• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caractérisation et suivi du dégazage des principaux édifices volcaniques actifs de l'arc insulaire du Vanuatu par télédétection

Bani, Philipson 14 November 2006 (has links) (PDF)
Les développements récents sur les applications des spectromètres UV miniaturisés pour la mesure des flux de gaz volcaniques ont ouvert la possibilité de mesurer régulièrement le dégazage de volcans isolés, dont les flux de SO2 n'avaient jamais, ou rarement, été mesurés. Au Vanuatu, le dégazage d'un seul volcan sur six aériens actifs a été mesuré (1999). Cette thèse décrit les travaux réalisés sur l'étude du dégazage de quatre des édifices actifs de cet arc insulaire. Ils ont permis de mettre en évidence d'importantes sources permanentes de SO2 et d'halogènes sur les édifices volcaniques des îles d'Ambrym et de Tanna; des mesures de dégazages ont également été effectuées lors des manifestations éruptives sur les îles d'Aoba/Ambae et de Lopevi. Il ressort que les volcans du Vanuatu sont de très importantes sources de SO2 et d'halogènes. Ces sources naturelles d'émissions, liées à des manifestations volcaniques permanentes et cycliques, étaient peu connues et non prises en compte dans des bilans globaux. L'estimation minimum du flux de SO2 libéré par quatre édifices (Aoba, Ambrym, Lopevi, Yasur) du Vanuatu se situe autour de 61 kg/s, ce qui représente entre 11 et 20 % du flux global moyen de SO2 rejetés dans l'atmosphère par les volcans de la planète. Le dégazage perturbe l'écosystème, génère des pertes importantes sur les plantes et cultures dont dépendent les ni-vanuatais pour subsister. Il menace épisodiquement leur sécurité. Son étude est un apport significatif à la quantification du risque volcanique sur l'Archipel.
2

Imaging measurements of volcanic SO2 using space and ground based sensors / Mesures imageantes du SO2 volcanique depuis l'espace et le sol

Campion, Robin 17 June 2011 (has links)
Sulfur dioxide (SO2) is a gas typical of high temperature magmatic degassing, being its<p>third most abundant constituent after water vapor and carbon dioxide. SO2 flux measurements<p>are used to characterized and monitor volcanic degassing. This thesis presents advanced<p>methods for measuring the SO2 emitted in the troposphere by passive degassing volcanoes.<p>These methods are based on the absorption of infrared (IR) and ultraviolet (UV) light by SO2<p>molecules. They make use of the data acquired by satellite borne sensors (ASTER, OMI and<p>MODIS), and collected in the field using a UV camera equipped with filters<p>ASTER is a multispectral sensor observing the Earth in the thermal IR with a 90 m<p>ground resolution. The developed retrieval algorithm works with band ratios<p>(B10+B12)/2B11 and B14/B11, to avoid spectral interference from other variables than SO2.<p>With this algorithm, the impact of interferers such as atmospheric water vapor, sulfate<p>aerosols and ground emissivity is minimal, as demonstrated by radiative transfer simulations<p>by applying of the algorithm to real ASTER images and by comparing the results with ground<p>based data. ASTER is a kind of unifying thread for this thesis because its high ground<p>resolution fills the gap existing between highly localized ground based SO2 measurements and<p>the global coverage of other satellites with coarser pixels such as OMI and MODIS.<p>OMI is an imaging spectrometer operating in the UV, with a daily global coverage, a<p>high sensitivity to SO2 and a ground resolution of 13x24km. The OMI-ASTER comparison<p>shows that the SO2 columns measured on OMI pixels are two orders of magnitude smaller<p>than those of ASTER, because of the huge difference in the pixel size of the two satellites.<p>The flux measurements however are generally in good agreement. The analysis of a large<p>number of images shows that ASTER is better for cloud free scenes while OMI has an<p>optimal signal to noise ratio when the plume is lying above a low cloud cover. A practical<p>detection limit for SO2 flux measurements in tropospheric plumes has also been established:<p>5kg/s.<p>The comparison between ASTER measurements of SO2 column amounts with those of<p>MODIS (a multispectral IR imager with 1km ground resolution) shed light on systematic<p>errors in MODIS measurements. These errors were quantified and their origins were separated<p>and identified. This work demonstrates the limitations of MODIS for SO2 measurements.<p>A UV camera equipped with filters has also been developed to achieve 2D SO2 from the<p>ground at a high spatial and temporal resolution. The potential provided by this new type of<p>instruments has been demonstrated during a field campaign on Turrialba Volcano (Costa<p>Rica). The integration of measurements obtained using the camera, ASTER and OMI revealed<p>a high and sustained SO2 flux, which can be explained only by the degassing of a recently<p>intruded magma body. The slow decrease of SO2 flux since January 2010 suggests a<p>progressive exhaustion of the volatile content of the magma.<p>Finally, we applied the band ratio algorithm to a series of ASTER images of the recent<p>eruption of Eyjafjallajökull in April-May 2010. The SO2 measurements provide interesting<p>insights into the complex eruptive dynamics and into the control of hydromagmatic<p>interactions on eruptive gas release into the atmosphere. /<p><p>Le dioxyde de soufre (SO2) est un gaz typique du dégazage magmatique de haute<p>température, dont il est le troisième composant le plus abondant derrière H2O et CO2. Le flux<p>de SO2 est un excellent paramètre pour caractériser le dégazage volcanique et surveiller son<p>évolution dans le temps. Cette thèse présente de nouvelles méthodes de mesures des flux de<p>SO2 émis par l’activité volcanique. Ces méthodes se basent sur l’absorption de la molécule de<p>SO2 dans l’infrarouge (IR) et l’ultraviolet (UV). Elles utilisent les données prises par des<p>senseurs embarqués sur des satellites (ASTER, OMI et MODIS) ou opérés depuis le sol<p>(caméra UV munie de filtres).<p>Le senseur ASTER opère dans l’IR thermique avec une résolution spatiale de 90 m par<p>pixel. L’algorithme de mesure développé pour ce satellite n’est sensible qu’à la concentration<p>en SO2 et pratiquement pas aux paramètres interférents qui posaient problèmes aux méthodes<p>existantes :la vapeur d’eau atmosphérique, les aérosols de sulfate dans le panache et<p>l’émissivité de la surface sous-jacente. ASTER est un peu le fil conducteur de cette thèse, car<p>sa haute résolution spatiale lui permet de faire le lien entre des mesures au sol et les mesures<p>faites par d’autres satellites comme OMI et MODIS.<p>Le satellite OMI est un spectromètre imageant qui opère dans l’UV, avec une<p>couverture globale journalière, une haute sensitivité au SO2 et une résolution spatiale de<p>13x24km. La comparaison OMI-ASTER montre que les colonnes mesurées sur les pixels<p>d’OMI sont de deux ordres de grandeur inférieurs à celles d’ASTER, à cause de la différence<p>de résolution spatiale entre les deux satellites. Les mesures de flux, par contre, montrent une<p>très bonne concordance. L’analyse d’un grand nombre d’images a permis d’établir qu’ASTER<p>est meilleur pour des scènes sans nuages tandis qu’OMI est meilleur quand une couverture<p>nuageuse présente sous le panache augmente son rapport signal sur bruit. Une limite de<p>détection pratique a aussi été établie pour les flux de SO2 dans les panaches volcaniques dans<p>la basse troposphère :5kg/s.<p>La comparaison des mesures d’ASTER avec celle de MODIS a permis de démontrer les<p>limites de MODIS pour la mesure du SO2. Des erreurs systématiques sur les mesures de<p>MODIS on été mises en évidence et quantifiées. Ces erreurs sont dues aux interférents<p>spectraux que sont la vapeur d’eau atmosphérique et les aérosols sulfatés. L’émissivité est<p>aussi un important facteur d’erreur pour MODIS.<p>Une caméra UV équipée d’un système de filtres a également été développée pour<p>mesurer le SO2 en 2D, à haute résolution spatiale et temporelle. Le potentiel offert par ce<p>nouveau type d’instrument a été démontré lors d’une campagne de mesures sur le volcan<p>Turrialba (Costa Rica). La combinaison de mesures de SO2 réalisée avec la caméra, ASTER<p>et OMI a permis de mettre en évidence des flux très élevés (30-50kg/s) qui ne peuvent<p>s’expliquer que par une intrusion récente de magma juvénile en cours de dégazage.<p>Enfin, les mesures de SO2 ont réalisées à partir des images ASTER pendant l’éruption<p>du volcan Eyjafjallajökull en avril-mai 2010. Ces mesures fournissent des informations<p>intéressantes sur les dynamismes éruptifs qui se sont succédé et sur le contrôle des émissions<p>de SO2 dans l’atmosphère par les interactions magma-eau. / Doctorat en Sciences / info:eu-repo/semantics/nonPublished

Page generated in 0.0474 seconds