the sol-gel solution. The anticorrosive properties of the alloy with the films were studied using electrochemical impedance spectroscopy in different immersion times. The chemical structure of the films was determined by infrared spectroscopy, while the morphological was examined by scanning electron microscopy. It was verified that the coatings obtained from solutions containing 70% (w/w) of TEOS, 30% (w/w) of cellulose acetate and 1.10-3 mol L-1 of cerium nitrate provided the best corrosion resistance to AA2024-T3 for prolonged immersion times.
330

Evaluating the corrosion protection of post-tensioning grouts : standardization of an accelerated corrosion test

Pacheco, Alexandre Rodrigues January 2003 (has links)
Post-tensioning grouts, typically a mixture of cement and water (sand, mineral chemical admixtures can also be used), are not only designed to transfer stresses between cables and precast concrete, but also to protect prestressing strands against corrosive phenomena. A recent concern regarding post-tensioned structures is the possibility that corrosive agents may reach grouted steel tendons and start a sequence of events culminating in catastrophic collapse. This possible scenario motivated the creation of the Accelerated Corrosion Test (ACT) intended to measure the degree of corrosion protection for grouts used in post-tensioning applications. This test is currently recommended by the Post-Tensioning Institute (PTI). Although already in use, the ACT is not fully developed and researchers have been pointing out the need for further studies to evaluate the influence of the IR drop effect on ACTs (a loss in the applied potential due to the resistivity of corrosion cells) because this phenomenon is likely to skew results for grouts of significant different resistivity. Five different categories of grout (plain, prepackaged, with corrosion inhibitors, with silica fume, and with fly ash) were tested in an electrochemical setup capable of compensating for IR drop effects. Procedures are recommended for adoption in an improved version of the ACT standard.

Page generated in 0.066 seconds