Spelling suggestions: "subject:"electrical power plants""
141 |
Probabilistic low voltage distribution network design for aggregated light industrial loadsVan Rhyn, Pierre 25 February 2015 (has links)
D.Ing. / This thesis initially reviews current empirical and probabilistic electrical load models available to distribution design engineers today to calculate voltage regulation levels in low voltage residential, commercial and light industrial consumer networks. Although both empirical and probabilistic techniques have extensively been used for residential consumers in recent years, it has been concluded that commercial and light industrial consumer loads have not been a focus area of probabilistic load study for purposes of low voltage feeder design. However, traditional empirical techniques, which include adjustments for diversity to accommodate non-coincidental electrical loading conditions, have generally been found to be applied using in-house design directives with only a few international publications attempting to address the problem. This work defines the light industrial group of consumers in accordance with its international Standard Industrial Classification (SIC) and presents case studies on a small group of three different types of light industrial sub-classes, It is proposed and proved that the electrical load models can satisfactorily be described as beta-distributed load current models at the instant of group or individual maximum power demand on typical characteristic 24-hour load cycles. Characteristic mean load profiles were obtained by recording repetitive daily loading of different sub-classes, ensuring adequate sample size at all times. Probabilistic modelling of light industrial loads using beta-distributed load current at maximum demand is a new innovation in the modelling of light industrial loads. This work is further -complemented by the development of a new probabilistic summation algorithm in spreadsheet format. This algorithm adds any selected number of characteristic load current profiles, adjusted for scale, power factor, and load current imbalance, and identifies the combined instant of group or system maximum demand. This spreadsheet also calculates the characteristic beta pdf parameters per phase describing the spread and profile of the combined system loading at maximum demand. These parameters are then conveniently used as input values to existing probabilistic voltage regulation algorithms to calculate voltage regulation in single-, bi- and three-phase low voltage distribution networks.
|
142 |
The power generation sector's demand for fossil fuels : a quantitative assessment on the viability of carbon fees for the reduction of greenhouse gas emissionsSeres, Stephen. January 2001 (has links)
No description available.
|
143 |
The fish populations of the Lower Forth Estuary, including the environmental impact of cooling water extractionGreenwood, M. F. D. January 2001 (has links)
The present study investigated the fish populations of the lower Forth Estuary, east Scotland. Cooling water extraction by the 2400 MW Longannet Power Station (LPS) inevitably removes a certain quantity of fish from the estuary, all of which experience mortality. The present study employed a sampling regime of greater intensity than previous studies to investigate the extent of mortalities from January 1999 - December 2000. Collections of fish impinged on intake screens were made eight times monthly, at LW or HW of spring or neap tides during the day or by night. Marine species dominated the assemblage of fish collected, with sprat, herring, and whiting contributing > 80% of total abundance. Sprat was twice as abundant as herring in 1999, while the proportions were very similar in 2000. Total abundance of all species collected in 1999 was estimated at 1. 09 x 107, while the value of 3.29 x 107 in 2000 was three times larger. These figures were the largest recorded among British estuarine and marine power stations, but were precisely the correct order based on an exponential relationship between total impingement and water abstraction rate established from data from other locations. Validation of the estimated total biomass of fish removed was given by comparison with the known total mass of all materials disposed to landfill. Statistical analysis of impingement data showed that tidal range and season were the most important environmental variables influencing the rate of removal of fish from the estuary. That light was not significant for most species is attributed to high levels of turbidity and the resulting low visibility by day and night. Demersal and benthic fish abundances collected from 1982 - 2000 in 30 annual trawls at three sites in the mid-lower Forth Estuary were analysed. Species tended to be present in greatest abundance at the most seaward of the sites. Patterns of seasonal abundance reflected those observed in the impingement study at LPS, and catches tended to be greatest at L W. Total species richness showed no significant trend over time, whilst total annual abundance of fish captured in trawls showed a significant negative trend. This was largely due to significant declines in the two most abundant species, namely whiting and eel pout, attributable in the latter case to increasing temperatures. Changes in the ichthyofaunal composition were largely driven by whiting, eel pout, cod and plaice. Eight of ten common species showed no significant trend in abundance over the length of the time series, suggesting them to perhaps be at equilibrium densities. Quantities of commercially fished species above minimum landing size limits that were removed by LPS were very low, and restricted to herring and occasional whiting. The quantity of juveniles that could have recruited into the fished populations was expressed as equivalent adults. The values were larger than any previously reported in the UK, primarily due to the quantities of juvenile fish impinged being greater than at any other British power station, and the importance of the Forth as a nursery area for marine species. It was concluded that LPS is the dominant UK power station in terms of magnitude of impingement losses. It may be prudent to consider a precautionary approach to mitigate losses, and to this end options for reduction of the magnitude of impingement are discussed.
|
144 |
Performance optimization of engineering systems with particular reference to dry-cooled power plantsConradie, Antonie Eduard 03 1900 (has links)
Thesis (PhD (Mechanical and Mechatronic Engineering))--University of Stellenbosch, 1995. / Computer simulation programs were developed for the analysis of dry-cooling systems for power
plant applications. Both forced draft direct condensing air"cooled condensers and hyperbolic natural
draft indirect dry-cooling towers are considered.
The results of a considerable amount of theoretical and experimental work are taken into account to
model all the physical phenomena ofthese systems, to formu1ate the problems in formal mathematical
terms and to design and apply suitable computational algorithms to solve these problems effectively
and reliably.
The dry-cooling systems are characterized by equation-based models. These equations are
simultaneously solved by a specially designed constrained nonlinear least squares algorithm to
determine the performance characteristics of the dry-cooling systems under fixed prescnoed
operating conditions, or under varying operating conditions when coupled to a turbo-generator set.
The solution procedure is very fast and effective.
A capital and operating cost estimation procedure, based on information obtained from dry-cooling
system component manufacturers and the literature, is proposed. Analytical functions express the
annual cost in terms ofthe various geometrical and operating parameters ofthe dry-cooling systems.
The simu1ation and the cost estimation procedures were coupled to a constrained nonlinear
programming code which enable the design of minimum cost dry-cooling systems at fixed prescribed
operating conditions, or dry-cooling systems which minimize the ratio of total annual cost to the
annual net power output of the corresponding turbo-generator set. Since prevailing atmospheric
conditions, especially the ambient temperature, influence the performance of dry-cooling systems,
wide fluctuations in turbine back pressure occur. Therefore, in the latter case the optimal design is
based on the annual mean hourly frequency ofambient temperatures, rather than a fixed value.
The equation-based models and the optimization problems are simultaneously solved along an
infeasible path (infeasible path integrated approach). The optimization model takes into
consideration all the parameters that may affect the capital and operating cost of the dry-cooling
systems and does not prescribe any limits, other than those absolutely essential due to practical
limitations and to simulate the systems effectively. The influence that changes ofthe constraint limits
and some problem parameters have on the optinmm solution, are evaluated (sensitivity analysis). The Sequential Quadratic Programming (SQP) method is used as the basis in implementing nonlinear
optimization techniques to solve the cost minimirnti~n problems. A stable dual active set algorithm
for convex quadratic programming (QP) problems is implemented that makes use of the special
features ofthe QP subproblems associated with the SQP methods. TIrls QP algorithm is also used as
part of the algorithm that solves the constrained nonlinear least squares problem This particular
implementation of the SQP method proved to be very reliable and efficient when applied to the
optimization problems based on the infeasible path integrated approach.
However, as the nonlinear optimization problems become large, storage requirements for the Hessian
matrix and computational expense of solving large quadratic programming (QP) subproblems
become prohibitive. To overcome these difficulties, a reduced Hessian SQP decomposition strategy
with coordinate bases was implemented. This method exploits the low dimensionality of the
subspace of independent decision variables. The performance of this SQP decomposition is further
improved by exploiting the mathematical structure of the engineering model, for example the block
diagonal structure ofthe Jacobian matrix. Reductions ofbetween 50-90% in the total CPU time are
obtained compared to conventional SQP optimization methods. However, more function and
gradient evaluations are used by this decomposition strategy.
The computer programs were extensively tested on various optimization problems and provide fast
and effective means to determine practical trends in the manufacturing and construction of costoptimal
dry-cooling systems, as well as their optimal performance and operating conditions in power
plant applications.
The dissertation shows that, through the proper application of powerful optimization strategies and
careful tailoring of the well constructed optimization model, direct optimization of complex models
does not need to be time consuming and difficult.
Reconnnendations for further research are made. / Imported from http://etd.sun.ac.za April 2010.
|
145 |
Clean technology advancement in the power industryYeung, Hon-chung., 楊漢忠. January 1997 (has links)
published_or_final_version / Environmental Management / Master / Master of Science in Environmental Management
|
146 |
Area COI-based slow frequency dynamics modeling, analysis and emergency control for interconnected power systemsDu, Zhaobin, 杜兆斌 January 2008 (has links)
published_or_final_version / Electrical and Electronic Engineering / Doctoral / Doctor of Philosophy
|
147 |
Critical path method as a project modelling technique in coal refurbishment projects29 June 2015 (has links)
M.Ing. (Engineering Management) / South African power demand has been increasing over the past years due to increase in energy consumption from industrial, commercial and residential sectors. In order to meet the growing power demand Eskom Holdings Limited SOC (Eskom) has implemented a number of initiatives such as the energy efficiency programme, power generating capacity increase and refurbishment of the operational coal fired power stations. Energy efficiency initiatives have been designed to encourage residential, commercial and industrial customers to use energy efficient technologies which consume less energy compare to conventional technologies. Power generating capacity increase programme includes construction of new base and peaking generating power plants (such as Medupi, Kusile and Ingula) and return to service of the old generating plants (such as Camden, Komati and Grootvlei). The refurbishment programme or coal refurbishment involves upgrading of operational coal fired power stations with the objective of extending their life expectancy, improve performance and to ensure compliance to latest safety standards...
|
148 |
Advanced modelling of porous screens in aerodynamic diffusers using variable resistance factorsJanse van Rensburg, Jacobus Johannes 12 1900 (has links)
Thesis (M. Tech. Mechanical engineering -- Vaal University of Technology / Strict emission legislation has forced industry in general to seriously consider the
negative impact it has on the environment, specifically concerning emissions from
burning fossil fuel into the atmosphere. In cases where emission levels exceed the
allowable limit, companies are forced to operate at lower operating conditions and
these load losses can result in a significant loss of revenue. This has forced
companies to improve their ash filtering capabilities by optimising electrostatic
precipitation systems.
One of the main factors impacting on the efficiency of such a system is the distribution
of the flow across the collection plates. The design of the inlet diffuser plays a major
role in the ultimate distribution of the flow through the precipitator. Porous screens are
positioned in the diffuser in order to distribute the flow across the total flow area with
the aim to achieve a uniform distribution of the flow.
CFD is widely used in industry to simulate the flow through precipitators in order to
optimise the flow distribution and thus increase the efficiency of the system. It was
found however that the current methods used to simulate these screens in CFD models
were not well researched and employed fixed resistance values that could not reliably
compensate for changes in the resistance coefficient due to a change in the angle of
incidence.
This study investigates advanced numerical methods for the simulation of porous
screens in applications where the angle of incidence changes continuously across the
face of the screen. New methods are introduced where the resistance of the screen is
calculated as a function of the changing angle of incidence. The methods currently
used are also investigated and compared with results from the new methods.
Extensive experimental work was required to supply empirical data for the validation of
the numerical methods that are proposed. For this reason, the first part of this study
focused on the design construction and commissioning of a low speed wind tunnel.
Results are presented and discussed for flow profiles through wide-angle diffusers at
different angles and also for a number of different screens positioned in the centre of
the diffuser.
This study also investigates the sensitivity of a CFD simulation code to factors such as
numerical discretisation schemes, turbulence models and solution relaxation
specifically for wide-angle diffusers. These factors were tested for diffusers at different
angles and included tests on open diffusers and also with screens positioned inside the
diffuser.
It was concluded that the current methods used are not adequate to capture the true
flow profiles for a range of different screen geometries. Although the proposed models
did improve on the limitations of the current methods, it was found that the applicability
of these models is still limited and that further research would be required to develop
numerical methods that are valid for a wide range of applications. / Vaal University of Technology, The National Research Foundation (NRF) and Eskom TSI
|
149 |
Study of New England utilities' particulate air pollution control facilities to determine relative viability of approaches to upgrade and retrofitMelcher, James R., Zieve, Peter Brian 11 1900 (has links)
Sponsored by Boston Edison Company, New England Power Service Company, Northeast Utilities Service Company under M.I.T. Energy Laboratory Electric Utility Program.
|
150 |
The fluxes and fates of arsenic, selenium, and antimony from coal fired power plants to riversLesley, Michael Patrick 01 December 2003 (has links)
No description available.
|
Page generated in 0.0875 seconds