• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 51
  • 2
  • Tagged with
  • 53
  • 53
  • 53
  • 51
  • 51
  • 51
  • 51
  • 51
  • 51
  • 51
  • 51
  • 51
  • 51
  • 51
  • 51
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Totara Valley micro-hydro development : a thesis presented in partial fulfillment of the requirements for the degree of Master of Applied Science in Renewable Energy Engineering, Massey University, Palmerston North, New Zealand

Donnelly, David Ronald Unknown Date (has links)
This study focuses on the design, construction and operation of a distributed generation system based on micro-hydro technology. The project is sited in the Totara Valley, a small rural community approximately 70km from the Massey University, Turitea campus, Palmerston North. The Massey University Centre for Energy Research (MUCER) has a long history of renewable energy research within the Totara Valley community. This project complements these existing schemes and provides a foundation for future research into distributed generation technologies. The project encompasses the following objectives: - to gain practical experience in the design, engineering and implementation of a distributed generation system in rural New Zealand; - to evaluate contemporary micro-hydro technology and compare the performance of this equipment in a theoretical and practical context; - to identify barriers that hinder the widespread adoption of micro-hydro systems in rural New Zealand; - to develop a spreadsheet based life cycle costing tool. The results from this study demonstrate that economic considerations are the fundamental aspect to be considered when assessing the long-term viability of these projects. The viability of micro-hydro projects are primarily determined by four factors: - the volume and head (height) of water available above the turbine site; - the length and therefore the cost of the pipeline required for transporting water to the turbine; - the legal and administrative costs involved in obtaining a resource consent to maintain access to the water resources; - the prices received and paid for electricity. Considerable charges were payable to the local authority to secure and maintain the right to harness the water resources at this site. This cost contributed considerable risk to the project and creates a significant barrier to establishing similar systems at other sites. The reduction of resource consent charges to levels that fairly reflect the negligible environmental impacts of these projects would encourage the adoption of this technology and deliver benefits to rural New Zealand communities.
52

Sistema fotovoltaico trifásico de único estágio conectado a sistemas de geração distribuída operando como condicionador de qualidade de energia unificado usando uma estratégia dual de compensação ativa de potência / Single-stage three-phase grid-tied photovoltaic system operating as an universal power quality conditioner with dual compensation strategy

Campanhol, Leonardo Bruno Garcia 10 August 2017 (has links)
Este trabalho propõe um sistema fotovoltaico (PV) multifuncional conectado a um sistema elétrico trifásico a quatro fios e operando com estratégia dual de compensação ativa de potência. Além da injeção de potência ativa na rede elétrica, o sistema PV operara como um condicionador unificado de qualidade de energia (UPQC) suprimindo as correntes harmônicas da carga e compensando a potência reativa. Adicionalmente, tensões balanceadas, reguladas e livre de harmônicos são fornecidas para a carga. O sistema PV-UPQC é baseado em uma estratégia de compensação dual, na qual o conversor série opera como uma fonte de corrente senoidal, enquanto o conversor paralelo atua como uma fonte de tensão senoidal. Como resultado, nenhum comportamento transitório é observado na troca entre os modos de operação ilhado e interconectado do sistema PV-UPQC. Além disso, para contornar os problemas associados às mudanças bruscas de irradiação solar, uma malha de controle feed-forward atua na geração das referências de corrente do conversor série, de modo que se obtenha um rápido balanço de potência entre o sistema PV e a rede elétrica. Como resultado, as respostas dinâmicas tanto da corrente elétrica quanto da tensão do barramento CC são melhoradas. A análise detalhada envolvendo o fluxo de potência ativa dos inversores é realizada proporcionando um melhor entendimento sobre a operação do sistema PV-UPQC, bem como auxiliando no dimensionamento dos conversores de potência. Resultados de simulação e experimentais são apresentados para avaliar os desempenhos estáticos e dinâmicos do PV-UPQC conectado ao sistema elétrico de distribuição. / This work proposes a multifunctional single-stage three-phase four-wire grid-connected photovoltaic (PV) system operating with a dual active power-line compensating strategy. Besides injection of active power into the grid, the PV system operates as a unified power quality conditioner (UPQC), suppressing the load harmonic currents and compensating reactive power. Additionally, regulated, balanced and harmonic free output voltages are provided to the load. Since the PV-UPQC is based on a dual compensation strategy, the series converter operates as a sinusoidal current source, whereas the parallel converter operates as a sinusoidal voltage source. Thus, seamless transition can be achieved from the interconnected to the islanding operation modes, and vice-versa, without load voltage transients. Moreover, to overcome problems associated with sudden solar irradiation changes, fast power balance involving the PV array and the grid is obtained, since the feed-forward control loop acts on the generation of the series inverter current references. As a result, the dynamic responses of both inverter currents and dc-bus voltage are improved. Detailed analysis involving the active power flow through the inverters is performed allowing proper understanding of the PV-UPQC operation, as well as assisting to design of the power converters. Simulation and experimental results are presented to evaluate both dynamic and static performances of the PV-UPQC tied to the electrical distribution system.
53

Sistema fotovoltaico trifásico de único estágio conectado a sistemas de geração distribuída operando como condicionador de qualidade de energia unificado usando uma estratégia dual de compensação ativa de potência / Single-stage three-phase grid-tied photovoltaic system operating as an universal power quality conditioner with dual compensation strategy

Leonardo Bruno Garcia Campanhol 10 August 2017 (has links)
Este trabalho propõe um sistema fotovoltaico (PV) multifuncional conectado a um sistema elétrico trifásico a quatro fios e operando com estratégia dual de compensação ativa de potência. Além da injeção de potência ativa na rede elétrica, o sistema PV operara como um condicionador unificado de qualidade de energia (UPQC) suprimindo as correntes harmônicas da carga e compensando a potência reativa. Adicionalmente, tensões balanceadas, reguladas e livre de harmônicos são fornecidas para a carga. O sistema PV-UPQC é baseado em uma estratégia de compensação dual, na qual o conversor série opera como uma fonte de corrente senoidal, enquanto o conversor paralelo atua como uma fonte de tensão senoidal. Como resultado, nenhum comportamento transitório é observado na troca entre os modos de operação ilhado e interconectado do sistema PV-UPQC. Além disso, para contornar os problemas associados às mudanças bruscas de irradiação solar, uma malha de controle feed-forward atua na geração das referências de corrente do conversor série, de modo que se obtenha um rápido balanço de potência entre o sistema PV e a rede elétrica. Como resultado, as respostas dinâmicas tanto da corrente elétrica quanto da tensão do barramento CC são melhoradas. A análise detalhada envolvendo o fluxo de potência ativa dos inversores é realizada proporcionando um melhor entendimento sobre a operação do sistema PV-UPQC, bem como auxiliando no dimensionamento dos conversores de potência. Resultados de simulação e experimentais são apresentados para avaliar os desempenhos estáticos e dinâmicos do PV-UPQC conectado ao sistema elétrico de distribuição. / This work proposes a multifunctional single-stage three-phase four-wire grid-connected photovoltaic (PV) system operating with a dual active power-line compensating strategy. Besides injection of active power into the grid, the PV system operates as a unified power quality conditioner (UPQC), suppressing the load harmonic currents and compensating reactive power. Additionally, regulated, balanced and harmonic free output voltages are provided to the load. Since the PV-UPQC is based on a dual compensation strategy, the series converter operates as a sinusoidal current source, whereas the parallel converter operates as a sinusoidal voltage source. Thus, seamless transition can be achieved from the interconnected to the islanding operation modes, and vice-versa, without load voltage transients. Moreover, to overcome problems associated with sudden solar irradiation changes, fast power balance involving the PV array and the grid is obtained, since the feed-forward control loop acts on the generation of the series inverter current references. As a result, the dynamic responses of both inverter currents and dc-bus voltage are improved. Detailed analysis involving the active power flow through the inverters is performed allowing proper understanding of the PV-UPQC operation, as well as assisting to design of the power converters. Simulation and experimental results are presented to evaluate both dynamic and static performances of the PV-UPQC tied to the electrical distribution system.

Page generated in 0.1466 seconds