• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 596
  • 371
  • 93
  • 34
  • 13
  • 12
  • 12
  • 12
  • 12
  • 12
  • 12
  • 6
  • 6
  • 5
  • 4
  • Tagged with
  • 1295
  • 599
  • 261
  • 163
  • 116
  • 99
  • 97
  • 95
  • 95
  • 93
  • 90
  • 88
  • 84
  • 84
  • 74
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Analysis of crosstalk signals in a cylindrical layered volume conductor influence of the anatomy, detection system and physical properties of the tissues /

Viljoen, Suretha. January 2005 (has links)
Thesis (M.Eng.)(Bioengineering)--University of Pretoria, 2005. / Title from opening screen (viewed March 22, 2006). Includes summaries in English and Afrikaans. Includes bibliographical references.
72

Effects of isometric elbow flexion on electromyographic spike analysis

Lester, Steven M. January 1900 (has links)
Thesis (M.S.)--Brock University, 2005. / Includes bibliographical references (leaves 95-109). Also available online (PDF file) by a subscription to the set or by purchasing the individual file.
73

Effects of isometric elbow flexion on electromyographic spike analysis

Lester, Steven M. January 2005 (has links)
Thesis (M.Sc.)--Brock University, 2005. / Includes bibliographical references (leaves 95-109).
74

Biomechanical measures as a function of cycle time in an occupational hand transfer task /

Escorpizo, Reuben S. January 2005 (has links)
Thesis (M.Sc.)--York University, 2005. Graduate Programme in Kinesiology and Health Science. / Typescript. Includes bibliographical references (leaves 83-88). Also available on the Internet. MODE OF ACCESS via web browser by entering the following URL: http://gateway.proquest.com/openurl?url%5Fver=Z39.88-2004&res%5Fdat=xri:pqdiss &rft_val_fmt=info:ofi/fmt:kev:mtx:dissertation&rft_dat=xri:pqdiss:MR11782
75

Assessment of human muscle fatigue from surface EMG signals recorded during isometric voluntary contractions by using a cosine modulated filter bank

Potes, Cristhian Mauricio. January 2008 (has links)
Thesis (M.S.)--University of Texas at El Paso, 2008. / Title from title screen. Vita. CD-ROM. Includes bibliographical references. Also available online.
76

Analise eletromiográfica e dinamométrica durante o ciclio da pedalada em cicloergômetro aquático

Ribeiro, Maria Auxiliadora Andrade Pinto [UNESP] 30 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:34:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-30Bitstream added on 2014-06-13T20:08:27Z : No. of bitstreams: 1 ribeiro_maap_dr_guara.pdf: 1262118 bytes, checksum: ef7340daffce87dd126dd3caf2410834 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / No ciclismo aquático os músculos dos membros inferiores são responsáveis pela produção da força, a qual, aplicada sobre o pedal e transmitida ao pé-de-vela, impulsiona a bicicleta aquática. Estudos das forças aplicadas sobre o pedal são de grande interesse para a Biomecânica do ciclismo, especialmente quando estas se encontram associadas à técnica da eletromiografia. Os objetivos deste estudo foram: (1) construir um pedal com o eixo instrumentado com extensômetros para medir a Força Normal média aplicada sobre o pedal da bicicleta aquática; (2) Verificar a magnitude dos sinais eletromiográficos dos músculos do membro inferior direito, reto femoral (RF), bíceps femoral (BF) e gastrocnêmio lateral (GAL) na fase de propulsão do ciclo da pedalada; (3) Verificar a existência de correlação entre a intensidade do sinal eletromiográfico e os da Força Normal média aplicada sobre o pedal nos três níveis de controle de fluxo de água presentes na Hidrocycle. Participaram deste estudo 5 voluntários do sexo masculino, com idade média 22 ± 1,9, massa corporal 75 kg ± 3,8, estatura 176 cm ± 3,3. Os ensaios procederam em um tanque de dimensões externas 1,2 m x 1,0 m x 1,5 m, respectivamente, comprimento, largura e altura, partes laterais de vidro, no qual a Hidrocycle foi instalada. Os voluntários pedalaram a uma frequência de 50 rpm, por um período de 1 minuto, nos três níveis de resistência aquática pré-estabelecida pela Hidrocycle. Com a aplicação crescente das cargas devido à abertura ou fechamento dos dois furos presentes em cada uma das quatro calhas da bicicleta foram obtidos os resultados. O músculo GAL apresentou aumento estatisticamente significativo dos RMSm para os dois furos abertos (2FA) (17,00 mV ± 2,44), um furo fechado (1FF) (19,50 mV ± 1,80) e dois furos fechados (2FF) (34,40 mV ± 8,24). Para o músculo RF também foi observado aumento... / At the aquatics cycling the muscles of the lower limbs are responsible for the force production which, applied make the aquatics bicycle move ahead. Studies of the forces applied on the pedal are of great interest for the cycling Biomechanics, especially when these are associated with the EMG technique. The aims of this study were: (1) to build a instrumental pedal with strain gauges to measure average normal force applied on the aquatics bicycle pedal; (2) to check amount of EMG signals of the muscles of the right lower limb, RF muscle, BF muscle and GAL muscle and phase of the propulsion of the pedal ride; (3) to check the correlation existing between the EMG signal intensity pedal force at the three levels of water resistance. Five male volunteers with average age 22 ± 1,9, body weight 75 kg ± 3, 8, 176 cm ± 3,3 height participated on this experiments. The experiments happened at a tank with external dimensions of 1,2 m x 1,0m x 1,5 m, length, width and height, glass side walls, in with the Hidrocycle was installed. The volunteers cycled at a frequency of 50 rpm, for one minutes, during the three levels of aquatic resistance previously established by the Hidrocycle. With the rising use of loads due to the opining and closing process of the two holes present in each of the four gutters of the bicycle, the results were obtained. The muscle GAL presented significant RMSm increase related to the two open holes levels (2FA) (17,00 mV± 2,44), one close holes (1FF) (19,50 mV± 1,80) and two close holes (2FF) (34,40 mV± 8,24). For the muscle RF, a significant RMSm increase was also found: 2FA (14,40 mV± 5,08), 1FF (17,70 mV± 3,36) and 2FF (20,00 ± 15,21). The muscle BF hasn’t presented any significant increase for 1FF (30, 00 mV± 12,58), put to FA ( 25,80 ± 18,57) and 2FF (34,40 ± 20,46) slowed significant RMSm increase for p<0,05. Concerning the correlation between RMSm... (Complete abstract click electronic access below)
77

Avaliação da função mastigatória de sujeitos assintomáticos para disfunção temporomandibular através da eletromiografia e da eficiência mastigatória pelo método colorimétrico / Evaluation of masticatory function of subjects asymptomatic for temporomandibular dysfunction through electromyography and masticatory efficiency by colorimetric method

Mateus Sgobi Cazal 18 December 2013 (has links)
O objetivo deste estudo foi avaliar a função mastigatória de sujeitos adultos jovens assintomáticos para Disfunção Temporomandibular (DTM), utilizando eletromiografia (EMG) de superfície e teste de eficiência mastigatória (EM). A partir destes testes, analisar as variáveis eletromiográficas durante a mastigação de materiais (naturais e artificiais) de diferentes texturas, a fim de verificar se: diferentes texturas alimentares promovem diferentes valores de índice eletromiográficos; o índice de simetria mastigatória com a cápsula mastigatória se assemelha a algum alimento natural testado. A amostra foi composta por 30 sujeitos adultos jovens saudáveis, com idade média de 23,46 anos (variando de 18 a 29 anos), sendo 15 homens e 15 mulheres, assintomáticos para DTM, ambos confirmados por exame clínico odontológico e seguindo a classificação proposta pelo protocolo do Research Diagnostic Criteria for Temporomandibular Disorders - RDC/ TMD. Os sujeitos foram submetidos a uma anamnese sobre o comportamento mastigatório incluindo perguntas sobre hábitos e dificuldades mastigatórias. Também foram realizados exame clínico de oclusão e posterior análise EMG (Eletromiógrafo Freely - De Götzen srl; Legano, Milano, Italy) e de EM utilizando cápsulas mastigatória (Sistema de avaliação da Eficiência Mastigatória: ME-mastig - FORP, FCFRP/USP). Os registros eletromiográficos foram realizados em etapas: teste de normalização (Máxima Contração Voluntária com roletes de algodão), teste estático (Máxima Contração Voluntária em Máxima Intercuspidação Habitual) e teste dinâmico (mastigação de goma, uva passa, cápsula mastigatória e amendoim - à direita, esquerda e habitual). Os valores de EM foram obtidos durante a mastigação da cápsula concomitante ao teste dinâmico. Os valores EMG e EM obtidos foram submetidos ao Teste Komogorov-Smirnov, apresentando distribuição normal. Os dados experimentais foram analisados estatisticamente pela Análise de Variância (ANOVA-paramétrico) para os valores de EMG e EM encontrados nos sujeitos da pesquisa. O Teste de Tukey (p&le;0,05) foi utilizado para múltiplas comparações. Os resultados EMG do teste estático foram: POCT 84,03%; POCM 85,20%; TORS 10,90%; ASSIM 1,80%; ATTIV -6,85%; IMPACT 104,43%; e os resultados do teste dinâmico foram: goma: Ciclo 22,86; Freq 1,52 Hz; SIMETRIA 43,11%; IMPACT 2590,97 &mu;V/ &mu;V.s%; uva passa: Ciclo 22,93; Freq 1,54 Hz; SIMETRIA 52,62%; IMPACT 3632,49 &mu;V/ &mu;V.s%; cápsula: Ciclo 23,03; Freq 1,53 Hz; SIMETRIA 29,69%; IMPACT 4028,58 &mu;V/ &mu;V.s%; amendoim: Ciclo 24,10; Freq 1,60 Hz; SIMETRIA 44,40%; IMPACT 4498,43 &mu;V/ &mu;V.s%. O Teste de Tukey (p&le;0,05) foi utilizado para múltiplas comparações e para todos os materiais testados Ciclo e Frequência foram considerados semelhantes. Para SIMETRIA, goma, uva passa e cápsula foram semelhantes e diferentes do amendoim, assim como uva passa, cápsula e amendoim foram semelhantes e diferentes da goma. Para IMPACTO, uva passa, cápsula e amendoim e diferentes da goma. Os valores de EM direita (0,66 &mu;g/ml), esquerda (0,60 &mu;g/ml) e habitual (0,61 &mu;g/ml) foram considerados semelhantes. A partir dos resultados, foi possível concluir que a função mastigatória foi satisfatória para os materiais utilizados, e a cápsula mastigatória apresentou todos os índices EMG analisados semelhantes aos obtidos com os alimentos naturais de diferentes texturas. / The aim of this study was to evaluate the masticatory function of subjects asymptomatic young adults for Temporomandibular Disorders (TMD) using surface lectromyography (EMG) and testing of masticatory efficiency (ME). From these tests, examine the EMG variables during mastication of materials (natural and artificial) of different textures in order to check that: different food textures promote different electromyographic index values, the rate of symmetry with masticatory chewing the capsule is resembles some natural food tested. The sample consisted of 30 healthy young adult subjects with a mean age of 23.46 years (range 18-29 years), 15 men and 15 women, with no symptoms of TMD, both confirmed by dental examination and following the classification proposed protocol by Research Diagnostic Criteria for Temporomandibular Disorders - RDC/ TMD. The subjects were submitted to an interview on the chewing behavior including questions about habits and chewing difficulty. Were also carried out clinical examination and subsequent occlusion EMG analysis (Electromyograph Freely - De Götzen srl; Legano, Milano, Italy) and ME using capsules masticatory system (Masticatory Efficiency assessment: ME- mastig - FORP, FCFRP/ USP). The EMG recordings were performed in stages: test standards (Maximum Voluntary Contraction with cotton rolls), static test (Maximum Voluntary Contraction in maximal intercuspal Habitual) and dynamic testing (chewing gum, raisins, peanut and capsule chewing right, left and habitual). ME values were obtained during chewing the capsule concomitant dynamic test. EMG values and ME were submitted to Test Komogorov-Smirnov test showed normal distribution. The experimental data were statistically analyzed by analysis of variance (ANOVA - parametric) for values of EMG and ME found in research subjects. The Tukey test (p&le; 0.05) was used for multiple comparisons. The EMG static test results were: POCT 84.03%, POCM 85.20%; TORS 10.90%, ASSIM 1.80%; ATTIV -6.85%, IMPACT 104.43%, and the test results dynamic were: gum: Cycle 22.86; Freq 1.52Hz; SIMETRIA 43.11%; IMPACT 2590.97&mu;V/&mu;V.s%; raisins: Cycle 22.93; Freq 1.54Hz; SYIMETRIA 52,62%; IMPACT 3632.49&mu;V/&mu;V.s%; capsule: Cycle 23.03; Freq 1.53Hz; SYMMETRY 29.69%; IMPACT 4028.58&mu;V/&mu;V.s%; peanuts: Cycle 24.10, Freq 1.60Hz; SIMETRIA 44.40%; IMPACT 4498.43&mu;V/ &mu;V.s%. The Tukey test (p&le; 0.05) was used for multiple comparisons and for all tested materials cycle and frequency were considered similar. To SIMETRIA, gum, raisins and capsule were similar and different peanut, as well as raisins, peanut and capsule were similar and different gum. For IMPACT, raisins, peanuts and different capsule and gum. The values of ME right (0.66&mu;g/ml), left (0.60&mu;g/ml) and usual (0.61&mu;g/ml) was considered similar. From the results, it was concluded that the masticatory function was satisfactory for the materials used, and the capsule masticatory EMG showed all indices analyzed similar to those obtained with the natural foods of different textures.
78

Analise eletromiográfica e dinamométrica durante o ciclio da pedalada em cicloergômetro aquático /

Ribeiro, Maria Auxiliadora Andrade Pinto. January 2011 (has links)
Orientador: João Alberto de Oliveira / Banca: Tamotsu Hirata / Banca: José Elias Tomazini / Banca: Renato de Sousa Almeida / Banca: Luiz Heleno Moreira Duque / Resumo: No ciclismo aquático os músculos dos membros inferiores são responsáveis pela produção da força, a qual, aplicada sobre o pedal e transmitida ao pé-de-vela, impulsiona a bicicleta aquática. Estudos das forças aplicadas sobre o pedal são de grande interesse para a Biomecânica do ciclismo, especialmente quando estas se encontram associadas à técnica da eletromiografia. Os objetivos deste estudo foram: (1) construir um pedal com o eixo instrumentado com extensômetros para medir a Força Normal média aplicada sobre o pedal da bicicleta aquática; (2) Verificar a magnitude dos sinais eletromiográficos dos músculos do membro inferior direito, reto femoral (RF), bíceps femoral (BF) e gastrocnêmio lateral (GAL) na fase de propulsão do ciclo da pedalada; (3) Verificar a existência de correlação entre a intensidade do sinal eletromiográfico e os da Força Normal média aplicada sobre o pedal nos três níveis de controle de fluxo de água presentes na Hidrocycle. Participaram deste estudo 5 voluntários do sexo masculino, com idade média 22 ± 1,9, massa corporal 75 kg ± 3,8, estatura 176 cm ± 3,3. Os ensaios procederam em um tanque de dimensões externas 1,2 m x 1,0 m x 1,5 m, respectivamente, comprimento, largura e altura, partes laterais de vidro, no qual a Hidrocycle foi instalada. Os voluntários pedalaram a uma frequência de 50 rpm, por um período de 1 minuto, nos três níveis de resistência aquática pré-estabelecida pela Hidrocycle. Com a aplicação crescente das cargas devido à abertura ou fechamento dos dois furos presentes em cada uma das quatro calhas da bicicleta foram obtidos os resultados. O músculo GAL apresentou aumento estatisticamente significativo dos RMSm para os dois furos abertos (2FA) (17,00 mV ± 2,44), um furo fechado (1FF) (19,50 mV ± 1,80) e dois furos fechados (2FF) (34,40 mV ± 8,24). Para o músculo RF também foi observado aumento... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: At the aquatics cycling the muscles of the lower limbs are responsible for the force production which, applied make the aquatics bicycle move ahead. Studies of the forces applied on the pedal are of great interest for the cycling Biomechanics, especially when these are associated with the EMG technique. The aims of this study were: (1) to build a instrumental pedal with strain gauges to measure average normal force applied on the aquatics bicycle pedal; (2) to check amount of EMG signals of the muscles of the right lower limb, RF muscle, BF muscle and GAL muscle and phase of the propulsion of the pedal ride; (3) to check the correlation existing between the EMG signal intensity pedal force at the three levels of water resistance. Five male volunteers with average age 22 ± 1,9, body weight 75 kg ± 3, 8, 176 cm ± 3,3 height participated on this experiments. The experiments happened at a tank with external dimensions of 1,2 m x 1,0m x 1,5 m, length, width and height, glass side walls, in with the Hidrocycle was installed. The volunteers cycled at a frequency of 50 rpm, for one minutes, during the three levels of aquatic resistance previously established by the Hidrocycle. With the rising use of loads due to the opining and closing process of the two holes present in each of the four gutters of the bicycle, the results were obtained. The muscle GAL presented significant RMSm increase related to the two open holes levels (2FA) (17,00 mV± 2,44), one close holes (1FF) (19,50 mV± 1,80) and two close holes (2FF) (34,40 mV± 8,24). For the muscle RF, a significant RMSm increase was also found: 2FA (14,40 mV± 5,08), 1FF (17,70 mV± 3,36) and 2FF (20,00 ± 15,21). The muscle BF hasn't presented any significant increase for 1FF (30, 00 mV± 12,58), put to FA ( 25,80 ± 18,57) and 2FF (34,40 ± 20,46) slowed significant RMSm increase for p<0,05. Concerning the correlation between RMSm... (Complete abstract click electronic access below) / Doutor
79

Desenvolvimento de um software para aquisição e tratamento de sinais eletromiográficos: implementação e resultados / Software for aquisition and treatment of electromiography signals: implementation and results

Daniela Silveira dos Santos 25 October 2004 (has links)
A partir do espectro de freqüência do sinal eletromiográfico pode-se calcular a freqüência mediana, a freqüência média e a moda da freqüência, podendo se avaliar a fadiga muscular de um indivíduo. Atualmente as análises miográficas, do Depto de Fisioterapia da UNESP - Presidente Prudente, a coleta das medidas e a análise dos resultados são feitas em sistemas separados, isto é, há um sistema para aquisição dos sinais miográficos e outro para análise dos dados, em computadores diferentes. Isto causa problemas pois o indivíduo é submetido ao exercício e somente depois do exercício concluído o sinal é analisado. Com a intenção de melhorar a análise dos sinais miográficos foi desenvolvido um programa computacional no qual os cálculos de FFT e o tratamento do sinal são feitos simultaneamente a aquisição, isto é, em tempo real. A grande vantagem é a possibilidade de se corrigir possíveis erros durante a aquisição devidos a eletrodos mal posicionados, ruídos, evitar o cansaço excessivo do paciente ou até detectar um possível processo de lesão musculara antes que este ocorra. O aplicativo foi implementado em linguagem Visual Basic e rotinas do Matlab, encontra-se em funcionamento e os resultados práticos são discutidos neste trabalho. / From the frequency spectrum of a electromiographic signal the frequency mediana, the mean frequency and the frequency modal can be calculated. Using such parameters the muscular fading of a patient can be evaluated, for instance, using the FFT procedure. In the Phisiotherapy Department of Unesp at Presidente Prudente, experimental data are collected and analyzed using two separated systems. The data corresponding to the electro miographic signal are measured in the first step and then transferred and analyzed in another computer. This procedure is not straightforward since the patient is submitted to a given exercise and only after finishing it the data could be analyzed. Aiming to improve the analysis of the electromiographic signals a software was developed allowing the FFT calculations and the signal analysis to be performed during the data acquisition. The advantage is the possibility to adjust and correct the experimental procedure during the acquisition. Effects of electrodes malpositioning on the patient, electrical noise and excessive fatigue of the patient or even it is possible to detect a muscular lesion during the exercise. The software was developed in the Visual Basic language and using Matlab routines, it is now running and practical results are discussed in this work.
80

Estudo eletromiográfico dos músculos tensor da fáscia lata e sartório em repouso e durante diferentes movimentos

Carvalho Filho, João, 1951- 24 August 2018 (has links)
Orientador: Fausto Bérzin / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T16:33:19Z (GMT). No. of bitstreams: 1 CarvalhoFilho_Joao_D.pdf: 1313807 bytes, checksum: 07c697e23cd343e1036e760b59f915e9 (MD5) Previous issue date: 2014 / Resumo: Introdução: A eletromiografia intramuscular (EMG) é uma técnica invasiva que detecta a atividade muscular através de agulhas-eletrodo ou fios inseridos nos músculos, que têm alta seletividade para os diferentes potenciais de ação da unidade motora. O uso clínico atual de sinais EMG intramusculares refere-se ao diagnóstico de miopatias, doenças do neurônio motor alfa e da junção neuromuscular, por meio da análise do sinal de interferência ou da forma de alguns potenciais de ação da unidade motora, geralmente sem uma completa decomposição do sinal. Justificativa: Os escassos trabalhos sobre a cinesiologia dos mm. sartório e tensor da fáscia lata referidos na literatura clássica, foram feitos utilizando-se equipamentos analógicos, que não permitem quantificação matemática do sinal eletromiográfico, produzindo resultados de valor apenas empírico. Por isso, fez-se necessário estudar a cinesiologia dos Mm sartório e tensor da fáscia lata, por meio de equipamento eletromiográfico digital que forneceu resultados mais precisos e confiáveis, passíveis de avaliação matemática, normalizados e submetidos à análise estatística adequada. Objetivo: O presente trabalho objetivou a avaliação eletromiográfica por meio de equipamento digital, da cinesiologia dos músculos sartório e tensor da fáscia lata do lado direito, em indivíduos normais, destros, em repouso e durante diferentes movimentos corporais. Metodologia: Uma amostra de 15 voluntários, de ambos os sexos, independente de etnia, faixa etária de 20 a 30 anos foi estudada a partir de um Eletromiógrafo Data Hominis Ltda. (versão 2.9) e Pré-amplificador da Linx Tecnologia Eletrônica Ltda. Modelo PA1010-VA. Os músculos foram avaliados unilateralmente (lado direito) e a ação muscular foi captada no repouso e durante a execução de vários movimentos corporais. Os dados foram analisados estatisticamente através do teste Scott-Knott e o nível de significância foi de 5% (p<0,05). Resultados obtidos: O músculo sartório se apresentou muito ativo no movimento 1; ativo nos movimentos 3, 5 e 6; atividade moderada nos movimentos 4, 11, 12 e 28, e pouco ativo nos demais; já o músculo tensor da fáscia lata foi muito ativo nos movimentos 3 e 6; ativo no movimento 5; atividade moderada nos movimentos 1, 2 e 4 e pouco ativo nos demais. Conclusão: Conclui-se então a partir dos resultados obtidos que o uso do eletromiógrafo digital, mostrou um sinal muito mais eficiente que o analógico, o que propiciou uma análise matemática e estatística muito mais acurada dos resultados obtidos nas coletas realizadas / Abstract: Introduction: Intramuscular electromyography (EMG), an invasive technique that detects muscle activity through needle electrodes or wires inserted into the muscles, has a high selectivity for different action potentials of the motor unit. Nowadays, the clinical use of intramuscular EMG signals refers to the diagnose of myopathies, alpha-motor neuron and neuromuscular junction diseases by means of analysis of the interference signal or shape of some action potentials of the motor unit, generally without a complete signal decomposition. Justification: the sparse researches on the kinesiology of tensor fasciae latae and sartorius found in classical literature were performed with analogical equipment which does not allow mathematical quantification of EMG signal, resulting only in empirical data. Thus, it was necessary to study the kinesiology of tensor fasciae latae and sartorius through EMG digital equipment that supplies more precise and reliable results which can be mathematically evaluated, normalized and submitted to an adequate statistical analysis. Objective: the present research aimed to perform a digital EMG evaluation of the kinesiology of right tensor fasciae latae and sartorius in dexterous normal individuals at rest and during different body movements. Methods: a sample of 15 non-ethnical volunteers of both sexes, ranging from 20 to 30 years old was studied using a Data Hominis Ltda. (version 2.9) Electromyography set and a PA1010-VA model of Linx Tecnologia Eletrônica Ltda. preamplifier. The right-sided muscles were evaluated and the muscle action taken at rest and during several body movement performance. Data were statistically analyzed through Scott-Knott test and the significance level was of 5% (p<0.05). Results: Sartorius showed to be much active in movement 1; active in movements 3, 5 and 6; moderate active in movements 4, 11, 12 and 28; and less active in the others. Tensor fasciae latae was much active in movements 3 and 6; active in movement 5; moderate active in movements 1, 2 and 4; and less active in the others. Conclusion: the data obtained in the research showed that digital EMG displayed a much more efficient signal than analogical one that allows an even more accurate mathematical and statistical analysis of data taken in our study / Doutorado / Anatomia / Doutor em Biologia Buco-Dental

Page generated in 0.0872 seconds