Spelling suggestions: "subject:"drystack masonry"" "subject:"haystack masonry""
1 |
Strength evaluation of dry-stack masonryPave, Rogério Francisco 25 September 2008 (has links)
Accelerated dry-stack masonry construction is seen all over the world in the last two decades.
Intense investigation on structural behaviour of dry-stack masonry is also seen worldwide.
This research work, presents an investigation of the structural behaviour of Hydraform drystack
masonry developed in South Africa. Unit compressive strength, masonry wall
compressive strength and flexural resistance of dry-stack masonry/reinforced concrete beams
were investigated.
Due to the interlocking mechanism nature of Hydraform dry-stack blocks, three different unit
compressive testing methods were investigated. The methods are described as:
- Shoulder test;
- Centre test;
- Cube test.
Tests were carried out under different humidity conditions:
- Dry;
- Wet;
- Normal.
Influence of different cement contents within the block units and moisture contents were
investigated. The study made proposal of Hydraform block unit grads to be used for design.
Compressive strength of dry-stack masonry walls was experimentally investigated. Dry-stack
masonry wall specimens made by different block grades were subjected to in-plane vertical
uniformly distributed load. Test results were used to establish dry-stack masonry
characteristic compressive strength for several block grades.
Flexural strength of dry-stack masonry/reinforced concrete composite beams was
investigated. Series of beams were tested for flexural resistance. Applicability of conventional
reinforced masonry flexural analysis philosophy was established.
|
2 |
Stability of Dry-Stack MasonryNgowi, Joseph Vincent 01 November 2006 (has links)
Student Number : 0100677A -
PhD thesis -
School of Civil and Environmental Engineering -
Faculty of Engineering and the Built Environment / This thesis presents the findings on empirical study of dry-stack masonry.
Dry-stack masonry refers to a method of building masonry walls, where most of
the masonry units are laid without mortar in the joints. Of late (since mid eighties)
in modern construction, dry-stacking or mortarless technology is increasingly
becoming popular because of its advantages. The construction industry is
acknowledging the need to accelerate the masonry construction process, as the
traditional method is labour intensive and hence slower due to the presence of a
large number of mortar joints. Early attempts were made to increase the size of
masonry units (block instead of brick), thereby reducing the number of mortar
joints, wherein the use of bedding mortar imposed constraints on the number of
courses to be constructed in a day. Elimination of bedding mortar accelerates
construction; thereby reducing cost, variation due to workmanship and generally
small pool of skilled labour is required in dry stacking. Dry-stack masonry is a
relatively new technology not yet regulated in the code of practice and therefore
very limited information on the structural behaviour of the masonry is available.
This project is based on the investigation of the HYDRAFORM dry-stack system,
which utilises compressed soil-cement interlocking, blocks. The system is now
widely used in Africa, Asia and South America. The main objective of the project
was to establish through physical testing the capacity of the system to resist lateral
load (e.g. wind load), vertical load and dynamic load such as earthquake loading.
In the first phase of the project investigations were conducted under static loading
where series of full-scale wall panels were constructed in the laboratory and tested
under lateral loading, and others were tested under vertical loading to establish the
mode of failure and load capacity of the system. Series of control tests were also
conducted by testing series of wallettes to establish failure mechanism of the units
and to establish the flexural strength of the system. Finally the test results were
used for modelling, where load prediction models for the system under vertical
loading and under lateral loading were developed. The theoretical load prediction
models were tested against the test results and show good agreement. After the load capacity was established the next step in the study was to further improve the
system for increased capacity particularly under dynamic loading. The normal
Hydraform system was modified by introducing a conduit, which allows
introduction of reinforcements. Series of dry-stack seismic systems were
constructed and initially tested under static lateral loading to establish the lateral
load capacity.
The second Phase of the project was to investigate the structural behaviour and
performance of the Hydraform system under seismic loading. A shaking table of
20 tonnes payload, (4m x 4m) in plan was designed and fabricated. A full-scale
plain dry-stack masonry house was constructed on the shaking table and subjected
to seismic base motions. The shaking table test was performed using sine wave
signals excitations starting from low to very severe intensity. A conventional
masonry test structure of similar parameters was also constructed on the table and
tested in a similar manner for comparison. The tests were conducted using a
frequency range of 1Hz to 12Hz and the specimens were monitored for peak
accelerations and displacements. For both specimens the initial base motion was
0.05g.
The study established the mode of failure of the system; the structural weak points
of unreinforced dry-stack masonry, the general structural response of the system
under seismic condition and the failure load. The plain dry-stack masonry failed at
0.3g and the conventional masonry failed at 0.6g. Finally recommendations for
further strengthening of system to improve its lateral capacity were proposed.
|
3 |
In-Plane Cyclic Shear Performance of Interlocking Compressed Earth Block WallsBland, David William 01 June 2011 (has links)
This thesis presents results from testing of interlocking compressed earth block (CEB) masonry shear walls. CEBs are low strength earth masonry units sometimes stabilized with cement or lime. The interlocking compressed earth blocks (ICEBs) used in this experiment are dry stacked interlocking hollow units, which can be reinforced and grouted after they are laid. Although significant research has been undertaken to optimize the material properties of CEBs, little has been done to investigate the performance of structural systems currently being built using this technology.
Test results are reported for three 1800 mm x 1800 mm wall specimens constructed with cement stabilized ICEBs and subjected to cyclic in-plane lateral loading. Wall specifications were varied to identify the shear performance of partial and fully grouted walls, and to observe the performance of a flexure dominated wall panel. It was determined that the shear strength of fully grouted walls is significantly higher than that of partially grouted walls and calculation of capacity based on current ACI 530-08 masonry provisions significantly overestimates the shear strength of ICEB wall panels. Based on the observed performance, recommendations are made for limiting the calculated nominal shear strength in design. Results also indicate that calculations based on simple bending theory conservatively predict the flexural strength of a fully grouted ICEB wall. Discussion of ICEB material properties and recommendations for design and construction procedures are included.
|
4 |
In-Plane Shear Wall Performance As Affected by Compressed Earth Block ShapeAmbers, Steven Ellis 01 March 2017 (has links) (PDF)
This thesis investigates the in-plane shear performance of full-scale walls made from compressed earth blocks. Compressed earth blocks are a type of masonry where the blocks are composed of compressed soil and typically dry-stacked without mortar. Prior research has demonstrated that the in-plane shear strength of these blocks falls far short of capacities predicted by conventional masonry building codes, requiring new testing to develop effective and safe designs for seismic conditions. This thesis specifically studies the effects of block type and the use of grouted shear keys at the block head joints.
Three full-scale walls were constructed and tested under in-plane, cyclic loading. To compare the effect of block type on shear strength, one wall was constructed from Rhino blocks as used by the Center for Vocational Building Technology, while another used V-Lock blocks designed by the Vermeer Corporation. Apart from differences in size and interlock mechanism, the standard Rhino blocks have shear keys at the head joints which are not present on the V-Lock blocks. To examine the effect of these shear keys, a third wall was built from Rhino blocks with the shear keys removed.
The two standard block types displayed no major difference in strength that could not be attributed to grouted area or the presence/absence of the head joint shear keys. The Rhino block wall with shear keys reached a higher peak load relative to the grouted area but experienced a brittle drop in capacity after peaking, while the other two walls exhibited an extended loading plateau after the initial peak. All walls failed with cracking and block sliding along the main diagonals, a failure mode similar to conventional masonry. Proposals are made for modifying the equations for shear capacity from the Masonry Standards Joint Committee (MSJC) 2013 code for use in designing compressed earth block shear walls.
|
Page generated in 0.0417 seconds