21 |
Návrh rekonstrukce distribuční sítě 0,4 kV E.ON v zadané oblasti / Proposal of the reconstruction of 0,4 kV distribution network in a specific areaFojtík, Martin January 2012 (has links)
This Master’s thesis deals with the problem of distribution electrical network with a focus on solving the steady operation of the electrical distribution network for E.ON Brno - Lisen. The calculation is made by using BIZON PAS Off-Line. The first part of thesis is specialized on the distribution of individual LV and MV networks.The second part of thesis is specialized on the general calculation of the steady operation distribution network and describe criteria for the design and evaluation of this network. In the practical part is calculate existing network in selected area in which is located 53 distribution transformers. In the final part is evaluate the status of existing network and perform design optimization and assessment of this network.
|
22 |
Modélisation et étude mathématique de réseaux de câbles électriques / Mathematical modeling of electrical networksBeck, Geoffrey 31 March 2016 (has links)
Cette thèse porte sur la modélisation d'un réseau de câbles coaxiaux et multi-conducteurs. Ce dernier peut être mathématiquement traduit par les équations aux dérivées partielles de Maxwell qui régissent la propagation des ondes électromagnétiques en son sein ou par un modèle type circuit électrique d'inconnues - les potentiels et courants électriques- qui vérifient sur les branches du circuit l'équation des télégraphistes et sur les noeuds les lois de Kirchhoff.Si la première méthode est assez générale pour comprendre toutes sortes de défauts, elle néanmoins trop couteuse pour les applications que nous avons en tête, à savoir le contrôle non destructif. La seconde quant à elle est obtenue par une modélisation non issue de la théorie de Maxwell et est valide que si les câbles sont parfaits (cylindriques, sans pertes...). Nous avons établi diverses modèles 1D venant généraliser l'équation des télégraphistes et les lois de Kirchhoff pour y incorporer diverses défauts (géométrie, pertes, effet de peau, caractéristique des matériaux variables) tant sur les câbles que dans les jonctions. Ceux-ci sont obtenus via des analyses asymptotiques (classiques, multi-échelles, raccordées) des équations 3D de Maxwell en considérant certains paramètres (dimensions transverses des câbles par rapport à leurs longueurs, conductivité du milieu diélectrique par rapport à celle du métal des âmes, petite taille de la zone de jonction par rapport à l'ensemble du réseau) extrêmement petits.Une des difficultés mathématiques tient en ce que les domaines que nous prendrons en compte (sections des câbles, jonctions) ne sont aucunement simplement connexes, nous obligeant ainsi à remanier quelques outils standard tel les décompositions en potentiels. / This thesis aim to modelize network made of coaxial and multi-conductors cables.It could be mathematically represent with the Maxwell equations which deals on electromagnetic waves propagating in the network or an electrical circuit whose unknowns - the electrical potentials and currents - satisfy the telegrapher's equation on each branches and the Kirchhoff's laws on each knots.The first method is enough general to integrate many defaults but numerically too expansive for the application we have in mind, namely non destructive testing. The second one is not obtained from the Maxwell theory and it is valid if and only if the cable are perfect (cylindrical, lossless...). We derive some 1D models generalizing the usual telegrapher's equation and Kirchhoff's rules from Maxwell's equation. This new models integrate plenty of defects (geometry, losses, skin-effect, materials' characteristics varying) and are derive via asymptotic analysis (classical ones, multi-scales ones, matched ones) by considering very small parameters (transverse dimensions of the cables relative to length of the cables, conductivity of the dielectric part relative to the metal of the inner-wires, size of the junction part relative to the whole network).One of the mathematical difficult is due to the fact that the geometry we will consider (sections of the cables, junctions) are not simply connected. Thus we will generalize usual tools such as the Helmholtz decompositions.
|
23 |
Análise do amortecimento de modos interáreas com o método de imposição de polos. / Analysis damping of modes inter-area with the method of imposition of poles.Febres Tapia, Carlos Alberto 18 July 2013 (has links)
Este trabalho aborda as oscilações eletromecânicas de baixa frequência, relativas a modos interáreas, pouco amortecidos, avaliando o seu impacto no desempenho de redes elétricas multi-máquinas com o objetivo de elevar o amortecimento destes modos com equipamentos TCSC. Os locais apropriados para instalação destes equipamentos são escolhidos com a análise dos resíduos de funções de transferência e o ajuste de parâmetros, para o projeto coordenado de controladores, utiliza o método de imposição de polos. O sistema não linear de equações, obtido com a aplicação do método de imposição de polos, supondo coeficientes de amortecimento pré-estabelecidos, é resolvido utilizando-se o método de Newton Raphson. Adicionalmente, avalia-se a possibilidade do método auxiliar na análise de interações entre controladores e identificação de acoplamentos, por meio da análise dos termos que compõem as equações de imposição de polos. / This work deals with low frequency oscillations related to inter-area modes, evaluating their impact on the performance of multi-machine electrical networks with the aim to increase the damping of these modes using TCSC. The best places to install these devices are chosen with the analysis of the residues of transfer functions and the parameter fitting for coordinated application of stabilizers is performed with the pole placement method. The nonlinear system of equations, obtained with the pole placement method, assuming specified damping factors, is solved with the Newton-Raphson method. The method is also used in the analysis of control interaction among stabilizers through the evaluation of individual parcels of the pole placement equations, as an additional feature of the approach.
|
24 |
Análise do amortecimento de modos interáreas com o método de imposição de polos. / Analysis damping of modes inter-area with the method of imposition of poles.Carlos Alberto Febres Tapia 18 July 2013 (has links)
Este trabalho aborda as oscilações eletromecânicas de baixa frequência, relativas a modos interáreas, pouco amortecidos, avaliando o seu impacto no desempenho de redes elétricas multi-máquinas com o objetivo de elevar o amortecimento destes modos com equipamentos TCSC. Os locais apropriados para instalação destes equipamentos são escolhidos com a análise dos resíduos de funções de transferência e o ajuste de parâmetros, para o projeto coordenado de controladores, utiliza o método de imposição de polos. O sistema não linear de equações, obtido com a aplicação do método de imposição de polos, supondo coeficientes de amortecimento pré-estabelecidos, é resolvido utilizando-se o método de Newton Raphson. Adicionalmente, avalia-se a possibilidade do método auxiliar na análise de interações entre controladores e identificação de acoplamentos, por meio da análise dos termos que compõem as equações de imposição de polos. / This work deals with low frequency oscillations related to inter-area modes, evaluating their impact on the performance of multi-machine electrical networks with the aim to increase the damping of these modes using TCSC. The best places to install these devices are chosen with the analysis of the residues of transfer functions and the parameter fitting for coordinated application of stabilizers is performed with the pole placement method. The nonlinear system of equations, obtained with the pole placement method, assuming specified damping factors, is solved with the Newton-Raphson method. The method is also used in the analysis of control interaction among stabilizers through the evaluation of individual parcels of the pole placement equations, as an additional feature of the approach.
|
25 |
Algoritmo auto-adaptativo para proteção de sobrecorrente instantânea.SOUZA JÚNIOR, Francisco das Chagas. 13 August 2018 (has links)
Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-08-13T16:41:07Z
No. of bitstreams: 1
FRANCISCO DAS CHAGAS SOUZA JÚNIOR – TESE (PPGEEI) 2016.pdf: 4537364 bytes, checksum: 1696c9bd2456c0caad5ee6e61bcb7ca4 (MD5) / Made available in DSpace on 2018-08-13T16:41:07Z (GMT). No. of bitstreams: 1
FRANCISCO DAS CHAGAS SOUZA JÚNIOR – TESE (PPGEEI) 2016.pdf: 4537364 bytes, checksum: 1696c9bd2456c0caad5ee6e61bcb7ca4 (MD5)
Previous issue date: 2016-07-05 / Uma técnica auto-adaptativa que torna a obtenção dos ajustes de coordenação de relés de sobre corrente instantânea para sistemas de distribuição uma tarefa automática, sem a necessidade de intervenção humana e nem a interrupção do fornecimento de energia elétrica ou do monitoramento da rede é proposta. Usando uma arquitetura distribuída, formada por três camadas conectadas através de canal de comunicação, modificações topológicas como entrada/saída de linhas, e/ou nos perfis de carga e geração do sistema elétrico terão seus efeitos automaticamente refletidas nos ajustes dos dispositivos de proteção. O método proposto usa a corrente de carga
como item principal para a determinação dos ajustes das unidades instantâneas de sobre corrente em redes de distribuição de média tensão com e sem apresentação geração distribuída.
Por meio do cálculo online dos equivalentes de rede a técnica proposta necessita de baixos níveis de intervenção humana para a realização dos estudos de coordenação e seletividade. Os resultados obtidos comprovam a viabilidade técnica da metodologia proposta e corrobora com o estado da arte no tocante ao desenvolvimento das redes elétricas inteligentes. / A self-adaptive technique that improves the instantaneous overcurrent relay settings determination an automatic task, without human intervention neither interruption on electric supply or grid monitoring is proposed. An architecture designed by three layers connected using a communication channel provides that modificationon power electric grid as connection/disconnection of transmissionlines, and/or on generator or load profiles will be automatically reflected on protective device settings. Load current has been used to determine the reach of instantaneous over current relay settings in a médium voltage distribution system considering cases with and without distributed generation connected on the grid. The possibility of online determination at Thevenin equivalent circuit low human interventions to execute coordination study. Obtained results demonstrate the viability of proposed technique an dincrease with state of art a bout improvements of smart electric grids.
|
26 |
Caracterizacão de redes de energia elétrica como meio de transmissão de dadosOliveira, Thiago Rodrigues 28 September 2010 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-20T12:09:28Z
No. of bitstreams: 1
thiagorodriguesoliveira.pdf: 2429204 bytes, checksum: b1904f2bde31b546890c5bfa77d58c80 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-20T12:44:42Z (GMT) No. of bitstreams: 1
thiagorodriguesoliveira.pdf: 2429204 bytes, checksum: b1904f2bde31b546890c5bfa77d58c80 (MD5) / Made available in DSpace on 2017-04-20T12:44:42Z (GMT). No. of bitstreams: 1
thiagorodriguesoliveira.pdf: 2429204 bytes, checksum: b1904f2bde31b546890c5bfa77d58c80 (MD5)
Previous issue date: 2010-09-28 / Esta dissertação apresenta, de forma detalhada, um conjunto de metodologias e técnicas destinadas à análise de redes de energia elétrica como meio de transmissão de dados (power line communication - PLC). As características das redes elétricas que influenciam um sistema de comunicação de dados consideradas neste trabalho são as seguintes: a impedância de acesso à rede elétrica, a resposta ao impulso e o ruído. Para tanto, técnicas de processamento de sinais para estimação da resposta em frequência, estimação do comprimento efetivo da resposta ao impulso, detecção e segmentação de ruídos impulsivos e análise espectral de ruídos aditivos são propostas e discutidas na presente contribuição. Os desempenhos objetivos e a apreciação subjetiva das técnicas propostas, a partir de dados sintéticos e medidos, evidenciam a adequação destas técnicas para a análise em questão. Além disso, formulações matemáticas para a resposta ao impulso de canais PLC invariantes, variantes e periodicamente variantes no tempo, derivadas a partir do modelo de multi-propagação para canais PLC, são apresentadas. Tais formulações proporcionam de forma simples e objetiva a emulação dos possíveis comportamentos temporais de canais PLC reais e, portanto, podem se constituir como ferramentas de grande utilidade para o projeto e a avaliação de sistemas de comunicações baseados na tecnologia PLC. / This thesis addresses a set of methodologies and techniques for the analysis of electric grids as a medium for data communications (power line communications - PLC). The main features influencing a communication system that are considered in this work are the input impedance, the channel impulse response, and the noise. In this regards, signal processing-based techniques are investigated, proposed and analyzed for the estimations of the channel frequency response and the effective length of the channel impulse response; the detection and segmentation of impulsive noise; and the power spectral analysis of the additive noise at the channel output. The numerical performance and subjective analysis regarding the use of the proposed techniques in synthetic and measured data indicate that those techniques fit well in the thesis purposes. In addition, mathematical formulation for invariant, time-varying, and periodically time-varying PLC channel models, which are based on multi-path channel model approach, are presented. These formulations are simple and elegant ones for the emulation of possible temporal behavior of existing PLC channels and, as a result, can constitute a useful tool for the design and analysis of PLC systems.
|
27 |
Fluxo de carga trifásico para análise de distorções harmônicas em redes de distribuição de energia elétrica / Three-phase power flow for harmonic distortion analysis in power distribution networksDuque, Marina Borges 22 August 2018 (has links)
Orientador: Carlos Alberto Favarin Murari / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-22T04:03:37Z (GMT). No. of bitstreams: 1
Duque_MarinaBorges_M.pdf: 1960535 bytes, checksum: 1d0e3bb5b148b1377f1e8e33d3ab25ac (MD5)
Previous issue date: 2013 / Resumo: Para garantir o bom desempenho das redes de distribuição de energia elétrica, bem como aumentar a qualidade dos serviços prestados aos consumidores, faz-se necessário o desenvolvimento e a implementação de metodologias que permitam avaliar tanto os custos como os benefícios que trazem as diferentes alternativas de projeto propostas e os seus impactos no sistema como um todo, mantendo sempre aceitáveis os índices de qualidade e confiabilidade do fornecimento aos diferentes consumidores: residencial, comercial e industrial. Nesse contexto, um programa computacional que realize o cálculo dos fluxos de potência é uma ferramenta imprescindível na análise dos sistemas elétricos de potência tendo-se como principais grandezas de interesse, as tensões nas diferentes barras e os fluxos de potência ativa e reativa em todos os componentes da rede elétrica (linhas, transformadores, etc.). E como a maior parte das redes de distribuição de energia elétrica é trifásica, é de fundamental importância adotar uma formulação trifásica que represente de forma adequada os desequilíbrios, e, portanto nesta dissertação é apresentada uma versão de fluxo de carga trifásico baseada no Método Iterativo de Correção de Tensão com possibilidade de inserção de cargas não lineares para contemplar as frequências harmônicas e assim obter o estado da rede (magnitude e ângulo das tensões nodais) e também de outras grandezas elétricas contemplando os efeitos causados por cargas não lineares, com ênfase para o motor de indução trifásico / Abstract: To ensure a good performance of power distribution networks as well as to increase the quality of services provided for the consumers, it is necessary the development and implementation of methodologies to assess the costs and the benefits of the different operating alternatives and their impacts on the system as a whole, while maintaining acceptable levels of quality and the reliability of electricity supply to the various consumers: residential, commercial and industrial. In this context, a computer program that performs the calculation of power flows is an essential tool in the analysis of electrical power systems having as main quantities of interest - nodal voltages and active and reactive power flows - at all electrical network components (lines, transformers, etc.). Once the electrical distribution networks are three-phase, it is crucial to adopt a three-phase formulation that adequately represents the load unbalance. We propose a version of a three-phase load flow based on the Voltage Correction Iterative Method with the possibility of including non-linear loads - with emphasis for three-phase induction motor - to simulating harmonic frequencies and getting the corresponding node voltages and other electrical quantities / Mestrado / Energia Eletrica / Mestra em Engenharia Elétrica
|
28 |
Návrh úprav a konfigurace sítě 22 kV po instalaci transformace 110/22 kV ve spínací stanici Brno-sever / Proposal of design and configuration of 22 kV network after installation of 110/22 kV transformation in Brno-Sever switching substationMišinger, Ondřej January 2013 (has links)
The theoretical part of this thesis deals with distribution networks in terms of distribution according to different criteria, describes the main elements of electric distribution networks and their qualities. The following describes the methods of calculating the steady state of electrical networks. These methods are nowadays used as basics for computer programs. In the penultimate chapter of the theoretical part are summarized the principles for the development of present networks and construction of new electrical networks. The aim of practical part of the thesis is to assess the current condition of the network 22 kV in the city of Brno and assess the condition after installation of 110/22 kV transformation in Brno-Sever switching substation. After evaluating the results of steady state electrical network and identifying certain problems is the following aim a proposal of solving problems that emerged in the network. The result should be operational, functional and reliable electric distribution network. This thesis used to calculate the steady state electrical networks by software PAS DAISY Off-Line Bizon V4.
|
Page generated in 0.0894 seconds