• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • 21
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 61
  • 61
  • 37
  • 26
  • 19
  • 15
  • 12
  • 11
  • 11
  • 9
  • 9
  • 8
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo clínico e histopatológico da mucosa palatina em pacientes não usuários de prótese e em usuários de prótese com câmara de sucção /

Castro, Eni Vaz Franco Lima de. January 2005 (has links)
Orientador: Ana Maria Pires Soubhia / Banca: José Maria Berão / Banca: Alexandre Vieira Fernandes / Banca: Leda Maria Pescinini Salzedas / Banca: Ronaldo Maia Melhado / Resumo: Considerando-se a significativa importância do melhor conhecimento acerca das lesões de maior ocorrência no cotidiano do cirurgião-dentista, justifica-se o estudo das hiperplasias fibrosas inflamatórias em geral, especialmente aquelas de inter-relacionamento com a atuação direta do profissional, como as hiperplasias protéticas. No presente estudo, foram observados os aspectos clínicos e microscópicos da mucosa palatina em pacientes não usuários e usuários de prótese, com a finalidade de se identificar a possibilidade de direta relação entre lesão e suposto agente causal. No sentido de se tentar realizar um estudo mais abrangente e com resultados mais confiáveis, o presente trabalho foi desenvolvido em dois capítulos distintos, analisando-se inicialmente a mucosa palatina clinicamente normal de trinta pacientes usuários e não usuários de prótese total superior, observando-se que a presença de hiperplasia no epitélio de revestimento da mucosa palatina é um achado constante, tanto em usuários como em não usuários de prótese, sendo que a ausência de alterações clínicas nem sempre reflete a mesma normalidade ao exame histopatológico, sem uma relação de dependência entre inflamação e presença de hiperplasia epitelial e vice versa, em ambos os grupos. No segundo capítulo, foram estudados vinte e três pacientes com hiperplasia fibrosa palatina por câmara de sucção, antes e após tratamento compressivo, observando-se que lesões hiperplásicas podem não apresentar um quadro inflamatório crônico, sugerindo que o preenchimento gradativo da área de câmara de sucção é uma opção terapêutica de valor para esses casos. / Abstract: Being considered the significant importance of the best knowledge concerning the lesions of larger occurrence in the routine of Surgeon Dentist, it is justified the study of the inflammatory fibrous hyperplasias in general, especially those of inter-relationship with the professional's direct performance, as the prosthetic hyperplasias. In the present study, the clinical and microscopic aspects of the palatine mucous membrane were observed in patients wearing or not total prosthesis, with the purpose of identifying the possibility of direct relationship between lesion and supposed causal agent. As an examining to try to accomplish a broader study with more reliable results, the present work was developed in two different chapters, being analyzed the clinically normal palatine mucous membrane of thirty patients initially wearing and not wearing of upper complete denture, being observed that the presence of hyperplasia in the epithelium coating of palatine mucous membrane is a constant discovery, as in wearing as in not prosthesis wearing individuals, and the absence of clinical alterations not always it reflects the same normality to the histopathologic exam, without a dependence relationship between inflammation and presence of epithelial hyperplasia and vice-versa, so much in wearing as in not prosthesis wearing. In the second chapter, twenty-three patients with palatine fibrous hyperplasia for suction chamber were studied, before and after treatment by use of tissue conditioning. It was observed that hyperplasic lesions cannot present a chronic inflammatory picture, suggesting that the gradual completion of the area of suction chamber is an important therapeutic option for those cases. / Doutor
22

Influência do processamento de próteses totais superiores em função da profundidade do palato : análise da movimentação dos dentes artificiais por computação gráfica /

Vedovatto, Eduardo. January 2005 (has links)
Orientador: Humberto Gennari Filho / Banca: Marcelo Coelho Goiato / Banca: Valdir Antonio Muglia / Resumo: Em função do relacionamento existente entre a profundidade do palato e as alterações das bases de resina acrílica, esse trabalho investigou a movimentação dos dentes que ocorrem quando próteses totais são processadas com diferentes materiais e técnicas e a relação com o formato do palato. Foram confeccionadas vinte e oito réplicas de próteses totais sobre modelos maxilares com palato raso e vinte e oito réplicas para o palato profundo, idênticas quanto ao enceramento e posicionamento dos dentes. As próteses foram divididas em oito grupos com sete espécimes cada, de acordo com o tipo de resina utilizada, o material utilizado para inclusão em mufla e o tipo de palato. Foram demarcados pontos sobre os dentes que serviram de referência para as mensurações através do software AutoCAD 2005. As mensurações foram realizadas em dois estágios: após o enceramento das próteses e após a demuflagem (não separadas do modelo). Os resultados foram submetidos à análise de variância e as comparações ao teste de Tukey com probabilidade de 5%. Os resultados mostraram que não houve diferença estatisticamente significante entre os grupos estudados, porém quando a análise ocorreu num contexto geral, diferença estatisticamente significativa foi observada para as variáveis, formato de palato e material de inclusão. Baseado nos resultados pode-se concluir que: o formato do palato influencia nas alterações dos dentes artificiais; o palato profundo sofreu alterações dentais significantemente inferiores que o palato raso; as próteses incluídas com silicone apresentaram alterações significantemente superiores às incluídas com gesso; o tipo de resina utilizada não acarretou em alterações estatísticamente significantes entre si; a região posterior das próteses apresentou maiores alterações em relação à região anterior. / Abstract: About the relationship between the palate depth and the changes in acrylic resins base-plate, this work investigate the teeth movement that occurs when the complete dentures were processed by different materials, techniques and its relation to the palatal form. Twenty eight samples of complete dentures in maxillary cast with shallow palate form and twenty eight with deep palate form were constructed for the study. The samples presented similarities in the artificial teeth position. This prosthesis were divided in eight groups with seven specimens each, in agreement with the resin type for inclusion, the type of material used in the covering and the type of the palate depth. Points were demarcated on the teeth, which served as reference for the measurements of the segments (among the teeth), through software AutoCAD 2005. The measurements are accomplished in two moments: after the waxed and after the desflasking (not descasting). The results were submitted to the analysis of variance and comparisons to the Tukeyþs test with probability of 5%. The results showed no statistical significantly differences between the groups, but when the variables were study in global context difference were observed for the palatal form and covering materials. Based on the results conclude that: the palatal form influence on the changes of teeth position. The deep palate showed alterations significantly inferior that presented for the shallow palate. The silicon used for the covering results in greater alterations in relation to the stone mold. The type of resin not differs in the alterations of teeth position (not significantly). The change of teeth position was greater in the posterior region compares to the anterior region of the prosthesis. / Mestre
23

Oral health technology assessment : study of mandibular 2-implant overdentures

Esfandiari, Shahrokh. January 2008 (has links)
There is little evidence that Health Technology Assessment (HTA) is much used in dentistry. Dental implant technology is an example of innovative oral health technology. The objectives of this research were to gather the evidence needed for the assessment of overdenture implant treatment so that both patients and dental practitioners can make informed decisions about this technology. These objectives included 1) investigating what types of dental clinicians adopt and provide dental implants 2) determining the effect of the clinicians' experience in the provision of implant supported prostheses and 3) measuring the patients' preference in provision of mandibular 2-implants overdenture technology. / For the first part, a cross-sectional survey was sent to all licensed Canadian Dentists to measure the adoption and provision of implant technology. For the second part, we used the data on the first 140 edentulous elders who were enrolled in a randomized controlled clinical trial to compare the effects of mandibular conventional (CD) and 2-implant overdentures (IOD) on nutrition. The change in patient ratings of satisfaction after treatment, laboratory costs and the number of unscheduled visits were compared. For the last part, edentulous elders (N=36) who were wearing maxillary dentures and either a mandibular conventional denture (CD, n=13) or a two-implant overdenture (IOD, n=23) participated in this study. Participants' preference was measured during a 20-minute interview. / Multivariate regression analysis on the data from the first part of the study shows that the Dentist's gender, province of practice, specialty, and whether they practice alone or in association with other practitioners, are significantly associated with the adoption of implant technology (p<0.05). It is also shown that there was no difference in satisfaction scores for either prosthesis between the groups treated by experienced specialists or new dentists. Furthermore, it is shown that IOD wearers were willing to pay three times more than the current cost of conventional dentures for implant prostheses (p<0.05). / Overall, the results of this study 1) inform decision makers on what types of clinicians provide implant technology and 2) suggest that, with minimal training, all dental clinicians irrespective of their specialty, can provide successful implant overdenture prostheses that edentulous patients are willing to pay for.
24

Measuring real world effectiveness of mandibular 2-implant overdentures a pragmatic international multicenter study /

Rashid, Faahim. January 1900 (has links)
Thesis (M.Sc. / Written for the Faculty of Dentistry. [Dept. of Dental Sciences]. Title from title page of PDF (viewed 2008/07/30). Includes bibliographical references.
25

Effects of aging and denture wearing on mandibular size a thesis submitted in partial fulfillment ... denture prosthodontics /

Parra, Cecilia Perdomo. January 1971 (has links)
Thesis (M.S.)--University of Michigan, 1971.
26

Effects of aging and denture wearing on mandibular size a thesis submitted in partial fulfillment ... denture prosthodontics /

Parra, Cecilia Perdomo. January 1971 (has links)
Thesis (M.S.)--University of Michigan, 1971.
27

Influência da utilização de adesivos para prótese na adesão e formação de biofilme simples e misto /

Oliveira Junior, Norberto Martins de. January 2018 (has links)
Orientador: Marco Antonio Compagnoni / Resumo: Objetivos: Verificar se os adesivos Ultra Corega Creme e Corega Fita Adesiva interferem na adesão e formação de biofilme simples e misto de Candida albicans e de Lactobacillus casei, e observar possíveis relações de sinergismo ou antagonismo entre as espécies. Metodologia: Espécimes em resina acrílica termopolimerizável (Lucitone 550) foram confeccionados (N=144), de formato circular e com rugosidade padronizada (3,0 μm ±0,3), e foram divididos em três grupos: Sem Adesivo, com Adesivo Ultra Corega Creme e com Adesivo Corega Fita Adesiva. Estes foram divididos em três subgrupos cada: C. albicans simples, L. casei simples e misto de C. albicans com L. casei. Foram feitos ensaios de adesão e de formação de biofilme em duplicata, resultando em 8 espécimes (n=8) por condição experimental. Foi observada a quantidade de cada micro-organismo nas superfícies dos espécimes através de contagem de Unidades Formadoras de Colônia (UFC) por mL e foi feita a caracterização dos espécimes através de Microscopia Eletrônica de Varredura (MEV), sendo utilizados 18 espécimes nesta análise (N=18), 2 por condição experimental (n=2). Análise de variância por ANOVA dois fatores e teste de Tukey para comparações múltiplas foram empregados, e um nível de significância de 0,05 foi obedecido para todas as comparações realizadas. Resultados: L. casei só apresentou diferença de adesão em uma situação de seu cultivo misto, na qual L. casei (misto) aderiu mais na situação Sem Adesivo do que quando o Adesivo C... (Resumo completo, clicar acesso eletrônico abaixo) / To verify whether the adhesives Ultra Corega Cream and Corega Strips interfere in the adhesion and biofilm formation by Candida albicans and Lactobacillus casei in single- and mixed-species setup, and observe possible synergistic or antagonistic relationships between these species. Methodology: Specimens made from heat-polymerized acrylic resin (Lucitone 550) were fabricated (N=144), with circular shape and standardized roughness (3.0 μm ±0.3), and were divided into three groups: Without Adhesive, with Adhesive Ultra Corega Cream and with Adhesive Corega Strips. These groups were divided into three subgroups each: C. albicans single-species, L. casei single-species and C. albicans with L. casei (mixedspecies). Microbial adhesion and biofilm formation assays were performed in duplicate, resulting in 8 specimens (n=8) per experimental condition. The amount of each microorganism on the surfaces of the specimens was observed by counting of Colony Forming Units (CFU) per mL and the specimens were characterized by Scanning Electron Microscopy (SEM), being used 18 specimens in this analysis (N=18), 2 per experimental condition (n=2). Analysis of variance by ANOVA two-way and Tukey's test for multiple comparisons were employed, and a significance level of 0.05 was obeyed for all comparisons. Results: L. casei showed only one difference of adhesion in a situation of its mixed-species cultivation, in which L. casei (mixedspecies) adhered more in the situation Without Adhesive than when Cream Adhesive was used, and C. albicans (single- and mixed-species) adhered more when Strips Adhesive was used. C. albicans both single- and mixed-species adhered more than L. casei (single- and mixed-species). L. casei (single) formed more biofilm in the situation Without Adhesive, but in its mixed cultivation with C. albicans had no difference of growth in the tested situatio.... (Complete abstract electronic access below) / Doutor
28

Avaliação da desadaptação e microdureza superficial de quatro resinas acrílicas para base de dentaduras utilizando métodos de polimerização e armazenagem em água /

Miessi, Ana Carolina. January 2005 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Adriana Cristina Zavanelli / Banca: Mauro Antônio de Arruda Nóbilo / Resumo: O objetivo deste trabalho foi avaliar a desadaptação e a microdureza superficial de quatro tipos de resinas acrílicas para base de dentaduras, em função de período de armazenagem em água de seis meses. Foram confeccionados vinte e cinco conjuntos modelo de gesso-base de resina, utilizando-se quatro resinas acrílicas: QC-20 que foi submetida à polimerização convencional (de acordo com as instruções dos fabricantes) e por energia de microondas (840 W por três minutos), Vipi Cril submetida à polimerização convencional (fabricante), Vipi Wave e Onda Cryl que receberam polimerização por energia de microondas conforme as recomendações dos fabricantes. Após a polimerização, os conjuntos modelo de gesso-base de resina foram seccionados na região posterior correspondente a região de "post-dam" para a leitura da desadaptação, com auxílio de um microscópio comparador, em três pontos referenciais: crista dos rebordos direito e esquerdo e região mediana do palato. Os conjuntos seccionados foram, então, imersos em água destilada a 35 l 2ºC por período de noventa dias, após o qual uma segunda leitura da desadaptação foi realizada. Imediatamente, os conjuntos modelo-base de resina foram separados e a bases de resina retiradas para a remoção dos excessos grosseiros da borda até o limite estabelecido pelo modelo de gesso. Posteriormente, as bases de resina acrílica foram fixadas nos respectivos modelos com adesivo de presa rápida colocado na região correspondente à crista do rebordo alveolar e uma terceira leitura para analisar a desadaptação, nos pontos referenciais, foi realizada. Após a terceira leitura, os conjuntos ficaram novamente imersos em água destilada a 35 l 2ºC e armazenados em estufa por um período de mais noventa dias, findo o qual uma quarta leitura nos pontos previamente demarcados foi...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this work was to evaluate the missfitting and the superficial microhardness of four acrylic resins types for dentures base due to storage period in six months water. 25 model sets of resin plaster-base have been confectioned using four acrylic resins: QC-20, which was submitted to the conventional polymerization (in accordance with the manufacturer's instructions) and microwaves energy polymerization (840W for three minutes) and Vipi Wave and Onda Cryl, which have received microwaves energy polymerization also in accordance with the manufacturer's recommendations. After the polymerization process, the model sets of resin plaster-base were parted in the corresponding posterior region, the "post-dam" region, for the missfitting analysis. This was supported by a comparing microscope in three reference points: right and left crest of ridges and palate's middle region. The parted sets have been, then, immersed in distilled water about 35 to 2°C, for a 90-day period which was followed by a second missfitting analysis. The resin base-model sets were immediately separated and the resin bases were immediately removed to promote the edge coarse excesses' removal until the limit established by the plaster model. Later, the acrylic resin bases were fixed in the respective models with fast stick adhesive, which was placed in the corresponding region to the alveolar crest of ridges. A third analysis to study the missfitting in the reference points was carried through. After the third analysis the sets were immersed again in distilled water about 35 to 2ºC and stored in a stove for a certain period, which exceeded 90 days. As soon as this period was finished, a fourth analysis was carried through in the points previously outlined (180 days total analysis period...(Complete abstract, click electronic address below) / Mestre
29

Estudo cinesiográfico do espaço de pronúncia do som /s/ em indivíduos dentados e desdentados /

Souza, Raphael Freitas de. January 2003 (has links)
Orientador: Marco Antonio Compagnoni / Banca: Francisco de Assis Mollo Junior / Banca: Cláudio Rodrigues Leles / Resumo: Os sons sibilantes, como o /s/, vêm sido usados para avaliar a determinação da dimensão vertical e posicionamento de dentes artificiais. Apesar desse som poder ser destorcido por próteses totais, algum grau de adaptação é esperado. O propósito deste estudo foi avaliar o espaço de pronúncia do /s/ (EPS) em indivíduos dentados e edentados e relacioná-lo aos trespasses incisais e espaço funcional livre (EFL). Dois grupos foram recrutados: I- composto por 25 indivíduos do gênero masculino e 36 do gênero feminino (n = 61) com média etária de 30,26 l 12,71 anos; e II- 10 indivíduos do gênero masculino e 23 do gênero feminino (n = 33) com média etária de 59,18 l 10,00 anos. A análise foi realizada empregando o instrumento cinesiográfico K6 I Diagnostic System (Myotronics Research, Inc., Seattle, WA, EUA) que fornece registros tridimensionais dos movimentos mandibulares. Os indivíduos foram avaliados pela pronúncia da palavra "seis" e as posições mandibulares para o som /s/ em relação à máxima intercuspidação foram registradas. Os trespasses vertical e horizontal, bem como o EFL, também foram mensurados. Os resultados indicaram movimento mandibular protrusivo durante a produção do som /s/ para quase todos os indivíduos do grupo I, mas no grupo II houve uma predominância de retrusão. Idade e gênero não influenciaram o EPS para os dois grupos. Foi encontrada correlação significativa entre o EPS do /s/ e ambos os trespasses para o grupo I, mas não para o grupo II. Houve uma fraca correlação entre os EFL e EPS para o grupo I, mas uma correlação relativamente forte para o grupo II. Esses dados sugerem que o tratamento com próteses totais influenciou a movimentação mandibular durante a produção do /s/. Dessa forma, pode se deduzir que mudanças anatômicas seguindo o procedimento protético produziu uma adaptação funcional nítida que foi ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The sibilant sounds, such as /s/, have been used as evaluation in determining vertical dimension and placement of artificial teeth. Although it can be distorted by complete dentures, some degree of adaptation can be expected. The aim of this study was to evaluate the /s/ speaking space (SSP) in dentate and edentate subjects, and relate it to the incisal overlaps and freeway space (FS). Two groups were recruited, as follows: I- composed by 25 male and 36 female dentate subjects (n = 61), with mean age of 30,26 l 12,71 years; and II- 10 male and 23 female dentate subjects (n = 33), with mean age of 59,18 l 10,00 years. The kinesiographic equipment K6 I Diagnostic System (Myotronics Research, Inc., Seattle, WA, USA) was used for the assessment, providing three-dimensional records of mandibular movements. Each subject was tested by pronouncing the word 'seis' and the mandibular positions for /s/ sound, in relation to maximal intercuspal position, were recorded. The vertical and horizontal overlaps, and also the freeway space, were also measured. The results showed protusive mandibular movement /s/ production for almost all subjects in group I, but in group II there was a predominance of retrusion. Age and gender didn't influence the measured speaking space for the two groups. Significant correlation was found between SSP and both overlaps for group I, but not for group II. There was a slight correlation between FS and SSP for group I, but a relatively strong correlation for group II. It was suggested that the complete denture treatment influenced the mandibular motion during /s/ production. Also, it can be deduced that anatomic changes following the prosthetic procedure strongly produced functional adaptation that was common for both rest and /s/ speaking positions of the mandible. / Mestre
30

Efeito da escovação mecanica e da termociclagem sobre dureza e rugosidade superficiais de reembasadores resilientes / Effect of mechanical brushing and ageing by thermal cycling on hardness and roughness surface of resilient soft liners

Hermann, Caio 24 February 2005 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:47:30Z (GMT). No. of bitstreams: 1 Hermann_Caio_M.pdf: 1426714 bytes, checksum: 9b5d60e0226de3bf4200bec3b2f9f1c7 (MD5) Previous issue date: 2005 / Resumo: Este trabalho teve como objetivo avaliar o efeito da escovação mecânica e termociclagem sobre dureza e rugosidade superficiais de três materiais reembasadores resilientes considerados definitivos, dois à base de silicone, um auto (Sofreliner MS) e outro termopolimerizável (Molloplast-B), além de um à base de resina acrílica autopolimerizável (Dentuflex). Para a confecção das amostras, foram utilizadas matrizes de silicone polimerizado por reação de condensação incluídas em muflas, obtendo um molde impresso no gesso posteriormente preenchido com os materiais resilientes. Foram confeccionadas 60 amostras, submetidas à leitura de rugosidade superficial num rugosímetro SURFCORDER SE 1700 (Kosaka Laboratory) e à leitura de dureza num durômetro Shore A (GS ¿ 709 Teclock, Osaka, Japão). Em seguida as amostras foram separadas em dois grupos, onde metade foi submetida ao ensaio de termociclagem numa máquina MSCT ¿ 3 PLUS regulada em 2.000 ciclos com banhos alternados de 60 segundos a 5±1oC e 55±1oC e a outra metade ao ensaio de escovação mecânica numa máquina MSEt, seguida de termociclagem. O ensaio de escovação foi executado sob carga estática de 200 g, com movimentos lineares, totalizando 30.000 ciclos, onde uma solução de dentifrício contendo água era liberada a cada 1 minuto sobre as amostras. Após os ensaios, foram executadas novas leituras de dureza e rugosidade superficial. Os valores obtidos foram submetidos à análise de variância em parcelas subdivididas no tempo, seguida do teste de Tukey em nível de 5% de significância. O material Dentuflex apresentou os maiores valores médios de rugosidade e dureza iniciais, seguidos do Molloplast-B e Sofreliner MS. Após termociclagem, os materiais Dentuflex e Sofreliner MS apresentaram aumento estatisticamente significante da dureza. Após escovação, o material Dentulfex apresentou diminuição nos valores de rugosidade e o Sofreliner MS aumento, ambos estatisticamente significantes. Após a escovação seguida de termociclagem, todos os materiais apresentaram valores de rugosidade estatisticamente semelhantes entre si, provavelmente devido ao polimento do material Dentuflex, abrasão do Sofreliner MS e preservação das características do Molloplast-B / Abstract: The aim of this study was to evaluate the effect of mechanical brushing and thermocycling on hardness and roughness of three resilient definitive lining materials: 1) auto (Sofreliner MS), 2) heat-polymerized (Molloplast-B) silicone bases; and 3) auto-polymerized plasticized acrylic resin (Dentuflex). To prepare the samples, silicone rubber matrixes were made and placed in a flask to obtain a cast pressed mold, and then filled with resilient lining materials, handled according to the manufacturer¿s directions. All samples were submitted to surface roughness readings in a roughness readings machine (SURFCORDER SE 1700 ¿ Kosaka Laboratory) and hardness readings in a Shore A durometer (GS ¿ 709 Teclock, Osaka, Japan). After the readings, the samples were assigned into 6 groups of 10 each, half of which were submitted to thermocycling treatment in a thermal cycler machine (MSCT ¿ 3 PLUS) for 2.000 cycles at temperatures ranging from 5±1oC to 55±1oC and a 60-second dwell time. The other half was submitted to a mechanical brushing simulation in an MSEt brushing machine followed by thermocycling. The samples were submitted to 30.000 strokes with linear brushing movements, under a 200 g static load pressure. Toothpaste solution was injected every one-minute break. Then new readings of hardness and roughness were done, and the values were submitted to variance analysis test followed by Tukey test, with 5% of significance. Dentuflex showed the highest initial values for both roughness and hardness, followed by Molloplast-B and Sofreliner MS. After thermocycling, Dentuflex and Sofreliner-MS showed a statistically significant increase in hardness values. After mechanical brushing, Dentuflex showed a decrease and Sofreliner MS an increase in roughness values. After mechanical brushing followed by thermocycling, all materials showed similar roughness values (statistically significant), probably due to the Dentuflex polished surface, the Sofreliner MS abrasion and the remained features of the Molloplast-B / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Page generated in 0.0996 seconds