• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

Efeito de três sistemas de osteotomia - ultrassom cirúrgico, laser Er, Cr: YSGG e sistema rotatório - sobre o processo de osseointegração e reparo de defeitos ósseos em tíbia de ratos : estudo histomorfométrico, imuno-histoquímico e biomecânico /

Esteves, Jônatas Caldeira. January 2014 (has links)
Orientador: Elcio Marcantonio Junior / Banca: Roberto Henrique Barbeiro / Banca: Wilson Roberto Poi / Banca: Thalita Pereira Queiroz / Banca: Paulo Tambasco de Oliveira / Resumo: O objetivo deste trabalho foi avaliar o processo de reparo ósseo e a osseointegração de implantes inseridos em leitos cirúrgicos preparados por meio de Brocas Convencionais, Ultrassom Piezoelétrico e LASER Er,Cr:YSGG. Como objetivo secundário, foi testada a habilidade do ultrassom cirúrgico de estumilar a liberação de citocinas e fatores de crescimento ósseo durante o processo de reparo. Para tanto, dois estudos distintos foram conduzidos. No Estudo 1, 144 ratos foram divididos em 3 grupos (Grupos Broca, LASER e Piezo) com 48 animais cada. Mini implantes usinados foram instalados em ambas as tíbias de cada animal em alvéolos cirúrgicos preparados pelos 3 sistemas testados de acordo com o grupo ao qual o animal pertencia Após a intervenção cirúrgica, 8 animais por grupo foram sacrificados aos 0, 3, 7, 14, 30 e 60 dias pós-operatórios.. O implante da tíbia direita foi utilizado para o ensaio de torque de remoção e o da tíbia esquerda, para análise de Contato-Osso-Implante (COI) e Fração de Área Ocupada por Osso (FAOO). No Estudo 2, 174 animais foram divididos nos mesmos grupos experimentais - Broca, Piezo e Laser - com 63, 63 e 48 animais cada, respectivamente. Defeitos ósseos de 2mm de diâmetro foram produzidos na tíbia direita dos animais usando um dos três dispositivos testados de acordo com o grupo ao qual o animal foi designado. Oito animais de cada grupo foram sacrificados aos 0, 3, 7, 14 30 e 60 dias e a cicatrização óssea foi analisada por histomorfometria e detecção imuno-histoquímica de Osteocalcina, Osteoprotegerina, Rankl, Vegf e Caspase-3. Cinco animais dos Grupos Broca e Piezo foram sacrificados aos 3, 7 e 14 dias e o espécimes coletados foram utilizados para análise de PCR quantitativo (Q-PCR). Os resultados do Estudo 1 demonstraram a osseointegração dos implantes no três grupos estudados. No Grupo Broca a formação óssea ocorreu mais precocemente, porém um aumento significativo no... / Abstract: The aim of this study was to evaluate the bone healing process and osseointegration of implants placed in sockets prepared by conventional Drills, Piezosurgery and Er,Cr:YSGG laser. As a secondary objective we tested the hability of Piezosurgery of enhancing the bone repair by releasing of citokynes and growth factor. Therefore, two different studies were conducted. In study 1, 144 rats were assigned to 3 groups: Groups Drill, Laser and Piezo, with 48 animals in each group. Machined mini-implants were placed in both tibiae of each animal in sockets prepared by the three tested systems, according to the group in which it was assigned. After the surgical procedures, 8 animals were sacrificed postoperatively at 0, 3, 7, 14, 30 and 60 days in each group. The implant of the right tibia was used for removal torque test and the left tibia implant was used for Bone-to-Implant Contact (BIC) and Bone Area Fraction Occupancy (BAFO) analysis. In Study 2, 174 animals were ssigned to the same experimental Goups - Drill, Piezo and Laser - with 63, 63 and 48 animals in each group. Bone defects with 2mm in diameter were created in the righ tibia of each animal using one of the three tested devices according to the group in which it was assigned. Eight animals of each group was sacrificed at 0, 3, 7, 14 , 30 and 60 days and bone healing were analyzed by means of histomorphometry and immunohistochemical detection of Osteocalcin, Osteoprotegerin, Rankl, Vegf and Caspase-3. Also, 5 animals form Gorups Drill and Piezo were sacrificed at 3, 7 and 14 days and the bone samples were used for quantitative PCR (Q-PCR) analysis. Results of Study 1 demonstrated implant osseointegration in all experimental groups. The Group Drill presented early bone formation, however, significant increasing in torque removal values occurred only at 30 days. In Groups Laser and Piezo, removal torque increased early and bone healing around the implant was progressively increased until... / Doutor
292

Alteração volumétrica por análise microtomográfica, solubilidade e capacidade seladora bacteriana de diferentes materiais retro-obturadores /

Espir, Camila Galletti. January 2014 (has links)
Orientador: Fábio Luiz Camargo Villela Berbert / Co-orientador: Juliane Maria Guerreiro Tanomaru / Banca: Mario Tanomaru Filho / Banca: Fernando Simões Crisci / Resumo: O objetivo deste estudo foi avaliar os materiais retro-obturadores MTA, Cimento Portland associado a 30% de óxido de zircônio (CP/ZrO2) e óxido de zinco e eugenol (OZE). Para análise microtomográfica da alteração volumétrica, cavidades retrógradas foram confeccionadas em dentina bovina e preenchidas com os materiais experimentais, sendo analisados pelo microtomógrafo Sky Scan 1176. A avaliação de solubilidade foi realizada de acordo com normas ISO 6876, por meio da diferença de massa inicial e após 7 dias de imersão em água destilada. A análise da capacidade seladora bacteriana foi realizada em dentes humanos extraídos. Cavidades retrógradas confeccionadas foram preenchidas de acordo com os materiais experimentais (n=12), além do controle positivo (n=8), sem preenchimento, e controle negativo (n=8), com impermeabilização em toda extensão. As amostras foram submetidas à infiltração utilizando cepas de Enteroccocus faecalis (ATCC 29212) em meio de cultura BHI, sendo observadas diariamente por 60 dias e a infiltração avaliada pela turbidez do meio. Os dados foram submetidos aos testes ANOVA e Tukey para solubilidade e alteração volumétrica, e Kruskall-Wallis e Dunn para capacidade seladora bacteriana. Na análise de solubilidade, não houve diferença estatística significante entre os grupos. A análise volumétrica demonstrou maior diminuição de volume para o OZE. Também foi observada maior infiltração bacteriana para o OZE. Conclui-se que MTA e CP/ZrO2 apresentam maior capacidade seladora bacteriana, que pode estar relacionada à menor alteração volumétrica. / Abstract: The present study evaluated different properties of the root end sealers MTA, Portland cement with de 30% zirconium oxide (PC/ZrO2) and zinc oxide and eugenol (ZOE). To analyze the volumetric changes by computed microtomography, bovine teeth were used in which the prepared cavities in dentine were filled according to the materials and then analyzed by Sky Scan 1176. The solubility evaluation was in accordance with ISO 6876 standards, from the difference of the original mass and after 7 days of immersion in distilled water. For analysis of bacterial sealing capacity, extracted human teeth were used. Retrograde cavities were filled according with experimental materials (n=12), besides a positive control (n = 8), no fill, and a negative control (n = 8), with waterproofing to the fullest extent. The samples were subjected to infiltration using Enteroccocus faecalis strains (ATCC 29212) in BHI culture, and observed daily for 60 days and infiltration evaluated by turbidity of the medium. Data were submitted to ANOVA and Tukey tests for solubility and volumetric change, and Kruskall-Wallis and Dunn for bacterial infiltration. In the analysis of solubility, no statistically significant difference between groups. In the analysis of solubility, no statistically significant difference between groups. Volumetric analysis showed greater volumetric reduction for ZOE, as well as greater bacterial infiltration. It was concluded that MTA and CP/ZrO2 have larger bacterial sealing ability, which may be related to lower volumetric changes observed. / Mestre
293

Physicochemical and mechanical properties, bioactivity potential and characterization of the dentin-sealer interface of experimental root sealers based on portland cement with micro and nano particulate radiopacifiers = Propriedades físico-químicas e mecânicas, potencial bioativo e caracterização da interface dentina-cimento de cimentos endodônticos experimentais à base de cimento Portland associados à radiopacificadores micro e nanoparticulados /

Viapiana, Raqueli. January 2014 (has links)
Orientador: Mário Tanomaru Filho / Banca: José Mauricio dos Santos Nunes Reis / Banca: Josette Camilleri / Banca: Marcos Húngaro Duarte / Banca: Loise Pedrosa Salles / Resumo: O cimento Portland é constituído por silicato de cálcio e a associação com aditivos e veículos conferem características que podem viabilizar seu uso como cimento endodôntico. No entanto, o cimento Portland não apresenta radiopacidade própria, o que torna necessário a adição de um agente radiopacificador à mistura para ser utilizado como material dentário. O objetivo deste estudo foi avaliar as propriedades físico-químicas e mecânicas, o potencial bioativo e caracterizar a interface dentina-cimento de cimentos endodônticos experimentas à base de cimento Portland (ES) contendo nano ou micro partículas de óxido de zircônio ou óxido de nióbio. O tempo de presa, resistência à compressão, escoamento, espessura de filme, radiopacidade, solubilidade e estabilidade dimensional foram avaliadas de acordo com a norma ISO 6876:2012, enquanto que a liberação de fomaldeído foi avaliada por meio de cromatografia gasosa. A resistência de união dentinária foi avaliada por meio de teste push-out e tanto a caracterização da microestrutura dos cimento quanto a análise do potencial bioativo foram realizadas utilizando energia dispersiva de raios-x, difractometria e espectroscopia infravermelha. A interface dentina-cimento foi avaliada com relação à penetração de microesferas fluorescentes e examinada em microscopia confocal e microscopia eletrônica de varredura associada à escaneamento por energia dispersiva de raios-x linear. Os dados foram submetidos aos testes ANOVA e Tukey (p < 0,05). Com exceção da radiopacidade, os ES apresentaram propriedades físico-químicas de acordo com as especificações ISO 6876, adequada resistência de união à dentina, potencial bioativo e promoveram selamento coronário e interação química com a dentina. / Abstract: Portland Cement is composed by calcium silicate and the association with additives or vehicles, may confer characteristics to enable the use of this cement as root canal sealer. However, Portland cement lacks in radiopacity which requires the addition of a radiopacifying agent to the mixture to be used as dental material. The purpose of this study was to assess the physicochemical and mechanical properties, the bioactivy potential and to characterize the dentin-sealers interfaces of Portland-based experimental root canal sealers (ES) containing nano or micro particles of zirconium oxide or niobium oxide. Setting time, compressive strength, flow ability, film thickness, radiopacity, solubility and dimensional stability were evaluated according to ISO 6876:2012 standards, whereas formaldehyde realease was investigated using gas-cromatography. Dentin bond strength was evaluated by push-out test and the sealer's microestruture and bioactivity potential were perfomed using X-ray energy espectroscopy, X-ray diffractometry and infrared spectroscopy. Dentin-sealers interface was assessed with respect to fluorescent microspheres penetration and it was also examined using confocal microscope and scanning electron microscope coupled to X-ray energy dispersive line scans. Data were analyzed by ANOVA and Tukey post-hoc test (p < 0.05). With the exception of radiopacity, ES showed physicochemical properties according to ISO 6876:2012 specifications, adequate dentin bond strength, great bioactivity potential and promoted coronal sealing and chemical interaction with dentin. / Doutor
294

Reparo apical e periapical em dentes de cães pós tratamento endodôntico em função do curativo de demora e de um novo cimento obturador. Importância do curativo de demora e do cimento obturador na infiltração apical "in vitro" /

Silveira, Frank Ferreira. January 2000 (has links)
Resumo: O objetivo do presente trabalho foi avaliar um novo cimento obturador de canal radicular denominado comercialmente de Sealer Plus, de acordo com as seguintes metodologias. 1. Avaliação histológica em dentes de cães, após período experimental de 90 dias. Foram utilizados 60 canais radiculares de pré-molares de cães com vitalidade, os quais, após preparo biomecânico, foram obturados pela técnica clássica complementada pela condensação lateral utilizando o cimento Sealer Plus, sendo que no Grupo I os canais radiculares receberam um curativo de demora à base de hidróxido de cálcio por 7 dias, no Grupo II um curativo à base da associação corticosteróide-antibiótico pelo mesmo período e no Grupo III não foi empregado o curativo de demora. Decorridos 90 dias da obturação, os animais foram sacrificados por sobredose anestésica, as maxilas e mandíbulas foram removidas e fixadas em formol a 10%, durante 48 horas. Após o processamento histológico de rotina, os cortes foram corados pela hematoxilina e eosina e pelo tricrômico de Mallory. A análise histopatológica evidenciou que o cimento Sealer Plus quanto à compatibilidade tecidual mostrou-se insatisfatório independente da utilização ou não do curativo de demora. 2. Avaliação da infiltração marginal apical in vitro. Foram utilizados 120 incisivos centrais superiores de humanos extraídos e divididos em quatro grupos de 20 dentes cada, e 3 grupos de 10 dentes usados como controle, os quais foram inicialmente instrumentados com limas tipo K até o no 30 no comprimento real do dente... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The scope of this work was to evaluate a new root canal filling Sealer Plus by using the following methods: 1. Histological evaluation of dog teeth. Experimental period of 90 days. In this experiment, 60 premolar with pulp vitality were used and after biomechanical preparation were filled by classic technique using Sealer Plus completed by lateral condensation; in Group I the root canals were filled with calcium hydroxide intracanal dressing during seven days, in Group II antibiotic/corticosteroid dressing during the same period and Group III without intracanal dressing, After a 90- day period, the animals were sacrificed by anesthethic overdose and had their maxillaries and mandibles removed. The removed parts were fixed in 10% formalin for 48 hours. Following a routine histological process, the cuts were stained by hematoxilin, eosin and Mallory Tricromic. The histopathological analysis showed that the Sealer Plus cement were unsatisfactory in relation to the tissue compatibility. 2. Evaluation of the marginal apical infiltration. In this experiment, 120 extracted top-central human incisors in 4 groups of 20 teeth were used and 3 group of 10 teeth used as control groups. The teeth were initially filed with K file up to the number 30 until apical patency and root canal prepared up to the number 50, using sodium hipochloride 0,5%, After that, the root canal were filled with Sealer Plus or Grossman cements, using or no calcium hydroxide intracanal dressing. After the fillings, the teeth were unpermeated in al their extension with nail polishing, except for 1 to 2 mm around the apical forame, submerged in 2% metilen blue colouring under vacuum conditions and fractured in such a way to obtain 2 sections. The colouring penetration was measured by a perilometer and the data, after statistical analysis, there was no difference between the groups. / Orientador: Léa Assed Bezerra da Silva / Coorientador: Mario Roberto Leonardo / Banca: Mário Tanomaru Filho / Banca: Francisco José de Souza Filho / Banca: Manoel Eduardo de Lima Machado / Doutor
295

Avaliação da atividade antimicrobiana de um reembasador resiliente combinado a um polímero antimicrobiano sobre a formação de bio-filme /

Toda, Carina. January 2013 (has links)
Orientador: Marco antonio Compagnoni / Banca: Ana Maria Pero / Banca: Janaína Habib Jorge / Banca: Maria Fulgência Costa Lima Bandeira / banca Juliê Marra / Resumo: Este estudo avaliou a atividade antimicrobiana de um reembasador resiliente Coe Soft® (RRCS) combinado ao polímero antimicrobiano poli (2 tert-butilaminoetil) metacrilato (PTBAEMA) sobre formação de biofilme de Staphyloccocus aureus, Streptococcus mutans e Candida albicans. Espécimes circulares (15mm x 3mm) do RRCS foram confeccionados (n=27), esterilizados, divididos em três grupos de acordo com as concentrações de PTBAEMA a 0% (controle), 10% e 25% e individualmente inoculados em tubos de falcon contendo 5mL de caldo RPMI para os fungos, TSB para S. aureus e BHI para S. mutans e mantidos em overnight a 37ºC em incubadora com agitação orbital a 75rpm, sendo o S. mutans em microaerofilia. Após a inoculação dos espécimes seguiu-se a formação e maturação do biofilme a 37ºC sob agitação orbital a 75rpm. Em seguida cada espécime foi transferido para tubos contendo PBS e diluições seriadas foram realizadas. Alíquotas dessas diluições foram semeadas em placas de Petri e incubadas a 37ºC por 48h. Os dados obtidos foram transformados em log (UFC+1)/mL, considerando-se α=0,05. Os resultados demonstraram que o grupo contendo 25% de PTBAEMA inibiu completamente a formação de biofilme de S. aureus e S. mutans. Uma redução significativa na contagem de S. aureus e S. mutans (Kruskal- Wallis e Dunn; p=0,001) para o grupo contendo 10% de PTBAEMA foi observada quando comparada aos valores encontrados nos respectivos grupos controle. Para C. albicans não foi encontrada diferença significante entre grupos contendo PTBAEMA e o grupo controle (ANOVA; p>0,05). Conclui-se que os RRCS contendo 10% e 25% de PTBAEMA inibiram a formação de biofilme de S. aureus e S. mutans. Entretanto não teve efeito significante na formação de biofilme de C. albicans. / Abstract: This study evaluated the antimicrobial activity of the resilient reliner Coe Soft ® (RRCS) combined with antimicrobial polymer poly (2-tert butylaminoethyl) methacrylate (PTBAEMA) on Staphylococcus aureus, Streptococcus mutans and Candida albicans biofilm formation. RRCS circular specimens were prepared (n=27), sterilized, divided into three groups according to PTBAEMA concentrations of 0% (control), 10% and 25% and inoculated into individual falcon tubes containing 5 mL of RPMI broth for fungi, TSB for S. aureus and BHI for S. mutans and kept overnight at 37°C with orbital shaking incubator at 75rpm, and S. mutans in microaerophilic. The specimens' inoculations were followed by biofilm formation and its maturation at 37°C under orbital shaking at 75rpm. After that, each sample was transferred to tubes containing PBS and serial dilutions were performed. Aliquots of these dilutions were plated in Petri dishes and incubated at 37°C for 48h. The data were transformed into log (CFU +1)/mL, considering α = 0.05. The results showed that the group containing 25% of PTBAEMA inhibited completely biofilm formation of S. aureus and S. mutans. A significant reduction in counts of S. aureus and S. mutans (Kruskal- Wallis and Dunn; p = 0.001) were found in group containing 10% of PTBAEMA when compared to the values in the corresponding control groups. C. albicans had no significant differences between groups containing PTBAEMA and the control group (ANOVA; p> 0.05). It is concluded that the RRCS containing 10% and 25% PTBAEMA inhibited the biofilmformation of S. aureus and S. mutans. However, no significant effect was found on C. albicans biofilm formation. / Doutor
296

Avaliação das propriedades térmicas, químicas e mecânica relacionando dente bovino e dente humano /

Dutra-Corrêa, Maristela. January 2005 (has links)
Orientador: José Roberto Rodrigues / Resumo: Dentes bovinos são amplamente utilizados substituindo dentes humanos em pesquisas in vitro, para avaliar o comportamento dos materiais odontológicos. Utilizaram-se sessenta dentes bovinos e sessenta humanos. Esmalte e dentina foram avaliados individualmente em Análises Termodiferencial, Termogravimétrica e Condutividade Térmica. A Dissolução foi avaliada em diferentes tempos e concentrações de ácido. No teste de Desidratação os fragmentos foram colocados em estufa por tempos diferentes. Na Incorporação de Água, após a retirada dos fragmentos da estufa, foram resfriados e depois imersos em água destilada. Verificou-se o quanto o tecido incorporou de água em sua massa. A Penetrabilidade de Corante foi avaliada pela Espectroscopia de Fluorescência. Para avaliar a Microdureza Vickers os dentes foram incluídos em resina de poliéster e polidos até expor esmalte ou dentina. No termodiferencial as dentinas comportaram-se semelhantemente. O esmalte bovino absorveu mais energia, indicando mudanças estruturais e apresentando comportamento estável a partir de 450ºC, enquanto que o humano continuou instável. No Termogravimétrico a dentina humana foi duas vezes mais susceptível à perda de massa. Os esmaltes apresentaram Condutividades Térmicas semelhantes. A dentina humana foi mais condutora do que a bovina. Na Dissolução a perda de massa foi mais lenta no dente humano. Na Desidratação o esmalte bovino perdeu aproximadamente 25% e o humano perdeu 2,5%. No esmalte humano houve menor Penetrabilidade de Corante, porém semelhante nas dentinas. Assim, não se deve extrapolar resultados para dente humano em relação à incorporação de água, à penetrabilidade de corante, à dissolução e ao comportamento térmico. / Abstract: Bovine teeth are widely required in substitution of human teeth in in vitro researches to evaluate the behavior of dental materials. Sixth human teeth and sixth bovine teeth were used. Enamel and dentin were individually evaluated under Differential Thermal Analysis, Thermogravimetry and Thermal Conductivity. The dissolution was evaluated for different periods of time and different concentrations of acid. In the dehydration test, the fragments were placed inside a stove for different periods of time. In sorption of water, after the fragments were removed from stove, cooled and immersed in distilled water. It was weighted how much water mass the tissues absorbed. The dyeing penetrability was evaluated under Fluorescence Spectroscopy. To evaluate Vickers Micro hardness, the teeth were placed in polyester resin and polished until enamel or dentin was exposed. In the Differential Thermal the dentin behaved similarly. The bovine enamel absorbed more energy, showing structural changes and reaching stability for temperatures up to 450ºC, while human teeth remained unstable. In the Thermogravimetry, the human dentin was two times more susceptible to mass loss. Both enamels presented similar thermal conductivity. Human dentin presented better conductivity than bovine. In the dissolution, mass loss was slower for human teeth. In the dehydration, bovine enamel lost approximately 25 % while human lost 2.5%. There was smaller dyeing penetrability for human enamel however similar in dentins. Therefore, the results for human teeth may not be extrapolated when related to water absorbing, dyeing penetrability, dissolution and thermal behavior. / Mestre
297

Resistência adesiva de sistemas autocondicionante e convencional frente a diferentes substratos e associação ao laser Nd:YAG : estudo in vitro /

Marimoto, Ângela Regina Kimie. January 2007 (has links)
Orientador: Sérgio Eduardo de Paiva Gonçalves / Banca: Rebeca Di Nicoló / Banca: Marta Solange Rampani Duarte / Resumo: A adesão continua a ser um desafio na Odontologia, principalmente em tecidos morfologicamente distintos e valendo-se de sistemas adesivos de mecanismos de ação também distintos. O objetivo deste estudo in vitro foi comparar a resistência adesiva de dois sistemas (autocondicionante e convencional) em dois substratos (esmalte e dentina), associados ou não à tecnologia laser (Nd:YAG). Foram utilizados 120 dentes bovinos, recém-extraídos, embutidos, que tiveram a superfície de esmalte ou dentina exposta por meio de lixas. Uma área de 3mm de diâmetro na região cérvico-vestibular-mediana foi selecionada para adesão, de acordo com os seguintes grupos: a) G1: AF/ esmalte (adesivo autocondicionante em esmalte seguindo especificação do fabricante); b) G2: AF/ dentina (adesivo autocondicionante em dentina seguindo especificação do fabricante); c) G3: AL/ esmalte (adesivo autocondicionante em esmalte + laser Nd:YAG + fotopolimerização); d) G4: AL/ dentina (adesivo autocondicionante em dentina + laser Nd:YAG + fotopolimerização); e) G5: CF/ esmalte (condicionamento ácido + adesivo convencional em esmalte); f) G6: CF/ dentina (condicionamento ácido + adesivo convencional em dentina); g) G7: CL/ esmalte (condicionamento ácido + adesivo convencional em esmalte + laser Nd:YAG + fotopolimerização); h) G8: CL/ dentina (condicionamento ácido + adesivo convencional em dentina + laser Nd:YAG + fotopolimerização). A resina composta Z 250 foi inserida com auxílio de matriz de teflon e fotopolimerizada com luz halógena, seguida da realização do teste de cisalhamento em máquina universal Emic, com carga de100kgf e velocidade de 0,5mm/min. Os valores médios em MPa obtidos para os diferentes grupos foram: G1 (20,291), G2 (14,142), G3 (23,615), G4 (22,235), G5 (20,899), G6 (11,291), G7 (22,102), G8 (15,980). Após aplicação do teste de ANOVA e Tukey 5%, concluiu-se que... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Bonding continues to be a challenge in Dentistry, particularly in morphologically different tissues, and adhesive systems with different action mechanisms are also valid. The aim of this study was to compare the bond strength of two systems (self-etching and conventional) to two substrates (enamel and dentin) either associated with laser technology (Nd:YAG) or not. One hundred and twenty (120) recently extracted, embedded bovine teeth were used, and abrasive papers were used to expose the enamel or dentin surfaces. An area of 3mm in diameter in the cervical-vestibular-median region was selected for bonding, according to the following groups: a) G1: AF/ enamel (self-etching adhesive to enamel in accordance with the manufacturer's specification); b) G2: AF/ dentin (self-etching adhesive to dentin in accordance with the manufacturer's specification); c) G3: AF/ enamel (self-etching adhesive to enamel + laser Nd:YAG + light polymerization ; d) G4: AL/ dentin (self-etching adhesive to dentin + laser Nd:YAG + light polymerization ; e) G5: CF/ enamel (acid etching + conventional adhesive to enamel); f) G6: CF/ dentin (acid etching + conventional adhesive to dentin); g) G7: CL/ enamel (acid etching + conventional adhesive to enamel + laser Nd:YAG + light polymerization ; h) G8: CL/ dentin (acid etching + conventional adhesive to dentin + laser Nd:YAG + light polymerization). Resin composite Z250 was inserted with the aid of a Teflon matrix and light polymerized, followed by the shear test in an EMIC universal machine, with a load of 100 Kgf and speed of 0.5 mm/min. The mean values obtained in Mpa for the different groups were: G1 (20.291), G2 (14.142), G3 (23.615), G4 (22.235), G5 (20.899), G6 (11.291), G7 (22.102), G8 (15.980). After applying the ANOVA and Tukey tests 5%, it was concluded that the application of laser Nd:YAG significantly increased the bond strength under all the experimental... (Complete abstract click electronic access below) / Mestre
298

Efeito na osseointegração de um novo método de nanotexturização de superfície de implantes através de anodização /

Villaça-Carvalho, Maria Fernanda Lima. January 2016 (has links)
Orientador: Mari Eli Leonelli de Moraes / Co-orientador: Luana Marotta Reis de Vasconcellos / Banca: João Paulo Barros Machado / Banca: Natal Nerímio Regone / Banca: Maria Aparecida Neves Jardini / Banca: Sergio Lucio Pereira de Castro Lopes / Resumo: A Implantodontia é uma das áreas da Odontologia que mais tem evoluído nas últimas décadas. Diversos estudos são desenvolvidos na intenção de otimizar o processo de osseointegração utilizando a nanotopografia na superfície dos implantes. Atualmente o processo de anodização da superfície vem se destacando entre estas técnicas. Desta forma, o objetivo nesta pesquisa foi obter nano rugosidades e fase de anatase em implantes odontológicos de Titânio, buscando a otimização da osseointegração. Sessenta implantes foram caracterizados quanto à morfologia, por meio de microscopia de força atômica (AFM) e Microscopia Eletrônica de Varredura (MEV); quanto à composição química, por análise por detector de espectrometria por espalhamento de energia (EDS) e Espectroscopia Raman; e por fim, quanto ao potencial de corrosão, pela análise de impedância eletroquímica (EIE). A osteogênese, in vivo, foi comparada por Radiografia periapical (RP), Microtomografia Computadorizada (µTC) e teste de remoção por torque reverso; e, a análise in vitro, foi realizada por teste de citotoxicidade por MTT [(brometo de 3-4,5-dimetiltiazol-2-il)-2,5-difeniltetrazoliol]. Os implantes foram divididos em: G1 (controle); Grupo 2 (jateado); Grupo 3 (anodizadoexperimental). Cada coelho recebeu um implante de cada grupo nas tíbias direita e esquerda, e cinco coelhos, foram eutanasiados 2 e 6 semanas após a cirurgia. Os implantes da tíbia direita foram submetidos à RP e à µTC; e os da tíbia esquerda, ao teste de torque reverso e análise de citotoxicidade por MTT. AFM e MEV comprovaram a presença de nano rugosidades na superfície em G3; análises de EDS e Espectroscopia Raman, demonstraram aumento da camada do filme de TiO2 e a obtenção de anatase em G3. Na RP, nenhum implante apresentou halo radiolúcido. Na µTC, G3 foi sempre superior aos demais grupos nos parâmetros observados: BV, BV/TV, Tb.Th. No teste de torque reverso, houve... / Abstract: The Implantology is one of the areas of dentistry that has most evolved in recent decades. Many studies have been developed with the intention of optimizing the osseointegration process using nanotopography on the surface of the implants. Currently the surface of the anodizing process has stood out among these techniques. Thus, the aim of this research was to obtain nano roughness and anatase phase in dental Titanium implants, seeking for the optimization of the osseointegration. Sixty implants were characterized for morphology by atomic force microscopy (AFM) and Scanning Electron Microscopy (SEM); in chemical composition, by mass spectrometry detector energy scattering (EDS) and Raman spectroscopy; and finally, as the potential for corrosion, the electrochemical impedance analysis (EIS). Osteogenesis in vivo was compared by Periapical Radiography (PR), Computed Microtomography (μTC), removal reverse torque test; and in vitro analysis, it was performed by MTT cytotoxicity assay [(bromide 3-4,5-dimethylthiazol-2-yl) -2,5-difeniltetrazoliol]. The implants were divided into G1 (control); Group 2 (sandblasted); Group 3 (anodized-experimental). Each rabbit received an implant of each group in the right and left tibias and five rabbits were euthanized 2 and 6 weeks after surgery. The implants of the right tibia underwent PR and μTC; and the left tibia, the reverse torque test and MTT cytotoxicity assay. AFM and SEM confirmed the presence of nano roughness on the surface in G3; EDS analysis and Raman spectroscopy showed increased TiO2 film layer and obtainment of anatase G3. In PR, no implant presented radiolucent halo. In μTC, G3 has always been higher than the other groups in the observed parameters: BV, BV / TV, Tb.Th. In the reverse torque test, It was required greater removal force of anodized implants. In the MTT test, the experimental implants were nontoxic to cells. It was conclude that the anodizing process used in this study... / Doutor
299

Influência do tratamento de superfície do metal na resistência de união entre uma liga de cobalto-cromo e duas cerâmicas /

Lombardo, Geraldo Henrique Leão. January 2007 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Leonardo Buso / Banca: José Henrique Rubo / Resumo: Este trabalho avaliou a influência do tratamento superficial do metal (jateamento com óxido de alumínio e ponta de tungstênio), na resistência ao cisalhamento, entre uma liga de Co-Cr (StarLoy C - DeguDent) e duas cerâmicas (StarLight Ceram - DegunDent e Duceram Kiss - Degudent). Foram confeccionados quarenta e oito padrões metálicos de formato cilíndrico, com altura total de 4,7 mm, tendo diâmetro diferenciado entre as extremidades; a maior com 5 mm e a menor com 3,7 mm (ISO 11405), sendo doze para cada grupo: G1- superfície metálica jateada com óxido de alumínio + StarLight Ceram; G2- superfície metálica tratada com ponta de tungstênio + StarLight Ceram; G3- superfície metálica jateada com óxido de alumínio + Duceram Kiss e G4- superfície metálica tratada com ponta de tungstênio + Duceram Kiss. O ensaio de cisalhamento foi realizado em máquina de ensaio universal (Emic DL 1000, São José dos Pinhais, Brasil), com célula de carga de 100 Kg, à velocidade de 0,5 mm/min, utilizando um dispositivo específico (faca com entalhe). Após o ensaio, foi realizada a análise fractográfia e os dados obtidos analisados estatisticamente pelo teste ANOVA (2 fatores). Foram observados os seguintes valores médios de resistência de união: G1 (57,97l11,34 MPa); G2 (40,62l12,96 MPa); G3 (47,09l13,19 MPa) e G4 (36,80l8,86 MPa). Concluiu-se que o tratamento superficial com óxido de alumínio, aumentou a resistência de união entre metal e cerâmica, independente do tipo de cerâmica utilizada. / Abstract: The aim of this study was to evaluate the influence of the surface treatment (sandblasting with aluminium oxide and tungsten carbide bur), on the shear bond strength among a Co-Cr alloy (StarLoy C - DeguDent) and two ceramics (StarLight Ceram - DeguDent and Duceram Kiss - Degudent). Forty eigth metal cilindric specimens were made with 4,7 mm high, with two different diameters: one with 5,5 mm and the other with 3,7 mm (ISO 11405), with twelve specimens for each one of the four groups: G1 - sandblasting + StarLigth Ceram; G2 - tungsten carbide burs + StarLigth Ceram; G3 - sandblasting + Duceram Kiss and G4 - tungsten carbide burs + Duceram Kiss. The shear test was made with a universal testing machine (Emic DL 1000, São José dos Pinhais, Brazil), with load of 100 kg, with the crosshead speed of 0,5 mm/min, using a specific device (knife with an indent - Ultradent). The fracture analysis of the surfaces was made and the data were statistically analyzed with the ANOVA (two way). The means and the standard deviations of the shear bond strength were: G1 (57,97l11,34 MPa); G2 (40,62l12,9 MPa); G3 (47,09l13,19 MPa) e G4 (36,80l8,86 MPa). It could be concluded that the surface treatment with the tungsten carbide bur reduced the shear bond strength, independent of the ceramics used. / Mestre
300

Avaliação da microinfiltração bacteriana nas interfaces entre pilares e implantes /

Faria, Renata. January 2008 (has links)
Orientador: Marco antonio Bottino / Banca: Nelson Luiz de Macedo / Banca: Francisco Fernando Todescan / Banca: Diego Klee de Vasconcellos / Resumo: O objetivo nesta pesquisa foi avaliar a infiltração bacteriana in vitro na interface entre o pilar e o implante, comparando-se três tipos de conexões protéticas: Hexágono Externo (HE), Hexágono Interno Indexado (HII) e Cone Morse (CM). Sob condições estéreis, foi inoculada colônia de Escherichia coli na porção apical do parafuso do pilar. Após, os pilares foram fixados aos implantes com torque de 20 N/cm. Foram descartadas as amostras que apresentaram contaminação externa imediata. As amostras foram colocadas em tubos de ensaios contendo 2 ml de caldo TSB estéril. Em acompanhamento diário, por 7 dias, os caldos que se apresentaram turvos foram semeados em placa de petri com TSA e incubados em estufa bacteriológica à 37oC por 24 horas, para a observação de crescimento bacteriano. Coloração Gram foi realizada tanto no caldo quanto na colônia resultante da semeadura, para comprovação da presença de E. coli (Gram-negativo). Ao final do período, todas as amostras foram separadas, o conteúdo interno foi coletado com cone de papel e solução salina e semeado em placas de petri contendo TSA, levadas à estufa bacteriológica a 37º C por, 24 horas para verificar a viabilidade das bactérias. As amostras que não continham E.coli viáveis no seu interior foram descartadas do resultado final. Após os descartes por contaminação externa e inviabilidade, obtiveram-se os seguintes números de amostra: 38 (HE), 40 (HII) e 41 (CM). Os resultados, em % de amostras com infiltração bacteriana, foram submetidos ao teste de comparações múltiplas de proporções. As curvas de sobrevivência foram analisadas pelo método de Kaplan-Meyer e comparadas pelo teste estatístico de Log-Rank. Não houve diferença entre HE (10,53%), HII (4,88%) e CM (7,50%). As curvas de sobrevivência não diferiram entre si. A infiltração bacteriana ocorreu de modo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate, in vitro, the bacterial leakage between implant and abutment comparing three kinds of implantabutments connections: extern hexagon (EH), indexed intern hexagon (IIH) and morse-taper (MT). Under sterile controlled conditions, the tip of the abutment screw was inoculated with Escherichia coli culture and then the abutment was placed in position and tightened (20N/cm). The specimen was discarded if an external contamination of the outer surface was observed. Each specimen was incubated in a glass tube containing 2mL of sterile TSB medium at 37oC. The growth of E. Coli in the medium was registered every 24h. Once the sample showed cloudy broth, it was individually plated on TSA plates and incubated in an anaerobic chamber at 37oC for 24h, in order to observe the bacterial growth. Gram test was performed both in the medium and in the culture to certify the presence of E. Coli (Gram negative). After 7 days, each test specimen was sampled using a sterile paper point which was incubated in TSA plates and incubated in anaerobic chamber at 37oC for 24h, to verify bacterial viability. Samples that did not show bacterial viability in the end of the study were eliminated from the final results. After that, there were 38 EH samples, 40 IIH samples and 41 CM samples. The results, in %, of bacterial leakage, were statistically evaluated by multiple comparisons for proportion. The survival curves were analyzed by Kaplan-Meyer method and compared by statistical test of Log-Rank. There was no statistical difference among EH (10,53%), IIH (4,88%) e MT (7,50%). The three survival curves did not differ (p>0.005). It was conclude that the bacterial leakage occurred in a similar way for the three kinds of implant-abutment interface, no matter the assembly configuration. / Doutor

Page generated in 0.0587 seconds