• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 13
  • 10
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Tratamento eletroquímico e eletroquímico foto-assistido na degradação de efluentes da indústria têxtil / Electrochemical and photo-assisted electrochemical degradation of textile wastewater

Alves, Patricia Aparecida 13 September 2010 (has links)
Este trabalho apresenta o estudo da degradação eletroquímica e eletroquímica foto-assistida de efluentes têxteis industriais usando ânodos dimensionalmente estáveis (ADE). As amostras analisadas foram coletadas diretamente do tanque de equalização (efluente bruto) e do tanque final (efluente biologicamente tratado) cedidas pela empresa Toalhas São Carlos, de São Carlos, São Paulo. As degradações foram realizadas em uma célula de fluxo do tipo filtro prensa com eletrodo ADE comercial (composição nominal Ti/Ti0,7Ru0,3O2) sob recirculação constante. A fim de avaliar os melhores parâmetros de degradação, foram estudadas as influências do tipo de eletrólito suporte (NaCl e Na2SO4), concentrações de NaCl (0,05 a 0,30 mol L-1), densidade de corrente (10 a 120 mA cm-2) e pH (4, 7, 8, 9 e 12). Após definição dos melhores parâmetros, novas amostras do tanque de equalização foram coletadas, em dias alternados para avaliar a influência da composição do efluente. Ensaios eletroquímicos foto-assistidos foram realizados nas mesmas condições que os ensaios eletroquímicos visando a comparação dos métodos. Caracterizações do ADE foram realizadas por voltametria cíclica na ausência e presença de efluente e de luz. Durante as eletrólises de 2 horas, amostras foram coletadas e analisadas por espectroscopia UV vis, carbono orgânico total (COT) e demanda química de oxigênio (DQO). Análises da formação de subprodutos foram realizadas pelos métodos de fitotoxicidade e organoclorados que mostraram uma maior toxicidade após 10 horas de eletrolise. Avaliação do residual de cloro e cloreto complementaram os estudos. Observou-se que a degradação é mais efetiva pelo método eletroquímico foto-assistido em relação ao método eletroquímico. Também, a adição de NaCl favorece a degradação pela formação de agentes oxidantes, ao contrário do Na2SO4. Nas maiores concentrações de NaCl e densidades de corrente implicam em maior remoção de cor e DQO. Contudo no estudo com diferentes valores de pH, os melhores resultados foram em pH mais baixo. Considerando todos os resultados, os melhores parâmetros para degradação de efluentes têxteis industriais foram densidade de corrente de 40 mA cm-2, pH 8, 0,15 mol L-1 de NaCl utilizado como eletrólito suporte e degradação com o método eletroquímico foto-assistido em efluente do tanque de equalização (efluente sem tratamento biológico). / This study presents the electrochemical and photo-assisted electrochemical degradation of real textile industrial effluent at Dimensionally Stable Anodes (DSA). The effluent samples were collected directly from the mixing tank and from the final effluent discharge after biological treatment. The effluent samples were provided by the company Toalhas São Carlos situated in the city of São Carlos, São Paulo state. The degradation assays were performed in a filter-press cell with a commercial DSA electrode (nominal composition Ti/Ti0,7Ru0,3O2) under constant recirculation. In order to assess the best degradation parameters the influences of the type of electrolyte (NaCl and Na2SO4) was studied. NaCl concentrations (0.05 to 0.30 mol L-1), current density (10 a 120 mA cm-2) and pH (4, 7, 8, 9 and 12) were investigated. After defining the best parameters, new effluent samples were collected on alternate days to assess the influence of the effluent composition. Photo-assisted electrochemical tests were performed under the same conditions as the electrochemical tests in order to compare the two methods. Characterizations of the DSA materials were performed by cyclic voltammetry in the absence and presence of wastewater and light. During the 2 h electrolyses, samples were collected and analyzed by UV-vis spectroscopy, total organic carbon (TOC), chemical oxygen demand (COD) and conductivity. Analyses of the formation of degradation products were performed by phytotoxicity tests and AOX analysis. Greater toxicity was observed after 10 hours of electrolysis. Evaluation of residual chlorine and chloride complemented the studies. It was observed that degradation is more effective for the photo-assisted electrochemical method than electrochemical method. Also the addition of NaCl promotes degradation by in-situ generated oxidizing agents. Higher concentrations of NaCl and current densities increased color removal and COD. However in tests with different pH values, the best results were observed at lower pH. Considering all the results, the best parameters for degradation of real textile effluent were current density at 40 mA cm-2, pH 8 and 0.15 mol L-1 NaCl used as supporting electrolyte and degradation using the photo-assisted electrochemical method.
2

Comparação entre diferentes processos de degradação do antibiótico sulfametoxazol / Comparison between different processes for degradation of antibiotic sulfamethoxazole

Hussain, Sajjad 28 February 2014 (has links)
A ocorrência de produtos farmacêuticos e de cuidados pessoais no meio ambiente tem levado a preocupações sobre seu impacto ambiental e à saúde pública. O sulfametoxazol (SMX) é um fármaco que tem sido encontrado amplamente no ambiente. Neste estudo foi verificada a eficácia de vários processos, a saber eletroquímico, eletroquímico foto assistido, fotoquímico, Fenton e foto-Fenton, para a degradação de SMX em solução aquosa. A degradação eletroquímica e eletroquímica foto assistida foram realizadas em uma célula de fluxo do tipo filtro-prensa, usando um ânodo dimensionalmente estável comercial com composição nominal Ti/Ru0,3Ti0,7O2. Durante ambos os processos, efeitos de diferentes parâmetros foram analisados, como a natureza do eletrólito, a concentração de eletrólito suporte (NaCl) e a densidade de corrente aplicada. Os experimentos fotoquímicos, Fenton e foto-Fenton foram realizados em um reator de vidro cilíndrico de compartimento único. O efeito das concentrações inicias de Fe2+ e de H2O2 foram estudados para os processos Fenton e foto-Fenton. Similarmente, o efeito do pH inicial, a concentração inicial do SMX e a temperatura foram investigados para todos os processos. A variação da concentração de SMX foi determinada por cromatografia líquida de alta eficiência (CLAE) e a quantidade de matéria orgânica foi monitorada por análise de carbono orgânico total (COT). Os resultados obtidos indicaram que o SMX foi completamente degradado, porém, o COT foi apenas parcialmente removido em todos os processos. No período de tempo de ensaio estabelecido o aumento da densidade de corrente e da concentração de NaCl mais eficiente para a degradação e remoção de COT nos processos eletroquímicos. A quantidade de Fe2+ e H2O2 aumenta a eficiência do processo Fenton e foto-Fenton, e meio ácido foi favorável para todos os processos. O consumo de energia elétrica, baseado no parâmetro EEO (energia por ordem) mostrou que os processos eletroquímicos são energeticamente mais eficientes do que os fotoquímicos. As degradações acompanhadas por CLAE acoplado à espectrometria de massas, permitiu que vários intermediários fossem identificados, sendo então proposta uma sequência reacional para a degradação do SMX. O radical hidroxila e o cloro ativo atacam os anéis benzílico e isoxazólico, tendo sido demonstrado que os compostos iniciais formados foram os compostos hidrolisados e clorados. Os íons inorgânicos, tais como: NO3-, NH4+ e SO42-, também foram identificados durante os processos de degradação. / The occurrence of pharmaceuticals and personal care products in the environment has raised concerns about their impact upon environmental and public health. Sulfamethoxazole (SMX) is a pharmaceutical that has been found widely in the environment. This study investigated the effectiveness of various processes such as electrochemical, photo assisted electrochemical, photochemical, Fenton photo-Fenton to SMX degradation in aqueous solution. The electrochemical and photo-assisted electrochemical degradations were performed in a filter press type flow cell using a dimensionally stable anode with nominal composition of Ti/Ru0.3Ti0.7O2. During both these processes the effects of different parameters were analyzed, such as, nature of the electrolyte concentration of the supporting electrolyte (NaCl) and the applied current density. The photochemical, Fenton and photo - Fenton experiments were carried out in a single compartment cylindrical glass reactor. The effects initial iron concentrations and H2O2 were studied for Fenton and photo-Fenton processes. Similarly the effect of initial pH, initial concentration of SMX and temperature were investigated for all processes. The variation of SMX concentration was determined by high performance liquid chromatography (HPLC) and the amount of organic matter was monitored by analysis of total organic carbon (TOC). The results indicated that SMX was completely degraded, but TOC was partially removed in all processes studied, during experimental period the increase of the current density and NaCl concentration enhanced the degradation and TOC removal in the electrochemical processes. The amount of iron and H2O2 increases the efficiency of Fenton and photo-Fenton processes and acidic media was favorable for all processes. The electrical energy consumption parameter based on EEO (energy per order) was also evaluated and it was observed that the electrochemical processes are more energetically efficient than the photochemical. The degradations followed by HPLC coupled with mass spectrometry, in which several intermediates were identified and proposed a reaction sequence for the degradation of SMX. The hydroxyl radical and active chlorine attack benzene and isoxazólico rings, and has been demonstrated that the initial compounds formed were hydrolyzed and chlorinated compounds. Inorganic ions such NO3-, NH4+ and SO42- were also identified during degradation processes.
3

Tratamento eletroquímico e eletroquímico foto-assistido na degradação de efluentes da indústria têxtil / Electrochemical and photo-assisted electrochemical degradation of textile wastewater

Patricia Aparecida Alves 13 September 2010 (has links)
Este trabalho apresenta o estudo da degradação eletroquímica e eletroquímica foto-assistida de efluentes têxteis industriais usando ânodos dimensionalmente estáveis (ADE). As amostras analisadas foram coletadas diretamente do tanque de equalização (efluente bruto) e do tanque final (efluente biologicamente tratado) cedidas pela empresa Toalhas São Carlos, de São Carlos, São Paulo. As degradações foram realizadas em uma célula de fluxo do tipo filtro prensa com eletrodo ADE comercial (composição nominal Ti/Ti0,7Ru0,3O2) sob recirculação constante. A fim de avaliar os melhores parâmetros de degradação, foram estudadas as influências do tipo de eletrólito suporte (NaCl e Na2SO4), concentrações de NaCl (0,05 a 0,30 mol L-1), densidade de corrente (10 a 120 mA cm-2) e pH (4, 7, 8, 9 e 12). Após definição dos melhores parâmetros, novas amostras do tanque de equalização foram coletadas, em dias alternados para avaliar a influência da composição do efluente. Ensaios eletroquímicos foto-assistidos foram realizados nas mesmas condições que os ensaios eletroquímicos visando a comparação dos métodos. Caracterizações do ADE foram realizadas por voltametria cíclica na ausência e presença de efluente e de luz. Durante as eletrólises de 2 horas, amostras foram coletadas e analisadas por espectroscopia UV vis, carbono orgânico total (COT) e demanda química de oxigênio (DQO). Análises da formação de subprodutos foram realizadas pelos métodos de fitotoxicidade e organoclorados que mostraram uma maior toxicidade após 10 horas de eletrolise. Avaliação do residual de cloro e cloreto complementaram os estudos. Observou-se que a degradação é mais efetiva pelo método eletroquímico foto-assistido em relação ao método eletroquímico. Também, a adição de NaCl favorece a degradação pela formação de agentes oxidantes, ao contrário do Na2SO4. Nas maiores concentrações de NaCl e densidades de corrente implicam em maior remoção de cor e DQO. Contudo no estudo com diferentes valores de pH, os melhores resultados foram em pH mais baixo. Considerando todos os resultados, os melhores parâmetros para degradação de efluentes têxteis industriais foram densidade de corrente de 40 mA cm-2, pH 8, 0,15 mol L-1 de NaCl utilizado como eletrólito suporte e degradação com o método eletroquímico foto-assistido em efluente do tanque de equalização (efluente sem tratamento biológico). / This study presents the electrochemical and photo-assisted electrochemical degradation of real textile industrial effluent at Dimensionally Stable Anodes (DSA). The effluent samples were collected directly from the mixing tank and from the final effluent discharge after biological treatment. The effluent samples were provided by the company Toalhas São Carlos situated in the city of São Carlos, São Paulo state. The degradation assays were performed in a filter-press cell with a commercial DSA electrode (nominal composition Ti/Ti0,7Ru0,3O2) under constant recirculation. In order to assess the best degradation parameters the influences of the type of electrolyte (NaCl and Na2SO4) was studied. NaCl concentrations (0.05 to 0.30 mol L-1), current density (10 a 120 mA cm-2) and pH (4, 7, 8, 9 and 12) were investigated. After defining the best parameters, new effluent samples were collected on alternate days to assess the influence of the effluent composition. Photo-assisted electrochemical tests were performed under the same conditions as the electrochemical tests in order to compare the two methods. Characterizations of the DSA materials were performed by cyclic voltammetry in the absence and presence of wastewater and light. During the 2 h electrolyses, samples were collected and analyzed by UV-vis spectroscopy, total organic carbon (TOC), chemical oxygen demand (COD) and conductivity. Analyses of the formation of degradation products were performed by phytotoxicity tests and AOX analysis. Greater toxicity was observed after 10 hours of electrolysis. Evaluation of residual chlorine and chloride complemented the studies. It was observed that degradation is more effective for the photo-assisted electrochemical method than electrochemical method. Also the addition of NaCl promotes degradation by in-situ generated oxidizing agents. Higher concentrations of NaCl and current densities increased color removal and COD. However in tests with different pH values, the best results were observed at lower pH. Considering all the results, the best parameters for degradation of real textile effluent were current density at 40 mA cm-2, pH 8 and 0.15 mol L-1 NaCl used as supporting electrolyte and degradation using the photo-assisted electrochemical method.
4

Comparação entre diferentes processos de degradação do antibiótico sulfametoxazol / Comparison between different processes for degradation of antibiotic sulfamethoxazole

Sajjad Hussain 28 February 2014 (has links)
A ocorrência de produtos farmacêuticos e de cuidados pessoais no meio ambiente tem levado a preocupações sobre seu impacto ambiental e à saúde pública. O sulfametoxazol (SMX) é um fármaco que tem sido encontrado amplamente no ambiente. Neste estudo foi verificada a eficácia de vários processos, a saber eletroquímico, eletroquímico foto assistido, fotoquímico, Fenton e foto-Fenton, para a degradação de SMX em solução aquosa. A degradação eletroquímica e eletroquímica foto assistida foram realizadas em uma célula de fluxo do tipo filtro-prensa, usando um ânodo dimensionalmente estável comercial com composição nominal Ti/Ru0,3Ti0,7O2. Durante ambos os processos, efeitos de diferentes parâmetros foram analisados, como a natureza do eletrólito, a concentração de eletrólito suporte (NaCl) e a densidade de corrente aplicada. Os experimentos fotoquímicos, Fenton e foto-Fenton foram realizados em um reator de vidro cilíndrico de compartimento único. O efeito das concentrações inicias de Fe2+ e de H2O2 foram estudados para os processos Fenton e foto-Fenton. Similarmente, o efeito do pH inicial, a concentração inicial do SMX e a temperatura foram investigados para todos os processos. A variação da concentração de SMX foi determinada por cromatografia líquida de alta eficiência (CLAE) e a quantidade de matéria orgânica foi monitorada por análise de carbono orgânico total (COT). Os resultados obtidos indicaram que o SMX foi completamente degradado, porém, o COT foi apenas parcialmente removido em todos os processos. No período de tempo de ensaio estabelecido o aumento da densidade de corrente e da concentração de NaCl mais eficiente para a degradação e remoção de COT nos processos eletroquímicos. A quantidade de Fe2+ e H2O2 aumenta a eficiência do processo Fenton e foto-Fenton, e meio ácido foi favorável para todos os processos. O consumo de energia elétrica, baseado no parâmetro EEO (energia por ordem) mostrou que os processos eletroquímicos são energeticamente mais eficientes do que os fotoquímicos. As degradações acompanhadas por CLAE acoplado à espectrometria de massas, permitiu que vários intermediários fossem identificados, sendo então proposta uma sequência reacional para a degradação do SMX. O radical hidroxila e o cloro ativo atacam os anéis benzílico e isoxazólico, tendo sido demonstrado que os compostos iniciais formados foram os compostos hidrolisados e clorados. Os íons inorgânicos, tais como: NO3-, NH4+ e SO42-, também foram identificados durante os processos de degradação. / The occurrence of pharmaceuticals and personal care products in the environment has raised concerns about their impact upon environmental and public health. Sulfamethoxazole (SMX) is a pharmaceutical that has been found widely in the environment. This study investigated the effectiveness of various processes such as electrochemical, photo assisted electrochemical, photochemical, Fenton photo-Fenton to SMX degradation in aqueous solution. The electrochemical and photo-assisted electrochemical degradations were performed in a filter press type flow cell using a dimensionally stable anode with nominal composition of Ti/Ru0.3Ti0.7O2. During both these processes the effects of different parameters were analyzed, such as, nature of the electrolyte concentration of the supporting electrolyte (NaCl) and the applied current density. The photochemical, Fenton and photo - Fenton experiments were carried out in a single compartment cylindrical glass reactor. The effects initial iron concentrations and H2O2 were studied for Fenton and photo-Fenton processes. Similarly the effect of initial pH, initial concentration of SMX and temperature were investigated for all processes. The variation of SMX concentration was determined by high performance liquid chromatography (HPLC) and the amount of organic matter was monitored by analysis of total organic carbon (TOC). The results indicated that SMX was completely degraded, but TOC was partially removed in all processes studied, during experimental period the increase of the current density and NaCl concentration enhanced the degradation and TOC removal in the electrochemical processes. The amount of iron and H2O2 increases the efficiency of Fenton and photo-Fenton processes and acidic media was favorable for all processes. The electrical energy consumption parameter based on EEO (energy per order) was also evaluated and it was observed that the electrochemical processes are more energetically efficient than the photochemical. The degradations followed by HPLC coupled with mass spectrometry, in which several intermediates were identified and proposed a reaction sequence for the degradation of SMX. The hydroxyl radical and active chlorine attack benzene and isoxazólico rings, and has been demonstrated that the initial compounds formed were hydrolyzed and chlorinated compounds. Inorganic ions such NO3-, NH4+ and SO42- were also identified during degradation processes.
5

Degradação do antibiótico tetraciclina por vários processos em mistura salina / Degradation of antibiotic tetracycline by various processes in saline medium

Gul, Saima 25 April 2014 (has links)
A degradação de antibiótico tetraciclina (TeC) foi avaliada por vários processos a saber, eletroquímico, eletroquímico foto-assistido, Fenton e foto-Fenton. Uma vez que este tipo de antibiótico é excretado principalmente pelo sistema urinário, o meio selecionado foi uma mistura de sais predominantes na composição de urina, a qual apresenta alta concentração de diferentes íons, especialmente íons cloretos. As degradações eletroquímica e eletroquímica foto-assistida foram realizadas em uma célula de fluxo do tipo filtro-prensa, usando um ânodo dimensionalmente estável comercial com composição nominal Ti/Ru0,3Ti0,7O2. O decaimento da concentração do TeC foi determinado por cromatografia líquida de alta eficiência (CLAE) e a remoção da carga orgânica por análise de carbono orgânico total (COT). Os processos de degradação eletroquímica e eletroquímica foto-assistido utilizaram densidades de correntes de 20 a 40 mA cm-2 e concentração inicial de TeC de 200 mg L-1. Aplicando 30 mA cm-2, após duas horas a remoção de TeC foi de 91% e 98%, utilizando processo eletroquímico sem e com foto- assistência, respectivamente. A remoção de COT foi incompleta com um máximo de 17%. A fim de comparar o efeito da mistura salina sobre a degradação de TeC, as eletrólises também foram realizadas em NaCl 0,1 mol L-1, onde foi obtida degradação rápida e completa (100%) em ambos os processos, a remoção de COT também foi melhorada (~29%). A degradação de TeC obedeceu uma cinética de pseudo-primeira ordem. A degradação também foi avaliada utilizando os processos Fenton e foto-Fenton na mesma mistura salina variando a concentração inicial de H2O2 (50-150 mg L-1) e de Fe2+ (2,5-15 mg L-1). A concentração inicial de Fe2+ e H2O2 tem uma influência maior sobre a degradação durante ambos os processos. Durante o processo Fenton, sob condições otimizadas, a TeC foi degradada >96%, sendo 57% a redução de COT correspondente, enquanto em meio de NaCl ocorreu a remoção de 99% e redução de COT de 41%. Um ligeiro decaimento foi observado utilizando o processo foto-Fenton devido à influência de íons presentes no meio. Os intermediários de degradação também foram identificados por CLAE acoplado a espectrometria de massa durante os processos Fenton e foto-Fenton, sendo então proposta uma sequência reacional de degradação da TeC . / The degradation of antibiotics tetracycline (TeC) was evaluated by various processes such as electrochemical, photo-assisted electrochemical, Fenton and photo-Fenton. Since this type of antibiotic is excreted mainly by urinary system, the selected medium was a mixture of salts prevailing in composition of urine, which has high concentration of different ions, especially chloride ions. The electrochemical and photo-assisted electrochemical degradations were performed in a filter press type flow cell using a dimensionally stable anode with nominal composition of Ti/Ru0.3Ti0.7O2. The decrease in TeC concentration was analyzed by high performance liquid chromatography and total organic carbon analysis. The electrochemical and photo-assisted electrochemical degradation was performed at current densities of 20 to 40 mA cm-2 and initial TeC concentration of 200 mg L-1. At a current density of 30 mA cm-2,91% and 98% TeC was removed after 2 hours, during electrochemical and photo-assisted electrochemical processes respectively. The TOC removal was incomplete with maximum of 17%. In order to compare the TeC degradation in saline medium, electrolysis was also carried out in 0.1 mol L-1 NaCl, where fast and complete (100%) degradation was observed in both processes and TOC removal was also improved (~29 %). The degradation of TeC followed pseudo-first order kinetics. Fenton and Photo-Fenton process was also evaluated for the degradation of TeC in similar saline medium varying the initial concentration of H2O2 (50_150 mg L-1) and Fe2+ (2.5-15 mg L-1). The initial concentration of Fe2+ and H2O2 has a high influence upon TeC degradation during both processes. During Fenton process under optimized conditions, >96% of TeC was degraded and 57% TOC was removed. However in NaCl medium, 99% degradation 41% TOC was obtained. The degradation was slightly decreased during photo-Fenton process due to the influence of ions in the medium. The degradation Intermediates were also identified by HPLC coupled with mass spectrometer and proposed a reaction sequence for the degradation of TeC.
6

Degradação do antibiótico tetraciclina por vários processos em mistura salina / Degradation of antibiotic tetracycline by various processes in saline medium

Saima Gul 25 April 2014 (has links)
A degradação de antibiótico tetraciclina (TeC) foi avaliada por vários processos a saber, eletroquímico, eletroquímico foto-assistido, Fenton e foto-Fenton. Uma vez que este tipo de antibiótico é excretado principalmente pelo sistema urinário, o meio selecionado foi uma mistura de sais predominantes na composição de urina, a qual apresenta alta concentração de diferentes íons, especialmente íons cloretos. As degradações eletroquímica e eletroquímica foto-assistida foram realizadas em uma célula de fluxo do tipo filtro-prensa, usando um ânodo dimensionalmente estável comercial com composição nominal Ti/Ru0,3Ti0,7O2. O decaimento da concentração do TeC foi determinado por cromatografia líquida de alta eficiência (CLAE) e a remoção da carga orgânica por análise de carbono orgânico total (COT). Os processos de degradação eletroquímica e eletroquímica foto-assistido utilizaram densidades de correntes de 20 a 40 mA cm-2 e concentração inicial de TeC de 200 mg L-1. Aplicando 30 mA cm-2, após duas horas a remoção de TeC foi de 91% e 98%, utilizando processo eletroquímico sem e com foto- assistência, respectivamente. A remoção de COT foi incompleta com um máximo de 17%. A fim de comparar o efeito da mistura salina sobre a degradação de TeC, as eletrólises também foram realizadas em NaCl 0,1 mol L-1, onde foi obtida degradação rápida e completa (100%) em ambos os processos, a remoção de COT também foi melhorada (~29%). A degradação de TeC obedeceu uma cinética de pseudo-primeira ordem. A degradação também foi avaliada utilizando os processos Fenton e foto-Fenton na mesma mistura salina variando a concentração inicial de H2O2 (50-150 mg L-1) e de Fe2+ (2,5-15 mg L-1). A concentração inicial de Fe2+ e H2O2 tem uma influência maior sobre a degradação durante ambos os processos. Durante o processo Fenton, sob condições otimizadas, a TeC foi degradada >96%, sendo 57% a redução de COT correspondente, enquanto em meio de NaCl ocorreu a remoção de 99% e redução de COT de 41%. Um ligeiro decaimento foi observado utilizando o processo foto-Fenton devido à influência de íons presentes no meio. Os intermediários de degradação também foram identificados por CLAE acoplado a espectrometria de massa durante os processos Fenton e foto-Fenton, sendo então proposta uma sequência reacional de degradação da TeC . / The degradation of antibiotics tetracycline (TeC) was evaluated by various processes such as electrochemical, photo-assisted electrochemical, Fenton and photo-Fenton. Since this type of antibiotic is excreted mainly by urinary system, the selected medium was a mixture of salts prevailing in composition of urine, which has high concentration of different ions, especially chloride ions. The electrochemical and photo-assisted electrochemical degradations were performed in a filter press type flow cell using a dimensionally stable anode with nominal composition of Ti/Ru0.3Ti0.7O2. The decrease in TeC concentration was analyzed by high performance liquid chromatography and total organic carbon analysis. The electrochemical and photo-assisted electrochemical degradation was performed at current densities of 20 to 40 mA cm-2 and initial TeC concentration of 200 mg L-1. At a current density of 30 mA cm-2,91% and 98% TeC was removed after 2 hours, during electrochemical and photo-assisted electrochemical processes respectively. The TOC removal was incomplete with maximum of 17%. In order to compare the TeC degradation in saline medium, electrolysis was also carried out in 0.1 mol L-1 NaCl, where fast and complete (100%) degradation was observed in both processes and TOC removal was also improved (~29 %). The degradation of TeC followed pseudo-first order kinetics. Fenton and Photo-Fenton process was also evaluated for the degradation of TeC in similar saline medium varying the initial concentration of H2O2 (50_150 mg L-1) and Fe2+ (2.5-15 mg L-1). The initial concentration of Fe2+ and H2O2 has a high influence upon TeC degradation during both processes. During Fenton process under optimized conditions, >96% of TeC was degraded and 57% TOC was removed. However in NaCl medium, 99% degradation 41% TOC was obtained. The degradation was slightly decreased during photo-Fenton process due to the influence of ions in the medium. The degradation Intermediates were also identified by HPLC coupled with mass spectrometer and proposed a reaction sequence for the degradation of TeC.
7

Preparação de eletrodos de mistura de óxidos metálicos produzidos a partir de líquidos iônicos e avaliação do seu desempenho ante a eletrooxidação do Alaclor / Preparation of mixed metal oxide electrodes produced from ionic liquids and evaluation of their performance against the electrooxidation of Alachlor

Mello, Rodrigo de 26 February 2018 (has links)
O presente trabalho teve como objetivo a produção de ânodos de mistura de óxidos metálicos de composição nominal Ti/Ru0,3Ti0,7O2 utilizando um líquido iônico como solvente no preparo da solução precursora. A utilização deste tipo de solvente permite a síntese de materiais com morfologia e estrutura específicas, visto sua influência nas propriedades dos materiais. Neste trabalho foram utilizados líquidos iônicos baseados no imidazol, com o intuito de avaliar os efeitos do tamanho da cadeia carbônica ligada ao anel aromático heterocíclico, utilizando para comparação um eletrodo comercial (De Nora do Brasil). Por meio da caracterização física foi possível verificar que os eletrodos produzidos no laboratório apresentaram um filme mais compacto e com a formação de grânulos, o que indica um aumento na densidade de metais depositados. Além disso, o aumento na temperatura de calcinação favoreceu a deposição do óxido metálico catalítico (RuO2) na superfície do eletrodo ao se utilizar o hidrogenossulfato de 1-butilimidazólio ([HBIm]HSO4) como solvente na solução precursora. O eletrodo comercial apresentou uma área superficial superior aos eletrodos produzidos no laboratório, sendo a maior parte dessa área referente aos sítios internos desse eletrodo. O ânodo produzido utilizando [HBIm]HSO4 calcinado a 550 °C apresentou 15% mais remoção do pesticida alaclor em meio de sulfato que o eletrodo comercial, além de um consumo energético 16% menor. No caso das eletrólises realizadas na presença de cloreto, houve uma menor remoção do pesticida, apesar da melhora na resposta eletroquímica dos eletrodos nesse meio. Esse desempenho negativo pode estar relacionado à geração de substâncias que apresentam aderência à superfície dos eletrodos durante o processo de oxidação, obstruindo parcialmente a superfície ativa. / The present work aims to the production of mixed metal oxide anodes with nominal composition Ti/Ru0,3Ti0,7O2 using an ionic liquid as solvent in the preparation of the precursor solution. The use of this type of solvent allows the synthesis of materials with specific morphology and structure, since their influence on the properties of the materials. In this work, ionic liquids based on imidazole were used in order to evaluate the effects of the carbon chain size bonded to the heterocyclic aromatic ring, using a commercial electrode (De Nora do Brasil) for comparison. By means of the physical characterization, it was possible to verify that the laboratory made electrodes presented a more compact film with formation of granules, which indicates an increase in the deposited metal density. Moreover, the increase in the calcination temperature favored the deposition of the catalytic metal oxide (RuO2) on the surface of the electrode by using 1-butylimidazolium hydrogen sulfate ([HBIm]HSO4) as the solvent in the precursor solution. The commercial electrode presented a surface area superior to the laboratory made anodes, being the greater part of that area referring to the internal sites of this electrode. The anode produced using [HBIm]HSO4 calcined at 550 °C showed 15% more alachlor removal in sulfate medium than the commercial electrode, in addition to a 16% lower energy consumption. In the case of the electrolysis carried out in the presence of chloride, there was less pesticide removal, despite the improvement in the electrochemical response of the electrodes in this medium. This negative performance may be related to the generation of substances that have adhesion to the surface of the electrodes during the oxidation process, partially obstructing the active surface.
8

Degradação eletroquímica dos herbicidas atrazina e alaclor utilizando ânodo dimensionalmente estável comercial / Electrochemical degradation of atrazine and alachlor herbicides using dimensionally stable commercial anode

Sousa, Rafaely Ximenes de 19 February 2016 (has links)
A presença de defensivos agrícolas no meio ambiente, mesmo que em baixas concentrações (ng L-1/ μg L-1), representa uma potencial fonte de perturbação endócrina para os seres vivos. Neste cenário, destacam-se os herbicidas alaclor e atrazina, que são amplamente utilizados no combate a ervas daninhas. Entretanto, a Agência de Proteção Ambiental dos Estados Unidos (EPA) classifica como carcinogênicos, desreguladores endócrinos e seu limite, em água, não pode ultrapassar 2 e 3 μg L-1, respectivamente. O objetivo deste trabalho foi estudar a degradação eletroquímica do alaclor e atrazina, utilizando uma célula do tipo filtro-prensa, e um ânodo dimensionalmente estável (ADE) de composição nominal Ti/Ru0,3Ti0,7O2, pH inicial fixo em 3 e a temperatura em 25 ºC, uma vez que, os métodos convencionais de tratamento não são totalmente eficientes na remoção destes compostos orgânicos nos sistemas aquosos. Inicialmente realizou-se apenas a degradação eletroquímica do herbicida alaclor (100 mg L-1) via planejamento fatorial de ponto central do tipo 32, tendo como variáveis, a concentração do eletrólito suporte cloreto de sódio (0,05, 01 e 0,15 g L-1) e a densidade de corrente (10, 30 e 50 mA cm-2), obtendo como melhor resposta, 93,45 % de remoção e 71,6 % de mineralização, ao usar CNaCl de 0,15 g L-1 e 50 mA cm-2. Porém, a CNaCl de 0,15 g L-1 e densidade de 30 mA cm-2 foi escolhida como a melhor condição estudada, em virtude do seu menor valor de consumo energético e por apresentar a taxa de remoção (93,6%) e mineralização (71,24%) próximas ao uso da maior densidade de corrente. Só então, na melhor condição, obtida previamente a partir dos experimentos de degradação do alaclor, que realizou-se a oxidação de 100 mg L-1 de atrazina e da mistura dos herbicidas. Também foi observado uma cinética de pseudo primeira ordem na oxidação dos herbicidas, e, além disso, foi realizada a identificação dos intermediários e/ou produtos de degradação do alaclor e atrazina através da técnica de CLAE acoplada a um espectrômetro de massas. / The pesticides presence in environment represents a potential endocrine disturbance source for the living beings, even in low concentrations (ng L-1/ μg L-1). The herbicides alachlor and atrazine are important to highlight, these herbicides are widely used to combat weeds herbs. However, the Environmental Protection Agency (EPA) classifies alachlor and atrazine as carcinogens, endocrine disruptors and their water limit may not exceed 2 and 3 μg L-1, respectively. The aim of this work was to study the electrochemical degradation of alachlor and atrazine, using a filter-press cell, and a dimensionally stable anode (DSA) with a nominal composition Ti/Ru0.3Ti0.7O2, fixed initial pH of 3 and temperature of 25ºC. The conventional treatment methods are not completely effective to remove these organic compounds in aqueous systems. Initially, only an electrochemical degradation of alachlor (100 mg L-1) was made by factorial design center point type 32, considering as variables: the supporting electrolyte sodium chloride concentration (0.05, 0.1 and 0.15 g L-1) and current density (10, 30 and 50 mA cm-2). In this initial degradation was obtained as better result: 93.45% of removal and 71.6% of mineralization of alachlor, using CNaCl of 0.15 g L-1 and 50 mA cm-2. However, CNaCl of 0.15 g L-1 and a density of 30 mA cm-2 was chosen as the best condition studied, in the reason of its lower energy consumption value and presents a removal rate (93.6%) and the mineralization (71.24%) closer to the use of higher current density. The electrolyses of 100 mg L-1 of atrazine and the herbicides mixture were performed only in the best condition, previously obtained with alachlor degradation experiments. In addition, a kinetic of pseudo first order for both herbicides and their mixture oxidation was observed, and besides, the identification of intermediates and/or degradation products of alachlor and atrazine was performed by liquid chromatography coupled to mass spectrometry (LC-MS).
9

Degradação eletroquímica dos herbicidas atrazina e alaclor utilizando ânodo dimensionalmente estável comercial / Electrochemical degradation of atrazine and alachlor herbicides using dimensionally stable commercial anode

Rafaely Ximenes de Sousa 19 February 2016 (has links)
A presença de defensivos agrícolas no meio ambiente, mesmo que em baixas concentrações (ng L-1/ μg L-1), representa uma potencial fonte de perturbação endócrina para os seres vivos. Neste cenário, destacam-se os herbicidas alaclor e atrazina, que são amplamente utilizados no combate a ervas daninhas. Entretanto, a Agência de Proteção Ambiental dos Estados Unidos (EPA) classifica como carcinogênicos, desreguladores endócrinos e seu limite, em água, não pode ultrapassar 2 e 3 μg L-1, respectivamente. O objetivo deste trabalho foi estudar a degradação eletroquímica do alaclor e atrazina, utilizando uma célula do tipo filtro-prensa, e um ânodo dimensionalmente estável (ADE) de composição nominal Ti/Ru0,3Ti0,7O2, pH inicial fixo em 3 e a temperatura em 25 ºC, uma vez que, os métodos convencionais de tratamento não são totalmente eficientes na remoção destes compostos orgânicos nos sistemas aquosos. Inicialmente realizou-se apenas a degradação eletroquímica do herbicida alaclor (100 mg L-1) via planejamento fatorial de ponto central do tipo 32, tendo como variáveis, a concentração do eletrólito suporte cloreto de sódio (0,05, 01 e 0,15 g L-1) e a densidade de corrente (10, 30 e 50 mA cm-2), obtendo como melhor resposta, 93,45 % de remoção e 71,6 % de mineralização, ao usar CNaCl de 0,15 g L-1 e 50 mA cm-2. Porém, a CNaCl de 0,15 g L-1 e densidade de 30 mA cm-2 foi escolhida como a melhor condição estudada, em virtude do seu menor valor de consumo energético e por apresentar a taxa de remoção (93,6%) e mineralização (71,24%) próximas ao uso da maior densidade de corrente. Só então, na melhor condição, obtida previamente a partir dos experimentos de degradação do alaclor, que realizou-se a oxidação de 100 mg L-1 de atrazina e da mistura dos herbicidas. Também foi observado uma cinética de pseudo primeira ordem na oxidação dos herbicidas, e, além disso, foi realizada a identificação dos intermediários e/ou produtos de degradação do alaclor e atrazina através da técnica de CLAE acoplada a um espectrômetro de massas. / The pesticides presence in environment represents a potential endocrine disturbance source for the living beings, even in low concentrations (ng L-1/ μg L-1). The herbicides alachlor and atrazine are important to highlight, these herbicides are widely used to combat weeds herbs. However, the Environmental Protection Agency (EPA) classifies alachlor and atrazine as carcinogens, endocrine disruptors and their water limit may not exceed 2 and 3 μg L-1, respectively. The aim of this work was to study the electrochemical degradation of alachlor and atrazine, using a filter-press cell, and a dimensionally stable anode (DSA) with a nominal composition Ti/Ru0.3Ti0.7O2, fixed initial pH of 3 and temperature of 25ºC. The conventional treatment methods are not completely effective to remove these organic compounds in aqueous systems. Initially, only an electrochemical degradation of alachlor (100 mg L-1) was made by factorial design center point type 32, considering as variables: the supporting electrolyte sodium chloride concentration (0.05, 0.1 and 0.15 g L-1) and current density (10, 30 and 50 mA cm-2). In this initial degradation was obtained as better result: 93.45% of removal and 71.6% of mineralization of alachlor, using CNaCl of 0.15 g L-1 and 50 mA cm-2. However, CNaCl of 0.15 g L-1 and a density of 30 mA cm-2 was chosen as the best condition studied, in the reason of its lower energy consumption value and presents a removal rate (93.6%) and the mineralization (71.24%) closer to the use of higher current density. The electrolyses of 100 mg L-1 of atrazine and the herbicides mixture were performed only in the best condition, previously obtained with alachlor degradation experiments. In addition, a kinetic of pseudo first order for both herbicides and their mixture oxidation was observed, and besides, the identification of intermediates and/or degradation products of alachlor and atrazine was performed by liquid chromatography coupled to mass spectrometry (LC-MS).
10

Preparação de eletrodos de mistura de óxidos metálicos produzidos a partir de líquidos iônicos e avaliação do seu desempenho ante a eletrooxidação do Alaclor / Preparation of mixed metal oxide electrodes produced from ionic liquids and evaluation of their performance against the electrooxidation of Alachlor

Rodrigo de Mello 26 February 2018 (has links)
O presente trabalho teve como objetivo a produção de ânodos de mistura de óxidos metálicos de composição nominal Ti/Ru0,3Ti0,7O2 utilizando um líquido iônico como solvente no preparo da solução precursora. A utilização deste tipo de solvente permite a síntese de materiais com morfologia e estrutura específicas, visto sua influência nas propriedades dos materiais. Neste trabalho foram utilizados líquidos iônicos baseados no imidazol, com o intuito de avaliar os efeitos do tamanho da cadeia carbônica ligada ao anel aromático heterocíclico, utilizando para comparação um eletrodo comercial (De Nora do Brasil). Por meio da caracterização física foi possível verificar que os eletrodos produzidos no laboratório apresentaram um filme mais compacto e com a formação de grânulos, o que indica um aumento na densidade de metais depositados. Além disso, o aumento na temperatura de calcinação favoreceu a deposição do óxido metálico catalítico (RuO2) na superfície do eletrodo ao se utilizar o hidrogenossulfato de 1-butilimidazólio ([HBIm]HSO4) como solvente na solução precursora. O eletrodo comercial apresentou uma área superficial superior aos eletrodos produzidos no laboratório, sendo a maior parte dessa área referente aos sítios internos desse eletrodo. O ânodo produzido utilizando [HBIm]HSO4 calcinado a 550 °C apresentou 15% mais remoção do pesticida alaclor em meio de sulfato que o eletrodo comercial, além de um consumo energético 16% menor. No caso das eletrólises realizadas na presença de cloreto, houve uma menor remoção do pesticida, apesar da melhora na resposta eletroquímica dos eletrodos nesse meio. Esse desempenho negativo pode estar relacionado à geração de substâncias que apresentam aderência à superfície dos eletrodos durante o processo de oxidação, obstruindo parcialmente a superfície ativa. / The present work aims to the production of mixed metal oxide anodes with nominal composition Ti/Ru0,3Ti0,7O2 using an ionic liquid as solvent in the preparation of the precursor solution. The use of this type of solvent allows the synthesis of materials with specific morphology and structure, since their influence on the properties of the materials. In this work, ionic liquids based on imidazole were used in order to evaluate the effects of the carbon chain size bonded to the heterocyclic aromatic ring, using a commercial electrode (De Nora do Brasil) for comparison. By means of the physical characterization, it was possible to verify that the laboratory made electrodes presented a more compact film with formation of granules, which indicates an increase in the deposited metal density. Moreover, the increase in the calcination temperature favored the deposition of the catalytic metal oxide (RuO2) on the surface of the electrode by using 1-butylimidazolium hydrogen sulfate ([HBIm]HSO4) as the solvent in the precursor solution. The commercial electrode presented a surface area superior to the laboratory made anodes, being the greater part of that area referring to the internal sites of this electrode. The anode produced using [HBIm]HSO4 calcined at 550 °C showed 15% more alachlor removal in sulfate medium than the commercial electrode, in addition to a 16% lower energy consumption. In the case of the electrolysis carried out in the presence of chloride, there was less pesticide removal, despite the improvement in the electrochemical response of the electrodes in this medium. This negative performance may be related to the generation of substances that have adhesion to the surface of the electrodes during the oxidation process, partially obstructing the active surface.

Page generated in 0.5316 seconds