• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Development of luminescent bolometers and light detectors for neutrinoless double beta decay search / Développement de bolomètres luminescents et détecteurs de lumière pour la recherche de la double désintégration bêta sans émission de neutrinos

Tenconi, Margherita 28 September 2015 (has links)
L'étude de la double désintégration bêta sans neutrinos joue un rôle important dans plusieurs questions en physique des particules et cosmologie. Ce processus nucléaire hypothétique viole la conservation du nombre leptonique par deux unités et jusqu'à présent il est le seule moyen pratique pour dévoiler la nature du neutrino : sa détection implique forcement que neutrino et antineutrino sont la même particule. En outre, le taux de décroissance est sensible à la masse efficace de Majorana du neutrino, du coup à l'échelle absolue des valeurs propres de la masse et leur hiérarchie. La marque expérimentale de la DDB0ν est un pic monochromatique dans le spectre énergétique de la somme des deux électrons émis. Le but des expériences de prochaine génération est une sensibilité sur la masse efficace du neutrino de l'ordre de dizaines de meV, c'est-à-dire demi-vies de l'ordre de 10²⁷-10²⁸ années : en pratique, il s'agit de construire des sources de quelques centaines de kg d'isotope candidat, au moins, et les sonder par des détecteurs très efficients, tout en gardant le bruit de fond dans la région énergétique d'intérêt au niveau d'un coup/tonne/an. Les bolomètres luminescents sont une technique prometteuse vu leur excellentes résolutions énergétiques, haute efficacité de détection, ample choix pour les matériaux et extensibilité modulaire à grande échelle; de plus, grâce à la détection simultanée de chaleur et lumière produites par l'interaction des particules, il est possible de discriminer les contaminations α, dangereuse source de bruit aux énergies d'intérêt pour plusieurs noyaux candidats à la DDB0ν. Cette thèse a été effectuée dans le contexte de l'expérience LUMINEU : une expérience pilote qui a pour but la construction d'une expérience de prochaine génération basée sur les bolomètres scintillants en molybdate de zinc, pour l'étude de l'isotope candidat ¹⁰⁰Mo. En vue de la construction d'une expérience à grande échelle, il est nécessaire d'effectuer des caractérisations systématiques pour s'assurer des performances et de la reproductibilité des détecteurs et leurs composantes. La disponibilité d'installations expérimentales en surface, facilement accessibles, est souhaitable pour des tests routiniers : j'ai mené la plupart des expériences au CSNSM, où j'ai aussi travaillé à l'installation d'un nouvel cryostat à dilution basé sur la technologie du Pulse-Tube. Une partie de ma thèse a concerné l'étude de détecteurs bolométriques de lumière aux absorbeurs en germanium et thermomètres NTD (thermistors Neutron Transmutation Doped) : une structure standard pour LUMINEU a été établie et on a mesuré les performances des bolomètres telles que sensibilité, résolution énergétique, bruit de base et reproductibilité. Les résultats sont satisfaisants en vue d'un emploi dans une expérience avec bolomètres scintillants, bien que la configuration soit très sensible à la microphonie. En outre, j'ai testé avec succès des détecteurs bolométriques de lumière exploitants l'effet Neganov-Luke, qui augmente le rapport signal-bruit au niveau compatible avec la détection de la lumière Cherenkov pour la discrimination des événements. Une autre partie a vu la caractérisation des bolomètres scintillants en molybdate de zinc avec masse allant jusqu'à environ 300 g : couplés aux capteurs de lumière susmentionnés et lus par thermistors NTD, ils ont été refroidis en surface au CSNSM et en endroit souterrain à Modane, dans l'installation de l'expérience EDELWEISS pour la Matière Noire. Grâce à la détection simultanée de lumière et chaleur, les interactions des particules β/γ sont séparées des contaminations α. Les résultats démontrent que la caractérisation de bolomètres massifs, presque la taille cible des détecteurs finaux, est possible même en surface, en dépit du rayonnement cosmique. En outre, ces tests ont permis d'optimiser la compatibilité de l'installation de Modane avec les exigences des bolomètres scintillants pour la recherche de la DDB0ν. / Neutrinoless Double Beta Decay (0νDBD) is regarded as an important key in the decryption of some hot astroparticle and cosmological enigmas: it violates lepton number by two units and it is currently the only known practical way to shed light on the neutrino nature, being possible only in case of a Majorana neutrino, identical to its antiparticle. Moreover, the 0νDBD rate is sensitive to the effective neutrino mass, so it would be useful to define the absolute neutrino mass scale and hierarchy. The experimental footprint of 0νDBD is a monochromatic peak in the sum energy spectrum of the two emitted electrons. Next-generation experiments aim at reaching a sensitivity on the effective neutrino mass of the order of ten meV, corresponding to half lives in the range 10²⁷-10²⁸ years: this means to be able to gather, at least, a few hundred kilograms of 0νDBD candidate isotope source and to efficiently scrutinize it with very sensitive detectors. Meanwhile, background levels in the energy region of interest of the 0νDBD signal should be lowered to less than one count/ton/y. Cryogenic luminescent bolometers are a promising technique for 0νDBD search, as they feature excellent energy resolutions, high detection efficiency, flexibility in the material choice and easy scalability to large modular experiments; furthermore, the simultaneous read-out of heat and light signals produced by particle interactions provides an active discrimination method against the dangerous α contaminations, populating the 0νDBD energy region of several interesting candidate isotopes. The work presented in this dissertation was carried out in the context of the LUMINEU project: a pilot experiment focused on zinc molybdate scintillating bolometers, to define the strategies for the construction of a next-generation experiment based on the 0νDBD candidate ¹⁰⁰Mo. In view of the construction of a large 0νDBD experiment, involving hundreds of modules, systematic cryogenic measurements have to be performed to ensure good performance and reproducibility of the detectors and their components. Aboveground facilities are preferred for routinary tests because of their easier accessibility: most of the tests were carried out at CSNSM, where I also worked on the setup of a new cryogenic apparatus, based on the Pulse-Tube technology. One part of my thesis work saw the study of bolometric light detectors based on germanium absorbers and Neutron Transmutation Doped (NTD) thermometers: a proper design was developed in view of LUMINEU and the devices were characterized in terms of sensitivity, energy resolution, baseline noise and reproducibility. The results are compatible with a 0νDBD search final experiment, though this detector configuration is very sensitive to vibrational noise. In addition, the feasibility of bolometric light detectors based on NTD thermometers and Neganov-Luke amplification was investigated, demonstrating that this technique can actually boost the signal-to-noise gain to a level compatible with event discrimination based on Cherenkov light detection. Another part of my work dealt with the test of scintillating zinc molybdate bolometers of mass up to ~300 g, coupled to the aforementioned light detectors and operated both in the aboveground facilities at CSNSM and underground at Modane, in the cryostat of the EDELWEISS Dark Matter search experiment. Good event discrimination capability was achieved: thanks to double read-out of heat and light, it is possible to identify α particles, the threatening background for 0νDBD interests, against β/γ interactions. The results proved the possibility to pre-characterize aboveground detectors of mass close to the one of a final experiment module, despite the high cosmic rays rates. Besides, the measurements opened the way to the mutual compatibility of the underground setup, conceived for another kind of experiment, and LUMINEU 0νDBD search detectors.
2

Calibration d’un détecteur HVeV en utilisant des neutrons de 56 keV

De Brienne, François 08 1900 (has links)
L'un des grands mystères de la physique qu'il nous reste à élucider est d'identifier de quoi est composée la matière sombre. L'expérience SuperCDMS a décidé de se pencher sur la question il y a plus de 20 ans. Nous utilisons des détecteurs semi-conducteurs qui mesurent le signal de phonons engendré par des événements de recul.Nous mesurons également l'énergie déposée sous forme de d'ionisation à l'aide de l'effet Neganov-Trofimov-Luke (NTL) qui produit des phonons d'énergie totale proportionnelle à l'énergie d'ionisation initiale. Pour ce faire, nous appliquons un voltage sur le détecteur qui amplifie également le signal par un facteur proportionnel au voltage appliqué. Nous sommes allés à TUNL en Caroline du Nord, afin de calibrer notre détecteur HVeV fait d'un cristal de silicium. Le but de cette calibration est de déterminer le taux d'ionisation produit par des reculs nucléaires produits par le faisceau de neutrons fourni par TUNL. Cette mesure est importante puisque le taux d'ionisation est atténué pour le recul nucléaire par rapport au recul électronique et qu'il détermine l'amplification du signal par l'effet NTL. Nous avons utilisé des scintillateurs liquides couplés à des PMTs afin de déterminer l'énergie déposée dans le HVeV en les positionnant à des angles de diffusion précis. Nous avons jusqu'ici uniquement effectué l'analyse des données pour lesquelles il n'y a pas d'amplification NTL. Par conséquant, nous ne pouvons pas encore déterminer le taux d'ionisation. Cependant, nous concluons que notre méthode d'analyse est valide et que l'énergie déposée dans le HVeV est bien celle qui correspond aux angles de diffusion auxquels nous avions placé nos PMTs. / One of the biggest mysteries left to be solved in physics is the question of what dark matter is made of. The SuperCDMS experiment decided to explore this question and has done so for the last 20 years. We use semiconducting detectors that measure phonon signals generated by recoils. The HVeV detectors also use the Neganov-Trofimov-Luke (NTL) effect to generate a phonon signal proportional to the ionization signal that is also produced by the recoil. To do so, we apply a voltage bias the HVeV detector, which also amplify the signal by a factor proportional to the bias. We went to TUNL in North Carolina to calibrate our HVeV detector, made of a silicon crystal. The goal of the experiment is to determine the ionization yield of the nuclear recoil produced by the neutron beam provided to us by TUNL. This measurement is important since the ionization yield is dampened for nuclear recoil compared to electronic recoil and is linked to the gain of the signal in the HVeV. We use liquid scintillators coupled to PMTs to determine the energy deposited in the HVeV using the scattering angle between the HVeV and the chosen position of the PMTs. At this point, we only have the analyses for the data with no NTL gain, meaning that we do not yet have a measure for the ionization yield. Still, this analysis allowed us to validate our analysis method and the energy deposited in the HVeV for coincident events with PMTs of different position.
3

Production de plasmons et degré d’ionisation pour des reculs nucléaires dans les détecteurs de matière sombre au silicium de SuperCDMS

Michaud, Émile 08 1900 (has links)
SuperCDMS (Super Cryogenic Dark Matter Search) est une expérience de détection directe de la matière sombre qui utilise des détecteurs cryogéniques au silicium et au germanium capables de mesurer des dépôts d'énergie aussi petits que quelques eV. L'un des défis les plus importants de la recherche de la matière sombre est de réussir à bloquer les nombreux bruits de fond. Une de ces sources de bruit de fond est la production de plasmons par la diffusion Compton, un phénomène ne déposant généralement qu'une dizaine d’eV et affectant surtout les détecteurs à semi-conducteurs. Dans cet ouvrage, nous allons estimer le taux de production de ces plasmons et démontrer qu'il est primordial de tenir compte de ce bruit de fond avant de pouvoir affirmer avoir trouvé la matière sombre. Un autre enjeu majeur de SuperCDMS est l'étalonnage de ses détecteurs à très faible énergie. En effet, la matière sombre est supposée interagir avec le noyau des atomes. Toutefois, il n'existe présentement aucune donnée sur le degré d'ionisation pour des reculs nucléaires de moins de 0,7 keVnr dans le silicium, où keVnr représente l'énergie déposée en keV lors d'une collision nucléaire (nr). Dans la deuxième partie de cet ouvrage, nous allons montrer comment l'expérience IMPACT (Ionization Yield Measurement with Phonons At Cryogenic Temperature), une sous-expérience de SuperCDMS composée de membres de SuperCDMS, compte mesurer ce degré d'ionisation pour des reculs nucléaires entre 0,1 et 4 keVnr dans le silicium. Connaître ce degré d'ionisation est d'une grande importance pour SuperCDMS car il permet de reconstruire l'énergie déposée par une particule de matière sombre lorsqu'elle effectue une collision nucléaire dans ses détecteurs de matière sombre. / SuperCDMS (Super Cryogenic Dark Matter Search) is an experiment for the direct detection of dark matter that uses cryogenic silicon and germanium detectors which can measure energy deposition as low as a few eV. One of the biggest challenges in the search for dark matter is to block the various background events. One of those background source is the excitation of plasmons by Compton scattering, a phenomenon that generally deposits about ten eV and which affects mainly semiconductor detectors. In this work, we will estimate the production rate of plasmons and argue that we must understand this background in order to claim evidence of dark matter. One of SuperCDMS's other challenges is the calibration of its detectors at very low energy. Indeed, dark matter is known to interact with the atom's nucleus, but unfortunately, there is no data at the moment about the ionization yield of nuclear recoils below 0,7 keVnr in silicon, where keVnr is the energy deposited in keV in a nuclear recoil (nr). In the second part of this work, we will show how the IMPACT experiment (Ionization yield Measurement with Phonons At Cryogenic Temperature), a sub-experiment of SuperCDMS composed of members of SuperCDMS, aims to measure the ionization yield for nuclear recoils between 0,1 and 4 keVnr in silicon. It is important for SuperCDMS to know this ionization yield to reconstruct the energy deposited in their detectors by a nuclear recoil from a dark matter particle.

Page generated in 0.0398 seconds