• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Optimisation of a Powder Dosing Equipment / Optimering av en pulverdoseringsutrustning

Codo Morales, Andrea January 2023 (has links)
Klimatförändringar är en av de viktigaste problemen som påverkar framtida generationer. För att bekämpa detta införlivar Northvolt hållbara metoder genom hela batteriproduktionsprocessen. Ett avgörande steg i elektrodtillverkningen är slurryblandningen, vilket innebär att man kombinerar flera pulver inklusive det aktiva materialet. Det aktiva materialet doseras in i mixern med hjälp av pulverdoseringsutrustning. En omfattande studie har genomförts på pulverdoseringsutrustningen för att minska produktionstiden och förbättra kvaliteten på slurryn. Efter att ha förstått utrustningens funktioner och genomfört inledande tester på både anoden och katoden, föreslogs nya justeringar. Med de nyligen genomförda justeringarna observerades en betydande minskning av produktionstiden med 50 % i anoden och därför minskade även energiförbrukningen vid dosering. Det är viktigt att notera att stora skillnader mellan anod och katod observerades på grund av olika kemikalieanvändning. Slutligen har denna studerade framgångsrikt uppnått en minskning av produktionstid och energiförbrukning genom att optimera pulverdoseringsutrustningen som används i anod. / Climate Change is one of the main concerns affecting future generations. To combat this, Northvolt incorporates sustainable practices throughout the battery production process. One crucial step in electrode manufacturing is the slurry mixing, which involves combining several powders including the active material. The active material is dosed into the mixer using powder dosing equipment. An extensive study has been carried out on the powder dosing equipment to reduce production time and improve the quality of the slurry. After understanding the equipment’s functionalities and conducting initial tests on both the anode and cathode, new adjustments were suggested. With the newly implemented adjustments, a significant reduction in production time by 50% was observed in the anode and therefore the energy consumption during dosing also decreased. It is important to note that big differences between anode and cathode were observed due to different chemical usage. Finally, this studied has successfully achieved a reduction in production time and energy consumption optimising the powder dosing equipment used in anode.
2

Time series analysis of ground frost conditions at Abisko, sub-Arctic Sweden, 1985-2010 / Tidserieanalys av marktemperatur i Abisko,Norra Sverige, under perioden 1985-2010

Schmidt, Anja January 2012 (has links)
Observed climatic change may result in modification of the ground thermal regime.The causes of shallow ground temperature variability, however, are not well documented.This thesis reports ground temperatures from Absiko Scientific Research Station, measured ata site currently not underlain by permafrost to illustrate the response of shallow groundtemperatures to changes in climatic parameters. Both air temperature and precipitationincreased at Abisko from 1985-2010. The strongest increase in air temperature occurred inwinter, whereas the precipitation increased mainly during the summer months. There was asignificant trend towards later onset of permanent snow cover, as well as a steadily earlierdisappearance of permanent snow cover in spring, resulting in reduced snow cover duration.Also the snow thickness decreased at Abisko during the study period. The ground experiencedapproximately five months of frost at 5 and 20 cm depth and approx. four, respectively two,months at 50 and 100 cm depth. Annual ground temperatures were found to be increasingfrom 1985-2010 with approx. 0.31 °C, 0.64 °C, 0.82 °C and 0.94 °C at 5, 20, 50, respectively100 cm depth from the surface. The duration and intensity of the seasonal frost cycles weredecreasing, which would reflect the increasing ground temperatures. Changes in short-termfrost cycles were not found to be significant. The changes in mean annual and winter groundtemperature were significantly correlated to the changes in mean annual and winter airtemperature, but surprisingly not to the changes in snow cover. However, seasonally theincreasing trend of ground temperatures was found in autumn and winter, whereas thesummer ground temperatures were decreasing. The cooling of ground temperature in summerat increasing air temperatures may be explained by increased precipitation totals and henceincreased soil moisture due to the so called soil-moisture feedback. From this fact, it can bededuced that the changes in air temperature alone cannot explain all variances in groundtemperatures. However, the results of the study may suggest that in sub-Arctic Swedenchanges in air temperatures may be used as indicator for changes in shallow groundtemperatures. / perioden 1985-2010 ökade både lufttemperatur och nederbörd i Abiskoområdet. Denstörsta ökningen av lufttemperatur skedde under vinterhalvåret medan nederbörden ökademest under sommarhalvåret. En signifikant förkortning i längden av vintersnötäckets existensunder året observerades under studieperioden. Reduceringen av vintesnötäcket skedde genomatt den första snön kom senare och bortsmältningen på våren skedde tidigare. Snötäcketstjocklek minskade också under studieperioden. Marktemperaturmätningarna visar frysgraderpå 5 och 20 cm djup fem månader och fyra respektive två månader på 50 och 100cm djup.Den årliga medeltemperaturen i marken ökade under perioden med 0.31 °C, 0.64 °C, 0.82 °Coch 0.94 °C vid 5, 20, 50 och 100 cm djup. Den årliga längden och intensiteten avfrysförhållandena i marken minskade vilket förmodligen är en konsekvens av de ökandemarktemperaturerna. Ingen trend i förekomsten av kortare svängningar i frysförhållandenakunde observeras. Förändringarna i årsmedetemperaturen i marken är signifikant korrelerademed förändringen i den årliga medeltemperaturen och vintertemperaturen i luften, men ingenkorrelation mellan marktemperaturen och förändringar i snötäckets tjocklek och längdobserverades. Studien avslöjade också att temperaturen i marken ökade under vinternhalvåretmedan den sjönk under sommaren. Avkylningen av marken under sommaren kan förklaras avökad nederbörd under sommaren som ger högre markfuktighet som ger en kylande effektgenom den så kallade jord-fuktighets återkopplingsmekanismen (soil-moisture feedback).Från detta kan vi dra slutsatsen att förändringar i enbart lufttemperatur inte kan förklara denhela observerade variansen av marktemperatur men att lufttemperaturen har en domineranderoll. Resultaten från denna studie indikerar således att förändringar lufttemperatur kananvändas som en indikator på marktemperaturförändringar i Abisko området.

Page generated in 0.0239 seconds