• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
391

Efeito da variação do período do polimento na rugosidade superficial e na manutenção do polimento de diferentes resinas compostas /

Silva, João Maurício Ferraz da. January 2007 (has links)
Orientador: José Roberto Rodrigues / Banca: Eduardo Shigueyuki Uemura / Banca: George Miguel Spyrides / Resumo: O objetivo do estudo foi avaliar o efeito da realização de um polimento imediato, após 24h e após uma semana, na rugosidade superficial de duas resinas microhíbridas (Esthet - X - Dentsply e Opallis - FGM) e uma nanoparticulada (Z 350 - 3M), além de verificar a manutenção do polimento, após 1 ano, simulado por meio de termociclagem. Com auxílio de uma matriz metálica, que apresentava orifícios de 6 mm de diâmetro e 3 mm de altura, 43 cdp de cada material foram confeccionados. Em seguida foram divididos em um grupo controle e 3 grupos experimentais. Os cdp do grupo controle não receberam nenhum tipo de tratamento em suas superfícies. O grupo 1 recebeu acabamento com ponta diamantada extra-fina e posterior polimento com os sistemas Enhance e PoGo (Dentsply), imediatamente após a polimerização. O grupo 2 recebeu os mesmos procedimentos descritos para o grupo 1, porém estes foram realizados após 24 h de armazenamento em H2O destilada a 37°C. O ultimo grupo recebeu o tratamento de superfície após 7 dias de armazenamento. Após os procedimentos de acabamento e polimento os cdp tiveram a rugosidade superficial avaliada por um rugosimetro Perthometer PRK S8P (Perthen, Mahr, Germany). Feita a leitura inicial os cdp foram levadas a uma cicladora térmica e submetidos a 10.000 ciclos simulando permanência em meio oral durante o período de um ano. Após a ciclagem uma nova leitura da rugosidade foi realizada. Os resultados mostraram uma maior rugosidade para a resina Esthet - X, sendo que as resinas Opallis e Z 350 apresentaram os mesmos valores de rugosidade. Em relação ao período de realização do polimento, os cdp polidos imediatamente após a polimerização se apresentaram mais rugosos em relação aos outros dois períodos. Após a ciclagem térmica, a estatística através do teste t-pareado, mostrou que... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of the study was to evaluate the effect of a immediate polishing, after 24h and after one week, in the surface roughness of two micro-hybrid resins (Esthet - X - Dentsply and Opallis - FGM) and one nanoparticle (Z 350 - 3M), beyond verifying the maintenance of the polishing, after 1 year, simulated through thermal cycling. With aid of a metallic matrix, with orifices of 6 mm of diameter and 3 mm of height, 43 specimens of each material had been confectioned. After that they had been divided in a control group and 3 experimental groups. The specimens of the control group had received no treatment in its surfaces. Group 1 received finishing with extra-fine diamond drill and posterior polishing with the systems Enhance and PoGo (Dentsply), immediately after the polymerization. Group 2 received the same procedures described for group 1, however these had been carried out after 24 h of storage in distilled H2O 37°C. The last group received the treatment on the surface after 7 days of storage. After the procedures of finishing and burnishing the surface roughness was evaluated by a profilemeter Perthometer PRK S8P (Perthen, Mahr, Germany). After the initial reading the specimens had been taken to a thermal cycle and submitted to 10000 cycles simulating permanence in mouth on a period of one year. After the thermal cycling a new reading of the roughness was carried out. The results had shown a higher roughness for the resin Esthet - X, having the resins Opallis and Z 350 presented the same values of roughness. In relation to the period of accomplishment of polishing, specimens polished immediately after the polymerization presented higher values of roughness in relation to the other two periods. After the thermal cycling the statistics, through the test t-paired, showed that occurred maintenance of the polishing for the Opallis resin, having... (Complete abstract, click electronic access below) / Mestre
392

Avaliação da biocompatibilidade de quatro agentes para cimentação através do estudo das reações teciduais em conjuntivo da ratos /

Nogueira Junior, Lafayette. January 2001 (has links)
Orientador: José Eduardo Junho de Araújo / Banca: Eduardo Piza Pellizi / Banca: Humberto Gennari Filho / Banca: Marcos Yasunóri Maekawa / Banca: Clovis Pagani / Resumo: A biocompatibilidade de quatro agentes para cimentação de peças protéticas foi avaliada por meio de implantes em tecido conjuntivo subcutâneo de ratos. Neste trabalho foram avaliados um cimento de fosfato de zinco (Lee Smith - Vigodent), um cimento de ionômero de vidro (Ketac-Cem - ESPE) e dois cimentos resinosos (Panavia Ex 21 - Kuraray Co.; Enforce- Dentsply). Após a manipulação dos cimentos, os implantes foram realizados, utilizando-se tubos de polietileno preenchidos com os agentes cimentantes e inseridos em lojas cirúrgicas preparadas no dorso dos animais, os quais foram sacrificados nos períodos de observação de 14, 30, 60 e 84 dias. Os tecidos circunjacentes aos implantes foram removidos, incluídos em parafina e corados com hematoxilina e eosina para análise em microscopia óptica. Os resultados mostraram que todos os agentes de cimentação causaram uma resposta tecidual nos períodos avaliados; o cimento de fosfato de zinco apresentou um menor grau de reação tecidual nos períodos de 14, 30 e 60 dias; o cimento de ionômero de vidro apresentou as piores características de biocompatibilidade quando em contata com o tecido conjuntivo de ratos / Abstract: The biocompatibility of four luting agents was evaluated in rats subcutaneous connective tissue implants. Polyethylene lubes filled with the luting agents were surgically implanted into the dorsal subcutaneous tissue of rats. The tube was left implanted for periods of 14, 30, 60 and 84 days, following wich the animals were killed and the implants, together with the surrounding tissue, were excised. The specimens were then fixed in 10 per cent formalin, sectioned serially and stained with hematoxylin and eosin and then, examined by light microspic . The results showed that all the luting caused an tissue answer in the appraised periods; the phosphate of zinc cement presented a smaller degree of tissue reaction in the periods of 14, 30 and days; the of glass ionomer cement presented the worst characteristics of biocompatibility when in contact with the conjunctive tissue in rats / Doutor
393

Análise do conhecimento dos cirurgiões dentistas sobre plano de tratamento das injúrias do ligamento periodontal após traumatismo dentoalveolar /

Pedrini, Denise. January 2008 (has links)
Resumo: O diagnóstico preciso e a elaboração de um plano de tratamento adequado podem constituir uma tarefa bastante complexa, especialmente nos traumatismos dentoalveolares, pois necessitam de uma abordagem multidisciplinar e conhecimento sobre o processo de reparo após o traumatismo. O objetivo do trabalho foi analisar o conhecimento dos cirurgiões dentistas sobre plano de tratamento das injúrias do ligamento periodontal após traumatismo dentoalveolar. Para tanto, a partir de um questionário, foram abordadas perguntas referentes ao perfil dos profissionais entrevistados e conduta frente às injúrias do ligamento periodontal (concussão, subluxação, luxação extrusiva, luxação lateral e luxação intrusiva) ocasionadas por traumatismo dentoalveolar. Seiscentos e noventa e três cirurgiões dentistas que participaram da 23ª Reunião Anual da SBPqO (2006) responderam o questionário e os dados obtidos foram submetidos à análise descritiva, enquanto o teste estatístico foi aplicado para demonstrar as freqüências e o nível de significância entre as variáveis (Teste qui-quadrado ou Teste Exato de Fisher). De acordo com os resultados obtidos, grandes dificuldades foram encontradas com relação ao plano de tratamento das luxações extrusiva, lateral e intrusiva. De maneira geral, a especialidade não influenciou na elaboração de planos adequados para as injúrias mais complexas. Foi possível concluir que os cirurgiões dentistas não apresentam conhecimento suficiente para tratar de maneira adequada as injúrias mais severas do ligamento periodontal após traumatismo dentoalveolar / Abstract: An accurate diagnosis and the establishment of an adequate treatment plan may constitute quite a complex task, particularly in cases of dentoalveolar trauma, which require a multidisciplinary approach and knowledge of the repair process in tooth injuries. The aim of this study was to analyze the dentists' knowledge of the treatment plan for periodontal ligament injuries after dentoalveolar trauma. For such purpose, a questionnaire was prepared with questions arguing about the profile of the interviewed professionals and their conduct facing periodontal ligament injuries (concussion, subluxation, extrusive luxation, lateral luxation and intrusive luxation) secondary to dentoalveolar trauma. Six hundred and ninety three dentists attending the 23rd Annual Meeting of the SBPqO (2006) filled out the questionnaire and the obtained data were subjected to descriptive analysis. Either chi-square test or Fisher's exact test was applied to determine the frequencies and the significance level among the variables. The results revealed great difficulties in establishing a treatment plan for extrusive, lateral and intrusive luxations. In general, the dental specialty of the participants did not influence the elaboration of adequate treatment plans for the most severe injuries. It could be concluded that dentists do not have sufficient knowledge to treat properly the most severe types of periodontal ligament injuries following a dentoalveolar trauma
394

Avaliação das propriedades físicas, químicas e biológicas do cimento Portland associado á radiopacificadores micro e nanoparticulados /

Silva, Guilherme Ferreira da. January 2013 (has links)
Orientador: Paulo Sergio Cerri / Coorientador: Juliane M. Guerreiro Tanomaru / Banca: Raquel Assed Bezerra da Silva / Banca: Giulio Gavini / Banca: Gisele Faria / Banca: Mário Tanomaru Filho / Resumo: Objetivo: Avaliar as propriedades físicas, químicas e biológicas do cimento Portland (CP) associado a diferentes radiopacificadores (óxido de zircônio - OZr e óxido de nióbio - ONb) micro e nanoparticulados. Metodologia: Para isso, os grupos experimentais foram divididos em: Capítulo 1 - CP, CP+20% de óxido de bismuto (OB), CP+30% OZrmicro e CP+30% OZrnano; Capítulo 2 - CP+30% ONbmicro, CP+30% ONbnano e MTA-Angelus. Todos os materiais foram submetidos aos testes de radiopacidade, tempo de presa, pH e liberação de íons cálcio. Além disso, nos materiais do capítulo 1 foi realizado o teste de resistência à compressão após 24 horas e 21 dias. A reação tecidual provocada pelos materiais foi investigada por meio de análises morfológica, morfométrica (densidade numérica de células inflamatórias, CI) e imuno-histoquímica (número de células imunopositivas à interleucina-6, IL-6) da cápsula formada após 7, 15, 30 e 60 dias de implantação no subcutâneo dorsal. O método von Kossa, para detecção de estruturas calcificadas, também foi realizado. Resultados: Capítulo 1 - Os materiais testados apresentaram pH alcalino e liberação de íons cálcio após 1, 7, 14 e 28 dias. Os materiais CP+OB, CP+OZrmicro e CP+OZrnano apresentaram valores de radiopacidade estatisticamente superiores ao CP e similares entre si. O CP+OZr micro e o CP+OZr nano exibiram tempos de presa maiores do que CP (p≤0,05). O CP apresentou valor de resistência à compressão, após 24 horas e 21 dias, maior do que os materiais, porém, a adição de OZr promoveu médias estatisticamente superiores quando comparado ao CP+OB. Em todos os grupos, verificou-se redução significante no número de CI e de células imunopositivas à IL-6 aos 15, 30 e 60 dias em comparação à 7 dias. O número de CI e de células imunomarcadas à IL-6 nos materiais... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: The aim of this study was to evaluate the effect of different micro e nanoparticulated radiopacifiers (zirconium oxide - ZrO and niobium oxide - NbO) on the physicochemical and biological properties of Portland cement (PC). Methods: The experimental groups were divided in: Chapter 1 - PC, PC+20% bismuth oxide (BO), PC+30% ZrOmicro e PC+30% ZrOnano; Chapter 2 - PC+30% NbOmicro, PC+30% NbOnano and MTA-Angelus. All materials were submitted to the tests of radiopacity, setting time, pH and calcium ion release. Besides, in the materials of chapter 1, the test of compressive strength after 24 hours and 21 days was performed. Moreover, tissue reaction promoted by all materials was evaluated in rat subcutaneous. In each rat, two polyethylene tubes filled with materials were implanted into dorsal subcutaneous. Empty tubes were used as control. After 7, 15, 30 and 60 days, the specimens were fixed and embedded in paraffin. In the HE-stained sections, the number of inflammatory cells (IC) in the capsule was obtained. Moreover, detection of interleukin-6 (IL-6) by immunohistochemistry and number of IL-6 immunolabeled cells were carried out. The von Kossa method was also performed. The differences among the groups were subjected to ANOVA with a significance level of 5%. Results: Chapter 1 - All materials presented an alkaline pH and released calcium ions after 1, 7, 14 and 28 days. The PC+BO, PC+ZrOmicro and PC+ZrOnano exhibited radiopacity values statistically superior than PC. The PC+ZrOmicro and PC+ZrOnano presented setting times higher than PC (p≤0.05). After 24 hours and 21 days, the PC showed compressive strength value significantly superior to the other materials. A higher compressive strength in the PC+ZrO (micro and nano) was found compared to PC+BO. In all groups, significant reduction in... (Complete abstract click electronic access below) / Doutor
395

Usinabilidade e integridade superficial de implantes dentários /

Manera, Rodolfo da Silva. January 2014 (has links)
Orientador: Alessandro Roger Rodrigues / Banca: Hidekasu Matsumoto / Banca: Marcos Valerio Ribeiro / Resumo: Ligas metálicas destinadas a implantes, de um modo geral, têm sido cada vez mais pesquisadas quanto às suas propriedades mecânicas, microestruturais e características de biocompatibilidade. Apesar do surgimento de inúmeros materiais poliméricos, o titânio e suas ligas representam ainda a grande gama de aplicações na área da implantodontia. O titânio é considerado um material de difícil usinabilidade, pois desenvolve altas tensões e temperaturas em uma área de corte 2/3 menor que a de outros materiais. Assim, os parâmetros de usinagem e a ferramenta de corte necessitam ser adequadamente especificados, pois tanto a matéria-prima quanto o processo de fabricação levam a um alto valor agregado do produto final. Este trabalho determinou os efeitos da velocidade de corte e da profundidade de usinagem na usinabilidade (força de corte e energia específica de corte) e integridade superficial (microdureza e acabamento) no roscamento de implantes dentários de titânio comercialmente puro (grau 4, ASTM F67). Os ensaios foram realizados em torno CNC de cabeçote móvel, empregando ferramenta de metal duro revestida de TiAlN e fluido de corte abundante. Com base na Análise de Variância (ANOVA), os resultados mostraram que os parâmetros de corte afetam a usinabilidade e a integridade superficial da rosca, sendo a profundidade de usinagem o fator mais influente. Níveis muito baixos ou altos da profundidade de usinagem elevam a energia específica e a força de corte, respectivamente, encruando a subsuperfície da rosca e prejudicando a rugosidade dos flancos dos filetes. Velocidades de corte menores tendem a aumentar a força e a energia específica de corte, prejudicando o acabamento da rosca, mas não influem em sua dureza. Rugosidades estatísticas "Skewness" e "Kurtosis" apontaram a prevalência de picos agudos na superfície da rosca, favorecendo a osseointegração. Testes na condição High-Speed Cutting (HSC) indicaram ... / Abstract: Metallic alloys applied to implants have been researched aiming at improving their mechanical properties, microstructure and biocompatibility. Despite appearing several types of polymers in the last years, titanium and its alloys are still used extensively in the implantology. Titanium is considered a hard-to-cut material, because it develops high stresses and temperatures in a small cutting area (2/3 smaller than for other materials). Thus cutting parameters and tools need to be specified properly, since both raw material and manufacturing process increase the costs of the final product. This research determined the effects of cutting speed and depth of cut on machinability (cutting force and specific cutting energy) and surface integrity (microhardness and roughness) when threading pure commercially dental implants (grade 4, ASTM F67). Machining tests were carried out in a CNC lathe by applying TiAlN coated carbides and cutting fluid. Based on Analysis of Variance (ANOVA), the main results indicated that cutting parameters influence on machinability and surface integrity of the implant screw, being depth of cut the more influent. Low and high levels of depth of cut increase specific cutting energy and cutting force, respectively, hardening the screw subsurface and damaging the roughness of the thread flanks. Lower cutting speeds trend to raise both cutting force and specific cutting energy, damaging the screw finishing, but they do not affect its subsurface microhardness. Skewness and Kurtosis roughness parameters indicated the predominance of spiky surface on screw which is favorable to osseointegration. Tests at High-Speed Cutting (HSC) showed it is possible to machine implant screws, but depth of cut cannot be high so that avoiding vibration in threads / Mestre
396

Colonização bacteriana na região marginal de restaurações cerâmicas: efeito do método de remoção do cimento e do polimento /

Pereira, Sarina Maciel Braga. January 2015 (has links)
Orientador: Luiz Felipe Valandro / Banca: Renata Marques de Melo Marinho / Banca: Antonio Olavo Cardoso Jorge / Banca: Marina Amaral / Banca: Rodrigo Othavio de Assuncão e Souza / Resumo: O presente estudo teve como objetivo avaliar o efeito de diferentes métodos de remoção do excesso de cimento e do polimento na formação de biofilme e micromorfologia na região de margem dente/restauração. A partir de dentes bovinos, foram obtidos 96 blocos de dentina (4 mm x 8 mm x 2 mm) que foram moldados e reproduzidos em gesso tipo IV, sobre os quais foram produzidos 96 blocos prensados de cerâmica (Vita PM9, Vita Zahnfabrik; 4 mm x 8 mm x 2 mm) pela técnica de cera perdida. Os blocos de dentina e seus respectivos blocos cerâmicos foram cimentados com um cimento resinoso auto-adesivo (RelyX U200, 3M ESPE) e o excesso de cimento foi removido utilizando diferentes técnicas: MBr: microbrush e fotoativação, MBr-Pol: microbrush, fotoativação e polimento, Pi: pincel e fotoativação, Pi-Pol: pincel, fotoativação e polimento, Foto- Expl: 5 s de fotoativação inicial, explorador e fotoativação final, Foto-Expl- Pol: 5 s de fotoativação inicial, explorador, fotoativação final e polimento, Foto-Bi: 5 s de fotoativação inicial, bisturi e fotoativação final, Foto-Bi-Pol: 5s de fotoativação inicial, bisturi, fotoativação final e polimento. Após 24 h, a rugosidade da região de margem das amostras foi analisada utilizando um rugosímetro (Mitutoyo SJ-400 Tóquio, Japão; três medições em cada amostra). Análise micromorfológica da região foi obtida por microscópio estereoscópico e MEV. Em seguida, as amostras foram contaminadas em caldo de sacarose com suspensão padronizada com Streptococcus mutans, Staphylococcus aureus e Candida albicans e incubados por um período de 48 h. As amostras foram analisadas quantitativamente para aderência bacteriana na região da margem por microscopia de varredura confocal a laser e contagem das unidades formadoras de colônias (UFC/mL), e analisadas qualitativamente usando MEV. Os dados de rugosidade superficial (Ra) foram submetidos à análise de variância (2- way), teste de Tukey.. / Abstract This study evaluated the effects of excess cement removal techniques, with or without posterior polishing, on the biofilm formation and micromorphology in the marginal region of the tooth/restoration. From bovine teeth, 96 dentin blocks (4 x 8 x 2 mm) were produced, molded and reproduced in type IV gypsum, on which 96 pressed ceramic blocks (Vita PM9 4 mm x 8 mm x 2 mm, Vita Zahnfabrik) were produces via lost wax technique. The dentin blocks and their respective ceramic blocks were cemented with a self-adhesive resin-cement (RelyX U200, 3M ESPE) and cement excess was removed using different techniques, followed by polishing with silicone tips or, in some cases, not polished at all: MBr: microbrush and photoactivation, MBr-Pol: MBr + polishing, Pi: brush and photoactivation, Pi-Pol: PI + polishing, Photo-Expl: 5 s initial photoactivation, explorer and final curing, Photo-Expl-Pol: Photo-Expl + polishing, Photo-Bi: 5 s initial photoactivation, scalpel and final curing, Photo-Bi-Pol: Photo-Bi + polishing. After 24 hours, the samples marginal region roughness was analyzed using a profilometer (Mitutoyo SJ-400 Tokyo, Japan; three measurements on each sample). Micromorphological analyses of the region were performed by stereoscopic microscope and SEM. Then the samples were contaminated with sucrose broth standardized suspension with Streptococcus mutans, Staphylococcus aureus and Candida albicans and incubated for a period of 48 hours. The samples were quantitatively analyzed for bacterial adherence in the marginal region by confocal laser scanning microscopy and counting of colony forming units (CFU/ml), and qualitatively analyzed using SEM. Roughness data (Ra) were submitted to 2-way ANOVA, Tukey test (5%) and Student's-t tests. CFU, Biomass and bio thickness data were analyzed by Kruskal Wallis', Mann-Whitney's e Dunn's tests. The removing technique statistically influenced the roughness (Ra; p ˂ 0.05), when comparing polished and unpolished... / Doutor
397

Retorque de parafusos de pilares protéticos com recobrimento de carbono tipo diamante: uma análise da manutenção do torque após fadiga mecânica /

Canavezi, Rafaela Cristiane. January 2015 (has links)
Orientador: Lafayette Nogueira Júnior / Banca: Tarcísio José Arruda de Paes Junior / Banca: Argemiro Soares da Silva Sobrinho / Resumo: Esta pesquisa se propôs verificar a manutenção do torque, após fadiga mecânica, de parafusos de pilares protéticos com recobrimento de carbono tipo diamante (DLC) e com dopagem de diamantes (CD-DLC) submetidos ao retorque, em conexões hexagonais externa (HE) e interna (HI). Implantes HE e HI e diferentes tratamentos do parafuso protético foram alocados em grupos experimentais (n = 5): sem tratamento e não submetidos a fadiga (HE-CON) (HI-CON); sem tratamento fadigados (HECONF) (HI-CONF); com DLC fadigado (HE-DLCF) (HI-DLCF) e com CDDLC fadigados (HE-CD-DLCF) (HI-CD-DLCF). Os recobrimentos de DLC e CD-DLC foram depositados a plasma pelo método PECVD. As amostras (implante + parafusos + coroa metálica), que já haviam sido expostas a 1 milhão de ciclos de fadiga, foram retorqueadas com torquímetro digital, com o torque recomendado pelo fabricante 30 N (HE) e 20 N (HI), e submetidos novamente a 1 milhão de ciclos mecânicos. Ao término da fadiga, os parafusos foram destorqueados para verificar a manutenção do torque. Parafusos de cada grupo experimental foram selecionados para observação em MEV. A análise estatística foi realizada pelo teste Anova 2- Fatores (α = 0,05). Não houve interação entre os fatores em estudo (p = 0,765); o tratamento dos parafusos (p = 0,638) e o tipo de conexão (p = 0,615) não apresentaram diferença estatística. Alterações como danos nas roscas do parafuso e remoção do filme foram observados entre os grupos experimentais. Os grupos com revestimento apresentaram pouco ou nenhum dano nas roscas dos parafusos. O revestimento de DLC e CDDLC parece não ter interferido na adaptação do parafuso ao implante. Parafusos protéticos recobertos com DLC e CD-DLC, após o retorque, não elevaram a manutenção do torque / Abstract: The study analyzed the torque maintain of the screw abutments, with coating of diamond-like carbon (DLC) and doping of diamond (CD-DLC), submitted the retorque in external hexagonal (EH) and internal (IH) connections; after mechanical fatigue. HE and HI implants and different treatments of the abutments screws were divided into experimental groups (n = 5): untreated and not subjected to fatigue (EH-CON) (IHICON); fatigued untreatment (EH-CONF) (IH-CONF); fatigued with DLC (EH- DLCF) (IH-DLCF) and fatigued with CD-DLC (EH-CD-DLCF) (IH-CD-DLCF). The DLC and CD-DLC coating was deposited by plasma, PECVD method. Samples (Implant + abutment screew + metal crown), which had been exposed to 1 million fatigue cycles were retorquiadas, digital torque wrench, to the torque recommended by the manufacturer 30 N (HE) and 20 N (HI), and submitted again to 1 million cycles mechanics. At the end of fatigue, the screws were destorquiados to check the maintenance of torque. Screws from each experimental group were selected for observation by SEM. Statistical analysis was performed by ANOVA 2 Factors test (α = 0.05). There was no interaction among the factors studied (p = 0.765); the treatment of screws (p = 0.638) and the connection type (p = 0.615) showed no statistical difference. The microscopy images showed damage the threads and covering the presence of HI connections. Changes such as damage on the screws threads and film removal were observed among the experimental groups. The coating groups showed little or no damage on the screws threads. The DLC and CD-DLC coating did not interfere in the screw adaptation on the implant. Abutments screew coating with DLC and CD-DLC, after retorque, no raised torque maintenance / Mestre
398

Desenvolvimento de um dispositivo para avaliação dimensional de um processo de fabrico de implantes dentários

Carvalho, João Diogo Cardoso de January 2013 (has links)
Trabalho realizado na empresa BringConcept, orientado pelo Prof. Dr. Casimiro de Andrade / Tese de Mestrado Integrado. Engenharia Metalúrgica e de Materiais. Faculdade de Engenharia. Universidade do Porto. 2013
399

Adesão bacteriana e formação de biofilme em materiais para implantes dentários /

Avila, Erica Dorigatti de. January 2015 (has links)
Orientador: Francisco de Assis Mollo Junior / Co-orientador: Carlos Eduardo Vergani / Banca: Ana Claudia Pavarina / Banca: Gelson Luis Adabo / Banca: Cassio do Nascimento / Resumo: O sucesso clínico da terapia com implantes depende da osseointegração primária e da ausência de inflamação no tecido peri-implantar. Um importante fator contribuinte para o desenvolvimento da inflamação é a colonização de microrganismos e subsequente formação de biofilme tanto nos materiais para implante quanto para componentes protéticos. Neste estudo, nós focamos no efeito de um tratamento de superfície para implante de titânio (Ti) e em materiais para abutments na adesão de bactérias e formação de biofilme. O tratamento em questão, consiste na conversão das propriedades hidrofóbicas do Ti para hidrofílicas por meio da foto funcionalização da luz UV. Biofilme foi desenvolvido pela incubação dos discos com e sem tratamento, em rico meio de cultura contendo uma complexa comunidade oral representativa da saliva humana. A biomassa e o perfil das bactérias aderidas em ambas as superfícies foram analisadas após 3 e 16 horas. Para os demais experimentos, foram utilizados discos de Ti e zircônia (ZrO2) simulando as superfícies dos abutments de implantes e esmalte bovino (EB) como controle positivo. Biofilmes simples, com Streptococcus mutans (S. mutans), Porphyromonas gingivalis (P. gingivalis) e Fusobacterium nucleatum (F. nucleatum), e em multiespécie (P. gingivalis e F. nucleatum) foram desenvolvidos sobre as amostras e os resultados foram analisados quantitativamente e qualitativamente. O perfil das bactérias, também, foi analisado por meio do método de eletroforese em gel com gradiente desnaturante (DGGE). Em relação ao primeiro trabalho, embora o perfil das bactérias aderidas apresentou similaridade após 16 horas de incubação, a biomassa do biofilme formado sobre as superfícies de Ti tratado com a luz UV, foi significativamente menor. Ti e ZrO2 apresentaram fortes características hidrofóbicas enquanto o EB... ((Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Dental implant rehabilitation has become a routine procedure to replace missing teeth. Its success depends on proper osseointegration, as well as the lack of inflammation. An important factor contributing to the development of inflammation is the attachment of microorganisms and subsequent development of biofilms on the prosthetic components. This study focused on effect of materials and treatment surfaces on the bacterial adhesion and biofilm formation. We, first, assessed the biofilm formation on machined titanium (Ti) discs treated and untreated with UV photofunctionalization. UV-treatment was performed using a photo-device for 12 minutes. Hydrophobic-to-hydrophilic conversion was confirmed on UV-treated titanium surfaces. Biofilm was formed by incubating the discs in rich medium containing a complex representative saliva-derived oral microbial community. After 3 and 16 hours, the biomass of biofilm and the bacteria profile was analyzed. For other experiments, it was used titanium and zirconia (ZrO2) discs as abutment implants and bovine enamel (BE) as a positive control. Roughness means that topography and energy-free surface analysis were performed prior to applying microbiology biofilms onto materials. Biofilms in single species with Streptococcus mutans (S. mutans), Porphyromonas gingivalis (P. gingivalis) and Fusobacterium nucleatum (F. nucleatum) and multi species with P. gingivalis and F. nucleatum were developed on each samples and quantitatively evaluated by counting forming units (CFU) and qualitatively by confocal microscopy. Also, we analyzed the development of a complex oral biofilm on two different abutments implants surfaces. Quantitatively and qualitatively analysis were performed after 16 and 48 hours of incubation under anaerobic conditions. In relation to first study, the biomass of biofilm formed on UV treated surfaces was significantly... (Complete abstract electronic access below)
400

Efeito do recobrimento de filmes de carbono tipo diamante depositados a plasma na manutenção do torque de parafusos protéticos /

Lepesqueur, Laura Soares Souto. January 2014 (has links)
Orientador: Lafayette Nogueira Júnior / Co-orientador: Marcos Massi / Banca: Tarcisio José de Arruda Paes Junior / Banca: Luís Guilherme Scavone de Macedo / Resumo: Objetivo: Avaliar os valores de torque reverso RT(%) de parafusos protéticos de liga de titânio recobertos com um filme de carbono amorfo tipo diamante (DLC) e filme dopado com partículas de diamante(CD-DLC) comparando-os com parafusos sem tratamento (controle). Método: Foram utilizados 60 implantes de plataforma regular, divididos de acordo com o tipo de conexão (hexágono externo e hexágono interno) e o tratamento do parafuso protético (n=10): Grupo A1: hexágono externo/parafuso controle; Grupo A2: hexágono externo/parafuso com DLC; Grupo A3: hexágono externo/parafuso com CD-DLC; Grupo B1: hexágono interno/parafuso controle; Grupo B2: hexágono interno/parafuso com DLC; Grupo B3: hexágono interno/parafuso com CD-DLC. Os filmes de DLC e CD-DLC foram depositados pelo processo conhecido como PECVD (Plasma Enhanced Chemical Vapour Deposition). Os implantes foram inseridos em blocos de poliuretano e as coroas protéticas cimentadas sobre os pilares que foram parafusados aos implantes. O torque reverso foi mensurado após ciclagem mecânica (1.106 ciclos). A análise estatística foi realizada pelo teste Anova 1 fator e Teste de Tukey e Teste t-student com nível de significância de 5%. Resultados: A análise dos resultados mostraram que após a ciclagem mecânica o torque reverso RT(%) do grupo sem tratamento (A1) foi significativamente maior que a dos grupos DLC (A2) e CD-DLC (A3) (p=0,0001), para os parafusos das conexões HE. Entretanto não houve diferença estatística entre os grupos com e sem tratamento na manutenção do torque para os parafusos dos grupos de conexão HI (p= 0.5476). Conclusão: Nas condições estudadas, concluiu-se que os parafusos revestidos com filmes DLC não foram efetivos na manutenção do torque reverso em relação aos parafusos sem tratamento para ambas... / Abstract: Objective: To evaluate the values of reverse torque RT ( % ) of prosthetic screws titanium alloy coated with a film of diamond-like carbon (DLC) and DLC film doped with diamond particles (CD- DLC) comparing them with screws without treatment (control). Method: Sixty implants were divided into six groups according to the type of connection (external or internal hex) and type of abutment screw (n = 10 ): Group A1: external hexagon / screw control, Group A2: external hexagon / screw with DLC; group A3: external hexagon / screw with CD- DLC; group B1: internal hex / screw control; group B2: internal hex / screw with DLC; group B3: internal hex / screw with CD- DLC. The DLC films and CD - DLC were deposited by PECVD process (Plasma Enhanced Chemical Vapour Deposition). The implants were inserted into polyurethane resin, and crowns of nickel chrome cast were cimented and the abutments screwed into the implants. The reverse torque was measured after the mechanical cycling (1.106 cycles). Statistical analysis was performed by one factor ANOVA and Tukey's test, with significance level of 5%. Analysis was performed screws through scanning electron microscopy (SEM) before and after loading . Results: The results showed that after mechanical reverse torque RT (%) for the untreated group (A1) was significantly higher than the one of the DLC groups (A2) and CD -DLC (A3) (p = 0.0001). However, there was no statistical difference for the groups with and without coating in maintaining torque for the screws' internal hex connections (p = 0.5476). Conclusion: After mechanical cycling, the diamond-like carbon with and without doping of diamond on the screws for abutments, showed no improvement in maintaining the torque in external and internal hex connections... (Complete abstract click electronic access below) / Mestre

Page generated in 0.1024 seconds