• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 930
  • 14
  • 12
  • 12
  • 12
  • 11
  • 8
  • 4
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 973
  • 347
  • 300
  • 237
  • 208
  • 203
  • 201
  • 199
  • 180
  • 161
  • 155
  • 127
  • 116
  • 108
  • 104
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Localização de faltas em alimentadores de distribuição de energia elétrica usando medições esparsas de tensões /

Pereira, Rodrigo Aparecido Fernandes. January 2007 (has links)
Orientador: José Roberto Sanches Mantovani / Banca: Antonio Padilha Feltrin / Banca: Rubén Augusto Romero Lázaro / Banca: Denis Vinicius Coury / Banca: Walmir de Freitas Filho / Resumo: Neste trabalho, é proposto um algoritmo para localização de faltas em alimentadores radiais aéreos de distribuição de energia elétrica. A técnica proposta aplica-se a alimentadores trifásicos com cargas desequilibradas, que podem possuir ramais laterais trifásicos, bifásicos e monofásicos. As equações da rede que compõem esta técnica foram desenvolvidas com base nos métodos de fluxo de potência do tipo varredura (backward/forward sweep), o que a torna uma ferramenta eficiente e de baixo esforço computacional. No desenvolvimento da mesma, considera-se que haja disponibilidade de medições de tensões no nó inicial do alimentador e também medições esparsas de tensão em alguns pontos ao longo do alimentador de distribuição. Esta técnica apresenta algumas vantagens quando comparada com as técnicas convencionais para localização de faltas que utilizam o deslocamento do local da falta na rede. Nela eliminam-se, dos possíveis locais de falta, os pontos que estão em ramais laterais geograficamente distantes do verdadeiro local da falta e que poderiam ser indicados pelos métodos convencionais de localização da faltas. Adicionalmente à técnica para localização de faltas, é proposto um modelo matemático de programação binária para fazer a alocação otimizada de medidores esparsos de tensões ao longo do alimentador com o propósito de melhorar a precisão do algoritmo desenvolvido, a partir da técnica proposta para a localização de faltas. Neste modelo matemático, busca-se manter a melhor relação custo-benefício para as empresas de energia, em termos de investimentos, custos operacionais e melhorias dos seus índices de confiabilidade, com a localização eficiente de faltas em suas redes de distribuição. Para a solução deste modelo matemático, propõe-se... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: An algorithm for fault location on overhead and radial electric power distribution feeders is proposed in this work. The proposed technique is able to be applied to three-phase feeders containing unbalanced loads. Also, the proposed technique has the ability to deal with feeders which has three-, two- or single-phase laterals. Equations that describe the network are derived based on the backward/forward sweep load flow methods. This characteristic makes the proposed fault location technique an efficient and fast computational tool. In order to develop this technique, it was considered that voltage measurements are available at the sending node of the feeder, as well sparse voltage measurements at some places on the feeder. Thus, this technique presents some advantages in comparison to the traditional technique for fault location which finds the faulty point by means of sliding the analyzed point on the network. By using traditional techniques, points located geographically far from the actual faulty point can be indicated as a faulty point. The proposed technique eliminates these points from the results. Additionally to the proposed technique, a binary programming model is presented for carrying out the optimized placement of voltage measurement devices along the feeder. The goal of this binary programming model is to enhance the accuracy of the proposed algorithm for fault location. This mathematical model is aimed at keeping the best costbenefit rate for the electric utilities, in terms of operational costs and improvements of reliability indices by means of an efficient fault location. A dedicated genetic algorithm is proposed for solving the optimization model. Results and simulation analyses are presented in order to validate the efficiency... (Complete abstract click electronic access below) / Doutor
152

Síntese e propriedades de filmes finos multiferróicos de BiFeO3 /

Masteghin, João Francisco Vieira. January 2018 (has links)
Orientador: Eudes Borges de Araújo / Resumo: Foram preparados filmes finos, de Ferrita de Bismuto (BiFeO3), considerado um dos principais multiferróico que são classes de materiais que apresentam ferroeletricidade e ferromagnetismo simultaneamente. Os filmes foram preparados por um rota química chamada de Sol-gel modificado, variando-se a quantidade de % de mol do Bismuto, depositados em substratos de platina Pt/TiO2/SiO2/Si(100), variando-se a temperatura de cristalização entre 400°C a 600°C, com o objetivo de eliminar algumas fases indesejadas encontradas na literatura. Alguns filmes finos passaram pelo tratamento térmico em atmosférica de O2, com o intuito de diminuir a condutividade, causada pelas vacâncias de oxigênio no material. Pelos resultados obtidos foi possível conseguir filmes finos sem as fases indesejadas e com condutividade não tão alta, sendo possível realizar análises elétricas. Assim, tornou-se possível analisar o comportamento da permissividade, impedância e condutividade em função do campo aplicado e da temperatura. Com tais resultados mostra-se a indicação de polarização iônica nestes filmes. Eles apresentam uma energia de ativação parecida com filme finos encontrados na literatura. Além disso, também mostra que o comportamento das propriedades físicas são os mesmos quando varia a temperatura e o campo. / Abstract: Bismuth Ferrite (BiFeO3) thin films were prepared, considered one of the main multiferroic that are classes of materials that present ferroelectricity and ferromagnetism simultaneously. The films were prepared by a chemical path called modified sol-gel, varying the amount of Bismuth mol percentage, deposited on Pt/TiO2/SiO2/Si(100) platinum substrates, varying the crystallization temperature between 400 °C to 600 °C, with the aim of eliminating some unwanted phases found in literature. Some thin films underwent the thermal treatment in atmospheric O2, in order to reduce the conductivity, caused by the oxygen vacancies in the material. By the results obtained, it was possible to obtain thin films without the undesired phases and with not so high conductivity, being possible to perform electrical analysis. This way it was possible to analyze the behavior of the permissiveness, impedance and conductivity in function of the applied field and temperature. With these results, it is shown an indication of ionic polarization in these films. They have an activation energy similar to thin films found in literature. It is also shown that the behavior of the physical properties are the same when temperature and the field change. / Mestre
153

Desenvolvimento de sensores eletromagnéticos para medição de descargas parciais nos enrolamentos estatóricos de hidrogeradores / Development of electromagnetic sensors to measurement of partial discharges in hydrogenerators stator windings

BRASIL, Fernando de Souza 14 April 2016 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-01-27T15:44:59Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_DesenvolvimentoSensoresEletromagneticos.pdf: 7557574 bytes, checksum: ca82d86bbde977707b8a99aaee256364 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-01-30T12:31:41Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_DesenvolvimentoSensoresEletromagneticos.pdf: 7557574 bytes, checksum: ca82d86bbde977707b8a99aaee256364 (MD5) / Made available in DSpace on 2017-01-30T12:31:41Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_DesenvolvimentoSensoresEletromagneticos.pdf: 7557574 bytes, checksum: ca82d86bbde977707b8a99aaee256364 (MD5) Previous issue date: 2016-04-14 / Paradas de máquinas não planejadas causadas por falhas na isolação elétrica de equipamentos do sistema elétrico de potência são um grande problema, pois contabilizam elevadas perdas para planta e comprometem os indicadores de desempenho devido extenso período de parada da unidade geradora necessário para restauração da função geração. A fim de solucionar esse problema, vários pesquisadores e estudiosos da área de grandes máquinas rotativas descobriram que estas falhas estavam frequentemente relacionadas com o aumento do nível de descargas parciais (DP) da isolação elétrica da máquina. As ocorrências das DP nos sistemas isolantes dos equipamentos de alta tensão são sintomas de fragilidade na sua suportabilidade dielétrica, cuja evolução pode ocasionar graves consequências para o equipamento. As DP podem ser detectadas através da medição de quantidades associadas a pulsos de corrente, sinais de rádio frequência (ondas eletromagnéticas), sinais acústicos, entre outros. Entre esses métodos, a detecção de ondas eletromagnéticas irradiadas pelas DP vem demonstrando ser uma técnica confiável para acompanhar processo de evolução do defeito. Em comparação com outras técnicas, tais como, os métodos de detecção baseados em acopladores capacitivos (método convencional), o uso de sensores eletromagnéticos de banda larga é não invasivo para isolamento. Neste sentido, este trabalho tem como objetivo mostrar a avaliação de três diferentes sensores eletromagnéticos de ultra alta frequência, do inglês, Ultra High Frequency (UHF) projetados para serem instalados nos hidrogeradores. Os sensores utilizados nos experimentos são os seguintes: acoplador direcional de microfita; antena loop e antena log-periódica. Os sensores foram avaliados através de ensaios de alta tensão para medição de descargas parciais, em que foram avaliados todos os tipos de descargas encontrados nos hidrogeradores, como descargas internas, delaminações, descargas de ranhura, descargas barra-barra e de superfície, e através do ensaio de envelhecimento acelerado. Os resultados obtidos no laboratório mostraram que o acoplador direcional apresentou uma grande sensibilidade para todos os tipos de descargas simuladas, cujo os resultados foram validados pela antena log-periódica, e a antena loop foi a que apresentou menor sensibilidade. Os resultados também mostram que é possível identificar as descargas através das características UHF. A evolução dos níveis de DP foi avaliada através do acoplador direcional durante o ensaio de envelhecimento acelerado, foi possível observar o aparecimento de dois tipos de descargas, delaminações e corona, os resultados foram similares aos medidos pelo acoplador capacitivo. / Stops machines unplanned caused by faults in the electrical insulation of the power electric system equipment is a big problem, because account for high losses to plan and undertake performance indicators due long stop period generating unit necessary for the generation function restoration. In order to solve this problem, many researchers and scholars in the field of large rotating machines found that these failures were often related to the increased level of partial discharges (PD) of electrical insulation of the machine. Occurrences of PDs in insulating systems of high voltage equipment are symptoms of weakness in their dielectric withstand, whose evolution can cause serious consequences for the equipment. The PDs can be detected by measuring quantities associated with current pulses, radio frequency signals (electromagnetic waves), acoustic signals, among others. Among these methods the detection of electromagnetic waves radiated by PDs are proving to be a reliable technique to follow the default process of evolution. In comparison with other techniques such as the detection method based on capacitive couplers (conventional method), the use of electromagnetic broadband sensors is not invasive to isolation. In this way, this paper aims to show the evaluation of three different electromagnetic sensors of Ultra High Frequency (UHF) designed to be installed in hydrogenerators. The sensors used in the experiments are: microstrip directional coupler, loop antenna and log-periodic antenna. The sensors were evaluated by high-voltage tests to measure partial discharges which were evaluated all kids of discharges found in hydrogenerators, like internal discharges, delaminations, slot discharge, bar-bar and surface discharges, and through the accelarated aging test. The results obtained in the laboratory demonstrated that the directional coupler showed a high sensibility to all types os simulated discharges which results were validated by log-periodic antenna, and the loop antenna showed a low sensibility. The results also demonstrated that is possible to identify discharges through the UHF characteristics. The evolution of the PDs levels were evaluated through the directional coupler during the accelarated aging test, it was possible to observe the appearance of two types of discharges, delaminations and corona, the results were similar to those measured by the capacitive coupler.
154

Dimensionamento de instalações elétricas

Bessa, Luís Carneiro da Silva January 2012 (has links)
Projecto realizado na empresa JPM - Automação e Equipamentos Industriais, orientado pelo Nuno Rodrigues e Rui Henriques / Tese de mestrado. Mestrado Integrado em Engenharia Electrotécnica e de Computadores. Faculdade de Engenharia. Universidade do Porto. 2012
155

Aplicação de técnica de linearização por partes a problemas de planejamento da operação de sistemas hidrotérmicos

Soares, Bráulio Rangel de Castro January 2017 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2017. / Made available in DSpace on 2017-11-28T03:25:13Z (GMT). No. of bitstreams: 1 348689.pdf: 5985928 bytes, checksum: f2af7ebfd319b07a5e4e0726b78042ad (MD5) Previous issue date: 2017 / O planejamento da operação do sistema elétrico brasileiro é feito de forma centralizada. Devido à matriz energética predominantemente hídrica, tal planejamento é feito considerando horizontes de estudo de até 10 anos e a natureza estocástica das vazões afluentes dos rios. Busca-se, desta forma, otimizar os custos de geração. No entanto, num ambiente competitivo é necessário encarar o problema do ponto de vista dos diversos agentes que fazem parte do sistema, porque os interesses desses agentes não são os mesmos. Um dos agentes é o produtor de energia elétrica, que nem sempre tem seus interesses atendidos. Uma questão importante para um produtor é como definir sua estratégia de participação no mercado de energia elétrica, de forma a atender as suas próprias metas econômicas. Este é o que se conhece como ?o problema do produtor", que usa informações advindas do despacho das usinas do sistema. Para analisar as vantagens de se adotar as soluções obtidas ao se resolver esses problemas matemáticos, é necessário modelá-los de forma adequada. Além disso, é preciso garantir que as soluções obtidas para esses problemas através de métodos de otimização são as melhores possíveis. Os problemas de despacho centralizado e do produtor possuem funções não convexas em suas formulações, assim como a maioria das modelagens de fenômenos encontrados na natureza. Infelizmente os métodos de solução de problemas de otimização não convexos não garantem uma solução ótima global. Assim, se torna necessária a reformulação desses problemas matemáticos de maneira que suas soluções ótimas globais possam ser obtidas pelos métodos de otimização existentes. Este trabalho analisa o uso de uma técnica de linearização por partes, a Combinação Convexa Desagregada, para obter as soluções ótimas globais dos problemas de despacho centralizado e do produtor. / Abstract : The planning of the operation of the Brazilian electrical system is carried out in a centralized manner. As this is a predominantly hydro system, the dispatch is obtained using a planning horizon of 10 years and taking into consideration the stochastic nature of water inflows. However, it is necessary to face the problem of producing electrical energy in an efficient manner from the points of view of all the agents that participate in this process, because every agent has its own objectives. One of these agents is the power producer. An important issue for such agent is to determine the best strategy to participate in the electric power market in order to meet its own economic goals. This is known as ?the problem of the producer", which, to be solved, uses information from the power dispatch. To evaluate the advantages of adopting, in system planning, the solutions obtained by solving such mathematical problems, special care must be taken when formulating these problems. It is also important to ensure that the solutions obtained for these problems are the best possible ones. The dispatch problem and the producer problem are represented using nonconvex functions, as it occurs with other phenomena found in nature. Unfortunately, most of the optimization methods are not able to obtain the global optima of nonconvex problems. Thus, it is necessary to reformulate such problems in order to obtain their best solutions. This work evaluates the use of a piecewise linearization technique, the Disaggregated Convex Combination, in the solution of the power dispatch problem and the producer problem.
156

Um modelo alternativo baseado em conjuntos nebulosos aplicado ao planejamento da compensação reativa em redes de distribuição que contem cargas especiais

Penha, Fernando Diniz 08 November 2000 (has links)
Orientador : Carlos Alberto F. Murari / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-28T02:49:32Z (GMT). No. of bitstreams: 1 Penha_FernandoDiniz_D.pdf: 5199839 bytes, checksum: 8f72e811cae27b11515175227f6ef6cc (MD5) Previous issue date: 2000 / Resumo: Este trabalho propõe um modelo de decisão baseado em conjuntos nebulosos para a alocação e dimensionamento de bancos de capacitores-shunt em redes de distribuição de energia elétrica na presença de fontes geradoras de harmônicos (cargas especiais). A característica principal desta metodologia é a incorporação de uma estrutura de preferências do planejador em um adequado processo de decisão no âmbito do planejamento da compensação reativa em redes elétricas que contenham cargas especiais, o que se dá através de uma modelagem baseada em conjuntos nebulosos, permitindo um tratamento matemático das incertezas e/ou imprecisões inerentes ao raciocínio humano. Uma rotina de cálculo de fluxo de carga harmônico, baseada em uma modelagem trifásica da rede elétrica é utilizada como ferramenta computacional para a solução do estado da rede em cada etapa do planejamento e para a definição do universo de discurso do problema de tomada de decisão. Testes foram realizados em algumas redes de distribuição típicas que contêm uma ou mais fontes harmônicas, sob diferentes condições de operação e diferentes níveis de preferência do planejador com o intuito de avaliar as potencialidades e a coerência da aplicação da metodologia proposta / Abstract: This work proposes a decision model which is based on fuzzy sets for location and sizing of shunt capacitors on Distribution Systems Networks in presence of sources harmonics (loads specials). The main characteristic of this methodology is to incorporate a planner preferences structure into an appropriate decision process on scope of reactive compensation planning in power systems which contain specials loads by a model based in fuzzy sets allowing an mathematic treatment of fuzziness and/or imprecision's inherent on human judgment. A routine of harmonic load flow calculus which is based on three-phase model of network is used for to frnd their state solution in each stage of planning and to determine the universal set of decision making problem. Simulations were performed in some typical distribution power systems which contains one or varlous harmonics sources under distinct conditions of operation and levels preferences of the planner with objectives of to evaluate the potentialities and the coherence of the proposed methodology / Doutorado / Doutor em Engenharia Elétrica
157

Estudo da rugosidade eletronica em capacitores MOS nanometricos

Lopes, Manoel Cesar Valente 28 July 2018 (has links)
Orientador: Vitor Baranauskas / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-28T13:22:34Z (GMT). No. of bitstreams: 1 Lopes_ManoelCesarValente_D.pdf: 24068595 bytes, checksum: 9f2c4cce65462510feafc4f1a1846207 (MD5) Previous issue date: 2000 / Doutorado
158

Contribuição ao estudo das propriedades dieletricas e mecanicas dos filmes finos de a-C:H, obtidos por PECVD

Balachova, Olga Viatcheslavovna 28 July 2018 (has links)
Orientador : Edmundo da Silva Braga / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-28T21:27:18Z (GMT). No. of bitstreams: 1 Balachova_OlgaViatcheslavovna_D.pdf: 632788 bytes, checksum: fda5f9a4786f67b7819c5577826064b8 (MD5) Previous issue date: 2001 / Doutorado
159

Modelo de linha de transmissão de circuito duplo trifasico utilizando parametros dependentes da frequencia

Prado, Afonso Jose do 03 August 2018 (has links)
Orientadores : Jose Pissolato Filho, Maria Cristina Dias Tavares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-03T03:51:05Z (GMT). No. of bitstreams: 1 Prado_AfonsoJosedo_D.pdf: 3301034 bytes, checksum: 6bebc98c6390b0b744ee507f1ec31840 (MD5) Previous issue date: 2002 / Doutorado
160

Planejamento de redes secundarias de distribuição de energia eletrica

Yoshimoto, Eduardo 03 August 2018 (has links)
Orientador: Christiano Lyra Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-03T21:35:03Z (GMT). No. of bitstreams: 1 Yoshimoto_Eduardo_M.pdf: 1325962 bytes, checksum: 7a3d6ef896a0e63627f46cd396e917bc (MD5) Previous issue date: 2003 / Resumo: Este trabalho apresenta uma nova metodologia para o Problema de Planejamento de Redes Secundárias de Distribuição de Energia Elétrica. A metodologia visa a minimização dos custos através de métodos heurísticos de otimização, tendo o compromisso de atendimento da demanda do consumidor final. A metodologia foi desenvolvida para um cenário onde se planeja a construção de um novo loteamento ("greenfield"). Divide-se a metodologia em três etapas, utilizando-se técnicas formais de otimização baseadas em heurísticas construtivas e de melhoria. Inicialmente, localiza-se os transformadores, utilizando-se o método das p-medíanas. Em seguida, através do algoritmo de obtenção de caminhos mínimos, é feita a ligação dos consumidores finais aos transformadores. Por fim, utilizando-se de um problema de Steiner, é feito o condutoramento da rede primária aos transformadores. Esta divisão é a fase construtiva do método GRASP. Na fase de melhoria é aplicada uma Busca em Vizinhança Variável (VNS). O trabalho propõe também uma nova metodologia para consideração adequada dos requisitos de potência e energia nas redes. Estudos de casos detalhados ilustram a aplicação das metodologias propostas. / Abstract: This work presents a new methodology for the planning problem of secundary networks in power distribution systems. The approach aims to minimize the compromise between facility costs and technical losses in secundary systems. The metodology was mainly developed for greenfild problems, where a new network must be built completely. It comprises three main phases, based on formal optimization techniques and heuristics. The first phase deals with transformers alocation, using a p-median optimization model. The second phase solves the secondary network routing problem. Finally, a Steiner tree problem defines the connections of transformers with the existing primary network. The three phases comprise the constructive part of a Greedy Randomized Adaptive Search Procedures (GRASP). Following, a Variable Neighborhood Search (VNS) process is applied to improve the solution. The work also presents a new approach to deal with loads, separeting power and energy demands. Case studies illustrate the possibilities of the approach. / Mestrado

Page generated in 0.0373 seconds