Avaliação do grau do dano das estruturas do subsolo de três edifícios situados na Região Metropolitana do Recife / Evaluation of the degree of damage in the subsoil structures of three buildings situated in the Region Metropolitan of Recife/PE

Sérgio Pereira Pinto Lemos 20 April 2006 (has links)
Procurando conhecer o grau de deterioração precoce das estruturas de concreto armado dos edifícios residenciais da Região Metropolitana da Cidade do Recife, Estado de Pernambuco, este trabalho visa, utilizando um método de quantificação dos danos e o uso de ensaios, avaliar as patologias das estruturas estudadas. Estudou-se três edifícios residenciais (ER), com semelhante padrão de construção, idades construtivas aproximadas e inseridos em diferentes classes de agressividade ambiental. Foi realizada inspeção visual e ensaios em amostras dos pilares, vigas, lajes e reservatório inferior do subsolo dos três edifícios. Após análise dos três edifícios, verificou-se que o caso ER 1, localizado em classe ambiental de agressividade forte (III), a mais agredida pelo meio ambiente, e o estudo de caso ER 2, localizado a uma distância significativa da orla marinha em Classe de Agressividade Ambiental II, apresentaram grau de deterioração media (GD) de 36,98 e 31,23 respectivamente, com recomendação para inspeção periódica e intervenção a médio prazo. Já o estudo de caso ER 3, que está localizado dentro da uma classe de agressividade forte (III), em orla marinha, porém com barreiras de proteção que evitam a incidência direta da névoa salina, encontra-se com alto grau de deterioração (GD = 103,94), sugerindo uma intervenção imediata com riscos de colapso / This work aims to evaluate the pathology of residential buildings structures located at the Metropolitan Region of Recife, Brazil using the quantification of damages to measure the degree of early deterioration of reinforced concrete. Three residential buildings (RB) with similar construction standards were studied. All buildings have approximate age and are inserted into environmental aggressiveness distinct. A visual inspection took place as well as a laboratorial sample analysis of their pillars, beams and underground water reservatories. It was verified that the RB1 case, located at a high environmental aggressiveness class (III), and the RB2 case, located significatively far from the sea and classified with a moderate environmental aggressiveness class (II), both presented a medium degree of deterioration (GDE). For both buildings it is suggested a periodic inspection recommendation and a medium term intervention (GD 1 = 36,98 ; GD 2 = 31,23). The third case (RB3), located at a high environmental aggressiveness class (III) and seafront with protection barriers, presented a high degree of deterioration (GD 3=103,94). It is suggested for RB3 an immediate intervention with collapse risks
2

Análise de laudos emitidos sobre "prédios tipo caixão" da região metropolitana de Recife : causas apontadas para os desabamentos e interdições

Mauro José Araújo Campelo de Mélo 17 October 2007 (has links)
Nos últimos 20 anos, alguns municípios da Região Metropolitana do Recife - PE, têm sido afetados por problemas diversos em obras de Engenharia Civil, contabilizando, inclusive, óbitos. O mais grave desses problemas, dado ao número de edificações envolvidas, diz respeito aos prédios tipo caixão; alguns ruíram e vários foram e estão interditados e houve desinterdição. O objetivo geral da presente dissertação é analisar os laudos técnicos produzidos sobre os prédios tipo caixão, construídos nos Municípios de Olinda, Jaboatão dos Guararapes e Paulista - PE, tendo como meta estudar as causas apontadas para os desabamentos e interdições das referidas edificações. De um modo geral, pode-se apontar como causas dos desabamentos, as seguintes: falhas ou insuficiência de projeto (31,4%); baixa qualidade ou inadequação dos materiais (17,1%); falhas ou vícios de construção (34,4%); causas ambientais (17,1%). Já para as interdições: falhas ou insuficiência de projeto (21,4%); baixa qualidade ou inadequação dos materiais (3,5%); falhas ou vícios de construção (2,8%); uso inadequado ou falta de manutenção (26,0%); causas ambientais (4,3%); outras causas (42,0%). As desinterdições ocorreram quando foram atendidas as restrições feitas pela Defesa Civil de cada município, e que envolviam problemas estruturais e de habitabilidade. Constata-se também uma atuação inadequada dos órgãos de fiscalização e a ausência de padronização dos laudos e de um modelo técnico para a recuperação adequada dessas construções. Espera-se ter contribuído, através da análise e sistematização dos dados contidos nos laudos estudados, para trabalhos futuros, visando o desenvolvimento de tecnologia capaz de equacionar a situação dos referidos imóveis / In the past 20 years, some cities of the Metropolitan Area of Recife - PE, have been affected by several problems in Civil Engineering constructions, some of which resulted in human deaths. The most serious of these problems, given the number of constructions involved, concerns the specific building called box; some of the buildings did fall and several others have been interdicted. Just a few of them were cleared and the majority of them continue to be interdicted. The general objective of the present dissertation is to analyze the awards produced on the building type box, built in the cities of Olinda, Jaboatão dos Guararapes and Paulista. Its goal is to study the causes pointed out as responsible for the collapse and interdictions of those constructions. In a general way, it can be pointed out as causes of the collapses, the following ones: imperfections or insufficiency of project (31.4%); low quality or inadequacies of the materials (17.1%); construction mistakes (34.4%); environmental causes (17.1%). For the interdictions: imperfections or insufficiencies of project (21.4%); low quality or inadequacies of the materials (3.5%); construction mistakes (2.8%); inadequate use or lack of maintenance (26.0%); environmental causes (4.3%); other causes (42.0%). The buildings were cleared when the conditions made by the Civil Defense of each city were met; they involved structural problems and habitability. Its also evident an inadequate performance of the inspection agencies and the lack of standardization of the awards, as well as the absence of a model for the adequate recovery of these constructions. One expects to have contributed, through the analysis and systematization of the data contained in the studied awards, for future works, aiming at the development of technology capable to equate the situation of the cited real estates.
3

Análise de laudos emitidos sobre "prédios tipo caixão" da região metropolitana de Recife : causas apontadas para os desabamentos e interdições

Mélo, Mauro José Araújo Campelo de 17 October 2007 (has links)
Made available in DSpace on 2017-06-01T17:57:23Z (GMT). No. of bitstreams: 1 Mauro Melo_Dissert.pdf: 1426265 bytes, checksum: 0a54c25d1117b83eb91a5131e2fc6841 (MD5) Previous issue date: 2007-10-17 / In the past 20 years, some cities of the Metropolitan Area of Recife - PE, have been affected by several problems in Civil Engineering constructions, some of which resulted in human deaths. The most serious of these problems, given the number of constructions involved, concerns the specific building called box ; some of the buildings did fall and several others have been interdicted. Just a few of them were cleared and the majority of them continue to be interdicted. The general objective of the present dissertation is to analyze the awards produced on the building type box , built in the cities of Olinda, Jaboatão dos Guararapes and Paulista. Its goal is to study the causes pointed out as responsible for the collapse and interdictions of those constructions. In a general way, it can be pointed out as causes of the collapses, the following ones: imperfections or insufficiency of project (31.4%); low quality or inadequacies of the materials (17.1%); construction mistakes (34.4%); environmental causes (17.1%). For the interdictions: imperfections or insufficiencies of project (21.4%); low quality or inadequacies of the materials (3.5%); construction mistakes (2.8%); inadequate use or lack of maintenance (26.0%); environmental causes (4.3%); other causes (42.0%). The buildings were cleared when the conditions made by the Civil Defense of each city were met; they involved structural problems and habitability. It s also evident an inadequate performance of the inspection agencies and the lack of standardization of the awards, as well as the absence of a model for the adequate recovery of these constructions. One expects to have contributed, through the analysis and systematization of the data contained in the studied awards, for future works, aiming at the development of technology capable to equate the situation of the cited real estates. / Nos últimos 20 anos, alguns municípios da Região Metropolitana do Recife - PE, têm sido afetados por problemas diversos em obras de Engenharia Civil, contabilizando, inclusive, óbitos. O mais grave desses problemas, dado ao número de edificações envolvidas, diz respeito aos prédios tipo caixão ; alguns ruíram e vários foram e estão interditados e houve desinterdição. O objetivo geral da presente dissertação é analisar os laudos técnicos produzidos sobre os prédios tipo caixão , construídos nos Municípios de Olinda, Jaboatão dos Guararapes e Paulista - PE, tendo como meta estudar as causas apontadas para os desabamentos e interdições das referidas edificações. De um modo geral, pode-se apontar como causas dos desabamentos, as seguintes: falhas ou insuficiência de projeto (31,4%); baixa qualidade ou inadequação dos materiais (17,1%); falhas ou vícios de construção (34,4%); causas ambientais (17,1%). Já para as interdições: falhas ou insuficiência de projeto (21,4%); baixa qualidade ou inadequação dos materiais (3,5%); falhas ou vícios de construção (2,8%); uso inadequado ou falta de manutenção (26,0%); causas ambientais (4,3%); outras causas (42,0%). As desinterdições ocorreram quando foram atendidas as restrições feitas pela Defesa Civil de cada município, e que envolviam problemas estruturais e de habitabilidade. Constata-se também uma atuação inadequada dos órgãos de fiscalização e a ausência de padronização dos laudos e de um modelo técnico para a recuperação adequada dessas construções. Espera-se ter contribuído, através da análise e sistematização dos dados contidos nos laudos estudados, para trabalhos futuros, visando o desenvolvimento de tecnologia capaz de equacionar a situação dos referidos imóveis
4

Avaliação do grau do dano das estruturas do subsolo de três edifícios situados na Região Metropolitana do Recife / Evaluation of the degree of damage in the subsoil structures of three buildings situated in the Region Metropolitan of Recife/PE

Lemos, Sérgio Pereira Pinto 20 April 2006 (has links)
Made available in DSpace on 2017-06-01T17:57:27Z (GMT). No. of bitstreams: 1 pre-textual.pdf: 28868 bytes, checksum: 1349eefd05bbc7c21b1dd3b9e4b92ecb (MD5) Previous issue date: 2006-04-20 / This work aims to evaluate the pathology of residential buildings structures located at the Metropolitan Region of Recife, Brazil using the quantification of damages to measure the degree of early deterioration of reinforced concrete. Three residential buildings (RB) with similar construction standards were studied. All buildings have approximate age and are inserted into environmental aggressiveness distinct. A visual inspection took place as well as a laboratorial sample analysis of their pillars, beams and underground water reservatories. It was verified that the RB1 case, located at a high environmental aggressiveness class (III), and the RB2 case, located significatively far from the sea and classified with a moderate environmental aggressiveness class (II), both presented a medium degree of deterioration (GDE). For both buildings it is suggested a periodic inspection recommendation and a medium term intervention (GD 1 = 36,98 ; GD 2 = 31,23). The third case (RB3), located at a high environmental aggressiveness class (III) and seafront with protection barriers, presented a high degree of deterioration (GD 3=103,94). It is suggested for RB3 an immediate intervention with collapse risks / Procurando conhecer o grau de deterioração precoce das estruturas de concreto armado dos edifícios residenciais da Região Metropolitana da Cidade do Recife, Estado de Pernambuco, este trabalho visa, utilizando um método de quantificação dos danos e o uso de ensaios, avaliar as patologias das estruturas estudadas. Estudou-se três edifícios residenciais (ER), com semelhante padrão de construção, idades construtivas aproximadas e inseridos em diferentes classes de agressividade ambiental. Foi realizada inspeção visual e ensaios em amostras dos pilares, vigas, lajes e reservatório inferior do subsolo dos três edifícios. Após análise dos três edifícios, verificou-se que o caso ER 1, localizado em classe ambiental de agressividade forte (III), a mais agredida pelo meio ambiente, e o estudo de caso ER 2, localizado a uma distância significativa da orla marinha em Classe de Agressividade Ambiental II, apresentaram grau de deterioração media (GD) de 36,98 e 31,23 respectivamente, com recomendação para inspeção periódica e intervenção a médio prazo. Já o estudo de caso ER 3, que está localizado dentro da uma classe de agressividade forte (III), em orla marinha, porém com barreiras de proteção que evitam a incidência direta da névoa salina, encontra-se com alto grau de deterioração (GD = 103,94), sugerindo uma intervenção imediata com riscos de colapso