• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The Role of Competitive Intelligence in Strategic Decision Making for Commercializing a Novel Endovascular Navigation Technology

Sobel, Ryan A. 21 June 2021 (has links)
No description available.
2

Tracking de dispositifs et de structures pour le traitement endovasculaire des pathologies aortiques / Tracking of devices and of structures for the endovascular treatment of aortic pathologies

Nguyen-Duc, Long Hung 14 December 2017 (has links)
Ces travaux s’inscrivent dans le cadre de la navigation endovasculaire assistée par ordinateur. L’objectif principal est d’étudier et de proposer de nouvelles solutions pour la localisation et le suivi des dispositifs endovasculaires en mouvement par rapport aux structures anatomiques, considérées comme immobiles ou mobiles. Il s’agit à terme de faciliter le geste interventionnel, en maximisant la précision et la fiabilité des procédures, tout en minimisant le recours aux rayons X et au produit de contraste. Les travaux et résultats obtenus concernent : - L’étude d’approches de recalage permettant de fusionner des données 3D pré-opératoires décrivant les structures anatomiques et des données intra-opératoires de localisation 3D électromagnétique (positions d’un cathéter équipé d’un capteur magnétique en son extrémité). Dans le contexte du traitement des anévrismes aortiques abdominaux, deux méthodes de recalage ne nécessitant pas de marqueur externe et exploitant uniquement les trajectoires endovasculaires (avec hypothèse de correspondance totale ou partielle) ont été proposées. Les tests ont été réalisés sur fantôme physique. Bien que la précision de localisation des systèmes électromagnétiques soit encore limitée, ceux-ci pourraient être utilisés pour aider la navigation endovasculaire, comme par exemple, lors du cathétérisme d’artères collatérales. - L’élaboration d’une méthode de tracking des calcifications et de repères dans les séquences d’images fluoroscopiques, dans le contexte des procédures d’implantation endovasculaire de valve aortique (TAVI). Nous avons proposé une méthode de tracking par modèle d’apparence adaptatif (TMAA). L'approche a été évaluée sur 13 séquences fluoroscopiques dans le cadre des procédures TAVI valve native et 5 séquences fluoroscopiques dans le cadre des procédures TAVI valve-in-valve. Elle fournit une erreur de localisation moyenne inférieure à 1 mm et un temps de traitement de 32,23 ms/trame. L’évaluation de cette méthode et son application sur données patients ont permis de montrer la précision et la compatibilité du tracking avec une utilisation clinique. / This work is part of computer-assisted endovascular navigation. The aim of this thesis is to study and to propose new solutions for the localization and the tracking of moving endovascular devices within anatomical structures, which can be considered fixed or moving. The objective is to facilitate the endovascular intervention, by maximizing the accuracy and reliability of procedures, while minimizing the use of X-rays and contrast agents. The works concern : - The study of registration approaches to align pre-operative 3D data describing the anatomical structures and intra-operative 3D electromagnetic data (positions of a catheter equipped with a magnetic sensor at its tip). In the context of the treatment of abdominal aortic aneurysms (AAA), two fiducial-free registration methods that exploit only the endovascular trajectories (with total or partial correspondence hypothesis) have been proposed. The tests were performed on an AAA phantom. Although the localization accuracy of electromagnetic systems is still limited, these could be used to assist endovascular navigation (e.g., catheterization of collateral arteries). - The elaboration of a method to track calcifications and markers in fluoroscopic sequences, in the context of transcatheter aortic valve implantation (TAVI) procedures. We proposed a method of tracking by adaptive appearance model (TMAA). The approach was evaluated on 13 fluoroscopic sequences as part of TAVI native valve procedures and 5 fluoroscopic sequences as part of TAVI valve-in-valve procedures. The average localization error was less than 1 mm and the average processing time was 32.23 ms/frame. The evaluation of this method and its application on patient data has made it possible to show the precision and the compatibility of the tracking with a clinical use.
3

Apport de l'assistance par ordinateur lors de la pose d'endoprothèse aortique / Computer aided surgery in endovascular aortic procedures

Kaladji, Adrien 12 June 2015 (has links)
Les techniques endovasculaires, particulièrement pour l’aorte, sont en plein essor en chirurgie vasculaire. Ces techniques mini-invasives permettent de diminuer l’agression chirurgicale habituellement importante lors de la chirurgie conventionnelle. Les limites techniques sont repoussées à certaines localisations de l’aorte qui étaient il y a encore peu de temps inaccessibles aux endoprothèses. Le succès et l’efficience de ces interventions reposent en partie sur l'élaboration et la mise en œuvre de nouveaux outils d'aide à la décision. Ce travail entend contribuer à l’amélioration des procédures interventionnelles aortiques grâce à une meilleure exploitation de l’imagerie pré et peropératoire. Cette démarche s’inscrit dans le cadre plus général des Gestes Médico-Chirurgicaux Assistés par Ordinateur, dont les concepts sont revisités pour les transposer au domaine de la chirurgie endovasculaire. Trois axes sont développés afin de sécuriser et optimiser la pose d'endoprothèse. Le premier est focalisé sur l’analyse préopératoire du scanner (sizing) et montre les limites des outils de mesure actuels et évalue la précision d’un nouveau critère de mesure des longueurs de l’aorte (courbure externe). Le deuxième axe se positionne sur le versant peropératoire et montre la contribution de la réalité augmentée dans la pose d’une endoprothèse aortique. Le troisième axe s’intéresse au problème plus général des interventions sur les tissus mous et particulièrement aux déformations artérielles qui surviennent au cours des procédures interventionnelles qui mettent en défaut le recalage rigide lors de la fusion d’images. Nous présentons une approche originale basée sur un modèle numérique de prédiction des déformations qui utilise la simulation par éléments finis en y intégrant des paramètres géométriques et anatomo-mécaniques spécifique-patient extraits du scanner préopératoire. / The development of endovascular aortic procedures is growing. These mini-invasive techniques allow a reduction of surgical trauma, usually important in conventional open surgery. The technical limitations of endovascular repair are pushed to special aortic localizations which were in the past decade indication for open repair. Success and efficiency of such procedures are based on the development and the implementation of decision-making tools. This work aims to improve endovascular procedures thanks to a better utilization of pre and intraoperative imaging. This approach is in the line with the framework of computer-assisted surgery whose concepts are applied to vascular surgery. The optimization of endograft deployment is considered in three steps. The first part is dedicated to preoperative imaging analysis and shows the limits of the current sizing tools. The accuracy of a new measurement criterion is assessed (outer curvature length). The second part deals with intraoperative imaging and shows the contribution of augmented reality in endovascular aortic repair. In the last part, image guided surgery on soft tissues is addressed, especially the arterial deformations occurring during endovascular procedures which disprove rigid registration in fusion imaging. The use of finite element simulation to deal with this issue is presented. We report an original approach based on a predictive model of deformations using finite element simulation with geometrical and anatomo-mechanical patient specific parameters extracted from the preoperative CT-scan.

Page generated in 0.1166 seconds