• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ajuste oclusal associado à terapia periodontal / Occlusal adjustment associated with periodontal therapy

Foz, Adriana Moura 15 June 2012 (has links)
O ajuste oclusal (AO) como parte da terapia periodontal é um tema controverso, principalmente porque a literatura não fornece evidências suficientes sobre a influência do trauma de oclusão (TO) na doença periodontal (DP). A necessidade de ajuste oclusal na terapia periodontal é considerada incerta e requer investigação. O objetivo desta revisão sistemática foi identificar e analisar estudos que investigaram os efeitos do AO associado à terapia periodontal, sobre os parâmetros periodontais. Um protocolo foi desenvolvido incluindo todos os aspectos de uma revisão sistemática: estratégia de busca, critérios de seleção, seleção de métodos, coleta de dados e extração de dados. A pesquisa bibliográfica foi realizada utilizando MEDLINE via PubMed, Cochrane Central Register de estudos controlados e EMBASE. Os títulos e resumos de artigos foram selecionados de acordo com critérios estabelecidos na metodologia. Cada artigo que indicava uma possível correspondência com estes critérios, ou não poderia ser excluído baseado nas informações presentes no título ou no resumo, foi considerado e avaliado. Na seleção final, quatro artigos foram incluídos. Embora os estudos selecionados sugerem uma associação entre AO e uma melhora nos parâmetros periodontais, suas questões metodológicas (exploradas nesta revisão) sugerem a necessidade de novos estudos com maior qualidade. Atualmente as evidências presentes são insuficientes para presumir que AO é necessário para reduzir a progressão da doença periodontal. / Occlusal adjustment (OA) as part of periodontal therapy is a controversial theme, mostly because the literature does not provide enough evidence regarding the influence of trauma from occlusion (TO) on periodontitis. The need for occlusal adjustment in periodontal therapy is considered uncertain and requires investigation. The aim of this systematic review was to identify and analyze those studies that investigated the effects of OA, associated with periodontal therapy, on periodontal parameters. It was developed a protocol, which included all aspects of a systematic review: search strategy, selection criteria, selection methods, data collection and data extraction. A literature search was conducted using MEDLINE via PubMed, the Cochrane Central Register of Controlled Trials, and EMBASE. Titles and abstracts of articles were selected according to established criteria. Every article that indicated a possible match, or could not be excluded based on the information given in the title or abstract, was considered and evaluated. On final selection, four articles were included. Although the selected studies suggest an association between OA and an improvement in periodontal parameters, their methodological issues (explored in this review) suggest the need for new trials of a higher quality. There is insufficient evidence at present to presume that OA is necessary to reduce the progression of periodontal disease.
2

Ajuste oclusal associado à terapia periodontal / Occlusal adjustment associated with periodontal therapy

Adriana Moura Foz 15 June 2012 (has links)
O ajuste oclusal (AO) como parte da terapia periodontal é um tema controverso, principalmente porque a literatura não fornece evidências suficientes sobre a influência do trauma de oclusão (TO) na doença periodontal (DP). A necessidade de ajuste oclusal na terapia periodontal é considerada incerta e requer investigação. O objetivo desta revisão sistemática foi identificar e analisar estudos que investigaram os efeitos do AO associado à terapia periodontal, sobre os parâmetros periodontais. Um protocolo foi desenvolvido incluindo todos os aspectos de uma revisão sistemática: estratégia de busca, critérios de seleção, seleção de métodos, coleta de dados e extração de dados. A pesquisa bibliográfica foi realizada utilizando MEDLINE via PubMed, Cochrane Central Register de estudos controlados e EMBASE. Os títulos e resumos de artigos foram selecionados de acordo com critérios estabelecidos na metodologia. Cada artigo que indicava uma possível correspondência com estes critérios, ou não poderia ser excluído baseado nas informações presentes no título ou no resumo, foi considerado e avaliado. Na seleção final, quatro artigos foram incluídos. Embora os estudos selecionados sugerem uma associação entre AO e uma melhora nos parâmetros periodontais, suas questões metodológicas (exploradas nesta revisão) sugerem a necessidade de novos estudos com maior qualidade. Atualmente as evidências presentes são insuficientes para presumir que AO é necessário para reduzir a progressão da doença periodontal. / Occlusal adjustment (OA) as part of periodontal therapy is a controversial theme, mostly because the literature does not provide enough evidence regarding the influence of trauma from occlusion (TO) on periodontitis. The need for occlusal adjustment in periodontal therapy is considered uncertain and requires investigation. The aim of this systematic review was to identify and analyze those studies that investigated the effects of OA, associated with periodontal therapy, on periodontal parameters. It was developed a protocol, which included all aspects of a systematic review: search strategy, selection criteria, selection methods, data collection and data extraction. A literature search was conducted using MEDLINE via PubMed, the Cochrane Central Register of Controlled Trials, and EMBASE. Titles and abstracts of articles were selected according to established criteria. Every article that indicated a possible match, or could not be excluded based on the information given in the title or abstract, was considered and evaluated. On final selection, four articles were included. Although the selected studies suggest an association between OA and an improvement in periodontal parameters, their methodological issues (explored in this review) suggest the need for new trials of a higher quality. There is insufficient evidence at present to presume that OA is necessary to reduce the progression of periodontal disease.
3

Monitoramento terapêutico e modelagem farmacocinética de antimicrobianos em pacientes queimados da unidade de terapia intensiva / Therapeutic drug monitoring and pharmacokinetics of antimicrobial agents in burn patients from the Intensive care unit

Vera López, Karin Jannet 14 September 2009 (has links)
A sepse após a injúria térmica é a maior causa de morbidade e mortalidade em pacientes queimados, uma vez que profundas alterações ocorrem na farmacocinética de agentes antimicrobianos. Investigaram-se trinta e um pacientes, portadores de sepse documentada e apresentando lesões ativas; utilizou-se o tratamento empírico conforme seguem os regimes de dose: 1 g, 12/12 h para a vancomicina, 1 g, 6/6 h para o imipenem e 2 g, 8/8 h para o cefepime. Sete coletas seriadas de sangue foram realizadas através de cateter venoso (2 mL/cada); o plasma foi obtido pela centrifugação e armazenado no congelador (-80o C) até o ensaio. A concentração plasmática dos antimicrobianos foi determinada simultaneamente pela aplicação do método bioanalítico desenvolvido no estudo. O método de cromatografia líquida de alta eficiência demonstrou boa linearidade, precisão e exatidão para a determinação simultânea da vancomicina, cefepime e imipenem plasmáticos; a plicação desse método bioanalítico permitiu o monitoramento plasmático terapêutico e o estudo farmacocinético. Com base nos resultados obtidos de concentração plasmática versus tempo, aplicou-se a modelagem para investigar a farmacocinética desses agentes antimicrobianos nos pacientes queimados. Os parâmetros cinéticos foram estimados com base no modelo aberto de um compartimento pela aplicação do programa PK Solutions v. 2.0; a estatística foi realizada pela utilização do programa GraphPad Prism v. 4.0. Com base na farmacocinética alterada, as concentrações obtidas para a vancomicina e imipenem se mostraram abaixo dos valores recomendados para atingir eficácia; por outro lado, as concentrações obtidas para o cefepime se mostraram dentro da faixa recomendada para atingir eficácia, uma vez que não se registrou alteração da farmacocinética deste antimicrobiano nos pacientes queimados. Desta forma, o monitoramento plasmático terapeutico se mostrou importante, permitindo o ajuste de dose para a vancomicina e para o imipenem, uma vez que a concentração minima efetiva (CME) não foi atingida para ambos pela utilização do regime de dose empírica nos pacientes queimados. Por outro lado, o monitoramento do cefepime plasmático também se mostrou de relevância, uma vez que os pacientes queimados com longa permanência na terapia intensiva podem apresentar disfunção renal em alguma fase da internação; consequentemente, a individualização de dose será recomendada para esses pacientes. Adicionalmente, investigou-se a disposição cinética da vancomicina em nove pacientes queimados após duas diferentes intervenções cirúrgicas. Comparou-se a farmacocinética da vancomicina pós-desbridamento versus pos-enxerto com base no monitoramento plasmático após o regime de dose empírica (1 g, 12/12 h). Após multiplas infusões, o vale da vancomicina plasmática foi obtido pela coleta de sangue imediatamente antes da infusão subsequente e está relacionado ao acúmulo no estado de equilíbrio. Em conseqüência da depuração aumentada e meia-vida biológica reduzida pós-desbridamento comparado ao pós-enxerto, registrou-se para a vancomicina vale abaixo da concentração efetiva mínima nos pacientes queimados. Finalmente, os resultados obtidos no presente estudo permitem concluir que a farmacocinética da vancomicina e do imipenem está alterada nos pacientes queimados com sepse, e recomenda-se o monitoramento das concentrações plasmáticas para garantir a eficácia de forma a previnir a emergência bacteriana. / Sepsis after thermal injury is the major cause of morbidity and mortality in burn patients, once deep changes on the pharmacokinetics of antimicrobials agents are expected. Thirty one burn patients were investigated, all of them had documented sepsis and presented active lesions; they were treated with empirical dose regimen as follows: 1 g, 12/12 h for vancomycin, 1 g, 6/6 h for imipenem and 2 g, 8/8 h for cefepime. A serial of seven blood samples were collected from the venous catheter (2 mL/each); plasma was obtained by centrifugation and storaged in an ultra-low freezer (-80o C) until assay. Drug plasma concentration was determined simultaneously by application of a bioanalytical method described previously. High performance liquid chromatographic method showed good linearity, precision and accuracy for vancomycin, cefepime and imipenem plasma measurements; its application permitted therapeutic drug monitoring and pharmacokinetic studies. Pharmacokinetic modeling was applied to data obtained based on drug plasma concentrations versus time, to investigate those antimicrobial agents in burn patients. Estimated kinetic parameters were based on the one compartment open model by application the software PK Solutions v. 2.0; statistics was performed by using the software GraphPad Prism v. 4.0. Based on altered pharmacokinetics, obtained plasma concentrations to reach drug efficacy were below the recommended values for vancomycin and imipenem; on the other hand, cefepime plasma concentrations to reach drug efficacy were in the recommended range, once its pharmacokinetics didnt change in burn patients. Then, therapeutic plasma monitoring was cost-effective permitting dose adjustment for vancomycin and imipenem, once the minimum effective concentration (MEC) wasnt reached for both antimicrobial agents by using the empirical dose regimen for burn patients. On the other hand, cefepime plasma monitoring was also cost-effective, since burn patients long term therapy can present renal dysfunction at the minimum one period in the intensive care unit; consequently, dose adjustment could be required for them. Additionally, vancomycin kinetic disposition was investigated in nine burn patients after two different surgical interventions. Vancomycin pharmacokinetics post-debridement versus post-skin grafting procedure was compared based on drug plasma monitoring by using the empirical dose regimen (1 g, 12/12 h). Trough vancomycin plasma level after multiple infusions, obtained by blood collection before de next dose, is related to drug accumulation at the steady state level; then, trough below the minimum effective concentration (MEC) were obtained after both surgical procedures performed in burn patients. Meanwhile, increased plasma clearance and reduced biological half-life were obtained after debridement compared skin grafting procedure. Finally, data obtained in the present study permit to conclude that the pharmacokinetics is altered for vancomycin and imipenem in burn patients with sepsis, and drug plasma monitoring is recommended to guarantee drug efficacy and to prevent the bacterial emergency.
4

Monitoramento terapêutico e modelagem farmacocinética de antimicrobianos em pacientes queimados da unidade de terapia intensiva / Therapeutic drug monitoring and pharmacokinetics of antimicrobial agents in burn patients from the Intensive care unit

Karin Jannet Vera López 14 September 2009 (has links)
A sepse após a injúria térmica é a maior causa de morbidade e mortalidade em pacientes queimados, uma vez que profundas alterações ocorrem na farmacocinética de agentes antimicrobianos. Investigaram-se trinta e um pacientes, portadores de sepse documentada e apresentando lesões ativas; utilizou-se o tratamento empírico conforme seguem os regimes de dose: 1 g, 12/12 h para a vancomicina, 1 g, 6/6 h para o imipenem e 2 g, 8/8 h para o cefepime. Sete coletas seriadas de sangue foram realizadas através de cateter venoso (2 mL/cada); o plasma foi obtido pela centrifugação e armazenado no congelador (-80o C) até o ensaio. A concentração plasmática dos antimicrobianos foi determinada simultaneamente pela aplicação do método bioanalítico desenvolvido no estudo. O método de cromatografia líquida de alta eficiência demonstrou boa linearidade, precisão e exatidão para a determinação simultânea da vancomicina, cefepime e imipenem plasmáticos; a plicação desse método bioanalítico permitiu o monitoramento plasmático terapêutico e o estudo farmacocinético. Com base nos resultados obtidos de concentração plasmática versus tempo, aplicou-se a modelagem para investigar a farmacocinética desses agentes antimicrobianos nos pacientes queimados. Os parâmetros cinéticos foram estimados com base no modelo aberto de um compartimento pela aplicação do programa PK Solutions v. 2.0; a estatística foi realizada pela utilização do programa GraphPad Prism v. 4.0. Com base na farmacocinética alterada, as concentrações obtidas para a vancomicina e imipenem se mostraram abaixo dos valores recomendados para atingir eficácia; por outro lado, as concentrações obtidas para o cefepime se mostraram dentro da faixa recomendada para atingir eficácia, uma vez que não se registrou alteração da farmacocinética deste antimicrobiano nos pacientes queimados. Desta forma, o monitoramento plasmático terapeutico se mostrou importante, permitindo o ajuste de dose para a vancomicina e para o imipenem, uma vez que a concentração minima efetiva (CME) não foi atingida para ambos pela utilização do regime de dose empírica nos pacientes queimados. Por outro lado, o monitoramento do cefepime plasmático também se mostrou de relevância, uma vez que os pacientes queimados com longa permanência na terapia intensiva podem apresentar disfunção renal em alguma fase da internação; consequentemente, a individualização de dose será recomendada para esses pacientes. Adicionalmente, investigou-se a disposição cinética da vancomicina em nove pacientes queimados após duas diferentes intervenções cirúrgicas. Comparou-se a farmacocinética da vancomicina pós-desbridamento versus pos-enxerto com base no monitoramento plasmático após o regime de dose empírica (1 g, 12/12 h). Após multiplas infusões, o vale da vancomicina plasmática foi obtido pela coleta de sangue imediatamente antes da infusão subsequente e está relacionado ao acúmulo no estado de equilíbrio. Em conseqüência da depuração aumentada e meia-vida biológica reduzida pós-desbridamento comparado ao pós-enxerto, registrou-se para a vancomicina vale abaixo da concentração efetiva mínima nos pacientes queimados. Finalmente, os resultados obtidos no presente estudo permitem concluir que a farmacocinética da vancomicina e do imipenem está alterada nos pacientes queimados com sepse, e recomenda-se o monitoramento das concentrações plasmáticas para garantir a eficácia de forma a previnir a emergência bacteriana. / Sepsis after thermal injury is the major cause of morbidity and mortality in burn patients, once deep changes on the pharmacokinetics of antimicrobials agents are expected. Thirty one burn patients were investigated, all of them had documented sepsis and presented active lesions; they were treated with empirical dose regimen as follows: 1 g, 12/12 h for vancomycin, 1 g, 6/6 h for imipenem and 2 g, 8/8 h for cefepime. A serial of seven blood samples were collected from the venous catheter (2 mL/each); plasma was obtained by centrifugation and storaged in an ultra-low freezer (-80o C) until assay. Drug plasma concentration was determined simultaneously by application of a bioanalytical method described previously. High performance liquid chromatographic method showed good linearity, precision and accuracy for vancomycin, cefepime and imipenem plasma measurements; its application permitted therapeutic drug monitoring and pharmacokinetic studies. Pharmacokinetic modeling was applied to data obtained based on drug plasma concentrations versus time, to investigate those antimicrobial agents in burn patients. Estimated kinetic parameters were based on the one compartment open model by application the software PK Solutions v. 2.0; statistics was performed by using the software GraphPad Prism v. 4.0. Based on altered pharmacokinetics, obtained plasma concentrations to reach drug efficacy were below the recommended values for vancomycin and imipenem; on the other hand, cefepime plasma concentrations to reach drug efficacy were in the recommended range, once its pharmacokinetics didnt change in burn patients. Then, therapeutic plasma monitoring was cost-effective permitting dose adjustment for vancomycin and imipenem, once the minimum effective concentration (MEC) wasnt reached for both antimicrobial agents by using the empirical dose regimen for burn patients. On the other hand, cefepime plasma monitoring was also cost-effective, since burn patients long term therapy can present renal dysfunction at the minimum one period in the intensive care unit; consequently, dose adjustment could be required for them. Additionally, vancomycin kinetic disposition was investigated in nine burn patients after two different surgical interventions. Vancomycin pharmacokinetics post-debridement versus post-skin grafting procedure was compared based on drug plasma monitoring by using the empirical dose regimen (1 g, 12/12 h). Trough vancomycin plasma level after multiple infusions, obtained by blood collection before de next dose, is related to drug accumulation at the steady state level; then, trough below the minimum effective concentration (MEC) were obtained after both surgical procedures performed in burn patients. Meanwhile, increased plasma clearance and reduced biological half-life were obtained after debridement compared skin grafting procedure. Finally, data obtained in the present study permit to conclude that the pharmacokinetics is altered for vancomycin and imipenem in burn patients with sepsis, and drug plasma monitoring is recommended to guarantee drug efficacy and to prevent the bacterial emergency.

Page generated in 0.0533 seconds