• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 59
  • 2
  • Tagged with
  • 63
  • 48
  • 39
  • 32
  • 32
  • 30
  • 27
  • 18
  • 17
  • 17
  • 16
  • 16
  • 16
  • 15
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Estudo teórico-experimental da transferência de calor e da perda de pressão em um dissipador de calor baseado em microcanais / A theoretical and experimental study on heat transfer and pressure drop in a heat sink based on microchannels

Nascimento, Francisco Júlio do 28 May 2012 (has links)
A presente dissertação trata de um estudo teórico-experimental sobre escoamento monofásico e bifásico em um dissipador de calor baseado em microcanais. Este tipo de dissipador de calor tem sido usado para a intensificação da troca de calor em sistemas compactos e de alto desempenho. A intensificação da troca de calor promovida pelo escoamento em microcanais é acompanhada de um incremento na perda de pressão, portanto o estudo destes dois parâmetros é essencial para o entendimento dos fenômenos relacionados e fundamental para o desenvolvimento de ferramentas de projeto para dissipadores de calor baseados em microcanais. Inicialmente, um levantamento bibliográfico extenso sobre a ebulição convectiva em microcanais de reduzido diâmetro foi realizado. Este estudo da literatura trata de critérios de transição entre micro- e macro-escala, padrões de escoamento, métodos de previsão do coeficiente de transferência de calor e perda de pressão. Atenção específica foi dada a estudos de dissipadores de calor baseados em microcanais. Com base nesta análise da literatura, uma bancada experimental foi confeccionada para que dados experimentais de transferência de calor e perda de pressão pudessem ser levantados a partir de um dissipador de calor de microcanais. O dissipador de calor fabricado para este estudo é constituído de 50 microcanais retangulares dispostos paralelamente com 15 mm de comprimento, 100 µm de largura, 500 µm de profundidade e espaçados entre si de 200 µm. Experimentos foram executados para o R134a, velocidades mássicas de 400 a 1500 kg/m²s, título de vapor máximo de 0,35 e fluxos de calor de até 310 kW/m². Como conclusão deste trabalho observa-se perda de pressão elevada em relação aos valores fornecidos pelos métodos de previsão da literatura e um coeficiente de transferência de calor próximo ao estimado pelo modelo de três zonas proposto por Thome et al. (2004). / This study presents a theoretical and experimental investigation on single and two-phase flows in a microchannel based heat sink. Multi-microchannel heat sinks are able of dissipating extremely high heat fluxes under confined conditions. Such characteristics have attracted the attention of academia and industry and actually several studies are being carried out in order to evaluate and optimize such devices. Initially, an extensive investigation of the literature concerning convective boiling in micro-scale channels was performed. This literature review covers transitional criteria between micro- and macro-scale flow boiling, two phase flow patterns, heat transfer coefficient and pressure drop during convective boiling. Special attention was given to studies concerning microchannels based heat sinks. Based on this investigation, an experimental facility was built for performing heat transfer and pressure drop measurements during single-phase flow and flow boiling in microchannel based heat sinks. For this study, a microchannel based heat sink was also manufactured. The heat sink contains 50 rectangular parallel microchannels, 15 mm long, 100 µm wide by 500 µm deep and separated by 200 µm walls. Experiments were performed for R134a, mass velocity of 400-1500 kg/m²s, maximum vapor quality of 0,35 and heat fluxes up to 310 kW/m². The database obtained in the present study was compared against pressure drop and heat transfer coefficient prediction methods from the literature. It was found that no one method is accurate in predicting heat sink pressure drop while heat transfer coefficient results were accurately predicted by the 3-zone model proposed by Thome et al. (2004).
42

Estudo experimental da transferência de calor e queda de pressão na ebulição do isobutano em um mini-tubo

Oliveira, Jéferson Diehl de 22 February 2013 (has links)
Submitted by Maicon Juliano Schmidt (maicons) on 2015-03-30T19:21:01Z No. of bitstreams: 1 Jéferson Diehl de Oliveira.pdf: 1682128 bytes, checksum: 754d96de0ab9ab919137513dac6fe705 (MD5) / Made available in DSpace on 2015-03-30T19:21:01Z (GMT). No. of bitstreams: 1 Jéferson Diehl de Oliveira.pdf: 1682128 bytes, checksum: 754d96de0ab9ab919137513dac6fe705 (MD5) Previous issue date: 2013-01-31 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta um estudo experimental da transferência de calor e queda de pressão na ebulição convectiva do hidrocarboneto isobutano (R-600a) em um mini-tubo horizontal e circular de 2,6 mm de diâmetro interno. Também é analisada a influência do diâmetro sobre a queda de pressão em escoamento adiabático. No caso dos experimentos envolvendo a ebulição convectiva, os testes foram realizados com uma temperatura de saturação de 22 ºC, com uma pressão média de saturação de 323,5 kPa, com velocidade mássica variando entre 188 e 370 kg/(m²s) e fluxo de calor constante na seção de teste entre 28 e 134 kW/m². Os resultados obtidos experimentalmente foram comparados com resultados de correlações para a queda de pressão por atrito e o coeficiente de transferência de calor propostas por diferentes autores para ebulição em canais de pequeno diâmetro. Também foram observados os padrões de escoamento ao longo dos testes com o auxílio de uma câmera com alta velocidade de captura e relacionados com o fluxo de calor, título de vapor e o coeficiente de transferência de calor. / This work presents an experimental study of heat transfer and pressure drop in flow boiling of hydrocarbon isobutane (R-600a) in a horizontal and circular mini-tube with 2.6 mm of inner diameter. It is also analyzed the influence of diameter on the pressure drop in adiabatic flow. In the case of experiments involving flow boiling, the tests were performed at a saturation temperature of 22°C with a mean saturation pressure of 323.5 kPa, with mass velocity ranging between 188 and 370 kg/(m²s) and constant heat flux in the test section between 28 and 134 kW/m². The results obtained experimentally were compared with results of correlations for pressure drop due to friction and heat transfer coefficients proposed by different authors for boiling in channels of small diameter. It was also observed flow patterns along the tests with the aid of a camera with high speed capture and related with heat flux, vapor quality and heat transfer coefficient.
43

Efeito da rugosidade superficial na ebulição nucleada de refrigerantes halogenados em tubos horizontais / Effect of surface roughness on nucleate boiling heat transfer of halocarbon refrigerants on horizontal tubes

Stelute, Elvio Bugança 12 August 2004 (has links)
O estudo presente constitui uma análise da influência do acabamento superficial no coeficiente de transferência de calor na ebulição nucleada de refrigerantes halogenados. Dados para três superfícies distintas (cobre, latão e aço inoxidável), dois fluidos refrigerantes (R123 e R134a) e pressões reduzidas entre 0,023 e 0,26 são analisados com o intuito de verificar a influência da rugosidade nestes três parâmetros. O efeito da rugosidade foi avaliado com três acabamentos distintos (massa polidora, lixa e jato de areia) cobrindo uma faixa de rugosidades médias variando desde 0,03 até 10,5 micrômetro. Uma análise de diversas publicações da literatura foi levada a cabo, tendo sido particularmente investigadas algumas correlações que consideram o efeito do acabamento superficial em sua estimativa do coeficiente de transferência de calor. As tendências destas correlações são comparadas entre si e com os dados experimentais. A análise dos resultados permitiu levantar tendências inéditas na literatura consultada. A superfície em ebulição recebeu especial atenção com a obtenção de microfotografias e o cálculo de diversos parâmetros de rugosidade. Foram, ainda, investigados efeitos de envelhecimento da superfície, caracterizado pela diminuição do coeficiente de transferência de calor ao longo do tempo de ebulição. / The present research has been focused in an analysis of the effect of surface finishing on nucleate boiling heat transfer coefficient of halocarbon refrigerants. Experimental data for three different surface material (cooper, brass and stainless steel), two refrigerants (R123 and R134a) and reduced pressures between 0.023 and 0.26 have been analyzed aiming to verify the roughness effects on these three parameters. Three different finishing processes (polishing, emery papering and shot pining) have been used to result in an average roughness range from 0.03 to 10.5 micrometer. An analysis of varied publications and some correlations, particularly those which estimate the effect of surface roughness in heat transfer coefficient, has been done. The tendencies from these correlations have been compared with themselves and with experimental data. These results have shown some effects still unpublished. The boiling surface has received an especial attention, micro-photography has been taken and various parameters have been evaluated. Ageing effects, characterized by the reduction of heat transfer coefficient, have been verified and analyzed.
44

Determinação experimental de dados de equilibrio liquido-vapor de misturas binarias de componentes de oleos vegetais atraves da calorimetria diferencial exploratoria / Experimental determination of vapor-liquid equilibrium data of binary mixtures of fatty acids through Differential Scanning Calorimetry

Falleiro, Rafael Mauricio Matricarde 13 August 2018 (has links)
Orientadores: Maria Alvina Krahenbuhl, Antonio Jose de Almeida Meirelles / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-13T05:54:13Z (GMT). No. of bitstreams: 1 Falleiro_RafaelMauricioMatricarde_M.pdf: 2025398 bytes, checksum: 267d9b60efd1dc4f0a2818661c23761d (MD5) Previous issue date: 2009 / Resumo: Esse trabalho irá contribuir com alguns dados inéditos de equilíbrio líquido-vapor de compostos que constituem o biodiesel, pelo interesse imediato que este último tem despertado no mundo. Dados de Equilíbrio Líquido-Vapor (ELV) para três misturas binárias de ácidos graxos saturados foram medidos com sucesso através da Calorimetria Diferencial Exploratória (DSC). Esses dados são de grande interesse para as indústrias, principalmente as de biodiesel, já que processos como a cristalização ou a separação indesejada de componentes pode ser minimizada a partir do levantamento desses dados. Contudo, mudanças na célula de pressão do calorímetro e o uso de panelas herméticas com furo na tampa (f = 250 µm) foram necessárias para que a técnica analítica fosse possível de ser aplicada, apresentando precisão nos resultados, uso de pouca quantidade de amostra e menor tempo de operação. Foram determinados experimentalmente a 50 mmHg dados ELV dos seguintes sistemas: ácido mirístico (C14:0) + ácido palmítico (C16:0), ácido mirístico (C14:0) + ácido esteárico (C18:0), ácido palmítico (C16:0) + ácido esteárico (C18:0). Na pressão de 8 mmHg investigou-se o sistema ácido linoléico (C18:2) + ácido oléico (C18:1). Para estes quatro sistemas foram preparadas pequenas quantidades de amostras (2,5 a 4,5 mg) em diferentes composições cuja fração molar do componente mais volátil variara de 0 a 1,0 em intervalos de 0,1. Os coeficientes de fugacidade para os componentes da fase vapor foram calculados usando o método de Hayden e O'Connell (Fredenslund et al., 1977) e o coeficiente de atividade para a fase líquida foi correlacionado pelos modelos tradicionais de gE : NRTL (Renon and Prausnitz, 1968), UNIQUAC (Abrams and Prausnitz, 1975) e Wilson (Prausnitz et al., 1999). Os ajustes dos parâmetros foram então comparados afim de determinar quais dos ajustes representava melhor o ELV. A modelagem termodinâmica é importante para o desenvolvimento de equipamentos para a produção de biodiesel e fundamentais nos processos de purificação. / Abstract:This work will contribute to some unpublished data of phase equilibria of compounds that form the biodiesel, which arouses the interest immediately. Vapor-liquid equilibrium (VLE) data for three binary mixtures of saturated fatty acids have been successfully measured through differential scanning calorimetry (DSC). These data are of great interest to the industries mainly of biodiesel, since processes such as crystallization or separation of undesired components can be minimized from such data. However, changes in the calorimeter pressure cell and the use of hermetic pans with caps with holes (f = 250 µm) have been necessary so that this analytical technique was possible to be applied, showing accuracy in results, shorter sample quantity and operational time. The systems studied at 50 mmHg in this work were: myristic acid (C14:0) + palmitic acid (C16:0), myristic acid (C14:0) + stearic acid (C18:0) e palmitic acid (C16:0) + stearic acid (C18:0). The linoleic acid (C18:2) + oleic acid (C18:1) binary mixture was investigated in the pressure of 8 mmHg. The binary systems were prepared using small quantities (2.5 to 4.5 mg) of samples in different mole fractions varying between 0.0 and 1.0 in relation to the most volatile component of each diagram. The fugacity coefficients for the components in the vapor phase have been calculated using the Hayden and O'Connell's method (Fredenslund et al., 1977) and the activity coefficients for the liquid phase have been correlated to the traditional gE models: NRTL (Renon and Prausnitz, 1968), UNIQUAC (Abrams and Prausnitz, 1975) and Wilson (Prausnitz et al., 1999). The set of parameters were then compared in order to determine which adjustments would best represent the VLE. The thermodynamic modeling is important for the development of equipment for the biodiesel production and purification. / Mestrado / Desenvolvimento de Processos Químicos / Mestre em Engenharia Química
45

Estudo teórico-experimental da transferência de calor e da perda de pressão em um dissipador de calor baseado em microcanais / A theoretical and experimental study on heat transfer and pressure drop in a heat sink based on microchannels

Francisco Júlio do Nascimento 28 May 2012 (has links)
A presente dissertação trata de um estudo teórico-experimental sobre escoamento monofásico e bifásico em um dissipador de calor baseado em microcanais. Este tipo de dissipador de calor tem sido usado para a intensificação da troca de calor em sistemas compactos e de alto desempenho. A intensificação da troca de calor promovida pelo escoamento em microcanais é acompanhada de um incremento na perda de pressão, portanto o estudo destes dois parâmetros é essencial para o entendimento dos fenômenos relacionados e fundamental para o desenvolvimento de ferramentas de projeto para dissipadores de calor baseados em microcanais. Inicialmente, um levantamento bibliográfico extenso sobre a ebulição convectiva em microcanais de reduzido diâmetro foi realizado. Este estudo da literatura trata de critérios de transição entre micro- e macro-escala, padrões de escoamento, métodos de previsão do coeficiente de transferência de calor e perda de pressão. Atenção específica foi dada a estudos de dissipadores de calor baseados em microcanais. Com base nesta análise da literatura, uma bancada experimental foi confeccionada para que dados experimentais de transferência de calor e perda de pressão pudessem ser levantados a partir de um dissipador de calor de microcanais. O dissipador de calor fabricado para este estudo é constituído de 50 microcanais retangulares dispostos paralelamente com 15 mm de comprimento, 100 µm de largura, 500 µm de profundidade e espaçados entre si de 200 µm. Experimentos foram executados para o R134a, velocidades mássicas de 400 a 1500 kg/m²s, título de vapor máximo de 0,35 e fluxos de calor de até 310 kW/m². Como conclusão deste trabalho observa-se perda de pressão elevada em relação aos valores fornecidos pelos métodos de previsão da literatura e um coeficiente de transferência de calor próximo ao estimado pelo modelo de três zonas proposto por Thome et al. (2004). / This study presents a theoretical and experimental investigation on single and two-phase flows in a microchannel based heat sink. Multi-microchannel heat sinks are able of dissipating extremely high heat fluxes under confined conditions. Such characteristics have attracted the attention of academia and industry and actually several studies are being carried out in order to evaluate and optimize such devices. Initially, an extensive investigation of the literature concerning convective boiling in micro-scale channels was performed. This literature review covers transitional criteria between micro- and macro-scale flow boiling, two phase flow patterns, heat transfer coefficient and pressure drop during convective boiling. Special attention was given to studies concerning microchannels based heat sinks. Based on this investigation, an experimental facility was built for performing heat transfer and pressure drop measurements during single-phase flow and flow boiling in microchannel based heat sinks. For this study, a microchannel based heat sink was also manufactured. The heat sink contains 50 rectangular parallel microchannels, 15 mm long, 100 µm wide by 500 µm deep and separated by 200 µm walls. Experiments were performed for R134a, mass velocity of 400-1500 kg/m²s, maximum vapor quality of 0,35 and heat fluxes up to 310 kW/m². The database obtained in the present study was compared against pressure drop and heat transfer coefficient prediction methods from the literature. It was found that no one method is accurate in predicting heat sink pressure drop while heat transfer coefficient results were accurately predicted by the 3-zone model proposed by Thome et al. (2004).
46

Estudo teórico e experimental sobre padrões de escoamento e perda de pressão durante escoamentos monofásicos e bifásicos no interior de tubos com fitas retorcidas / Theoretical and experimental study on flow pattern identification and pressure drop during single and two-phase flow in tubes with twisted tape inserts

Fabio Toshio Kanizawa 14 July 2011 (has links)
A presente dissertação trata de um estudo teórico-experimental sobre escoamento monofásico e bifásico no interior de tubos com fitas retorcidas. Esta técnica tem sido utilizada há várias décadas para a intensificação de troca de calor para escoamento monofásico e evaporação convectiva no interior de tubos. No entanto, com sua utilização, o aumento do coeficiente de troca de calor é acompanhado pelo incremento da perda de pressão. Portanto a compreensão dos fenômenos relacionados aos incrementos da perda de pressão e troca de calor são fundamentais para engenheiros projetistas. Neste estudo, inicialmente, é apresentada uma extensa revisão bibliográfica sobre padrões de escoamento, modelos para estimativa de fração de vazio e metodologias para previsão da perda de pressão em tubos com e sem fitas retorcidas para escoamentos bifásicos e monofásicos. Foram realizados experimentos em bancada experimental utilizando seção de testes com diâmetro interno de 15,9 mm e dois metros de comprimento com fitas apresentando razões de retorcimento de 3, 4, 9, 14 e , a última correspondente ao tubo sem inserto. Os experimentos foram executados para o refrigerante R134a, velocidades mássicas entre 75 e 250 kg/m²s, e títulos de vapor entre 5 e 95% no caso de escoamentos bifásicos. Resultados foram levantados para velocidades mássicas entre 100 e 450 kg/m²s para escoamentos monofásicos. Durante os ensaios foram levantados resultados de perda de pressão e identificados subjetivamente os respectivos padrões de escoamento. Como resultado final deste estudo é proposta uma correlação para previsão da perda de pressão durante o escoamento no interior de tubos com fitas retorcidas. / A theoretical and experimental study on single and two-phase flow inside tubes with twisted tapes inserts is presented. Twisted tape inserts have been used for decades as a technique of heat transfer enhancement. However, their heat transfer enhancement is accompanied by an increase of the pressure drop. Therefore, understanding the pressure drop and heat transfer mechanisms is fundamental for heat exchanger designers in order to optimize these devices when using twisted-tape inserts. Based on these aspects the present study concerns single and two-phase flows inside tubes with twisted tapes. Experiments were performed in an experimental apparatus for a 15.9 mm ID and twisted tape with twist ratios of 3, 4, 9, 14 and , the last one corresponding to a plain tube without tape. For two-phase flow, experiments were conducted for R134a, mass velocities from 75 to 250 kg/m²s and vapor qualities from 5 to 95%. In case of single-phase flow, experiments were performed for mass velocities from 100 to 450 kg/m²s. The experimental campaign was focused on pressure drop and flow pattern subjective identification. Additionally an extensive literature review on flow patterns, superficial void fraction, and methodologies for prediction of the pressure drop in plain tubes with and without twisted-tape inserts during single and two-phase flow is presented. As final result, a correlation for prediction of pressure drop during flow inside tubes with twisted tape inserts is proposed.
47

Efeito da rugosidade superficial na ebulição nucleada de refrigerantes halogenados em tubos horizontais / Effect of surface roughness on nucleate boiling heat transfer of halocarbon refrigerants on horizontal tubes

Elvio Bugança Stelute 12 August 2004 (has links)
O estudo presente constitui uma análise da influência do acabamento superficial no coeficiente de transferência de calor na ebulição nucleada de refrigerantes halogenados. Dados para três superfícies distintas (cobre, latão e aço inoxidável), dois fluidos refrigerantes (R123 e R134a) e pressões reduzidas entre 0,023 e 0,26 são analisados com o intuito de verificar a influência da rugosidade nestes três parâmetros. O efeito da rugosidade foi avaliado com três acabamentos distintos (massa polidora, lixa e jato de areia) cobrindo uma faixa de rugosidades médias variando desde 0,03 até 10,5 micrômetro. Uma análise de diversas publicações da literatura foi levada a cabo, tendo sido particularmente investigadas algumas correlações que consideram o efeito do acabamento superficial em sua estimativa do coeficiente de transferência de calor. As tendências destas correlações são comparadas entre si e com os dados experimentais. A análise dos resultados permitiu levantar tendências inéditas na literatura consultada. A superfície em ebulição recebeu especial atenção com a obtenção de microfotografias e o cálculo de diversos parâmetros de rugosidade. Foram, ainda, investigados efeitos de envelhecimento da superfície, caracterizado pela diminuição do coeficiente de transferência de calor ao longo do tempo de ebulição. / The present research has been focused in an analysis of the effect of surface finishing on nucleate boiling heat transfer coefficient of halocarbon refrigerants. Experimental data for three different surface material (cooper, brass and stainless steel), two refrigerants (R123 and R134a) and reduced pressures between 0.023 and 0.26 have been analyzed aiming to verify the roughness effects on these three parameters. Three different finishing processes (polishing, emery papering and shot pining) have been used to result in an average roughness range from 0.03 to 10.5 micrometer. An analysis of varied publications and some correlations, particularly those which estimate the effect of surface roughness in heat transfer coefficient, has been done. The tendencies from these correlations have been compared with themselves and with experimental data. These results have shown some effects still unpublished. The boiling surface has received an especial attention, micro-photography has been taken and various parameters have been evaluated. Ageing effects, characterized by the reduction of heat transfer coefficient, have been verified and analyzed.
48

Estudo teórico-experimental da ebulição convectiva do refrigerante R-134a em tubos lisos / A theoretical and experimental study of convective boiling of refrigerant R-134a in smooth tubes

Paulo Eduardo Lopes Barbieri 02 September 2005 (has links)
Apresenta um estudo teórico-experimental da ebulição convectiva do fluido refrigerante R-134a no interior de tubos lisos. Os parâmetros físicos disponíveis para medida foram: pressão, temperatura, vazão de refrigerante e potência de aquecimento, os quais, juntamente com o registro fotográfico, foram utilizados para caracterizar os padrões de escoamento e as transições, investigando-se os efeitos do diâmetro do tubo, da velocidade mássica e do fluxo de calor sobre a perda de pressão e a transferência de calor. Os principais padrões de escoamento visualizados foram: o intermitente, o anular e o estratificado, nos quais constatou-se que, as transições são governadas, principalmente, pelos efeitos da velocidade mássica e do diâmetro do tubo. Dentre estes padrões de escoamento, o anular e o estratificado foram modelados analiticamente. O modelo para o escoamento anular foi utilizado na obtenção de correlações para o fator de atrito interfacial e para espessura do filme de líquido. O modelo para o escoamento estratificado foi dividido em duas partes, uma destinada a obter a configuração da interface, a qual se mostrou côncava e a outra destinada à determinação dos fatores de atrito líquido-parede e interfacial os quais foram correlacionados / The research reports a theoretical and experimental study of convective boiling of refrigerant R-134a in smooth tubes. Tests have been carried out to measure the following physical parameters at the test section: mass flow rate, pressure and pressure drop, refrigerant and surface temperatures and the electrical power. In addition to these parameters, a photographic study has been carried out from pictures taken at the test section exit in order to determine the flow regimes that intervene under the imposed operating conditions. Effects over the pressure drop and heat transfer of the mass flow rate, heat flux, quality, and tube diameter have been investigated. Three flow regimes have been found: the intermitent, the stratified and the annular. Flow regime transitions are apparently governed by the mass velocity and tube diameter. The annular and the stratified flow regimes have been semi-empirically modeled using a mechanistic approach. The annular flow model has been applied to develop correlations for two important physical parameters: the interfacial friction factor and the film thickness. Through the stratified model, the shape of the interface has been evaluated along with correlations for the liquid to wall and interface friction factors
49

Comportamento térmico e hidrodinâmico da ebulição convectiva do HFE-7100 em microdissipador de calor baseado em microcanais /

Zago, João Vitor. January 2019 (has links)
Orientador: Elaine Maria Cardoso / Resumo: Dissipadores de calor compactos, baseados em microcanais, têm se mostrado um meio eficaz para o resfriamento de dispositivos de alta densidade de energia, tais como microprocessadores, além de proporcionarem redução de material utilizado para a fabri-cação e do inventário de fluido refrigerante necessário. Sistemas bifásicos que operam com fluidos refrigerantes proporcionam coeficientes de transferência de calor elevados para baixos valores de velocidade mássica e uma distribuição de temperatura mais uni-forme na superfície. O presente estudo teve por objetivo avaliar experimentalmente o desempenho de um dissipador de calor baseado em microcanais, em condições de ebuli-ção convectiva saturada do fluido HFE-7100. O dissipador, em cobre eletrolítico, possui 33 microcanais de seção retangular com dimensões de 10 mm de comprimento, 200 μm de largura, 500 μm de altura e espaçados 100 μm entre si. A eficiência térmica do dissi-pador foi avaliada utilizando como fluido de trabalho o HFE-7100 (fluido refrigerante com baixo ozone depleting potencial, ODP, e global warming potential, GWP). Dados experimentais para o coeficiente de transferência de calor (CTC) e perda de pressão fo-ram obtidos em condições de escoamento monofásico e bifásico saturados, para diferen-tes valores de velocidades mássicas. As condições testadas foram de fluxo de calor im-posto (footprint) variando de 50 a 700 kW/m², com velocidades mássicas do fluido entre 392 e 875 kg/m²s, obtendo coeficientes de transferên... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Microchannel-based heat sinks have been shown to be an effective way of cool-ing high-density energy devices such as microprocessors, as well as reducing the material used to manufacture the exchangers and the required refrigerant inventory. Two-phase flow systems that operate with refrigerant fluids provide high heat transfer coefficients with low mass flux values and more uniform temperature distribution on the surface. The present study aimed to evaluate experimentally the performance of a heat sink based on microchannels under saturated conditions of convective boiling of HFE-7100 fluid. The analyzed heat sink has 33 rectangular section microchannels measuring 10 mm length, 200 μm wide, 500 μm high and spaced 100 μm apart. The heat sink was evaluat-ed using HFE-7100 (low ozone-depleting potential, ODP, and global warming potential, GWP) as working fluid. Experimental data for the heat transfer coefficient and pressure drop were obtained under saturated single and two-phase flow conditions for different values of mass velocities. An experimental apparatus was assembled and validated for the accomplishment of testing. As experimental conditions, the heat flux was applied in a range from 50 to 700 kW/m², with mass flux from 392 and 875 kg/m²s, obtaining a heat transfer coefficient of 60 kW/m² and pressure drop up to 12 kPa. By decreasing the mass flux and the input of the subcooling the HTC increases; the pressure drop increases monotonically with the increase in the mass fl... (Complete abstract click electronic access below) / Mestre
50

Um estudo experimental da ebulição convectiva de refrigerantes no interior de tubos lisos e internamente ranhurados / An experimental study of convective flow boiling of refrigerants inside smooth and microfin tubes

Bandarra Filho, Enio Pedone 29 April 2002 (has links)
A presente pesquisa trata de um estudo experimental da transferência de calor e da perda de carga de fluidos refrigerantes puros e suas misturas em mudança de fase convectiva no interior de tubos lisos e aqueles dotados de ranhuras internas. Para tanto, foi desenvolvido um equipamento experimental cujo componente básico é composto por um tubo horizontal, aquecido por intermédio de uma resistência elétrica do tipo fita, aderida à superfície externa do tubo. As condições de ensaio variaram numa ampla faixa, permitindo cobrir as condições verificadas na maioria das instalações frigoríficas. Os resultados experimentais foram agrupados em duas faixas de velocidades mássicas: elevadas (G > ou = 200 kg/s.m2), onde prepondera o padrão anular de escoamento, e reduzidas (G < 200 kg/s.m2), predominando o padrão estratificado. Os principais parâmetros que afetam o coeficiente de transferência de calor, tais como, velocidade mássica, fluxo de calor, tipo de refrigerante, temperatura de evaporação e diâmetro do tubo foram analisados. O desempenho termo-hidráulico, relativo ao efeito combinado da transferência de calor e da perda de carga dos tubos ranhurados, foi sensivelmente superior quando comparados aos tubos lisos. A análise dos resultados experimentais permitiu a proposição de correlações para a perda da carga, avaliada através do multiplicador bifásico, &#966L, e para coeficiente de transferência de calor, em tubos lisos e ranhurados. As correlações propostas se mostraram adequadas para aplicações práticas, proporcionando desvios reduzidos em relação aos resultados experimentais. Destacam-se as correlações obtidas para o multiplicador bifásico para tubos microaletados e para o coeficiente de transferência de calor para vazões reduzidas em tubos lisos. Diversos registros fotográficos dos principais padrões de escoamento foram levantados, tendo sido importante na análise e entendimento da mudança de fase. / Present research deals with an experimental study of the heat transfer and pressure drop of pure and mixtures of refrigerants undergoing convective boiling inside horizontal smooth and microfin tubes. An experimental apparatus has been developed and constructed whose main component is a horizontal tube electrically heated. Experimental results have been grouped into two mass velocity ranges: the one corresponding to mass velocities lower than 200 kg/s.m2, where the stratified flow pattern is dominant, and that for mass velocities higher than 200 kg/s.m2, where typically the annular flow pattern can be found. Effects over the heat transfer coefficient of physical parameters such as mass velocity, heat flux, diameter, saturation temperature, and refrigerant have been investigated and analyzed. It has been found out that the thermo-hydraulic performance of microfin tubes is better than that of the smooth ones. Empirical correlations have been proposed for both the two-phase flow multiplier and the heat transfer coefficient for different ranges of operating conditions as well as for smooth and microfin tubes. Results from the proposed correlations can be deemed adequate for practical applications given the limited dispersion obtained with respect to their experimental counterpart. Noteworthy are the results obtained from correlations for both the two phase flow multiplier for microfin tubes and the heat transfer coefficient for the lower range of mass velocities in smooth tubes. Finally, worth mentioning is the photographic essay developed in present research involving the flow patterns that occur under convective boiling of refrigerants in horizontal tubes.

Page generated in 0.0344 seconds