• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 89
  • 28
  • 6
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 171
  • 25
  • 17
  • 17
  • 15
  • 14
  • 14
  • 13
  • 12
  • 12
  • 11
  • 11
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Agentes complexantes no controle analitico de tracos de fluoreto por eletrodo ion-seletivo

KATSUOKA, LIDIA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:53Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:57Z (GMT). No. of bitstreams: 1 02809.pdf: 6234365 bytes, checksum: 25107a337d71b51089353992495839d5 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
52

Influência do Hidróxido de Cálcio e do EDTA na Marcação da Infiltração Marginal de Azul de Metileno em Obturações de Canais Radiculares.

Eduardo Nunes 18 June 1999 (has links)
Com o objetivo de avaliar a influência do hidróxido de cálcio e do EDTA na marcação da infiltração marginal de corante azul de metileno a 2% em canais radiculares obturados pela técnica da condensação lateral, foram empregados 188 dentes incisivos centrais superiores humanos extraídos. Após serem instrumentados e impermeabilizados, foram divididos em 3 grupos de 60 elementos cada, sendo que outros 8 dentes foram utilizados como controle. Cada grupo foi dividido em 2 subgrupos, os quais, foram subdivididos em dois, totalizando 12 subgrupos com 15 elementos cada, dessa forma descritos: Grupo I – obturação imediata; em 30 dentes foi aplicado EDTA por 3 minutos antes da obturação; em 30 dentes a obturação foi feita sem a aplicação do EDTA; 30 dentes foram obturados com cimento de óxido de zinco e eugenol e 30 obturados com pasta de hidróxido de cálcio; Grupo II – aplicação de EDTA por 3 minutos e preenchimento de todos os canais com pasta de hidróxido de cálcio (curativo); em 30 dentes o EDTA foi reaplicado após a remoção do curativo, e nos outros 30 dentes não; 30 dentes foram obturados com cimento de óxido de zinco e eugenol e 30 obturados com pasta de hidróxido de cálcio; Grupo III – após a instrumentação, os canais foram preenchidos com pasta de hidróxido de cálcio (curativo) sem a aplicação prévia do EDTA; após a remoção do curativo, em 30 dentes o EDTA foi aplicado e em outros 30 não; 30 dentes foram obturados com cimento de óxido de zinco e eugenol e outros 30 com pasta de hidróxido de cálcio. Posteriormente à imersão em azul de metileno a 2% por 72 horas, os dentes foram seccionados longitudinalmente e as infiltrações mensuradas com o emprego de um microscópio óptico munido de uma ocular micrometrada. Após serem empregados os testes estatísticos pertinentes, foram obtidas as seguintes conclusões: - em relação ao hidróxido de cálcio: como curativo e pasta obturadora, interfere estatisticamente na marcação da infiltração, diminuindo a sua magnitude; em relação ao EDTA: o seu emprego prévio ao curativo de hidróxido de cálcio, melhora o selamento das obturações com óxido de zinco e eugenol; o emprego antes e após o curativo, promove um aumento da infiltração em canais obturados com óxido de zinco e eugenol; em canais obturados com pasta de hidróxido de cálcio, o seu emprego não promove interferências estatisticamente significantes nos resultados. / With the objective of evaluate the influence of calcium hydroxide and EDTA in marginal infiltration of metilen blue 2% in root canals obturated by the laterally condensed technique, were used 188 central superior incisor human teeth. After they were instrumented and impatented, the 188 teeth were divided in 3 groups of 60 teeth each. Each group was divided in 2 subgroups and these were divided again in 2, resulting 12 subgroups with 15 teeth each, this way discribed: Group I: immediate obturation; in 30 teeth was applied EDTA for 3 minutes before obturation; and in the other 30 the obturation was done without application of EDTA. 30 teeth were obturated with zinc oxide and eugenol ciment and 30 were obturated with calcium hydroxide paste; Group II: application of EDTA for 3 minutes and all root canals were filled with calcium hydroxide paste (bandage). In 30 teeth the EDTA was applied again after removing the bandage, but this was not done in the other 30; 30 teeth were obturated with calcium hydroxide paste; Group III: the root canals were filled with calcium hydroxide paste (bandage), without a previous application of EDTA, after they were instrumented. After removing the bandage, the EDTA was applied in 30 teeth one more time but not the other 30; 30 teeth were obturated with zinc oxide and eugenol ciment and the other 30 with calcium hydroxide paste. After the immersion in metilen blue 2% for 72 hours, all the 180 teeth were longitudinally sectionalized and the infiltrations were measured using a stereomicroscope and a micrometric ocular. Statistics tests were done and according with those, the following conclusions were obtained: - calcium hydroxide: As a bandage and as an obturation paste, interferes in the infiltration; its use as a bandage, before obturation, with zinc oxide and eugenol ciment, improves the sealer quality of this last one; - EDTA: Its use before the calcium hydroxide bandage, improves obturation sealings with zinc oxide and eugenol ciment. It use after and before the bandage promotis an infiltration increasing in obturated root canals with zinc oxide and eugenol ciment; in root canals obturated with calcium hydroxide paste, the use of EDTA does not promote significative interferences in the result.
53

CARACTERIZAÃÃO ÃTICA E ESTRUTURAL DE FILMES DE CdS DEPOSITADOS POR BANHO QUÃMICO

Wellington de Queiroz Neves 15 March 2013 (has links)
Neste trabalho estudamos as propriedades Ãticas de filmes de sulfeto de cÃdmio (CdS) crescidos sobre um substrato de vidro. Os filmes foram obtidos por meio da tÃcnica de deposiÃÃo por banho quÃmico (Chemical Bath Deposition, CBD). Os filmes de CdS sÃo preparados numa soluÃÃo aquosa, sob agitaÃÃo, a uma temperatura de 80 oC durante 60 minutos sobre substrato de vidro. Alguns dos filmes foram obtidos com duplo depÃsito em dois banhos sucessivos iguais. Como fonte de Ãons de cÃdmio à usado sulfato de cÃdmio (CdSO4,) como fonte de Ãons de enxofre à usado a tioureia, como tampÃo à usado cloreto de amÃnia, e como agente complexante o Ethylenediamine tetra acetic acid (Edta) em vÃrias concentraÃÃes. ApÃs o crescimento, os filmes foram submetidos a um tratamento tÃrmico no ar nas temperaturas de 300 ou 400 oC por uma hora. Foram realizadas medidas experimentais usando a tÃcnicas de difraÃÃo de raios-X, fototransmissÃo Ãtica UV-VIS e espectroscopia Raman. Os filmes de CdS obtidos possuem estrutura cÃbica e sÃo de coloraÃÃo amarelada, homogÃneos e muito aderentes ao substrato de vidro. SÃo analisados os efeitos da concentraÃÃo de Edta, tratamento tÃrmico no ar, tempo de deposiÃÃo e temperatura de crescimento dos filmes de CdS. Nossos resultados mostram que, sob as condiÃÃes estudadas, os filmes de CdS nÃo possuem fase hexagonal em sua estrutura. O gap dos filmes de CdS està em torno de 2,45 eV, com pequenas variaÃÃes (2,40 â 2,51 eV) devido Ãs condiÃÃes experimentais de crescimento ou tratamento tÃrmico apÃs o crescimento. Observamos o modo LO, de simetria A1, em torno de 300 cm-1 e atà trÃs sobremodos desse fÃnon. Em alguns casos, os espectros Raman aparecem sobre uma larga fotoemissÃo, dependendo das condiÃÃes experimentais.
54

Capacidade de remoção do SMEAR LAYER dos canais radiculares com o uso do ultrassom, CANALBRUSH™ E LASER Nd: YAG através da microscopia eletrônica de varredura

LIMA, Grasiele Assis da Costa 22 February 2013 (has links)
Submitted by Leonardo Freitas (leonardo.hfreitas@ufpe.br) on 2015-04-13T14:36:36Z No. of bitstreams: 2 Dissertaçao Grasiele Lima.pdf: 1061882 bytes, checksum: 1363fae0620e5a9f063191ea45f4d653 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-04-13T14:36:37Z (GMT). No. of bitstreams: 2 Dissertaçao Grasiele Lima.pdf: 1061882 bytes, checksum: 1363fae0620e5a9f063191ea45f4d653 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2013-02-22 / CNPq / Objetivo: comparar a eficiência do Ultrassom, CanalBrush™ e LASER, associado ao EDTA 17%, na remoção de smear layer no terço apical dos canais radiculares. Metodologia: 50 raízes distais de primeiros molares inferiores humanos com processo de rizogênese concluído foram submetidas ao preparo biomecânico utilizando o Sistema ProTaper Universal™ até a lima F5. Os espécimes foram divididos em 5 grupos (n= 10) e submetidos a uma irrigação final com EDTA e diferentes técnicas de agitação: controle negativo, limas ProTaper Universal™, Ultrassom, CanalBrush™ e LASER. Após esse procedimento, os espécimes foram clivados e foram obtidas imagens a partir do microscópio eletrônico de varredura. As imagens foram analisadas e foi atribuído um escore a cada espécime. Os dados foram tabulados e submetidos à análise estatística através dos testes de Kruskal Wallis e de Mann-Whitney com nível de significância de 5%. Resultados: o ultrassom apresentou remoção completa de smear layer em 56,6% dos espécimes e obteve diferença estatisticamente significativa em relação aos demais grupos (p< 0,005). O LASER obteve remoção completa de smear layer em 30% dos espécimes com resultado inferior ao do ultrassom. O Canalbrush™ e a lima ProTaper Universal™ não mostraram diferença estatisticamente significante entre si (p= 0,321); ambos os grupos não obtiveram nenhum espécime com remoção completa de smear layer. Conclusões: o uso do EDTA contribuiu para a remoção da smear layer. O ultrassom apresentou melhor desempenho, seguido do LASER. Porém, nenhuma técnica foi capaz de remover a smear layer totalmente.
55

Agentes complexantes no controle analitico de tracos de fluoreto por eletrodo ion-seletivo

KATSUOKA, LIDIA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:53Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:57Z (GMT). No. of bitstreams: 1 02809.pdf: 6234365 bytes, checksum: 25107a337d71b51089353992495839d5 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
56

Influência do tempo na dosagem de glicemia no plasma fluoreto e plasma EDTA

Saraiva, Heloísa Helena Fonseca De Lima January 2012 (has links)
Submitted by Mirian Silva (mirian.pereira@uniceub.br) on 2015-10-08T23:33:03Z No. of bitstreams: 1 Influencia do tempo (6) ok.pdf: 358016 bytes, checksum: 31f9923438aa951579acb64080ccce3b (MD5) / Made available in DSpace on 2015-10-08T23:33:03Z (GMT). No. of bitstreams: 1 Influencia do tempo (6) ok.pdf: 358016 bytes, checksum: 31f9923438aa951579acb64080ccce3b (MD5) Previous issue date: 2012 / A dosagem da glicemia é empregada para estudo do metabolismo da glicose tanto no controle de produção, consumo e também no armazenamento, assim podem ser diagnosticados os diversos estados de hiperglicemia e hipoglicemia, podendo ser medidos por exames laboratoriais utilizando sangue venoso. É visto que após a coleta do sangue, as células sanguíneas continuam a degradar a glicose gerando um decréscimo de aproximadamente 10mg/dL por hora à temperatura ambiente a não ser que se adicione um preservativo, sendo o fluoreto o mais indicado por ser inibidor da glicólise. Este estudo teve por objetivo comparar o uso de dois anticoagulantes diferentes (fluoreto e EDTA) para avaliar a estabilidade da glicemia em temperatura ambiente e ainda correlacionar as glicemias obtidas para os dois tipos de anticoagulantes determinando a diferença entre elas devido ao fator de tempo. Para a realização do trabalho foram coletadas 30 amostras de sangue total por punção venosa de voluntários de ambos os sexos sem restrição de idade e sem necessidade de jejum. Os resultados obtidos confirmaram que na primeira hora houve a queda de aproximadamente 10mg/dL para os dois anticoagulantes utilizados, seguido de estabilização com o anticoagulante fluoreto e um decréscimo progressivo com o uso do anticoagulante EDTA. Isto concorda com o fato de que o tempo é um fator determinante na dosagem da glicemia influenciando na estabilidade da amostra e na confiabilidade dos resultados podendo gerar resultados não verdadeiros.
57

Tagging - Development of new qNMR methods / Tagging - Die Entwicklung neuer Quantifizierungmethoden in der NMR Spektroskopie

Hafer [geb. Zailer], Elina January 2021 (has links) (PDF)
High-resolution nuclear magnetic resonance (NMR) spectroscopy is used in structure elucidation and qualitative as well as quantitative examination of product components. Despite the worldwide development of numerous innovative NMR spectroscopic methods, several official methods that analyze specific substances and do not represent a holistic analysis, are still in use for the quality control of drugs, food and chemicals. Thus, counterfeit or contaminated products of inferior quality can be brought onto the market and distributed despite previous quality controls. To prevent this, three NMR spectroscopic methods have been developed within the scope of this work (1) to study the peroxide value in vegetable and animal oils, (2) for the qualitative and quantitative analysis of metal cations and (3) to determine the enantiomeric excess in chiral alcohols. In oil analysis, titration methods are used to determine the bulk quality parameters such as peroxide value, which represents the concentration of peroxides. Titrations show several drawbacks, such as the need of a large amount of sample and solvents, cross reactions and the low robustness. Thus, an alternative NMR spectroscopic method was developed to improve the peroxide analysis by using triphenylphosphine as a derivatization reagent, which reacts with peroxides in a stoichiometric ratio of 1:1 forming triphenylphosphine oxide. In the 1H-31P decoupled NMR spectrum, the signals of the unreacted triphenylphosphine and the reacted triphenylphosphine oxide are detected at 7.4 ppm and 7.8 ppm, respectively. The ratio of the two signals is used for the calculation of the peroxide concentration. 108 oil samples with a peroxide value between 1 meq/kg and 150 meq/kg were examined using the developed method. Oils with a very low peroxide value of less than 3 meq/kg showed a relative standard deviation of 4.9%, highly oxidized oils with a peroxide value of 150 meq/kg of 0.2%. The NMR method was demonstrated as a powerful technique for the analysis of vegetable and krill oils. Another 1H NMR spectroscopic method was developed for the qualitative determination of Be2+, Sr2+ and Cd2+, and for the qualitative and quantitative determination of Ca2+, Mg2+, Hg2+, Sn2+, Pb2+ and Zn2+ by using ethylenediamine tetraacetate (EDTA) as complexing agent. EDTA is a hexadentate ligand that forms stable chelate complexes with divalent cations. The known amount of added EDTA and the signal ratio of free and complexed EDTA are used to calculate the concentrations of the divalent cations, which makes the use of an internal standard obsolete. The use of EDTA with Be2+, Sr2+, Cd2+, Ca2+, Mg2+, Hg2+, Sn2+, Pb2+ and Zn2+ result in complexes whose signals are pH-independent, showing cation-specific chemical shifts and couplings in the 1H NMR spectrum that are used for identification and quantification. In the presented NMR method, the limit of quantification of the cations Ca2+, Mg2+, Hg2+, Sn2+, Pb2+, and Zn2+ was determined with 5-22 μg/mL. This method is applicable in the food and drug sectors. The third NMR spectroscopic method introduced an alternative determination of the enantiomer excess (ee) of the chiral alcohols menthol, borneol, 1-phenylethanol and linalool using phosgene as a derivatizing reagent. Phosgene reacts with a chiral alcohol to form carboxylic acid diesters, made of two identical (RR, SS) or two different enantiomers (RS, SR). These two different types of diastereomers can be examined by the difference of their chemical shifts. In the presented method, the integration values of the carbonyl signals in the 13C NMR spectrum are used for the determination of the enantiomer excess. The limit of quantification depends, among others, on the sample and on the non-labelled or 13C-labelled phosgene used for the analysis. In the case of menthol, a quantification limit of ee=99.1% was determined using non-labelled phosgene and ee=99.9% using 13C-labelled phosgene. The 13C NMR method was also applied for the quality control of the enantiomeric purity of borneol, 1-phenylethanol and linalool. The developed 13C NMR method represents a powerful alternative to Mosher’s reagent for investigating the enantiomeric excess in chiral alcohols. This work demonstrates the variety of possibilities of applications for the quantitative nuclear magnetic resonance spectroscopy in the chemical analysis of drugs, food and chemicals using tagging reactions such as derivatizations and complexations. The nuclear resonance spectroscopic methods developed in this research work represent powerful alternatives to the previously used quality control techniques. / Die hochauflösende Kernresonanzspektroskopie findet heute primär Anwendung in derStrukturaufklärung und der qualitativen sowie quantitativen Untersuchung von Produkt-inhaltsstoffen. Trotz der weltweiten Entwicklung von innovativen kernresonanzspektrosko-pischen Methoden sind noch zahlreiche, offiziell anerkannte Methoden zur Qualitätskon-trolle von Arzneimitteln, Lebensmitteln und Chemikalien in Verwendung, die spezifischeSubstanzen kontrollieren und keine ganzheitliche Untersuchung darstellen. Somit könnenverunreinigte, qualitativ minderwertige oder gefälschte Produkte trotz vorheriger Quali-tätskontrollen auf den Markt gebracht und vertrieben werden. Um dies zu verhindern,wurden im Rahmen dieser Arbeit drei kernresonanzspektroskopische Methoden entwickelt,die zur (1) Bestimmung der primären Oxidation in pflanzlichen und tierischen Ölen anhandder Peroxidzahl, (2) zur qualitativen und quantitativen Analyse von Metallkationen und(3) zur Ermittlung des Enantiomerüberschusses in chiralen Alkoholen dienen.In der Ölanalytik werden Titrationsverfahren zur Bestimmung der Bulkqualitätsparameterwie auch der Peroxidzahl, welche die Konzentration an Peroxiden aufzeigt, eingesetzt. Dadie Titration neben dem Einsatz von größeren Mengen an Probenmaterial und Lösungsmit-teln, auch Kreuzreaktionen und eine geringe Robustheit aufweist, wurde eine kernreso-nanzspektroskopische Methode entwickelt, in der Triphenylphosphin als Derivatisierungs-reagenz eingesetzt wird, welches mit Peroxiden im stöchiometrischen Verhältnis von 1:1zu Triphenylphosphinoxid reagiert. Im1H-31P entkoppelten Kernresonanzspektrum wer-den die Signale des nicht reagierten Triphenylphosphins bei 7,4 ppm und des reagiertenTriphenylphosphinoxid bei 7,8 ppm detektiert. Das Verhältnis beider Signale wird in dieKonzentration der Peroxide umgerechnet. 108 Ölproben mit einer Peroxidzahl zwischen 1meq/kg und 170 meq/kg wurden mit der entwickelten Methode untersucht. Hierbei zeigtenÖle mit einer sehr geringen Peroxidzahl von weniger als 3 meq/kg eine relative Standard-abweichung von 4,9%, hochoxidierte Öle mit einer Peroxidzahl von 150 meq/kg 0,2%. Diekernresonanzspektroskopische Methode findet Anwendung in der Untersuchung von Krill-und pflanzlichen Ölen.Eine weitere1H kernresonanzspektroskopische Methode wurde zur qualitativen Analyse. Zusammenfassungvon Be2+, Sr2+und Cd2+und zur qualitatitativen sowie quantitativen Bestimmung vonCa2+, Mg2+, Hg2+, Sn2+, Pb2+und Zn2+entwickelt. Hierbei wurde Ethylendiamintetra-acetat (EDTA) als Komplexbildner verwendet. EDTA ist ein sechszähniger-Ligand, derstabile Chelatkomplexe mit zweiwertigen Kationen bildet. Die definierte Menge an EDTAund das Verhältnis von freier und komplexierter EDTA nach Zugabe der Probe werdenfür die Rückrechnung der Konzentration der Kationen verwendet. Somit ist der Einsatzeines internen Standards obsolet. EDTA komplexiert Be2+, Sr2+, Cd2+, Ca2+, Mg2+, Hg2+,Sn2+, Pb2+und Zn2+zu stabilen Komplexen, deren Signale im Protonen-Kernresonanz-spektrum pH-unabhängige und kationenspezifische chemische Verschiebungen und Kop-plungen aufweisen, die zur Identifizierung und Quantifizierung verwendet werden. DieKoaleszenz der∆undΛKonfigurationen des EDTA-Komplexes mit Be2+, Sr2+und Cd2+führt bei 298K zu einer Signalverbreiterung, die eine Quantifizierung bei den vorliegendenParametern unmöglich macht. Die Kationen Ca2+, Mg2+, Hg2+, Sn2+, Pb2+und Zn2+sindab einer Konzentration von 5-22μg/mL quantitativ in wässriger Lösung quantifizierbar.Diese Methode kann im Lebensmittel- und Arzneimittelbereich eingesetzt werden.Die dritte kernresonanzspektroskopische Methode stellt eine neue Bestimmung des Enan-tiomerüberschusses (ee) in den chiralen Alkoholen Menthol, Borneol, 1-Phenylethanol undLinalool unter Einsatz von Phosgen als Derivatisierungsreagenz vor. Phosgen reagiert miteinem chiralen Alkohol zu Carbonsäurediestern, die aus zwei gleichen (RR, SS) oder zweiunterschiedlichen Enantiomeren (RS, SR) entstehen. Diese zwei Diastereomertypen kön-nen anhand der unterschiedlichen, chemischen Verschiebungen ihrer Signale identifiziertwerden. In der vorgestellten Methode wird das Carbonylsignal integriert und zur Bes-timmung des Enantiomerenüberschusses eingesetzt. Die Bestimmungsgrenze ist hierbeiu. a. von dem eingesetzten Phosgen und der Probe abhängig. Bei Menthol wurdeeine Bestimmungsgrenze mittels nicht markiertem Phosgen von ee = 99,1% und mit-tels13C-markiertem Phosgen von ee = 99,9% ermittelt. Die13C Methode wurde zudemzur Qualitätskontrolle der Enantiomerreinheit von Borneol, 1-Phenylethanol sowie vonLinalool eingesetzt. Hierbei enthielten die käuflich erworbenen Chemikalien (-)-Borneolund (S)-1-Phenylethanol jeweils 1,7% des anderen Enantiomers (+)-Borneol bzw. (R)-1-Phenylethanol. Bei (-)-Linalool konnte ein Enantiomerüberschuss von ee = 66,4% undsomit eine größere Verunreinigung durch (+)-Linalool identifiziert werden. Bei Proben,die einen Enantiomerüberschuss von ee < 95,0% aufweisen, sollte eine potentielle, asym-metrische Induktion mittels Kalibrationskurven anhand von künstlichen Enantiomeren-mischungen vorab untersucht werden. Die entwickelte13C kernresonanzspektroskopischeMethode präsentiert eine leistungsstarke Alternative zur Analyse mittels Mosher’s Reagenzfür die Untersuchung des Enantiomerüberschusses in chiralen Alkoholen.Diese Arbeit weist eine Vielfalt an Möglichkeiten der Anwendungen der quantitativen Kern-resonanzspektroskopie in der chemischen Untersuchung von Arzneimitteln, Lebensmittelnund Chemikalien unter Einsatz von Tagging, wie Derivatisierungen und Komplexierun-gen auf. Die hierbei entwickelten kernresonanzspektroskopischen Methoden repräsentierenleistungsstarke Alternativen zu bisher eingesetzten Techniken der Qualitätskontrolle
58

The Evaluation of Type-M Forager® Sponge Technology to Recycle Soil-Washing Amendments

Fetters, Rhonda Spiess 02 August 2003 (has links)
The purpose of this research was to determine if two commonly used soil-washing extracting agents, namely EDTA and nitric acid, could be recycled and reused in subsequent soil-washing processes. This research focuses on the removal of lead from three real-world soils collected from military installations and the evaluation of a chelating polymer termed Type-M Forager® Sponge to recycle the soil-washing effluent. The results of this experiment indicate that the EDTA soil-washing effluent was as effective at removing lead from soil after two recycle processes as it was during the initial simulated soil-washing process. The nitric acid extracting agent solution, however, was neutralized during the first soil-washing simulation for each of the soils tested. Therefore, the Type-M Forager® Sponge was evaluated and proved to be effective as a waste minimization process for the acid soil-washing effluents.
59

Investigation of Microbiologically Influenced Corrosion (MIC) and Biocide Treatment in Anaerobic Salt Water and Development of A Mechanistic MIC Model

Zhao, Kaili January 2008 (has links)
No description available.
60

Propriedades e adesão de cimentos de ionômero de vidro modificados por resina e vitrocerâmicas bioativas / Properties and adhesion of glass ionomer cements modified by resin and bioactive glass-ceramic

Fagundes, Ticiane Cestari 17 February 2009 (has links)
As vitrocerâmicas bioativas são materiais sintéticos capazes de aderirem quimicamente aos minerais presentes na estrutura dentária. A união dos cimentos de ionômero de vidro modificados por resina (CIVMRs) à dentina pode ser influenciada por diferentes tipos de tratamentos prévios à restauração. Os objetivos deste estudo foram: avaliar a resistência à compressão, a rugosidade e a adesão à dentina de CIVMRs (Fuji II LC e Vitremer) após a incorporação de partículas de vitrocerâmicas bioativas (Biosilicato®); foi ainda, avaliar a resistência à degradação da adesão à dentina dos CIVMRs, utilizando-se EDTA como pré-tratamento dentinário. Para o teste de resistência à compressão foram confeccionados cilindros sendo que 2, 5 e 10 % em peso de partículas de vitrocerâmica bioativa foram incorporadas aos pós dos CIVMRs, armazenados em água destilada por 24h a 37°C até a realização dos testes. A rugosidade dos cimentos experimentais (2% de vitrocerâmica bioativa) e controles foi avaliada por microscopia de força atômica (MFA) após armazenamento a seco e em 100 % de umidade por 1 mês. Para os testes de microtração, as superfícies das cavidades foram tratadas seguindo-se as instruções dos fabricantes ou utilizando-se EDTA. Os espécimes foram restaurados com os CIVMRs experimentais (2% de vitrocerâmica) e controles. Após as restaurações, os espécimes foram armazenados em água por 24h e 7d. Para o teste de degradação, os CIVMRs foram armazenados por 24h, 3m e imersos em 10% de hipoclorito de sódio por 5h. Os dentes foram seccionados em palitos e submetidos ao teste de microtração. ANOVA e teste de múltiplas comparações foram realizados (p<0,05). O modo de fratura foi classificado em adesivo, misto e coesivo e alguns espécimes foram analisados em microscopia eletrônica de varredura (MEV). Apenas os cimentos com 2% de vitrocerâmica bioativa obtiveram resistência a compressão semelhante ao grupo controle. Para os grupos controles, Fuji II LC apresentou-se mais rugoso que o Vitremer e o seu armazenamento à seco aumentou sua rugosidade. A condição de armazenamento, seco ou úmido, não afetou a rugosidade dos CIVMRs experimentais. A vitrocerâmica bioativa aumentou significantemente a adesão à dentina dos CIVMRs após armazenamento por 24h, exceto para o Fuji II LC quando EDTA foi utilizado. A aplicação de EDTA aumentou significantemente os valores de resistência adesiva. No estudo de degradação da união, valores de resistência adesiva significantemente maiores foram obtidos nos grupos onde a dentina foi pré-tratada com EDTA. A resistência adesiva do Fuji II LC à dentina não foi afetada pelos métodos de degradação utilizados. Valores de resistência adesiva significantemente menores foram observados para os espécimes restaurados com Vitremer após os dois métodos de degradação, exceto quando a dentina foi prétratada com EDTA. As falhas do tipo mistas foram prevalentes. Em conclusão, 2% de partículas de vitrocerâmica bioativa podem ser incluídas nos CIVMRs sem afetar suas propriedades mecânicas. A rugosidade dos CIVMRs experimentais não foi afetada pelo meio de armazenamento. A inclusão de vitrocerâmicas bioativas aumentou a resistência adesiva somente após armazenamento de 24h. A utilização de EDTA como pré-tratamento dentinário aumentou a resistência adesiva para todas as condições e preveniu a degradação da interface adesiva do Vitremer. / Bioactive glass-ceramics are synthetic materials capable of chemically bonding to dental structures. Adhesion of resin-modified glass-ionomer cements (RMGICs) to dentin may be influenced by different types of dentin pre-treatments. The objective of this study was to analyze the compressive strength, roughness and adhesion to dentin of RMGICs (Fuji II LC and Vitremer) after the incorporation of bioactive glassceramic particles (Biosilicate). Additionally, the durability of the RMGICs adhesion was analyzed after the application of EDTA as a pre-treatment of dentin. Cylinders of RMGICs with incorporation of 2, 5 and 10 % in weight of bioactive glass-ceramic particles were made for compressive strength, and stored in water for 24h at 37°C. Roughness of control and experimental (2% bioactive glass-ceramic) RMGICs was analyzed by atomic force microscopic (MFA) after storage in dry and humidity conditions for 1 month. For the microtensile test, the surfaces of the cavities were treated following the manufacturers instructions or by applying EDTA. The cavities were restored with control and experimental (2% bioactive glass-ceramic) RMGICs. After restorations, the specimens were stored in water for 24h and 7 days. For the degradation test, the RMGICs were stored for 24h, 3 months or immersed in 10% NaOCl for 5h. Teeth were sectioned in beams and submitted to microtensile test. ANOVA and multiple-comparisons tests were used (p<0.05). Mode of failure was classified in adhesive, mixed and cohesive, some specimens were analyzed by scanning electronic microscopic. Only the RMGICs with 2% of bioactive glassceramic obtained compressive strength similar to the control RMGICs. The storage conditions, dry or humidity, did not affect the roughness of experimental RMGICs. Bioactive glass-ceramic significantly increased the adhesion to dentin of RMGICs after storage for 24h, except for Fuji II LC when EDTA was applied. The application of EDTA significantly increased the values of bond strength. For the degradation study, high values of bond strength were also observed in groups where the dentin was pre-treated with EDTA. The bond strength of Fuji II LC to dentin was not affected by the degradation methods. Vitremer specimens presented significantly lower bond strength values after degradation methods, except when EDTA was applied. Mixed failures were the most prevalent in all groups. In conclusion, 2% of bioactive glassceramic particles may be included in RMGICs without affecting their mechanical properties. Roughness of experimental RMGICs was not affected by storage conditions. The incorporation of bioactive glass-ceramic increased the bond strength after storage for 24h. The application of EDTA as a pre-treatment of dentin increased the bond strength for all conditions studied and prevented the degradation of adhesive interface of Vitremer.

Page generated in 0.0409 seconds