• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo dos efeitos de algumas soluções irrigadoras sobre a microdureza dentinária e capacidade de remoção da smear layer / Study on the effects of some irrigating solutions on dentine microhardness and smear layer removal

Guerisoli, Danilo Mathias Zanello 07 January 2008 (has links)
Este trabalho estudou os efeitos de algumas soluções irrigadoras sobre a microdureza dentinária e capacidade de remoção da smear layer. As soluções testadas foram: soro fisiológico, hipoclorito de sódio a 2,5%, EDTA a 15% em pH 7,3, EDTA a 15% em pH 9,0, ácido etileno diamino di-succínico (EDDS), Smear Clear® e BioPure MTAD®. Para o estudo de microdureza, 70 fragmentos de dentina medindo 5x5 mm foram obtidos do terço médio de hemissecções radiculares de incisivos bovinos, sendo separados aleatoriamente em sete grupos. A microdureza Knoop inicial da dentina foi aferida por meio de microdurômetro acionado com uma carga de 25 g por 15 s. As amostras eram então tratadas pela imersão nas soluções experimentais por um minuto, após o qual tinham a sua microdureza mensurada. Após mais quatro minutos de imersão nas soluções testadas, os valores de microdureza eram novamente registrados. Os valores de microdureza iniciais e após cada imersão nas soluções testadas foram então submetidos à análise estatística (two-way ANOVA). Para a avaliação da capacidade de remoção da smear layer, 35 raízes de incisivos bovinos foram separadas aleatoriamente em sete grupos e instrumentadas pela técnica step-back. Cada grupo recebeu um tipo de solução irrigadora experimental, ficando estas em contato com as paredes dentinárias por 5 minutos. Os espécimes foram cisalhados e observados ao microscópio eletrônico de varredura com um aumento de 350 vezes para avaliação da remoção da smear layer. Fotomicrografias do terço médio do canal radicular foram obtidas e, por meio de uma grade de integração, foi contabilizado o percentual de áreas contendo smear layer. Os resultados da análise da microdureza dentinária indicaram que, com exceção do soro fisiológico, todas as soluções testadas causaram uma redução significativa desta propriedade. Hipoclorito de sódio a 2,5%, EDDS e Smear Clear® apresentaram resultados semelhantes, causando diminuição da microdureza menos acentuada do que o BioPure MTAD® ou as soluções de EDTA em pH 7,3 ou 9,0. Para a análise de remoção da smear layer, as soluções de EDTA em pH 7,3 ou 9,0, o Smear Clear® e o BioPure MTAD® mostraram resultados semelhantes. O EDDS mostrou semelhanças estatísticas tanto com o hipoclorito de sódio como com as outras soluções quelantes testadas, ocupando uma posição intermediária na capacidade de remoção da smear layer. Pode-se concluir que o EDTA em pHs 7,3 ou 9,0 são estatisticamente semelhantes, bem como o BioPure MTAD®. Enquanto o Smear Clear® é capaz de remover a smear layer sem diminuir a microdureza dentinária, o EDDS reduz moderadamente a microdureza dentinária, porém é deficiente na limpeza das paredes do canal radicular. / This study evaluated the effects of some irrigating solutions on dentine microhardness and smear layer removal. The tested solutions were: saline, 2.5% sodium hypochlorite, 15% EDTA in pH 7.3, 15% EDTA in pH 9.0, ethylene diamine dissuccinic acid (EDDS); Smear Clear® and BioPure MTAD®. For the microhardness study, 70 5x5 mm dentine stubs obtained from the middle third of root hemisections were randomly divided in seven groups. The initial Knoop Hardness Values of the samples were assessed by a microhardness tester with a 25 g load, for 15 s. The samples were then immersed on tested solutions for one minute, after which the KHN values were again measured. One more evaluation of microhardness was performed after four more minutes of treatment with the tested solutions. Results were then submitted to statistical analysis (two-way ANOVA). For the smear layer removal study, 35 bovine incisor roots were randomly assigned to seven groups, according to the irrigating solution, and instrumented following the step-back technique. The irrigating solution was left for 5 minutes in the canals after instrumentation, and then washed with distilled water. Samples were then split and observed under the SEM with 350x magnification. Photomicrographs were obtained from the middle third of the root canal and evaluated for the percentage of remaining smear layer. Results of the microhardness tests showed that all solutions yeld to a hardness reduction of dentine, except saline solution. Sodium hypochlorite, EDDS and Smear Clear presented similar results, with mild reduction of microhardness, while MTAD or EDTA solutions presented severe microhardness alterations. Regarding smear layer removal, EDTA solutions, Smear Clear® and BioPure MTAD® presented similar results, with clean root canal walls and no visible débris. EDDS was more effective than saline solution or sodium hypochlorite, but less effective than the other chelating solutions. It can be concluded that EDTA at pH 7.3 or 9.0 are statistically similar, as well as BioPure MTAD®. While Smear Clear® is able to remove smear layer without reducing dentine microhardness, EDDS does reduce it moderately, but without properly cleaning the root canal walls.
2

Estudo dos efeitos de algumas soluções irrigadoras sobre a microdureza dentinária e capacidade de remoção da smear layer / Study on the effects of some irrigating solutions on dentine microhardness and smear layer removal

Danilo Mathias Zanello Guerisoli 07 January 2008 (has links)
Este trabalho estudou os efeitos de algumas soluções irrigadoras sobre a microdureza dentinária e capacidade de remoção da smear layer. As soluções testadas foram: soro fisiológico, hipoclorito de sódio a 2,5%, EDTA a 15% em pH 7,3, EDTA a 15% em pH 9,0, ácido etileno diamino di-succínico (EDDS), Smear Clear® e BioPure MTAD®. Para o estudo de microdureza, 70 fragmentos de dentina medindo 5x5 mm foram obtidos do terço médio de hemissecções radiculares de incisivos bovinos, sendo separados aleatoriamente em sete grupos. A microdureza Knoop inicial da dentina foi aferida por meio de microdurômetro acionado com uma carga de 25 g por 15 s. As amostras eram então tratadas pela imersão nas soluções experimentais por um minuto, após o qual tinham a sua microdureza mensurada. Após mais quatro minutos de imersão nas soluções testadas, os valores de microdureza eram novamente registrados. Os valores de microdureza iniciais e após cada imersão nas soluções testadas foram então submetidos à análise estatística (two-way ANOVA). Para a avaliação da capacidade de remoção da smear layer, 35 raízes de incisivos bovinos foram separadas aleatoriamente em sete grupos e instrumentadas pela técnica step-back. Cada grupo recebeu um tipo de solução irrigadora experimental, ficando estas em contato com as paredes dentinárias por 5 minutos. Os espécimes foram cisalhados e observados ao microscópio eletrônico de varredura com um aumento de 350 vezes para avaliação da remoção da smear layer. Fotomicrografias do terço médio do canal radicular foram obtidas e, por meio de uma grade de integração, foi contabilizado o percentual de áreas contendo smear layer. Os resultados da análise da microdureza dentinária indicaram que, com exceção do soro fisiológico, todas as soluções testadas causaram uma redução significativa desta propriedade. Hipoclorito de sódio a 2,5%, EDDS e Smear Clear® apresentaram resultados semelhantes, causando diminuição da microdureza menos acentuada do que o BioPure MTAD® ou as soluções de EDTA em pH 7,3 ou 9,0. Para a análise de remoção da smear layer, as soluções de EDTA em pH 7,3 ou 9,0, o Smear Clear® e o BioPure MTAD® mostraram resultados semelhantes. O EDDS mostrou semelhanças estatísticas tanto com o hipoclorito de sódio como com as outras soluções quelantes testadas, ocupando uma posição intermediária na capacidade de remoção da smear layer. Pode-se concluir que o EDTA em pHs 7,3 ou 9,0 são estatisticamente semelhantes, bem como o BioPure MTAD®. Enquanto o Smear Clear® é capaz de remover a smear layer sem diminuir a microdureza dentinária, o EDDS reduz moderadamente a microdureza dentinária, porém é deficiente na limpeza das paredes do canal radicular. / This study evaluated the effects of some irrigating solutions on dentine microhardness and smear layer removal. The tested solutions were: saline, 2.5% sodium hypochlorite, 15% EDTA in pH 7.3, 15% EDTA in pH 9.0, ethylene diamine dissuccinic acid (EDDS); Smear Clear® and BioPure MTAD®. For the microhardness study, 70 5x5 mm dentine stubs obtained from the middle third of root hemisections were randomly divided in seven groups. The initial Knoop Hardness Values of the samples were assessed by a microhardness tester with a 25 g load, for 15 s. The samples were then immersed on tested solutions for one minute, after which the KHN values were again measured. One more evaluation of microhardness was performed after four more minutes of treatment with the tested solutions. Results were then submitted to statistical analysis (two-way ANOVA). For the smear layer removal study, 35 bovine incisor roots were randomly assigned to seven groups, according to the irrigating solution, and instrumented following the step-back technique. The irrigating solution was left for 5 minutes in the canals after instrumentation, and then washed with distilled water. Samples were then split and observed under the SEM with 350x magnification. Photomicrographs were obtained from the middle third of the root canal and evaluated for the percentage of remaining smear layer. Results of the microhardness tests showed that all solutions yeld to a hardness reduction of dentine, except saline solution. Sodium hypochlorite, EDDS and Smear Clear presented similar results, with mild reduction of microhardness, while MTAD or EDTA solutions presented severe microhardness alterations. Regarding smear layer removal, EDTA solutions, Smear Clear® and BioPure MTAD® presented similar results, with clean root canal walls and no visible débris. EDDS was more effective than saline solution or sodium hypochlorite, but less effective than the other chelating solutions. It can be concluded that EDTA at pH 7.3 or 9.0 are statistically similar, as well as BioPure MTAD®. While Smear Clear® is able to remove smear layer without reducing dentine microhardness, EDDS does reduce it moderately, but without properly cleaning the root canal walls.
3

Clareamento dental interno: efeito de diferentes sistemas na microdureza e micromorfologia superficial da dentina bovina / Effect of different bleaching systems on the microhardness and ultrastructure of bovine dentin

Guerisoli, Laise Daniela Carrasco 07 January 2008 (has links)
Este estudo teve como objetivos: 01.Avaliar ex vivo o efeito de diferentes sistemas clareadores na microdureza dentinária em dentes bovinos submetidos ao clareamento dental interno. 02.Avaliar ex vivo o efeito de diferentes sistemas clareadores na morfologia superficial da dentina bovina. Fragmentos de 4 x 4mm, contendo esmalte e dentina, foram obtidos de coroas de incisivos bovinos extraídos. Os espécimes foram submetidos ao clareamento dental interno com peróxido de hidrogênio a 35% e peróxido de carbamida a 37% utilizando sistemas convencionais (Opalescence Endo® and Whiteness Super Endo®) e fotoativados (Opalescence Xtra® and Whiteness HP Maxx®). Os controles foram tratados com perborato de sódio misturado com peróxido de hidrogênio a 10% ou nenhum tratamento foi realizado. A microdureza dentinária foi mensurada antes e após os tratamentos clareadores, e os valores de dureza Knoop (KHN) foram submetidos à análise estatística (two-way ANOVA, Tukey\'s port-test). Os espécimes foram observados e fotografados sob microscópio eletrônico de varredura e avaliados com relação às alterações morfológicas da superfície da dentina. Houve uma redução significante na microdureza dentinária para todos os grupos testados quando comparados aos grupos controles. Opalescence Xtra® (-11.36 ± 8.14 KHN), Opalescence Endo® (-13.71 ± 8.02 KHN), Whiteness HP Maxx® (-15.18 ± 9.58 KHN) e Whiteness Super Endo® (-16.97 ± 6.55 KHN) foram semelhantes estatisticamente. O grupo do perborato de sódio misturado com peróxido de hidrogênio 10% (2.10 ± 8.58 KHN) e o grupo sem tratamento clareador (-2.71 ± 2.40 KHN) também foram estatisticamente semelhantes entre si. Ocorreu uma grande variação no padrão de alterações da morfologia superficial da dentina com os sistemas clareadores utilizados. Todos os produtos testados apresentaram redução significativa da microdureza dentinária, exceto o grupo de perborato de sódio misturado com peróxido de hidrogênio a 10%. Ambos, pH e oxidação do peróxido de hidrogênio apresentam o papel de alterar a estrutura da dentina durante o clareamento interno. A utilização de produtos alcalinos com um tempo reduzido de aplicação (técnicas fotoativadas) pode diminuir as alterações morfológicas na dentina. / The aim of this study was: 01. To evaluate in vitro the effect of different in-office bleaching systems on the surface morphology of bovine dentin. 02. To evaluate ex vivo the effect of different bleaching systems on the microhardness of bovine dentine. Tooth fragments measuring 4 x 4mm, containing enamel and dentin, were obtained from the crowns of extracted bovine incisors. Samples were submitted to simulated intracoronal bleaching techniques with 35% hydrogen peroxide and 37% carbamide peroxide using conventional (Opalescence Endo® and Whiteness Super Endo®) and light activated systems (Opalescence Xtra® and Whiteness HP Maxx®). Controls were treated either with sodium perborate mixed with 10% hydrogen peroxide or no bleaching agent. Dentine microhardness values were measured before and after bleaching procedures, recorded as KHN (Knoop Hardness Number), and the differences between them analyzed (two-way ANOVA, Tukey\'s port-test). The samples were observed under SEM and the recorded images were evaluated for topographic alterations. Significant reductions of dentine microhardness were observed for all treatments when compared to the control groups. Opalescence Xtra® (-11.36 ± 8.14 KHN), Opalescence Endo® (-13.71 ± 8.02 KHN), Whiteness HP Maxx® (-15.18 ± 9.58 KHN) and Whiteness Super Endo® (- 16.97 ± 6.55 KHN) presented similar differences. The walking bleach technique (2.10 ± 8.58 KHN) and the untreated groups (-2.71 ± 2.40 KHN) were statistically alike.The ultrastructural alterations of dentin observed in this study varied greatly between groups, according to the products used. Apparently, higher pH products associated to in-office techniques yielded to better maintenance of dentin ultrastructure. The in-office products tested in the present study caused a significant reduction in dentine microhardness. The walking bleach technique did not affect dentine microhardness. Both low pH and hydrogen peroxide oxidation play a role in altering the ultrastructure of dentin during internal dental bleaching. The use of alkaline products with reduced time of application (in-office techniques) may decrease such morphological alterations.
4

Clareamento dental interno: efeito de diferentes sistemas na microdureza e micromorfologia superficial da dentina bovina / Effect of different bleaching systems on the microhardness and ultrastructure of bovine dentin

Laise Daniela Carrasco Guerisoli 07 January 2008 (has links)
Este estudo teve como objetivos: 01.Avaliar ex vivo o efeito de diferentes sistemas clareadores na microdureza dentinária em dentes bovinos submetidos ao clareamento dental interno. 02.Avaliar ex vivo o efeito de diferentes sistemas clareadores na morfologia superficial da dentina bovina. Fragmentos de 4 x 4mm, contendo esmalte e dentina, foram obtidos de coroas de incisivos bovinos extraídos. Os espécimes foram submetidos ao clareamento dental interno com peróxido de hidrogênio a 35% e peróxido de carbamida a 37% utilizando sistemas convencionais (Opalescence Endo® and Whiteness Super Endo®) e fotoativados (Opalescence Xtra® and Whiteness HP Maxx®). Os controles foram tratados com perborato de sódio misturado com peróxido de hidrogênio a 10% ou nenhum tratamento foi realizado. A microdureza dentinária foi mensurada antes e após os tratamentos clareadores, e os valores de dureza Knoop (KHN) foram submetidos à análise estatística (two-way ANOVA, Tukey\'s port-test). Os espécimes foram observados e fotografados sob microscópio eletrônico de varredura e avaliados com relação às alterações morfológicas da superfície da dentina. Houve uma redução significante na microdureza dentinária para todos os grupos testados quando comparados aos grupos controles. Opalescence Xtra® (-11.36 ± 8.14 KHN), Opalescence Endo® (-13.71 ± 8.02 KHN), Whiteness HP Maxx® (-15.18 ± 9.58 KHN) e Whiteness Super Endo® (-16.97 ± 6.55 KHN) foram semelhantes estatisticamente. O grupo do perborato de sódio misturado com peróxido de hidrogênio 10% (2.10 ± 8.58 KHN) e o grupo sem tratamento clareador (-2.71 ± 2.40 KHN) também foram estatisticamente semelhantes entre si. Ocorreu uma grande variação no padrão de alterações da morfologia superficial da dentina com os sistemas clareadores utilizados. Todos os produtos testados apresentaram redução significativa da microdureza dentinária, exceto o grupo de perborato de sódio misturado com peróxido de hidrogênio a 10%. Ambos, pH e oxidação do peróxido de hidrogênio apresentam o papel de alterar a estrutura da dentina durante o clareamento interno. A utilização de produtos alcalinos com um tempo reduzido de aplicação (técnicas fotoativadas) pode diminuir as alterações morfológicas na dentina. / The aim of this study was: 01. To evaluate in vitro the effect of different in-office bleaching systems on the surface morphology of bovine dentin. 02. To evaluate ex vivo the effect of different bleaching systems on the microhardness of bovine dentine. Tooth fragments measuring 4 x 4mm, containing enamel and dentin, were obtained from the crowns of extracted bovine incisors. Samples were submitted to simulated intracoronal bleaching techniques with 35% hydrogen peroxide and 37% carbamide peroxide using conventional (Opalescence Endo® and Whiteness Super Endo®) and light activated systems (Opalescence Xtra® and Whiteness HP Maxx®). Controls were treated either with sodium perborate mixed with 10% hydrogen peroxide or no bleaching agent. Dentine microhardness values were measured before and after bleaching procedures, recorded as KHN (Knoop Hardness Number), and the differences between them analyzed (two-way ANOVA, Tukey\'s port-test). The samples were observed under SEM and the recorded images were evaluated for topographic alterations. Significant reductions of dentine microhardness were observed for all treatments when compared to the control groups. Opalescence Xtra® (-11.36 ± 8.14 KHN), Opalescence Endo® (-13.71 ± 8.02 KHN), Whiteness HP Maxx® (-15.18 ± 9.58 KHN) and Whiteness Super Endo® (- 16.97 ± 6.55 KHN) presented similar differences. The walking bleach technique (2.10 ± 8.58 KHN) and the untreated groups (-2.71 ± 2.40 KHN) were statistically alike.The ultrastructural alterations of dentin observed in this study varied greatly between groups, according to the products used. Apparently, higher pH products associated to in-office techniques yielded to better maintenance of dentin ultrastructure. The in-office products tested in the present study caused a significant reduction in dentine microhardness. The walking bleach technique did not affect dentine microhardness. Both low pH and hydrogen peroxide oxidation play a role in altering the ultrastructure of dentin during internal dental bleaching. The use of alkaline products with reduced time of application (in-office techniques) may decrease such morphological alterations.

Page generated in 0.0942 seconds