1

Etude de l'optimisation des isolants d'un point de vue diélectrique pour les contraintes du GIS

Caliap, Lucian 16 September 2010 (has links) (PDF)
Cette étude concerne les isolants support, utilisés dans l'appareillage haute tension blindé sous pression gazeuse. La réduction de la taille du matériel est une demande constante pour des questions de coût. Elle impacte directement les isolants et l'optimisation diélectrique est rendue nécessaire. On peut considérer que les points qui nécessitent une attention particulière sont : La zone de point triple : point de jonction entre un isolant, le gaz et le métal, zone sensible aux décharges partielles et aux particules qui peuvent s'y accumuler. Les particules métalliques qui peuvent se trouver à l'intérieur du système haute-tension et les problèmes d'accumulation de la charge sur la surface de l'isolant qui peuvent réduire sa tenue diélectrique lors de l'application d'une surtension. Ces trois points représentent la base de départ de cette étude qui caractérise la multitude de phénomènes complexes qui apparaissent en présence de haute tension.
2

Etude de l'optimisation des isolants d'un point de vue diélectrique pour les contraintes du GIS

Caliap, Lucian 16 September 2010 (has links) (PDF)
Cette étude concerne les isolants support, utilisés dans l'appareillage haute tension blindé sous pression gazeuse. La réduction de la taille du matériel est une demande constante pour des questions de coût. Elle impacte directement les isolants et l'optimisation diélectrique est rendue nécessaire. On peut considérer que les points qui nécessitent une attention particulière sont : La zone de point triple : point de jonction entre un isolant, le gaz et le métal, zone sensible aux décharges partielles et aux particules qui peuvent s'y accumuler. Les particules métalliques qui peuvent se trouver à l'intérieur du système haute-tension et les problèmes d'accumulation de la charge sur la surface de l'isolant qui peuvent réduire sa tenue diélectrique lors de l'application d'une surtension. Ces trois points représentent la base de départ de cette étude qui caractérise la multitude de phénomènes complexes qui apparaissent en présence de haute tension.
3

Etude de l'origine des décharges partielles sur des substrats céramiques enrobés

Vu Thi, Anh Tho 13 July 2011 (has links) (PDF)
Ce travail concerne l'étude du phénomène de décharges partielles dans les matériaux isolants utilisés en électronique de puissance. En utilisant des méthodes de détection électrique et optique, le mécanisme de décharge partielle sur des substrats d'AlN dans l'huile silicone a été étudié sur un grand nombre d'échantillons. La variation de la nature du substrat (AlN, Al2O3 et composite verre/époxy) et du matériau d'encapsulation (huile silicone, huile de colza, huile minérale de transformateur, liquide d'imprégnant du condensateur Jarylec et Ugilec) met en évidence l'origine des décharges partielles de l'ensemble substrat - encapsulant. Les décharges partielles sur les substrats céramiques frittés ne dépendent pas du passivant, et se produisent dans le volume du substrat. L'évolution temporelle de la lumière émise dans les liquides en configuration pointe - plan et sur le substrat dans différents liquides montre que l'émission de lumière est un phénomène très complexe influencé par de nombreux paramètres : électroluminescence du solide, de l'encapsulant, décharges partielles, absorption des matériaux. Le phénomène d'électroluminescence du liquide est activé par une illumination extérieure. Les mesures de spectroscopie diélectrique haute tension n'apportent pas d'information supplémentaire sur le phénomène de décharges partielles, car les pertes correspondantes sont très faibles. Mots clés : Décharge partielle, électroluminescence, Nitrure d'aluminium, Alumine, huile silicone, diélectrique liquide, électronique de puissance.
4

Research on insulation performance of SF6 substitute CF31/CO2 under power frequency voltage and the influence of micro-moisture on CF31 / Etude du pouvoir de coupure du CF3I en présence de CO2 et de particules métalliques comme substitute au SF6 : influence de la tension d'alimentation, de l'uniformité du champ électrique et de la présence de moisissures

Xiao, Song 21 July 2016 (has links)
Les appareillages utilisant des gaz de coupure se sont fortement développés dans les réseaux haute et ultra-haute tension de par leur grande stabilité, leur faible maintenance, faible surface au sol, et leur configuration flexible. De nos jours, le SF6 est utilisé comme gaz principal dans la majeure partie des équipements de coupure haute tension, mais il reste un gaz à effet de serre dont les émissions sont néfastes pour l'environnement. Il devient donc indispensable de trouver des solutions alternatives au SF6 dans ces dispositifs électriques, comme son remplacement par des gaz moins polluants. Dans une optique de certification, des tests sont réalisés systématiquement pour évaluer les caractéristiques d'isolation du mélange sous une tension de fonctionnement, ici du CF3I/CO2. Les caractéristiques isolantes du gaz pur CF3I et des mélanges CF3I/CO2 sont testées sous différents types de défaut et l'influence des particules métalliques est évaluée au travers des propriétés thermodynamiques et des propriétés de transport d'un plasma CF3I contaminé par ces particules. Les performances globales du CF3I/CO2 (électriques et thermiques) sont donc évaluées sous des contraintes typiques et pour des matériaux métalliques différents. Enfin, l'impact de l'humidité (aléatoirement présente dans les dispositifs) sur la tenue diélectrique de l'appareil est étudié car sa présence peut avoir des conséquences dramatiques. / A large amount of gas insulated equipment are applied widely as the key part of power system. Gas insulated equipment develop quickly and used widely in high and ultra-high voltage field owing to its high stability, less maintenance work, smaller floor space, and flexible configuration. Nowadays, SF6 is adopted as the main insulation medium of gas insulated equipment, which is considered a kind of dangerous greenhouse gas to environment. Global climate warming caused by greenhouse effect brings disastrous consequences to our living conditions. Electric devices account much for the emission of SF6, which makes it urgent to find a kind of environment-friendly substitute insulating gas. Besides, the decomposed products of SF6 under discharge may be corrosive to internal material and poisonous to power workers. In the early period of global research and development of environment-friendly insulated devices, mastering the formula and key technique of substitute gas is vital to electrical development. According to the above circumstance, systematic investigation of the insulating characteristics of CF3I/CO2 mixed gases under power-frequency voltage was carried out firstly, which could provide useful information for the best mixed ratio of CF3I/CO2 and the design of internal structure in matching devices. Then insulating characteristic of CF3I/CO2 and CF3I were tested under a kind of normal insulating defect of free metal particles defect, and the influence of metal particles on the thermodynamic characteristics and transmission properties of CF3I discharge plasma were calculated theoretically. The overall performance of CF3I/CO2 under typical defects were tested for the choice of internal metal materials of electrical devices. Finally, the influence of moisture, the main hazardous material on gas insulated equipment, on the insulating performance of CF3I were conducted experimentally and theoretically, which proved the harmful effect of moisture on the new insulating medium and provided theoretical foundation for the standard constitution of moisture content.
5

Etude diélectrique des isolants plats anodisés pour la conception de machines électriques / Dielectric study of flat anodized insulations for electrical machine design

Babicz, Sylvain 06 December 2016 (has links)
L’augmentation de la classe de température des machines électriques tournantes atteint son maximum avec des vernis organiques spéciaux pouvant supporter jusqu’à 280 °C. La rupture technologique se trouve alors dans la substitution d’un vernis organique par une matière inorganique. La famille des céramiques répond aux critères. Ces céramiques sont de bons diélectriques et résistent à de fortes températures. Dans ces travaux, le conducteur étudié se présente sous la forme d’un ruban et se compose d’une âme conductrice en aluminium, dont la couche isolante a été obtenue par le processus électrochimique d’anodisation. Ce processus permet de faire croître sur l’aluminium une couche d’alumine de quelques micromètres. L’objectif de ces travaux de thèse est de caractériser ce type de conducteur pour démontrer la possibilité ou non de l’utiliser comme conducteur pour la réalisation de bobinages pour des machines dites « hautes températures », pouvant fonctionner jusqu’à des températures ambiantes de 400 °C. Des mesures de TADP, TEDP, tensions de claquage sont effectuées sous des conditions environnementales variables (hautes températures, températures négatives, humidité variable). Les actionneurs réalisés avec ce type de conducteur seront alimentés par un convertisseur provoquant des fronts raides et des surtensions. Un modèle théorique de bobine est donc proposé, basé sur l’étude du spectre d’impédance de celle-ci, et permettant de prédire l’amplitude du premier dépassement suite à un front raide. L’amélioration de l’isolation des bobines se fait par une imprégnation à l’oxyde de bore, après confection des bobines, renforçant la couche d’alumine sur les bords du ruban. / The use of state of the art organic enamels, capable to withstand 280 °C, makes the temperature class increase of electrical machine reaching its maximum. A technological breakthrough can be found by the substitution of organic enamel by a ceramic based insulation. Those materials are good dielectrics and their temperature resistance is very high compared to a classical technology. In this work, the studied conductor is an aluminum tape which insulation is obtained by an anodisation, an electrochemical process. This surface treatment makes the aluminum oxidizing: a thin layer of a few micrometres is obtained, thus representing the insulation layer of the conductor. The objectives of those PhD works is to identify and characterize this particular type of conductor so as to demonstrate the ability of using an anodized aluminum tape to makeelectrical machine running up to 400 °C. Measurements of PDIV, PDEV, and breakdown voltage are carried under various environmental conditions (temperatures varying from -70 °C up to 650 °C, variable humidity level). The use of an inverter to supply this high temperature machine induces steep fronts and over voltages. As a consequence, a theoretical model of a coil, made with this kind of conductor, is then proposed and based upon the impedance spectrum of the coil. The aim of this model is to help the designer to predict the first over voltage amplitude and to make the insulation of the first coil according to that. At least, a coil insulation improvement is depicted, using boron oxide: an impregnation is held to reinforce the alumina layer on the edge of the tape
6

Etude des décharges partielles dans une chambre à fission haute température / Study of partial partial-discharge-induced pulses in a high temperature fission chambers

Galli, Giacomo 19 December 2018 (has links)
Le Commissariat à l'Energie Atomique et aux Energies Alternatives (CEA) a en charge la conception d'un réacteur à neutrons rapides de quatrième génération.L'instrumentation neutronique de ce futur réacteur s'appuiera sur des chambres à fission placées en cuve. Ces chambres à fission à haute température (CFHT) devront fonctionner à pleine puissance à une température comprise entre 400°C et 650°C.Un bilan récent de la technologie CFHT a révélé que certains points sont à améliorer afin d'en garantir une plus grande fiabilité.En particulier, on recherche une meilleure compréhension du phénomène de décharges partielles. Celles-ci engendrent des impulsions non discernables de celles produites par les fragments de fission du dépôt fissile.Par ailleurs, elles pourraient accélérer le vieillissement des isolants minéraux.En s'appuyant sur une démarche expérimentale et théorique, ce travail de thèse a apporté plusieurs résultats.Les tests sur les différentes chambres à fission ont permis de caractériser les signaux de DP, vis à vis des signaux neutroniques et de trouver une méthode efficace de discrimination DP-neutron. De la même manière, les signaux DP ont été localisés et une solution technologique a été proposée et mise en oeuvre avec succès pour les éliminer.Un outil de calcul pour la simulation des impulsions neutroniques a été conçu et testé avec succès.Une expérience sur l'effet de la température sur la courbe de Paschen, dans un volume de gaz fermé, a été conçue et réalisée en donnant les premiers résultats intéressants. / The Commission for Atomic and Alternative Energy (CEA) is in charge of the fourth generation fast neutron reactor design. The instrumentation for neutron flux measurement of this future reactor will be based on fission chambers placed in-core. These high temperature fission chambers (HTFC) will have to operate at full reactor power, and thus at a temperature between 400°C and 650°C.A recent review of HTFC technology has revealed that some points need improvement to ensure greater reliability.In particular, a better understanding of the phenomenon of partial discharges (PD), which are observed in the fission chambers at high temperature, is needed. These PD pulses are indistinguishable from those produced by the products of fission caused by collision with neutrons with the fissile deposit within thechambers.In addition, they could accelerate aging of the ceramic insulators used in the chambers.Based on both experimental and theoretical approaches, this PhD work found several results.Tests on different fission chambers made it possible to characterize the DP signals vis-a-vis the neutron signals and to find an operational DP-neutron discrimination method. The DP signals were localized and a technological solution was proposed and successfully implemented to eliminate them.A calculation tool for neutron pulse simulation was also designed and tested successfully.An experiment on the effect of temperature on the Paschen curve, in a closed gas volume, was designed and carried out giving initial interesting results.
7

Caractérisation des décharges partielles et identification des défauts dans les PSEM sous haute tension continue / Characterization of Partial Discharges and Defect Identification in High-Voltage Direct Current GIS

Ouss, Etienne 24 September 2018 (has links)
Cette thèse s’inscrit dans le contexte de la surveillance des postes sous enveloppe métallique (PSEM) en courant continu (DC). La disponibilité de ces équipements étant primordiale pour leurs utilisateurs, il est nécessaire de disposer d’un outil de surveillance (monitoring) permettant de prévenir toute défaillance. Cet outil doit être capable de détecter et d’identifier les défauts présents, afin d’apporter une réponse adaptée. Depuis de nombreuses années, le monitoring des PSEM en AC est réalisé grâce à la mesure des décharges partielles (DP). Malheureusement, les connaissances des DP dans les PSEM en DC sont encore lacunaires, et les techniques d’identification des défauts sont intrinsèquement liées à l’environnement AC. De nouvelles techniques sont donc nécessaires en DC.Ce travail de thèse avait pour but de caractériser les décharges partielles dans les postes sous enveloppe métallique en tension continue, et de mettre en place une solution de reconnaissance automatique des défauts. Pour cela, un banc de mesure des décharges partielles a d’abord été mis en place. Afin de garantir la pertinence des résultats pour des systèmes industriels, les travaux ont été réalisés dans une section de PSEM sous tension continue. Le comportement des DP a été étudié pour deux types de défauts : des pointes sur le conducteur haute-tension et des particules libres métalliques. La caractérisation a porté sur l’influence de plusieurs paramètres : la nature et la pression du gaz, le niveau et la polarité de la tension. La mesure des DP a d’abord été réalisée en conformité avec la norme IEC 60270, permettant ainsi d’évaluer la pertinence de cette méthode pour les applications DC. La caractérisation a été complétée grâce à d’autres chaînes de mesure : une mesure de courant stationnaire, une mesure de courant haute-fréquence, une mesure de lumière, et une mesure des ondes ultra-haute fréquence (UHF). Le travail sur l’identification des défauts a d’abord consisté à construire une signature pertinente à partir des mesures de DP, puis à constituer une base de données, et enfin à implémenter un algorithme de reconnaissance automatique.Ces travaux ont montré que la méthode conventionnelle de mesure des DP présente certaines limites pour la détection des décharges partielles en DC, notamment pour les décharges couronne. Elle a tout de même permis de faire une bonne partie du travail de caractérisation. Les résultats obtenus avec les autres chaînes de mesure utilisées ont permis d’expliquer les lacunes de la méthode conventionnelle. Ils ont également permis un véritable apport pour la caractérisation des DP engendrées par des défauts de type pointe et particule. Enfin, une classification automatique efficace des défauts a été mise en place. Elle s’appuie sur le diagramme q(Δt) issu des données de la mesure conventionnelle des décharges partielles et sur un algorithme de réseau de neurones. / The framework of this thesis is the monitoring of High-Voltage, Direct Current (HVDC) Gas-Insulated Substations (GIS). The availability of these equipment is crucial for electrical networks operators. That is why they need a preventive diagnosis tool. The solution must be able to detect and identify the insulation defects, so that an appropriate maintenance can be planned. The last 40 years have seen Partial Discharges (PD) measurement become a classic monitoring tool for AC GIS. Unfortunately, there is a lack of scientific information about PD in HVDC GIS, and the known defect identification techniques are very specific to the AC environment. New techniques are thus needed in DC.This thesis aimed to characterize partial discharges in DC gas-insulated substations, and to develop an automatic defect identification tool. The first step of this work was the development of a partial discharge measuring bench. The complete study has been performed in a GIS section, so that the results can be directly applied to industrial equipment. Two kinds of defect have been investigated: protrusions on the high-voltage conductor, and free metallic particles. The influence of parameters such as gas nature and pressure, voltage level and polarity has been evaluated. First, PD have been measured in conformity with the IEC 60270 standard, and the relevance of this method in a DC environment has been evaluated. Then, other measuring chains have been used to improve the characterization of partial discharges: a steady-state current measurement, a high-frequency current measurement, a light measurement and a measurement of Ultra-High Frequency (UHF) waves. Finally, a relevant signature for defect identification has been designed and extracted from DP recordings. A database has been constituted, and an automated recognition algorithm has been implemented.The results show that the conventional PD measurement technique is not fully adapted to partial discharges detection in DC, corona discharges being the most problematic situation. Nevertheless, this method has brought enough information to start the characterization of PD. The limitations of the conventional method have been explained thanks to the results of the other measurements. These other experimental results have led to an actual improvement of the characterization of protrusion and particle-generated partial discharges. An effective automated defect classification solution has been implemented. The signature is derived from the q(Δt) diagram that has been extracted from the data obtained with the partial discharge conventional measurement. The identification algorithm has a neural network structure.