• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 17
  • 17
  • 17
  • 17
  • 10
  • 7
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Monitoring the Recovery from a Temporary Threshold Shift Using an Adaptive Procedure and Measurements of Spontaneous and Distortion Product Otoacoustic Emissions

Smurzynski, Jacek 01 January 2014 (has links)
No description available.
12

On noise and hearing loss : Prevalence and reference data

Johansson, Magnus January 2003 (has links)
Noise exposure is one of the most prevalent causes of irreversible occupational disease in Sweden and in many other countries. In hearing conservation programs, aimed at preventing noise-induced hearing loss, audiometry is an important instrument to highlight the risks and to assess the effectiveness of the program. A hazardous working environment and persons affected by it can be identified by monitoring the hearing thresholds of individual employees or groups of employees over time. However, in order to evaluate the prevalence of occupational noise-induced hearing loss, relevant reference data of unexposed subjects is needed. The first part of this dissertation concerns the changes in hearing thresholds over three decades in two occupational environments with high noise levels in the province of Östergötland, Sweden: the mechanical and the wood processing industries. The results show a positive trend, with improving median hearing thresholds from the 1970s into the 1990s. However, the hearing loss present also in the best period, during the 1990s, was probably greater than if the occupational noise exposure had not occurred. This study made clear the need for a valid reference data base, representing the statistical distribution of hearing threshold levels in a population not exposed to occupational noise but otherwise comparable to the group under study. In the second part of the dissertation, reference data for hearing threshold levels in women and men aged from 20 to 79 years are presented, based on measurements of 603 randomly selected individuals in Östergötland. A mathematical model is introduced, based on the hyperbolic tangent function, describing the hearing threshold levels as functions of age. The results show an age-related gender difference, with poorer hearing for men in age groups above 50 years. The prevalence of different degree of hearing loss and tinnitus is described for the same population in the third part of the dissertation. The overall prevalence of mild, moderate, severe or profound hearing loss was 20.9% collectively for women and 25.0% collectively for men. Tinnitus was reported by 8.9% of the women and 17.6% of the men. Approximately 2.4% of the subjects under study had been provided with hearing aids. However, about 7.7% were estimated to potentially benefit from hearing aids as estimated from their degree of hearing loss. Noise-induced hearing loss primarily causes damage to the outer hair cells of the inner ear. The fourth and last part of the dissertation evaluates the outer hair cell function, using otoacoustic emission measurements (OAE). Prevalence results from three different measuring techniques are presented: spontaneous otoacoustic emissions (SOAE), transient evoked otoacoustic emissions (TEOAE) and distortion product otoacoustic emissions (DPOAE). Gender and age effects on the recorded emission levels were also investigated. Women showed higher emission levels compared to men and for both women and men the emission levels decreased with increasing age. The results from the OAE recordings were shown to be somewhat affected by the state of the middle ear. The study included tympanometry, and the relation of the outcome ofthis test to the otoacoustic emissions is described, where high middle ear compliance resulted in low emission level. Reference data for the tympanometric measurements are also presented. The results of this project form an essential part of the important work against noiseinduced hearing loss, which needs continuous monitoring. The reference data presented here will provide a valid and reliable data base for the future assessment of hearing tests performed by occupational health centres in Sweden. This data base will in turn prove useful for comparison studies for Sweden as a responsible fellow EU member country setting high standards for work force safety. The statistical distribution of hearing threshold levels as a function of age for men and women in tabulated form is available on the Swedish Work Environment Authority (Arbetsmiljöverket) web site: http://www.av.se/publikationer/bocker/fysiskt/h293.shtm.
13

The feasibility of including Distortion Product Otoacoustic Emissions (DPOAEs) in the annual medical surveillance test battery for the identification of noise-induced hearing loss in a group of workers in a beverage manufacturing industry.

Reddy, Tarryn Marisca. 29 November 2013 (has links)
The study investigated the feasibility of including DPOAEs in the annual medical surveillance test battery for the identification of NIHL in a group of employees in a manufacturing industry in KwaZulu-Natal. Feasibility was investigated by exploring the sensitivity, specificity and predictive efficiency of DPOAEs, the ability of DPOAEs to detect subtle noise-induced cochlea changes, the test-retest reliability of DPOAEs and lastly, the duration of time taken to conduct the DPOAE test bilaterally. A cross-sectional and repeated measures within-in participant design was utilized in the study. A purposive convenience sampling technique was used, as well as a stratified sampling approach in order to realize objective two of the study. The study consisted of 60 participants, which were further stratified into four test groups, i.e. Group A: 0-3 years, Group B: 3.1-6 years and Group C: 6.1-9 years and Group D: 9.1-13 years of working within the beverage manufacturing industry. A high sensitivity and negative predictive value was reported in the current study, suggesting that DPOAEs may be able to identify those who present with subtle cochlea changes as a result of exposure to occupational noise. The sensitivity of DPOAEs was 100% at 1, 2, 4, 6 and 8kHz in the right ear and at 4 and 6kHz in the left ear. The specificity of DPOAEs in the current study ranged between 55%-97% across the frequency range in the right ear and 49%-88% in the left ear. A negative predictive value of 100% was obtained bilaterally across the frequency range, except at 8kHz in the left ear. Visual inspection of the DPgram in the current study revealed a bilateral reduction in DPOAE amplitudes for all test groups in the high frequency region of the DP-Gram, namely, 5477Hz and 7303Hz, in the absence of a statistically significant difference (p>0.05). A greater frequency range appears to be affected in this group of workers, indicating that the type of noise, namely, impulse noise, may result in cochlea changes. Corresponding changes on the pure tone audiogram were not observed, however, noise notch configurations were observed for the groups with a longer history of noise exposure. This was not seen bilaterally as is typically expected with NIHL. Good test-retest reliability across the frequency range obtained in the current study further indicates the feasibility of including DPOAEs in the annual medical surveillance test battery. Additionally, the current study calculated an average of 86 seconds (1 minute 26 seconds) to conduct the DPOAE test bilaterally, confirming that DPOAEs are a quick test to administer. The findings of this study suggest that DPOAEs may be used to monitor early subtle noise-induced cochlea changes for workers exposed to noise in the beverage manufacturing industry as part of the annual medical surveillance test battery. / Thesis (M.Comm.Path.)-University of KwaZulu-Natal, Westville, 2013.
14

Spectral-based tests for periodicities

Wei, Lai 18 March 2008 (has links)
No description available.
15

Modulation von Distorsionsprodukt-Otoemissionen duch Töne tiefer Frequenz

Hirschfelder, Anke 24 July 2001 (has links)
Die Modulation von Distorsionsprodukt-Otoemissionen (DPOAE) durch Töne tiefer Frequenz ist ein Methode, mit der die Auswirkung von Verlagerungen der kochleären Trennwand auf die Funktion des kochleären Verstärkers untersucht werden kann. Damit bietet sie einen neuen objektiven Ansatz zur Diagnostik unterschiedlicher kochleärer Hörstörungen sowie zur Untersuchung physiologischer Mechanismen der Kochlea. Durch einen tieffrequenten Ton (f = 32,8 Hz) werden die DPOAE in Abhängigkeit von dessen Phase periodisch verändert. Die Ausprägung der Modulation hängt von den Parametern des Tieftons und der Primärtöne (mit den Frequenzen f1 und f2) ab. Bei zwölf normalhörenden Probanden wird der Einfluß des Tieftonpegels, der Primärtonpegel und der Primärtonfrequenzen auf die Modulation der DPOAE mit der Frequenz 2f1-f2 untersucht. Die Ergebnisse dieser Methode werden mit denen der subjektiven Phasenaudiometrie bei diesen Probanden verglichen. Mit den Primärtonfrequenzen f1 = 2,5 und f2 = 3 kHz steigt die mittlere Modulationstiefe der DPOAE mit zunehmendem Tieftonpegel sowie mit abnehmenden Primärtonpegeln nichtlinear. Mit hohem Tieftonpegel (L = 115 dB SPL) und geringen Primärtonpegeln (bis zu L1 = 50 und L2 = 30 dB HL) sind DPOAE-Pegelverläufe mit zwei Minima und zwei Maxima pro Tieftonperiode zu beobachten. Die Pegelminima liegen kurz nach der maximalen Druck- bzw. Sogphase des Tieftons vor dem Trommelfell, entsprechend der maximalen Auslenkung der kochleären Trennwand in Richtung Scala vestibuli bzw. Scala tympani. Sie zeigen eine mittlere Latenz von 4 ms gegenüber den Verdeckungsmaxima der subjektiven Mithörschwelle im Phasenaudiogramm, die wahrscheinlich durch die Summe der Antwortzeit der aktiven kochleären Prozesse und der Laufzeit der DPOAE-Signale retrograd aus der Kochlea zur Meßsonde im äußeren Gehörgang zustande kommt. Mit geringeren Tieftonpegeln (L = 110 dB SPL) bzw. höheren Primärtonpegeln (ab L1 = 55 und L2 = 40 dB HL) sowie höheren Primärtonfrequenzen (f1 = 4, f2 = 4,8 kHz) sind nur noch jeweils ein DPOAE-Pegelminimum und -maximum pro Tieftonperiode zu beobachten. Mit den Primärtonfrequenzen f1 = 5 und f2 = 6 kHz zeigt sich keine Modulation der DPOAE mehr. Die Ergebnisse werden unter Verwendung einer Boltzmannfunktion zweiter Ordnung als Annäherung an die mechano-elektrische Transferfunktion äußerer Haarzellen simuliert. Bei einigen Probanden werden außerdem die Modulation der DPOAE mit der Frequenz 3f1-2f2 durch den tieffrequenten Ton sowie der Einfluß spontaner otoakustischer Emissionen (SOAE) auf die Messung tieftonmodulierter DPOAE untersucht. / Low-frequency modulation of distortion product otoacoustic emissions (DPOAE) is a method which allows to investigate the effect of the displacement of the cochlear partition on the function of the active cochlear process. It offers a new objective approach to diagnose different sensory hearing disorders as well as to investigate physiological cochlear mechanisms. The DPOAE are modulated by a low-frequency tone (with the frequency f = 32,8 Hz), depending on its phase. The extent of this modulation depends on the acoustic parameters of the suppressing low-frequency tone and the stimulating primary tones (f1 and f2). In twelve normal hearing subjects the influence of the low-frequency tone level, the levels and the frequencies of the primary tones on the modulation of the DPOAE with the frequency 2f1-f2 are investigated. In these subjects, the phase-dependent masked subjective threshold is also registered. The results of both methods are compared. With the primary tone frequencies f1 = 2,5 and f2 = 3 kHz the mean value of the DPOAE modulation depth presents a nonlinear growth with increasing low-frequency tone level and decreasing primary tone levels, respectively. With high low-frequency tone level (L = 115 dB SPL) and low primary tone levels (up to L1 = 55 and L2 = 40 dB HL), the time course of the DPOAE level shows two minima and two maxima within one period of the low-frequency tone. The minimal DPOAE levels are registered shortly after the phases of maximal condensation and rarefaction of the low-frequency tone in front of the eardrum, respectively, corresponding to the largest displacement of the cochlear partition towards the scala tympani and the scala vestibuli. The time course of the DPOAE level shows a mean latency of 4 ms with regard to the masking patterns of the phase-dependent masked threshold, due to the response time of the active cochlear process and the retrograde travelling time of the DPOAE. With lower low-frequency tone levels (L1 = 110 dB SPL), higher primary tone levels (from L1 = 55, L2 = 40 dB HL), and higher primary tone frequencies (f1 = 4, f2 = 4,8 kHz), respectively, the DPOAE level presents only one maximum and one minimum per period of the low-frequency tone. With the primary frequencies f1 = 5 and f2 = 6 kHz no modulation of the DPOAE is registered. The results are simulated using a second-order Boltzmann function as an approximation of the mechano-electric transfer function of the outer hair cells. Additionally, in some subjects the low-frequency modulation of the DPOAE with the frequency 3f1-2f2 and the influence of spontaneous otoacoustic emissions (SOAE) on the registration of low-frequency modulated DPOAE are investigated.
16

Hearing screening for infants from a neonatal intensive care unit at a state hospital

Stearn, Natalie Anne 21 July 2008 (has links)
Infant hearing screening (IHS) programs are not yet widespread in developing countries, such as South Africa. In order to ensure that the benefits of early hearing detection and intervention (EHDI) programs reach all infants, initial recommendations for the implementation of IHS programs in South Africa have been made by the Year 2002 Hearing Screening Position Statement by the Health Professions Council of South Africa. One of the platforms recommended for IHS in South Africa is the neonatal intensive care unit (NICU). South African NICU infants are at an increased risk for hearing loss, resultant of their high-risk birth histories, as well as the prevalence of context-specific environmental risk factors for hearing loss. There is currently a general scarcity of contextual data regarding the prevalence of risk indicators for hearing loss, and the prevalence of auditory impairment in the South African NICU population. The objective of this study was to describe an IHS program for NICU infants at a secondary hospital in Gauteng, South Africa. A quantitative descriptive research design was used to report on a cohort of 129 NICU infants followed up during a 29 month period. The objective of the study was achieved by describing the sample of infants in terms of the presence of specific risk indicators for hearing loss, the efficiency of the IHS program, and the incidence of auditory pathologies. Infants received their initial hearing screening as part of their medical and developmental follow-up visit at the hospital at three months of age. Routine rescreening visits were scheduled three monthly, whilst infants who failed the hearing screening were requested to return after three weeks for a follow-up. A data collection sheet was used to collect biographical information and risk indicators for hearing loss. Immittance measurements were recorded in the form of high-frequency and low-frequency tympanometry. Distortion product otoacoustic emissions (DPOAE) and automated auditory brainstem responses (AABR) were recorded, as well as diagnostic auditory brainstem responses (ABR) in cases where infants referred the screening protocol. Results revealed that environmental risk factors present in this sample included poor maternal education levels and prenatal HIV/AIDS exposure. At least 32% of mothers participating in this study did not complete high school. Prenatal HIV/AIDS exposure was present in at least 21% of the current sample of infants. The screening coverage rate fell short of the 95% benchmark set by the Joint Committee on Infant Hearing (JCIH, 2000). A 67% coverage rate was achieved with AABR screening, and an 88% coverage rate was achieved with DPOAE screening. 93% of infants had immittance screening performed on their initial visit to the IHS program. According to the Fisher’s two-sided exact test and the logistic regression procedure, high frequency tympanometry proved to be more effective than low frequency tympanometry, when assessing the middle ear functioning of infants younger than seven months when compared with DPOAE results. Normative pressure and admittance data was compiled for the use of high frequency tympanometry in NICU infants. Poor follow-up rates were recorded for both routine and non-routine visits, but are expected to improve over time. Furthermore, results indicated a high incidence of hearing impairment. Permanent congenital hearing loss was identified in 3% (n=4) of the sample. Half of these presented with sensorineural hearing loss, whilst the other half had auditory neuropathy. The incidence of auditory impairment is estimated to be 3.75% if the percentage of infants who did not return for follow-up is taken into account. A high incidence of middle ear pathology was recorded, with an incidence rate of 60.4%, including bilateral and unilateral middle ear pathology. The high prevalence of auditory impairment in South African NICU infants, and the lack of widespread IHS programs, indicates that many vulnerable infants are being the denied the benefits of early identification of and intervention for hearing loss. The implementation of widespread IHS programs in South Africa is therefore essential, in order to ensure that all South African infants receive the benefits of EHDI programs. / Dissertation (MCommunication Pathology)--University of Pretoria, 2007. / Speech-Language Pathology and Audiology / unrestricted
17

Hydropsdiagnostik mit Tieftonmodulation von Distorsionsprodukt-Otoemissionen

Goßow-Müller-Hohenstein, Elmen 09 November 2005 (has links)
Ein tieffrequenter lauter Suppressorton verlagert das Corti-Organ periodisch in Richtung Scala vestibuli und Scala tympani. Simultan registrierte DPOAE (Distorsionsprodukte otoakustischer Emissionen) werden in beiden Richtungen unterschiedlich supprimiert. Bei Vorliegen eines endolymphatischen Hydrops (EH) ist die Beweglichkeit der Basilarmembran eingeschränkt, so daß keine oder eine nur geringe Modulation des DPOAE-Pegels entstehen kann. In dieser Arbeit wird die diagnostische Aussagekraft von Messungen tieftonmodulierter DPOAE bei zwei Patientenkollektiven mit Verdacht auf EH im Vergleich mit einem Normalkollektiv (n = 22) geprüft: bei Patienten mit M. Menière (n = 23) und Patienten mit Ohrdruckgefühl ohne Schwindelsymptomatik (n = 8). Bei den M. Menière-Patienten sind die ipsilateralen Modulationstiefen (MD) im Median hochsignifikant geringer als die des Normalkollektivs. Dies wird als Hinweis auf einen EH gewertet. Bei Primärtonpegeln mit L2 = 20 dB SL ergibt sich für den Grenzwert der MD mit 6 dB die Sensitivität von 64% und die Spezifität von 90%. Die kontralateralen MD der M. Menière-Patienten sind im Median signifikant geringer als die des Normalkollektivs. Für Primärtonpegel mit L2 = 20 dB SL liegen 33% der Werte unter dem Grenzwert, von diesen Ohren ist die Hälfte symptomfrei. Auch im kontralateralen Ohr kann ein – eventuell asymptomatischer – Hydrops vorliegen. Die Ergebnisse der Patienten mit Ohrdruckgefühl ohne Schwindel zeigen im Median hochsignifikant geringere MD als die der Normalhörenden und unterscheiden sich nicht signifikant von den Werten der ipsilateralen Ohren der M. Menière-Patienten. Das Ohrdruckgefühl kann auf einen cochleären Hydrops hinweisen und die weitere Entwicklung eines EH ankündigen. Bei den Verlaufsuntersuchungen zeigen die MD beider Patientenkollektive, deren Symptomatik sich während dieses Zeitraums änderte, Variabilitäten: mit Zunahme der Heftigkeit der spezifischen Symptome nimmt die MD ab und umgekehrt. Die Tieftonmodulation scheint den Zustand der Cochlea widerspiegeln zu können. Im Vergleich mit den in der Klinik gängigen Verfahren zur Hydropsdiagnostik wie der ECochG oder dem Glyceroltest erweist sich das in dieser Arbeit angewandte objektive Verfahren als vorteilhaft: es ist schnell durchführbar, nicht belastend und nicht invasiv. Es eignet sich als Screeningverfahren und kann zur Verlaufskontrolle eingesetzt werden. / The cochlear partition is moved periodically towards scala vestibuli and scala tympani by a low-frequency high-level suppressor tone. Simultaneously recorded DPOAEs (distortion product otoacoustic emissions) are suppressed differently in both directions. This modulation of the DPOAE level may be reduced or even missing if the displacement of the basilar membrane is inhibited by endolymphatic hydrops (EH). In this thesis the diagnostic significance of the low-frequency modulation of DPOAEs is tested in two patient groups with suspected EH: patients with Menière’s disease (n = 23) and patients with aural fullness without vertigo (n = 8), compared to a control group of normal hearing adults (n = 22). In the patients with Menière’s disease the ipsilateral modulation depths (median) are high significantly lower than in the control group. This can be interpreted as a sign of EH. At primary tone levels with L2 = 20 dB SL and a limiting value of 6 dB modulation depth (MD), a sensitivity of 64% and a specificity of 90% are found. The contralateral MDs of the patients with Menière’s disease (median) are significantly lower than in the control group. At primary tone levels with L2 = 20 dB SL, 33% of the MDs are below the limiting value, half of these ears are symptom-free. So in the contralateral ear a possibly asymptomatic hydrops may be present as well. The patients with aural fullness without vertigo show high significantly lower MDs (median) than the normal hearing adults and no significant difference to the ipsilateral MDs of the patients with Menière’s disease. Aural fullness can be a sign of cochlear hydrops and may indicate the further development of EH. During the course of disease the MDs of both patient groups vary when symptoms change: with increasing intensity of the specific symptoms the MD is reduced and vice versa. Low-frequency modulation seems to reflect the state of the cochlea. Compared to the generally used clinical tests for the assessment of EH like ECochG or the glycerol test, the objective method presented in this thesis is advantageous: it is fast, not straining and non-invasive. It is suitable for screening and can be used to monitor the course of disease.

Page generated in 0.1935 seconds