• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • 21
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 61
  • 61
  • 37
  • 26
  • 19
  • 15
  • 12
  • 11
  • 11
  • 9
  • 9
  • 8
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Soluções higienizadoras de prótese total: avaliação da remoção de biofilme e efeito sobre propriedades da resina acrílica termopolimerizável / Denture cleansing solutions: evaluation of the biofilm removal and effect on properties of heat-polymerized acrylic resin

Amanda Peracini 31 May 2012 (has links)
Este estudo avaliou o efeito de soluções higienizadoras de próteses totais quanto ao controle do biofilme (análise clínica) e à alteração de propriedades da resina acrílica (análise laboratorial). A análise clínica foi realizada em 32 desdentados totais que foram orientados a escovar suas próteses (escova Denture e sabonete líquido) três vezes ao dia e imergí-las (″overnight″) nas soluções: 1) Controle: Água Natural; 2) Pastilha Corega Tabs; 3) Hipoclorito de Sódio 0,5%. Cada solução foi utilizada por 21 dias (03 ciclos de 07 dias). Ao final de cada ciclo, a superfície interna da prótese superior foi evidenciada (vermelho neutro 1%) e fotografada (HX1- Sony). As áreas (total e corada com biofilme) foram medidas (Image Tool 3.00), sendo a porcentagem de biofilme calculada como a relação entre a área do biofilme multiplicado por 100 e área da superfície total da base interna da prótese. Para a análise laboratorial, foram confeccionados 140 corpos de prova de resina acrílica termopolimerizável (Lucitone 550) que foram imersos por 08 horas nas soluções: 1) Controle 1 (sem imersão); 2) Controle 2 (água destilada); 2) Pastilha Corega Tabs; 3) Hipoclorito de sódio 0,5%, simulando uma higienização diária de 03 anos (1095 dias). Antes e após as imersões, os corpos de prova foram avaliados quanto à alteração de cor (Espectrocolorímetro Color Guide 45/0), rugosidade superficial (rugosímetro Surftest SJ-201P) e resistência à flexão (Máquina Universal de Ensaios DL 2000). Os dados de cor foram também calculados de acordo com a National Bureau of Standards (NBS). As análises estatísticas compreenderam o método de equações de estimação generalizadas (GEE) e comparações múltiplas (Teste de Bonferroni - α = 1,67%) para análise clínica; e Análise de Variância (ANOVA) e teste HSD de Tukey (α=0,05) para análise laboratorial. Os resultados clínicos mostraram que a imersão em hipoclorito de sódio 0,5% diminuiu a área coberta por biofilme (8,29 ± 13,26 - B), quando comparado ao controle (18,24 ± 14,91 - A) e à pastilha (18,18 ± 16,62 - A). O hipoclorito (2,75 ± 0,49 - B) e a pastilha (3,01 ± 0,35 - B) provocaram alteração de cor significativamente maior que o controle (0,66 ± 0,29 A), sendo classificadas como perceptível, segundo a NBS. As soluções não alteraram a rugosidade da resina. Houve uma diminuição na resistência à flexão dos grupos pastilha (85,61 ± 10,46 - C) e hipoclorito (82,17 ± 8,47 - C) quando comparados com o controle (sem imersão) (105,4 ± 14,93 - A). O controle (água destilada) apresentou uma redução na resistência à flexão (67,06 ± 11,89 - B). Os achados deste estudo revelaram que a solução de hipoclorito de sódio 0,5% foi a mais efetiva na remoção do biofilme das próteses totais e que ambas as soluções (hipoclorito de sódio 0,5% e peróxido alcalino) não alteraram a rugosidade superficial, porém provocaram alterações de cor classificadas como perceptíveis segundo a NBS, bem como acarretaram uma diminuição da resistência à flexão da resina acrílica termicamente ativada. / This study evaluated the effect of denture cleansers on denture biofilm removal (clinical trial) and changes the properties of acrylic resin (laboratory analysis). A randomized clinical trial was performed in 32 edentulous patients who were instructed to brush their dentures (denture-specific brush and liquid soap) three times a day and to soak them overnight in the solutions: 1) Control: Water; 2) Efervescent Tablet (Corega Tabs); 3) 0.5% Sodium Hypochlorite. Each solution was used for 21 days (03 alternate cycles of 07 days). At the end of each cycle, the inner surfaces of maxillary dentures were disclosed (1% neutral red) and photographed (HX1 Sony). Total and stained biofilm areas were measured (Image Tool 3.00), and the percentage of biofilm calculated as the ratio between the area of the biofilm multiplied by 100 and total surface area of the internal base of the denture. For laboratory analysis, 140 specimens were prepared from heat-polymerized acrylic resin (Lucitone 550) and immersed for 08 hours in the solutions: 1) Control 1 (without immersion); 2) Control 2 (distilled water); 3) Efervescent Tablet Corega Tabs; 4) 0.5% Sodium Hypochlorite, simulating a daily hygiene of 03 years (1095 days). Before and after immersion, specimens were evaluated for color change (portable colorimeter Color Guide 450), surface roughness (Surface Roughness Tester SJ-201P) and flexural strength (universal testing machine DL 2000). Color data were also calculated according the National Bureau of Standards (NBS). Statistical analysis comprised the method of generalized estimating equations (GEE) and multiple comparisons (Bonferroni - α = 1.67%) for clinical analysis, and analysis of variance (ANOVA) and Tukey′s HSD test (α=0.05) for laboratory analysis. Clinical results showed that the immersion in sodium hypochlorite 0.5% reduced the area covered by biofilm (8.3 ± 13.3 - B) compared to the control (18.2 ± 14.9 - A) and tablet (18.2 ± 16.6 - A). Hypochlorite (2.8 ± 0.5 - B) and tablet (3.0 ± 0.4 - B) caused significantly higher color change than the control (0.7 ± 0.3 A); such changes were classified as noticeable, according to NBS. The solutions did not alter the roughness of the resin. There was a decrease in the flexural strength of the groups tablet (85.6 ± 10.5 - C) and hypochlorite (82.2 ± 8.5 - C) compared to control (without immersion) (105.4 ± 14.9 - A). The control (distilled water) showed a reduction in flexural strength (67.1 ± 11.9 - B). The findings revealed that the 0.5% sodium hypochlorite solution was the most effective for biofilm removal from complete dentures and that both solutions (0.5% sodium hypochlorite and alkaline peroxide) did not alter surface roughness, but caused color changes classified as noticeable according to the NBS, and resulted in a decrease of flexural strength of heat-polymerized acrylic resin.
42

Movimentação dos dentes artificiais em próteses totais com diferentes profundidades de palato

Vedovatto, Eduardo [UNESP] 25 May 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-05-25Bitstream added on 2014-06-13T19:24:19Z : No. of bitstreams: 1 vedovatto_e_dr_araca.pdf: 365938 bytes, checksum: bd1dd616abe7c6a4bce474ab109acd1f (MD5) / Demonstração do problema: alterações oclusais sempre ocorrem durante o processamento de próteses totais, entretanto, o deslocamento do dente no sentido ocluso-cervical e sua relação com a profundidade do palato ainda não foi totalmente evidenciada. Objetivos: esse estudo investigou a movimentação dos segundos molares superiores em próteses totais processadas com resina acrílica, com diferentes profundidades de palato e com diferentes materiais de inclusão. Métodos: vinte e oito próteses totais superiores idênticas foram confeccionadas sobre o modelo com palato raso e vinte e oito próteses sobre o modelo com palato profundo. Essas próteses foram divididas em quatro grupos com 14 unidades de acordo com o tipo de palato e o tipo de material de inclusão (gesso ou silicone). Foram demarcados pontos na face distal dos segundos molares e no modelo como referência para a mensuração do deslocamento dos dentes. O deslocamento vertical, horizontal e angular foi verificado através das imagens das próteses com o programa AutoCad em dois momentos: antes da inclusão em mufla e depois da demuflagem (sem a separação do modelo). Os valores foram submetidos ao tratamento estatístico de Kolmogorov- Smirnov e ANOVA com o Tukey e Fisher post hoc test a 5% de significância. Resultados: Os resultados não mostraram diferença estatística significante entre os grupos nos deslocamentos angular (p=0,674) e horizontal (p=0,856). Entretanto, no sentido cervico-oclusal, foi observada diferença entre os grupos (p=0,012) apontando maiores alterações para aqueles cuja inclusão foi realizada com o silicone (E3=0,047 e E2=0,044 cm)em relação ao gesso (E1 = 0,027 e C= 0,026cm). Os grupos com diferentes profundidades de palato não apresentaram diferença estatística significante entre si. Conclusão: esse estudo pôde concluir que o tipo de palato... / Statment of the problem: occlusal changes always occur during the complete dentures, however, the cervical-occlusal displacement of the tooth and its relationship with the plate depth has not yet been well clarified. Purpose: This study investigated the movement of the second molars in complete dentures processed with different palate depths and different materials for inclusion. Methods: Twenty-eight complete maxillary dentures were made on cast with shallow palate and twenty-eight on the cast with deep palate. These grafts were divided into four groups with 14 units according to the type of palate and the type of material for inclusion (gypsum or silicone). Points were marked on the distal face of second molars and in the model for measuring the displacement of the teeth. The vertical displacement, horizontal and angular was verified by the images of the prosthesis with the AutoCad program on two occasions: before inclusion and after deflasking (without the separation of the cast). The values were submitted to statistical Kolmogorov-Smirnov test and ANOVA with Tukey's and Fisher's post hoc test at 5% significance. Results: The results showed no statistically significant difference between groups in the angular displacement (p = 0674) and horizontal (p = 0856). However, the cervical-occlusal direction (vertical displacement), difference was observed between the groups (p = 0012) indicating major changes to those whose inclusion was performed with silicone (E3 = 0047 and E2 = 0044cm) on gypsum (E1 = 0027 and C = 0026cm). The groups with different depths of the palate showed no statistically significant difference between them. Conclusion: This study could conclude that the type of palate did not influence the movement of the second molars, as the method of inclusion of a significant influence on the vertical displacement of the teeth. Clinical... (Complete abstract click electronic access below)
43

Análise através do método dos elementos finitos das tensões desenvolvidas no reborbo alveolar sob as próteses totais com três diferentes conceitos oclusais

Ferreira, Luciano Pedrin Carvalho [UNESP] 19 April 2011 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-04-19Bitstream added on 2014-12-02T11:21:14Z : No. of bitstreams: 1 000676004.pdf: 904634 bytes, checksum: 03b638ed685399c100b20ec02e2eef12 (MD5) / A distribuição das tensões nas estruturas de suporte de tensões decorrentes de forças oclusais aplicadas a próteses totais confeccionadas com diferentes esquemas oclusais não são conhecidos. O objetivo deste estudo foi desenvolver, através do método de elementos finitos bidimensional (MEF-2D), uma analise comparativa e qualitativa das tensões geradas nas estruturas de suporte na região de primeiro molar inferior direito de próteses totais confeccionadas com: (1) Oclusão convencional (OC); (2) Oclusão lingualizada (OL) e, (3) Oclusão monoplana (OP). Os padrões de distribuição de tensões foram observados em quatro condições de reabsorção óssea do rebordo alveolar: (1) alto e convexo; (2) lamina de faca; (3) baixo e convexo e, (4) involuido. Dois materiais de confecção de dentes artificiais foram considerados: resina acrílica e porcelana. Modelos digitais bidimensionais para a aplicação do MEF-2D foram desenvolvidos para as condições propostas. Uma carga vertical de 50N foi aplicada na superfície oclusal do primeiro molar inferior direito. Através do software GID (International Center for Numerical Methods in Engineering, Barcelona, Espanha) foram geradas imagens gráficas de stress (tensões de Von Mises) e de compressão (tensões verticais) nas estruturas de suporte. Neste estudo concluiu-se que: 1. Todos os esquemas oclusais estudados transmitiram stress e compressão para as estruturas de suporte; 2. 15 OC gerou um padrão de distribuição de stress e de compressão em faixas horizontalizadas, enquanto que OL e OP em faixas verticalizadas; 3. OC apresentou um padrão de distribuição de intensidade de stress e de compressão que aumenta da crista do rebordo alveolar para o osso esponjoso, enquanto que OL e OP um padrão que aumenta de vestibular para lingual; 4. Os diferentes níveis de reabsorção do rebordo não interferiram nas intensidades ou padrões... / The strain distribution patterns in the alveolar residual ridge as a consequence of occlusal loads applied in complete dentures constructed with different occlusal schemes are not known. The aim of this study was to develop a comparative and qualitative analysis of the strains generated in the right first molar region of the supporting structures of a mandibular complete denture using the two-dimentional Finite Element Analysis (FEA-2D). Coronal section two-dimensional models were developed reflecting mandibular complete dentures constructed with three different schemes of occlusion, namely conventional (CO), Lingualized (LO) and monoplane (PO). The models also had variations in the contour of the supporting structures, representing four conditions of residual ridge resorption: (1) high, well rounded; (2) knife edge; (3) low, well rounded, and (4) depressed. Two materials of artificial teeth were considered: acrylic resin and porcelain. A vertical load of 50 N was applied onto the occlusal surface of the mandibular right first molar. The software GID (International Center for Numerical Methods in Engineering, Barcelona, Spain) generated images of Von Mises (stress) and vertical (compression or tensile) strains in the FEA-2D models. Within the limitations of this study the following conclusions were drawn: (1) Stress and compression were observed in the supporting structures with all of the studied occlusal schemes; (2) The distribution of stress and compression with CO dentures generated patterns of intensity with the appearance of horizontal layers and, with LO and PO dentures with the appearance of vertical layers; (3) With CO dentures the intensity of stress and compression increased progressively from the crest of the residual ridge to the alveolar bone and, with LO and PO dentures from the buccal to the lingual slope of the ridge; (4) With all of the studied occlusal schemes, neither the...
44

Análise in vitro da citotoxicidade e produção de mediadores inflamatórios por queratinócitos estimulados por adesivos para prótese /

Leite, Andressa Rosa Perin. January 2017 (has links)
Orientador: Ana Carolina Pero / Resumo: Subprodutos oriundos de adesivos utilizados para retenção e estabilidade de próteses totais podem atuar como irritantes quando em contato com a mucosa. O objetivo deste estudo foi avaliar a citotoxicidade e a produção de mediadores inflamatórios por queratinócitos estimulados por diferentes adesivos para próteses totais. Três adesivos disponíveis comercialmente foram testados. Foram obtidos extratos na concentração de 1% para os adesivos tipo creme, pó e fita. Queratinócitos gengivais humanos (NOK-SI) foram cultivados in vitro e expostos por 3, 6 e 24 horas aos extratos. Após este período, a citotoxicidade dos extratos foi avaliada pelo ensaio metil tetrazólio (MTT) e análise da integridade da membrana (liberação de LDH; Kit CytoTox-One) e pela análise da morfologia celular por microscopia eletrônica de varredura (MEV). A produção das citocinas pró-inflamatórias IL-1β, IL-6 e TNF-α foi realizada por meio do ensaio Elisa. A presença de ácido maleico e formaldeído nos adesivos foi verificada por meio de cromatografia gasosa com detector de ionização de chamas. Os resultados obtidos foram submetidos à análise estatística realizada ao nível de significância de 5%. Os adesivos tipo creme (71,6% de viabilidade celular, ligeiramente citotóxico, p=0,000) e pó (75,7%, não citotóxico, p=0,002) alteraram significativamente a viabilidade celular quando comparados ao controle negativo no período 6 horas. Não foram observadas diferenças significativas entre os adesivos e o controle negativ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: ubproducts from denture adhesives used to improve retention and stability of these dentures, in contact with the oral mucosa, can act as an irritant. The purpose of this study was to evaluate the cytotoxicity and production of inflammatory mediators by keratinocytes stimulated by different denture adhesives. Three commercially available adhesives were tested (Ultra Corega cream, Corega powder Fixador Ultra and Corega pad). Extracts were obtained from the adhesive cream, powder and strip at 1% after 24 hours of exposure in DMEM culture medium. Human gingival keratinocytes (NOK-SI) were grown in vitro and exposed for 3, 6 and 24 hours to extracts. After this period, the cytotoxicity of the extracts was evaluated by methyl tetrazolium assay (MTT) and analysis of membrane integrity (LDH realese; KIT Cytotox-One) and by analysis of cell morphology by scanning electron microscopy (SEM). It was also evaluated the production of IL-1, IL-6 and TNF-α using the Elisa assay. It was also evaluated the presence of maleic acid and formaldehyde in adhesives by means of Gas Chromatography and Flame Ionization Detector. The results were analyzed statistically with a significance level of 5%. Cream (71.6%, slightly cytotoxic, p=0.000) and powder denture adhesives (75.7%, non-cytotoxic, p=0.002) significantly altered cell viability when compared to the negative control at 6h. No significant differences were observed between the adhesives and the negative control (p>0.05) when the analysis of membrane integrity assay was performed. The cellular morphology of keratinocytes exposed to adhesive eluates was similar to control. Greater IL-6 cytokine release was observed for cream and powder denture adhesives at 6h and 24h (p<0.05). IL-1β release from strip was higher at 3 hours when compared to the control (p = 0.016). The presence of maleic...(Complete abstract electronic access below) / Doutor
45

Análise através do método dos elementos finitos das tensões desenvolvidas no reborbo alveolar sob as próteses totais com três diferentes conceitos oclusais /

Ferreira, Luciano Pedrin Carvalho. January 2011 (has links)
Resumo: A distribuição das tensões nas estruturas de suporte de tensões decorrentes de forças oclusais aplicadas a próteses totais confeccionadas com diferentes esquemas oclusais não são conhecidos. O objetivo deste estudo foi desenvolver, através do método de elementos finitos bidimensional (MEF-2D), uma analise comparativa e qualitativa das tensões geradas nas estruturas de suporte na região de primeiro molar inferior direito de próteses totais confeccionadas com: (1) Oclusão convencional (OC); (2) Oclusão lingualizada (OL) e, (3) Oclusão monoplana (OP). Os padrões de distribuição de tensões foram observados em quatro condições de reabsorção óssea do rebordo alveolar: (1) alto e convexo; (2) lamina de faca; (3) baixo e convexo e, (4) involuido. Dois materiais de confecção de dentes artificiais foram considerados: resina acrílica e porcelana. Modelos digitais bidimensionais para a aplicação do MEF-2D foram desenvolvidos para as condições propostas. Uma carga vertical de 50N foi aplicada na superfície oclusal do primeiro molar inferior direito. Através do software GID (International Center for Numerical Methods in Engineering, Barcelona, Espanha) foram geradas imagens gráficas de stress (tensões de Von Mises) e de compressão (tensões verticais) nas estruturas de suporte. Neste estudo concluiu-se que: 1. Todos os esquemas oclusais estudados transmitiram stress e compressão para as estruturas de suporte; 2. 15 OC gerou um padrão de distribuição de stress e de compressão em faixas horizontalizadas, enquanto que OL e OP em faixas verticalizadas; 3. OC apresentou um padrão de distribuição de intensidade de stress e de compressão que aumenta da crista do rebordo alveolar para o osso esponjoso, enquanto que OL e OP um padrão que aumenta de vestibular para lingual; 4. Os diferentes níveis de reabsorção do rebordo não interferiram nas intensidades ou padrões... / Abstract: The strain distribution patterns in the alveolar residual ridge as a consequence of occlusal loads applied in complete dentures constructed with different occlusal schemes are not known. The aim of this study was to develop a comparative and qualitative analysis of the strains generated in the right first molar region of the supporting structures of a mandibular complete denture using the two-dimentional Finite Element Analysis (FEA-2D). Coronal section two-dimensional models were developed reflecting mandibular complete dentures constructed with three different schemes of occlusion, namely conventional (CO), Lingualized (LO) and monoplane (PO). The models also had variations in the contour of the supporting structures, representing four conditions of residual ridge resorption: (1) high, well rounded; (2) knife edge; (3) low, well rounded, and (4) depressed. Two materials of artificial teeth were considered: acrylic resin and porcelain. A vertical load of 50 N was applied onto the occlusal surface of the mandibular right first molar. The software GID (International Center for Numerical Methods in Engineering, Barcelona, Spain) generated images of Von Mises (stress) and vertical (compression or tensile) strains in the FEA-2D models. Within the limitations of this study the following conclusions were drawn: (1) Stress and compression were observed in the supporting structures with all of the studied occlusal schemes; (2) The distribution of stress and compression with CO dentures generated patterns of intensity with the appearance of horizontal layers and, with LO and PO dentures with the appearance of vertical layers; (3) With CO dentures the intensity of stress and compression increased progressively from the crest of the residual ridge to the alveolar bone and, with LO and PO dentures from the buccal to the lingual slope of the ridge; (4) With all of the studied occlusal schemes, neither the... / Orientador: Sergio Sualdini Nogueira / Coorientador: Osvaldo Luís Manzoli / Banca: João Neudenir Arioli Filho / Banca: José Claudio Martins Segalla / Banca: Valdir Antonio Muglia / Banca Claudia Helena Lovato da Silva / Doutor
46

Movimentação dental linear em protese total superior e inferior em função de diferentes tecnicas de inclusão / Linear dental movement of maxillary and mandibular complete dentures in function of enclosing techniques

Joia, Fabio Alves 19 August 2005 (has links)
Orientador: Celia Marisa Rizzatti Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-05T02:25:21Z (GMT). No. of bitstreams: 1 Joia_FabioAlves_M.pdf: 5977969 bytes, checksum: e66707336fade444f0c8a18dedfa11c1 (MD5) Previous issue date: 2005 / Resumo: O presente estudo avaliou a movimentação dental linear em prótese total superior e inferior em função de diferentes técnicas de inclusão. Quarenta pares do conjunto modelo-base de prova em cera, com os dentes artificiais montados, das arcadas superior e inferior, foram distribuídos ao acaso em quatro grupos de 10 pares cada, recebendo os seguintes tratamentos: Grupo A ¿ Inclusão em mufla monomaxilar de Cloreto de Polivinila (PVC) com muralha de gesso Tipo III; Grupo B ¿ Inclusão em mufla de PVC bimaxilar com muralha de silicone para laboratório, sem retenção nos dentes artificiais; Grupo C ¿ Inclusão em mufla de PVC bimaxilar com muralha de gesso Tipo III; Grupo D ¿ Inclusão em mufla de PVC bimaxilar com muralha de silicone para laboratório, com retenção nos dentes artificiais. Nos quatro grupos a resina acrílica utilizada na polimerização das próteses foi a resina termicamente ativada por energia de microondas, sendo o ciclo de polimerização realizado com um tempo de 20 minutos a 20% da potência, mais um ciclo de 5 minutos a 60% da potência do forno de microondas de 960 W de potência máxima, sem intervalo entre os ciclos. Sete distâncias em arco, duas distâncias diagonais e três distâncias transversais foram mensuradas, por um único avaliador, antes da inclusão e após a polimerização da base, com auxílio do microscópio mensurador linear (Olympus STM), com precisão de 0,0005 milímetro. Os dados obtidos foram submetidos à análise estatística pelo método não paramétrico de Kruskal-Wallis (p<0,05) e pelas comparações múltiplas pelo método de Dunn. A análise demonstrou diferenças estatisticamente significantes para três medidas em arco, as duas distâncias diagonais e as três distâncias transversais, entre o grupo de inclusão monomaxilar (A) e pelo menos um grupo de inclusão bimaxilar (B, C ou D), sendo os menores valores de alterações dentais lineares encontrados, em sua maioria, nos grupos de inclusão bimaxilar com muralha de silicone (B e D). Diante das condições experimentais presentes, foi possível concluir que o método de inclusão bimaxilar é mais viável quando associado ao uso da muralha de silicone com ou sem retenções nos dentes artificiais, em relação à inclusão monomaxilar / Abstract: The present study evaluated linear dental movement in maxillary and mandibular complete denture using different flasking technics. Forty pairs of the joint model-wax base, of maxillary and mandibular arches, with mounted artificial teeth, had been randomized distributed into four groups of 10 pairs each, receiving the following treatments: GA: invested in conventional flask, in a total gypsum environment; GB: invested in special flask for simultaneous polymerization using silicone and gypsum base; GC: invested in special flask for simultaneous polymerization of maxillary and mandibular prostheses in a total gypsum environment; GD: invested in special flask for simultaneous polymerization using silicone, gypsum base, and retentions on artificial teeth. The prostheses were processed with heat-polymerized acrylic resin for microwaves energy polymerization, during 20 minutes at 20% of the power, plus an additional cycle of 5 minutes at 60% of the power, of a microwave oven of 960W maximum power, without interval between the cycles. Seven arch distances, two diagonal distances and three transversal distances had been measured, by an only appraiser, before flasking and after processing, with aid of a measuring microscope (Olympus, model STM), with 0.0005 millimeter precision. Data had been statistically analyzed by Kruskal-Wallis test (p<0.05) and Dunn test. It demonstrated statistically significant differences in three arch distances, two diagonal distances and three transversal distances, between group A (conventional flask) and at least one group of bimaxilar flask (B, C or D), with the lesser values of linear dental alterations been found, in its majority, at bimaxilar flask with silicone and gypsum base groups (B and D). Ahead of the experimental conditions gifts, it was possible to conclude that bimaxilar flasking method is more viable when associate to the use of the silicone and gypsum base with or without retention in artificial teeth, when compared with conventional flasking procedure / Mestrado / Protese Dental / Mestre em Clínica Odontológica
47

Avaliações eletrognatograficas e eletromiograficas computadorizadas em pacientes submetidas a terapia com aparelhos oclusais planos e reabilitados com proteses totais duplas com variação na dimensão vertical de oclusão / Computerized elecrtomyography and electrognatography evaluations in patients submetted to occlusal appliance therapy and total prosthesis rehabilitation with occlusal vertical dimension variance

Casselli, Henrique 12 July 2005 (has links)
Orientador: Wilkens Aurelio Buarque e Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-05T13:29:55Z (GMT). No. of bitstreams: 1 Casselli_Henrique_D.pdf: 2650185 bytes, checksum: fe19e02a023374e9a2652ef6dc7d8aad (MD5) Previous issue date: 2005 / Resumo: Este estudo teve como objetivo investigar por meio de avaliações eletrognatográficas e eletromiográficas computadorizadas o padrão de movimentação mandibular e a atividade elétrica dos músculos temporal anterior, masseter e supra-hioideos de 16 pacientes sem sintomas de alterações funcionais do sistema estomatognático, reabilitados com próteses totais duplas e com variação da dimensão vertical de oclusão (DVO). Inicialmente, todos os pacientes foram submetidos às avaliações supra-citadas e à utilização, por trinta dias, de um aparelho intra-oral de cobertura oclusal plana sobre a prótese usual superior. Ao término desse período foi realizado o segundo conjunto de avaliações e então os pacientes foram reabilitados com próteses novas preservando a existência de um espaço funcional livre de 3mm. Após 60 dias de uso das novas próteses realizou-se o terceiro conjunto de avaliações, sendo então suprimido o espaço funcional livre obtendo-se um aumento da dimensão vertical de oclusão. As dentaduras inferiores modificadas foram utilizadas por mais 60 dias, ao término dos quais se realizou o quarto e último conjunto de avaliações. Os dados coletados foram submetidos à análise de variância pelo Anova e Teste de Tukey ao nível de significância 5% e também pela análise estatística não-paramétrica pelo Teste de Friedman. Os resultados obtidos revelaram que, para a situação de repouso, houve diferenças estatísticas significativas entre a primeira e a segunda avaliação para os músculos masseter e temporal anterior. Para a situação de fechamento isométrico com resistência, houve diferenças significativas para os músculos masseteres considerando as duas primeiras avaliações em relação às duas últimas, e para os músculos digástricos considerando as três primeiras em relação à quarta avaliação. Para a situação de apertamento, tais diferenças ocorreram para o músculo masseter comparando-se a primeira avaliação em relação às duas últimas. Considerando-se os resultados pertinentes às avaliações eletrognatográficas observou-se uma significativa diminuição do espaço funcional livre quando comparou-se a primeira em relação a última avaliação e uma significativa diminuição da movimentação póstero-anterior quando comparou-se a primeira avaliação em relação à segunda. Para a situação de abertura e fechamento não observou-se diferenças significativas entre avaliações considerando-se qualquer variável estudada. Concluímos que, ao final do tratamento o método proposto favoreceu o estabelecimento de uma dimensão vertical compatível com a manifestação da natureza específica de cada músculo estudado quanto à atividade elétrica, dentro das condições clínicas da amostra estudada; a presença de um espaço funcional livre ao término do tratamento, concomitantemente ao estabelecimento de valores eletromiográficos específicos frente a uma relação maxilomandibular horizontal e vertical otimizada, vem comprovar a importância de sua existência na manutenção do equilíbrio do sistema mastigatório pois admite o estabelecimento da posição de repouso mandibular / Abstract: The purpose of this study was to evaluate by means of computerized electrognatography and electromyography, the mandibular movements and the activity of masseter, anterior temporal and digastric bilateral muscles in sixteen patients without symptoms of stomatognatic functional disorders, submitted to complete dentures rehabilitation with occlusal vertical dimension. First the patients were submitted to above evaluations and utilization, for thirty days, of an intra-oral plane occlusal aplliance over the superior usual prosthesis. After this period the second global evaluations was realized, when the patients received new upper and lower complete dentures with a 3-mm of interocclusal rest space. After sixty days using the new prosthesis, the third global evaluations was performed and the interocclusal rest space was suppressed by an increase in the occlusal vertical dimension. The lower modified prosthesis were used for further sixty days when the forth and last global evaluations analysis was performed. Data were submitted to variance analysis by ANOVA and parametric Tukey Test at the 5% confidence level, as non-parametric Friedman Test at the 5% confidence level, depending the variable studied. Considering electromyografic analysis, the results showed a significant increase in the electromyographic activity for the anterior temporal and masseter muscles between the initial and second evaluation periods in the rest position. For resistance closing situation, masseter muscles showed a significant increase in the electrical activity at the third and last periods of evaluation, while for the digastric muscles, a decrease in the electrical activity in the last period was verified. Considering electrognatografic analysis a significant decrease of the free way space was observed between last and first values periods, as a significant decrease of posterior-anterior movement between the second and first values periods. For maximal opening and closing situation no significant differences were observed considering any variable studied. Considering electrical activity, at the end of the treatment the purposed method established a vertical dimension compatible with a specific nature manifestation of which studied muscle; the free way space presence in the last period, concomitant to electromyography specific values establishment considering an optimized vertical and horizontal maxilo-mandibular relation, confirm the importance of its existence in the maintenance of masticatory equilibrium, admitting the mandibular rest position establishment / Doutorado / Protese Dental / Doutor em Clínica Odontológica
48

Influencia dos tipos de contensão de mufla e do tempo pos-prensagem na movimentação de dentes em protese total / Influence of the flask contention methods and post-pressing time on the tooth movement in complete denture

Negreiros, Wagner Araujo de 14 December 2006 (has links)
Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T08:12:10Z (GMT). No. of bitstreams: 1 Negreiros_WagnerAraujode_M.pdf: 1023466 bytes, checksum: 7bb8b4a8d3aafd26ecacaad6cdd6c73f (MD5) Previous issue date: 2006 / Resumo: A movimentação de dentes artificiais é um fenômeno frequentemente observado, em maior ou em menor grau, após o processamento das próteses totais. Diversos são os fatores implicados e essa alteração pode desequilibrar posições oclusais inicialmente planejadas. Este trabalho verificou o efeito dos tipos de contensão de muflas e do tempo pós-prensagem na movimentação de dentes em próteses totais, confeccionadas com 2 marcas de resina acrílica: Clássico (Clássico Produtos Odontológicos, SP, Brasil) e QC-20 (Dentsply Indústria e Comércio Ltda., Petrópolis, RJ). Foram confeccionadas 40 próteses totais superiores distribuídas aleatoriamente em 8 grupos (n=5) de acordo com o tipo de contensão (metálico convencional e RS) e com o tempo pós-prensagem (imediato e após 6 horas). Pinos referenciais metálicos foram posicionados na borda incisal dos incisivos centrais, na cúspide vestibular do primeiro pré-molar e cúspide mésio-vestibular dos segundos molares. As distâncias transversais I-I (incisivo a incisivo), PM-PM (pré-molar a pré-molar) e M-M (molar a molar), e ântero-posteriores ID-MD (incisivo direito a molar direito) e IE-ME (incisivo esquerdo e molar esquerdo) foram mensuradas antes e após o processamento, utilizando microscópio comparador (Olympus Optical Co., Tokyo, Japan), com precisão de 0,0005mm. As resinas acrílicas Clássico e QC-20 foram proporcionadas e manipuladas de acordo com as instruções dos fabricantes e submetidas aos ciclos de polimerização em água a 74ºC por 9 horas e em água em ebulição por 20 minutos, respectivamente. Os dados coletados foram transformados segundo o arco seno da raiz de x/100 e submetidos à análise de variância. As médias percentuais foram comparadas pelo teste de Tukey em nível de 5% de significância. As interações resina-tipo de contensão e resina-tempo pós-prensagem, independente dos demais fatores não mostraram diferença estatística significativa no percentual médio de movimentação dental; houve diferença estatística significativa na distância I-I para a contensão convencional na pós-prensagem imediata, com maior valor para a resina Clássico. Na pós-prensagem 6 horas não houve diferença estatística significativa entre as resinas; houve diferença estatística significativa na distância I-I para o sistema RS na pós-prensagem imediata, com maior valor para a resina Clássico. Na pós-prensagem 6 horas, as distâncias I-I e IE-ME foram com diferença estatística significativa, sendo maior para a resina Clássico na distância I-I e menor na distância IE-ME; somente a distância I-I apresentou diferença estatística significativa para a resina Clássico com grampo convencional, sendo o maior valor no tempo imediato; o percentual médio de deslocamento dental para as resinas Clássico e QC-20 com o sistema RS foi sem diferença estatística significativa entre os tempos pós-prensagem. O autor concluiu que as alterações percentuais não foram uniformes sofrendo influência de resinas, tempo pós-prensagem e distância entre dentes / Abstract: Tooth displacement is a common phenomenon observed after complete denture processing. Some factors may be involved and this alteration can modify the proposed occlusal scheme. This study verified the effect of the flask pressure methods and post-pressing time prior to polymerization on tooth movement in maxillary complete dentures fabricated with Classico and QC-20 heat-cured acrylic resins. Forty maxillary complete dentures were fabricated and randomly assigned into 8 groups (n=5), according to the flask pressure methods (conventional and RS system) and the post-pressing time (immediate and after 6 hours). Metallic referential pins were placed in the incisal border of the central incisors, vestibular cusp of the first premolars and the mesio-vestibular cusp of the second molars. The I-I (incisor to incisor), PM-PM (premolar to premolar), M-M (molar to molar) transversal distances and RI-RM (right incisor to right molar) and LI-LM (left incisor to left molar) anteroposterior distances were measured before and after complete dentures processing with a linear Olympus optical microscope, with an accuracy of 0,0005mm. Classico and QC-20 acrylic resins were proportioned and manipulated following the manufacturer¿s directions, and submitted to the conventional water bath at 74ºC for 9 hours or to water boiled bath for 20 minutes curings. Collected data in percent were transformed in arch seno of the root of x/100 and submitted to the variance analysis and Tukey test at 5% of significance. The resin-flask pressure methods and resin-post pressing time interactions, independently of other factor showed no statistically significant difference in the mean percentages of dental displacement; there was statistically significant difference in the I-I distance for conventional clamp in immediate post-pressing, with greater value for Classico resin. In the 6-hour post-pressing there was no statistically significant difference between resins; there was statistically significant difference in the I-I distance for RS system in the immediate post-pressing, with greater value for Classico resin. In the 6-hour post-pressing, the I-I and IE-ME distances were with statistically significant difference, being greater for Classico resin in I-I distance and smaller in IE-ME distance; only the I-I distance showed statistically significant difference for Classico resin with conventional clamp, being greater for the immediate post-pressing time; the mean percentages in the tooth displacement for Classico and QC-20 resins with the RS system was without statistically significant difference between post-pressing times. The author concluded that the percentage changes were not uniform being influenced by resins, post-pressing time and distance among teeth / Mestrado / Protese Dental / Mestre em Clínica Odontológica
49

Avaliação comparativa da absorção, solubilidade e dureza em reembasadores resilientes submetidos a termociclagem / Comparative evaluation of two permanent denture soft liners in water sorption, solubility and hardness by thermal cycling

Hermann, Caio 23 March 2007 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T19:35:25Z (GMT). No. of bitstreams: 1 Hermann_Caio_D.pdf: 888674 bytes, checksum: d3703c6f41944c7eb987d5764bbec2b3 (MD5) Previous issue date: 2007 / Resumo: Este trabalho teve como objetivo avaliar comparativamente o efeito do envelhecimento por termociclagem na absorção, solubilidade e dureza em dois materiais reembasadores resilientes considerados de longa duração, um à base de silicone autopolimerizável (Sofreliner MS) e outro à base de resina acrílica termopolimerizável (Super-soft). As amostras foram confeccionadas a partir de matrizes metálicas com formato circular medindo 45 mm de diâmetro X 1 mm de espessura (absorção e solubilidade) e 45 mm de diâmetro X 3 mm espessura (dureza). As matrizes foram incluídas em mufla metálica, obtendo um molde impresso no silicone posteriormente preenchido com os materiais resilientes. Foram confeccionadas 40 amostras, metade para mensuração de absorção de água e solubilidade e outra metade para dureza Shore A, mensurada num durômetro GS ¿ 709 Teclock, Osaka, Japão. Em seguida as amostras foram submetidas ao ensaio de termociclagem numa máquina MSCT ¿ 3 PLUS, regulada em 2.000 ciclos com banhos alternados de 60 segundos a 5±1oC e 55±1oC. Após os ensaios, foram efetuadas novas leituras de dureza Shore A e avaliação quanto à absorção de água e solubilidade. Os valores obtidos foram submetidos ao teste de Shapiro ¿ Wilks para avaliação da normalidade dos dados, seguida da aplicação do teste t de Student. Os resultados de absorção de água e solubilidade apresentaram diferença estatisticamente significante para ambos os materiais, sendo respectivamente 2,69 ± 0,16% e 1,59 ± 0,24% para o material Super ¿ soft e 1,41 ± 0,21% e 0,01 ± 0,1% para o Sofreliner MS (p<0,05). Para o ensaio de dureza Shore A, os valores apresentados antes e após termociclagem foram de 64 e 30 unidades pelos materiais Super ¿ soft e Sofreliner MS, respectivamente, não diferindo estatisticamente considerando os materiais isoladamente (p>0,05). Comparando cada material separadamente antes e após a termociclagem, ambos apresentaram diferença estatisticamente significante entre si (p<0,05). O material Sofreliner MS apresentou menores valores de absorção de água, solubilidade e dureza Shore A. Desse modo, concluiu-se dentro dos limites deste estudo que aparentemente este material deva apresentar melhor comportamento quando utilizado clinicamente / Abstract: The aim of this study was to evaluate the effect of thermocycling on sorption, solubility and Shore A hardness of two resilient definitive lining materials: 1) auto-polymerized silicone base (Sofreliner MS); and 2) heat-polymerized plasticized acrylic resin (Super - soft). To prepare the samples, twenty aluminium matrixes were made (ten for sorption and solubility and ten for Shore A hardness) placed in a flask order to obtain a cast pressed mold, and then filled with resilient lining materials, handled according to the manufacturer¿s directions. The hardness samples were submitted for readings in a Shore A durometer (GS ¿ 709 Teclock, Osaka, Japan). After the readings, the samples were submitted to thermal cycling treatment in a thermal cycler machine (MSCT ¿ 3 PLUS) for 2.000 cycles at temperatures ranging from 5±1oC to 55±1oC and a 60-second dwell time. After thermal cycling new readings of hardness were done, and the values of sorption and solubility calculated by Kasanji & Watkinson equation. The values were submitted to Shapiro ¿ Wilks analysis followed by Student test, with 5% of significance. Sorption and solubility showed statistical significance for both materials (2,69 ± 0,16 and 1,59 ± 0,24 for Super ¿ soft and 1,41 ± 0,21 and 0,01 ± 0,1 for Sofreliner MS) (p<0,05). For Shore A hardness the thermal cycling showed no effect for both materials (64 for Super ¿ soft and 30 for Sofreliner MS) (p>0,05). Sofreliner MS showed the lower values for sorption, solubility and Shore A hardness. Withing the limitations of this in vitro study Sofreliner MS showed best properties / Doutorado / Protese Dental / Doutor em Clínica Odontológica
50

Características da deglutição em idosos submetidos a diferentes estratégias de reabilitação oral protética / Characteristics of swallowing in elderly individuals submitted to different strategies for prosthetic oral rehabilitation

Tatiane Totta 29 August 2008 (has links)
O objetivo deste estudo foi verificar se diferentes estratégias de reabilitação oral protética acarretam modificações nos achados clínicos e videoendoscópicos da deglutição em idosos. Métodos: participaram da pesquisa 42 idosos saudáveis com desempenho cognitivo adequado (26 mulheres e 16 homens, 60-82 anos), desdentados totais ou parciais, separados em três grupos segundo avaliação odontológica prévia: próteses parciais fixas ou removíveis (PP) (n = 15); próteses totais removíveis superior e inferior (PTR) (n = 15); e próteses totais removíveis superior e próteses totais fixas implanto-suportadas inferior (PTFIS) (n = 12). O grupo controle foi constituído de 15 idosos dentados totais (DT) (6 homens e 9 mulheres, 60-80 anos) que atenderam aos critérios de inclusão na amostra. Avaliaram-se as consistências sólida (pão), pastosa (10 ml) e líquida (10 ml). Para a avaliação clínica propôs-se uma classificação da gravidade da disfunção da deglutição orofaríngea, distribuída em cinco níveis. Na avaliação instrumental, da qual participaram 37 idosos, realizou-se teste de sensibilidade laringofaríngea, e classificou-se a gravidade do distúrbio de deglutição, de acordo com a escala de comprometimento funcional (gravidade) da deglutição após a VED, ordenada em graus de 0 à III. Para a análise comparativa entre os grupos em ambas as avaliações, e para comparação entre os níveis de comprometimento da deglutição, utilizou-se o Teste de Kruskal-Wallis, adotando-se o nível de significância inferior a 5%. Resultados: Os achados clínicos e videoendoscópicos da deglutição demonstraram não haver diferenças estatisticamente significantes (p>0,05) entre os grupos estudados, nas três consistências ofertadas. Especificamente na avaliação clínica, para a consistência pastosa o grupo DT apresentou maior prevalência de deglutição funcional, enquanto a disfagia orofaríngea moderada foi o padrão de maior ocorrência no grupo PTR (p<0,01). Para o sólido, os grupos de reabilitação oral demonstraram predomínio das disfagias (p<0,01) em relação à deglutição normal e funcional, sendo predominante a disfagia orofaríngea moderada para o grupo PTR (p<0,01). A VED demonstrou, para todos os grupos, que na deglutição de líquido houve distribuição semelhante entre os níveis, enquanto nas consistências sólida e pastosa encontrou-se predomínio de disfagia (p<0,01), havendo maior ocorrência da disfagia orofaríngea moderada (p<0,01) para o grupo PTR na consistência pastosa. O teste de sensibilidade laringofaríngea demonstrou que 19 (51,35%) indivíduos apresentaram alteração da sensibilidade, sendo 6 (40%) do grupo PP, 7 (63,63%) do grupo PTR e 6 (54,54%) do grupo PTFIS. Conclusão: Idosos saudáveis podem apresentar diferentes níveis de deglutição, havendo maior ocorrência de disfagia orofaríngea para as consistências pastosa e sólida, sendo que diferentes estratégias de reabilitação oral não resultam em modificações no padrão de deglutição desses sujeitos. / This study investigated if different strategies of prosthetic oral rehabilitation cause changes in the clinical and videoendoscopic findings of swallowing in elderly individuals. Methods: The study was conducted on 42 healthy elderly subjects with adequate cognitive performance (26 women and 16 men, 60-82 years), completely or partially edentulous, divided in three groups according to the previous dental evaluation: wearing fixed or removable partial dentures (RPD) (n = 15); wearing maxillary and mandibular removable complete dentures (RCD) (n =15); and wearing maxillary removable complete dentures and mandibular implant-supported fixed complete dentures (ISFCD) (n = 12). The control group was composed of 15 completely dentate elderly individuals (DT) (6 men and 9 women, 60-80 years) who met the inclusion criteria. Solid (bread), paste (10 ml) and liquid (10 ml) food textures were analyzed. Clinical evaluation was performed by classification of the severity of dysfunction of oropharyngeal swallowing, divided in five scores. The instrumental evaluation was applied to 37 elderly individuals, comprising the laryngopharyngeal sensitivity test for classification of the severity of the swallowing disorder according to the scale of functional impairment (severity) of swallowing after the VED, divided in scores 0 to III. Comparison between groups in both evaluations and between the scores of impairment of swallowing was performed using the Kruskal-Wallis test, at a significance level below 5%. Results: The clinical and videoendoscopic findings of swallowing revealed no statistically significant differences (p>0.05) between the study groups, for the three textures. Specifically with regard to the clinical evaluation for the paste texture, the DT group exhibited higher prevalence of functional swallowing, while the RCD group presented higher occurrence of moderate oropharyngeal dysphagia (p<0.01). With regard to the solid texture, the groups of oral rehabilitation presented predominance of dysphagia (p<0.01) in relation to normal and functional swallowing, with predominance of moderate oropharyngeal dysphagia for the RCD group (p<0.01). The VED demonstrated, for all groups, that the swallowing of liquid had a similar distribution between scores, while for the solid and paste textures there was predominance of dysphagia (p<0.01), with higher occurrence of moderate oropharyngeal dysphagia (p<0.01) for the RCD group for the paste texture. The laryngopharyngeal sensitivity test demonstrated that 19 (51.35%) individuals presented alterations in sensitivity, being 6 (40%) in the RPD group, 7 (63.63%) in the RCD group and 6 (54.54%) in the ISFCD group. Conclusion: Healthy elderly individuals may present different scores of swallowing, with higher occurrence of oropharyngeal dysphagia for the paste and solid textures; different strategies of oral rehabilitation did not cause changes in the pattern of swallowing of these individuals.

Page generated in 0.0886 seconds