• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 1
  • Tagged with
  • 12
  • 10
  • 8
  • 7
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Projeto estrutural de uma construção enterrada tipo bunker, destinada à instalação de equipamento acelerador linear de elétrons / Structural design of a bunker intended for installation of a linear accelerator of eletrons

Almeida, Patrícia de 29 May 2018 (has links)
A radioterapia externa ocupa lugar de destaque nos tratamentos de câncer. As construções das salas que abrigam os aceleradores lineares são custosas e este fator é limitante para que sejam instalados mais equipamentos. Faz-se necessária a pesquisa de opções construtivas com objetivo de redução de custos, mantendo-se a estabilidade estrutural e a barreira de proteção radiológica. Para a blindagem destas instalações podem ser empregados diversos materiais para a atenuação de radiação. O concreto armado é empregado em muitas destas instalações, seja pelo seu custo ou a prática construtiva no Brasil, face ao notório conhecimento deste material e abundância de matéria prima. Foram elaborados dois projetos estruturais de bunker em concreto armado. O projeto denominado bunker enterrado foi concebido com estrutura localizada no subsolo e dimensionado levando-se em conta inclusive os esforços decorrentes do solo adjacente às paredes. Foi adotada blindagem de concreto no teto. As demais faces da construção tem atenuação de radiação por solo compactado. O projeto do bunker não enterrado considerou a geometria de um projeto padrão do Ministério da Saúde e o acesso é pelo pavimento térreo. Em função da espessura necessária de blindagem, foi projetada uma estrutura com dimensões que contemplam a barreira no teto e paredes. Os resultados obtidos neste estudo foram satisfatórios quanto aos dois modelos estruturais propostos, com vantagens e desvantagens. Foi mostrada a diferença de custos entre uma estrutura de edificação enterrada e outra não enterrada. A estrutura enterrada mostrou-se mais viável, pois aproveita o solo compactado adjacente para atenuação da radiação. / External radiotherapy occupies a prominent place in cancer treatments. The constructions of the rooms that shelter the linear accelerators are costly and this is a limiting factor to have more equipment installed. It is necessary to research construction options with the objective of reducing costs, maintaining the structural stability and the radiological protection barrier. For the shielding of these installations, various materials can be used for the attenuation of radiation. Reinforced concrete is used in many of these facilities, either for its cost or the constructive practice in Brazil, due to the know-how of this material and abundance of raw material. Two structural bunker structural projects were developed. The buried bunker project was designed with a structure located underground and dimensioned taking into account including the efforts from the soil adjacent to the walls. Concrete shield was used in the ceiling. The other faces of the construction have radiation attenuation by compacted soil. The not buried bunker project considered the geometry of a standard design of the Health Ministry and its access is by the ground floor. Due to the required thickness of shielding, a structure with dimensions that contemplate the barrier in the ceiling and walls was designed. The results obtained in this study were satisfactory, regarding the two proposed structural models, taking in consideration advantages and disadvantages. The difference in costs of a buried structure and not buried one was provided. The buried structure proved to be more viable, since it utilizes adjacent compacted soil to attenuate the radiation.
2

Projeto estrutural de uma construção enterrada tipo bunker, destinada à instalação de equipamento acelerador linear de elétrons / Structural design of a bunker intended for installation of a linear accelerator of eletrons

Patrícia de Almeida 29 May 2018 (has links)
A radioterapia externa ocupa lugar de destaque nos tratamentos de câncer. As construções das salas que abrigam os aceleradores lineares são custosas e este fator é limitante para que sejam instalados mais equipamentos. Faz-se necessária a pesquisa de opções construtivas com objetivo de redução de custos, mantendo-se a estabilidade estrutural e a barreira de proteção radiológica. Para a blindagem destas instalações podem ser empregados diversos materiais para a atenuação de radiação. O concreto armado é empregado em muitas destas instalações, seja pelo seu custo ou a prática construtiva no Brasil, face ao notório conhecimento deste material e abundância de matéria prima. Foram elaborados dois projetos estruturais de bunker em concreto armado. O projeto denominado bunker enterrado foi concebido com estrutura localizada no subsolo e dimensionado levando-se em conta inclusive os esforços decorrentes do solo adjacente às paredes. Foi adotada blindagem de concreto no teto. As demais faces da construção tem atenuação de radiação por solo compactado. O projeto do bunker não enterrado considerou a geometria de um projeto padrão do Ministério da Saúde e o acesso é pelo pavimento térreo. Em função da espessura necessária de blindagem, foi projetada uma estrutura com dimensões que contemplam a barreira no teto e paredes. Os resultados obtidos neste estudo foram satisfatórios quanto aos dois modelos estruturais propostos, com vantagens e desvantagens. Foi mostrada a diferença de custos entre uma estrutura de edificação enterrada e outra não enterrada. A estrutura enterrada mostrou-se mais viável, pois aproveita o solo compactado adjacente para atenuação da radiação. / External radiotherapy occupies a prominent place in cancer treatments. The constructions of the rooms that shelter the linear accelerators are costly and this is a limiting factor to have more equipment installed. It is necessary to research construction options with the objective of reducing costs, maintaining the structural stability and the radiological protection barrier. For the shielding of these installations, various materials can be used for the attenuation of radiation. Reinforced concrete is used in many of these facilities, either for its cost or the constructive practice in Brazil, due to the know-how of this material and abundance of raw material. Two structural bunker structural projects were developed. The buried bunker project was designed with a structure located underground and dimensioned taking into account including the efforts from the soil adjacent to the walls. Concrete shield was used in the ceiling. The other faces of the construction have radiation attenuation by compacted soil. The not buried bunker project considered the geometry of a standard design of the Health Ministry and its access is by the ground floor. Due to the required thickness of shielding, a structure with dimensions that contemplate the barrier in the ceiling and walls was designed. The results obtained in this study were satisfactory, regarding the two proposed structural models, taking in consideration advantages and disadvantages. The difference in costs of a buried structure and not buried one was provided. The buried structure proved to be more viable, since it utilizes adjacent compacted soil to attenuate the radiation.
3

Novo equipamento para a avaliação do comportamento mecânico de dutos enterrados e análise concomitante das deformações no solo via correlação de imagens digitais / New apparatus for mechanical behaviour evaluation of buried pipes with concomitant soil deformation analysis using digital image correlation

Franco, Yara Barbosa 10 April 2017 (has links)
O presente trabalho tem por objetivo desenvolver um aparato experimental para estudar, em modelo físico de escala reduzida, o comportamento mecânico de um duto enterrado submetido a variações do estado de tensões da massa de solo circundante e a um potencial movimento de massa gravitacional, com avaliação concomitante das deformações desenvolvidas no solo por meio da técnica de correlação de imagens digitais. A alteração do estado de tensão no maciço foi feita por meio da aplicação de incrementos de inclinação ao modelo. Foram realizados ensaios com o duto nas posições transversal e longitudinal no interior da caixa de ensaios, enterrado em areia pura e seca, com razão entre altura de cobertura e diâmetro do duto de 3,55. A compacidade do maciço, controlada por meio da utilização da técnica de chuva de areia, foi avaliada nas situações densa (D = 111,5 %) e fofa (Dr = 58,2%). O comportamento mecânico do duto foi avaliado por meio de instrumentação para medição da deformação específica e deflexão da parede, sendo verificado efeito de flexão lateral no duto disposto na transversal, com maiores deformações observadas na situação de maciço fofo. Para o duto disposto na longitudinal, maiores deformações específicas foram observadas para a seção instrumentada central na situação de maciço denso, contudo verificou-se a necessidade de realização de ensaios adicionais para elucidação dos resultados, em termos da interação solo/tubo ao longo do comprimento do elemento. Para a utilização da técnica de correlação de imagens digitais, as imagens foram adquiridas em um ambiente com iluminação padronizada e resolução de partícula igual a 4. A qualidade da textura da imagem foi garantida por meio da preparação de material com adição de 20% de areia colorida. O refinamento da malha de análise, avaliado por meio da alteração do tamanho dos subsets e espaçamento entre subsets, não exerceu grande influência nos campos de deslocamentos obtidos, porém maiores refinamentos permitiram extrair observações mais detalhadas do campo de deformações. A utilização da técnica permitiu ainda avaliar a evolução dos vetores de deslocamento ao longo das etapas de inclinação e a influência do duto enterrado, na posição transversal, nos deslocamentos das partículas de solo circundante. / The present work aims the development of an experimental apparatus to study the behavior of a buried pipe under different soil stress states and potential landslides in a small-scale physical model. Digital image correlation technique is also used to evaluate soil deformation. A controlled slope increment squeme were responsible for soil stress state changes. The tests were performed with the model pipe buried in pure dry sand with a buried depth ratio of 3.55. A series of four tests involving two pipe configurations inside the test box (transversal and longitudinal) and two relative density (111.5% and 58.2%) was conducted. Soil density was controlled by pluviation method. The model pipe was instrumented in order to evaluate its behavior in terms of linear strain and deflection of the pipe wall. For the transversely disposed pipe, it was observed lateral bending effect and larger strains when buried in loose sand. For the longitudinally diposed pipe, the largest strains occurred in the pipe central cross section and in the tests conducted in dense sand. Nevertheless, additional testing is needed to better clarify the results, in terms of soil/pipe interaction along the pipe length. Daily digital images were acquired under standardized conditions of illumination for the use of digital image correlation technique. The particle/pixel size ratio was set equal to 4. Image texture quality was improved by adding 20% colored sand to the material used in the investigation. The level of refinement of the analysis mesh, evaluated by varying the subset size and the spacing of subsets, did not shown significant effect in the displacement fields. However, finer meshes allowed more detailed observations in the engineering shear strain fields obtained. Additionally, the digital image correlation technique allowed the evaluation of the displacement vectors evolution along the different slope stages considered. Moreover, this technique also captured the effect of the transversely disposed pipe on surrounding soil particles displacements.
4

An?lise num?rica de dutos enterrados sujeitos a eleva??o e recalque localizado / Numerical analysis of buried pipes subjected to localized elevation or loss of support

Moraes, Lucas da Silva 03 November 2014 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-01-05T16:51:31Z No. of bitstreams: 1 LucasDaSilvaMoraes_DISSERT.pdf: 5039451 bytes, checksum: fb1fce3fc0cb32b8b90727afb4b2b99f (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-01-08T17:38:57Z (GMT) No. of bitstreams: 1 LucasDaSilvaMoraes_DISSERT.pdf: 5039451 bytes, checksum: fb1fce3fc0cb32b8b90727afb4b2b99f (MD5) / Made available in DSpace on 2016-01-08T17:38:57Z (GMT). No. of bitstreams: 1 LucasDaSilvaMoraes_DISSERT.pdf: 5039451 bytes, checksum: fb1fce3fc0cb32b8b90727afb4b2b99f (MD5) Previous issue date: 2014-11-03 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Os problemas relacionados ?s intera??es longitudinais em dutos enterrados se caracterizam como tridimensionais, podendo gerar in?meras situa??es particulares no comportamento solo-duto. Em rela??o ao avan?o nas pesquisas na ?rea de dutos enterrados, ainda ? pequena a aten??o ao tema ao longo das ?ltimas d?cadas, visto que a maioria dos trabalhos simplifica o problema analisado considerando-o em deforma??o plana. O presente trabalho tem como objetivo apresentar um estudo sobre o comportamento de dutos enterrados sujeitos a eleva??o ou recalque localizado, atrav?s de simula??es num?ricas em tr?s dimens?es. Como ferramenta num?rica foi utilizado o aplicativo computacional Plaxis 3D, o qual utiliza o m?todo dos elementos finitos. Foram avaliados aspectos espec?ficos da modelagem num?rica e realizadas an?lises param?tricas em que se investigaram os efeitos do arqueamento do solo de forma tridimensional. As principais vari?veis investigadas foram: densidade relativa do solo, deslocamento da zona de eleva??o ou recalque, faixa da zona elevada, altura de recobrimento e a rela??o di?metro/espessura do duto. As simula??es foram realizadas em duas etapas distintas, sendo na primeira feita a valida??o das an?lises num?ricas atrav?s dos modelos f?sicos de Costa (2005). Em seguida, foram realizadas an?lises num?ricas de um oleoduto em um caso espec?fico de obra, considerando o mesmo submetido ? eleva??o localizada. Os resultados obtidos permitiram a valida??o do modelo num?rico face aos resultados dos experimentos de Costa (2005), a iv avalia??o detalhada da redistribui??o das tens?es no maci?o e das deflex?es ao longo do duto, bem como a avalia??o do desenvolvimento do arqueamento no solo. Foi verificada a redu??o das tens?es no maci?o e nas deflex?es no duto ao se diminuir a altura de recobrimento do duto nas regi?es que possam deflagrar a eleva??o localizada. Tamb?m foi verificado que os esfor?os longitudinais foram superiores aos circunferenciais para situa??o analisada, inclusive ultrapassando as tens?es e deflex?es admiss?veis. Al?m disso, foram observados os benef?cios das t?cnicas de minimiza??o das tens?es como a falsa trincheira, ber?o compress?vel e a combina??o de ambas aplicadas ao oleoduto simulado / Problems associated to longitudinal interactions in buried pipelines are characterized as three-dimensional and can lead to different soil-pipe issues. Despite the progress achieved in research on buried pipelines, little attention has been given to the three-dimensional nature of the problem throughout the last decades. Most of researches simplify the problem by considering it in plane strain condition. This dissertation aims to present a study on the behavior of buried pipelines under local settlement or elevation, using three-dimensional simulations. Finite element code Plaxis 3D was used for the simulations. Particular aspects of the numerical modeling were evaluated and parametric analyzes were performed, was investigated the effects of soil arching in three-dimensional form. The main variables investigated were as follows: relative density, displacement of the elevation or settlement zone, elevated zone size, height of soil cover and pipe diameter/thickness ratio. The simulations were performed in two stages. The first stage was involved the validation of the numerical analysis using the physical models put forward by Costa (2005). In the second stage, numerical analyzes of a full-scale pipeline subjected to a localized elevation were performed. The obtained results allowed a detailed evaluation of the redistribution of stresses in the soil mass and the deflections along the pipe. It was observed the reduction of stresses in the soil mass and pipe deflections when the height of soil cover was decreased on regions of the pipe subjected to elevation. It was also shown for the analyzed situation that longitudinal thrusts were higher than vi circumferential trusts and exceeded the allowable stresses and deflections. Furthermore, the benefits of minimizing stress with technical as the false trench, compressible cradle and a combination of both applied to the simulated pipeline were verified
5

Novo equipamento para a avaliação do comportamento mecânico de dutos enterrados e análise concomitante das deformações no solo via correlação de imagens digitais / New apparatus for mechanical behaviour evaluation of buried pipes with concomitant soil deformation analysis using digital image correlation

Yara Barbosa Franco 10 April 2017 (has links)
O presente trabalho tem por objetivo desenvolver um aparato experimental para estudar, em modelo físico de escala reduzida, o comportamento mecânico de um duto enterrado submetido a variações do estado de tensões da massa de solo circundante e a um potencial movimento de massa gravitacional, com avaliação concomitante das deformações desenvolvidas no solo por meio da técnica de correlação de imagens digitais. A alteração do estado de tensão no maciço foi feita por meio da aplicação de incrementos de inclinação ao modelo. Foram realizados ensaios com o duto nas posições transversal e longitudinal no interior da caixa de ensaios, enterrado em areia pura e seca, com razão entre altura de cobertura e diâmetro do duto de 3,55. A compacidade do maciço, controlada por meio da utilização da técnica de chuva de areia, foi avaliada nas situações densa (D = 111,5 %) e fofa (Dr = 58,2%). O comportamento mecânico do duto foi avaliado por meio de instrumentação para medição da deformação específica e deflexão da parede, sendo verificado efeito de flexão lateral no duto disposto na transversal, com maiores deformações observadas na situação de maciço fofo. Para o duto disposto na longitudinal, maiores deformações específicas foram observadas para a seção instrumentada central na situação de maciço denso, contudo verificou-se a necessidade de realização de ensaios adicionais para elucidação dos resultados, em termos da interação solo/tubo ao longo do comprimento do elemento. Para a utilização da técnica de correlação de imagens digitais, as imagens foram adquiridas em um ambiente com iluminação padronizada e resolução de partícula igual a 4. A qualidade da textura da imagem foi garantida por meio da preparação de material com adição de 20% de areia colorida. O refinamento da malha de análise, avaliado por meio da alteração do tamanho dos subsets e espaçamento entre subsets, não exerceu grande influência nos campos de deslocamentos obtidos, porém maiores refinamentos permitiram extrair observações mais detalhadas do campo de deformações. A utilização da técnica permitiu ainda avaliar a evolução dos vetores de deslocamento ao longo das etapas de inclinação e a influência do duto enterrado, na posição transversal, nos deslocamentos das partículas de solo circundante. / The present work aims the development of an experimental apparatus to study the behavior of a buried pipe under different soil stress states and potential landslides in a small-scale physical model. Digital image correlation technique is also used to evaluate soil deformation. A controlled slope increment squeme were responsible for soil stress state changes. The tests were performed with the model pipe buried in pure dry sand with a buried depth ratio of 3.55. A series of four tests involving two pipe configurations inside the test box (transversal and longitudinal) and two relative density (111.5% and 58.2%) was conducted. Soil density was controlled by pluviation method. The model pipe was instrumented in order to evaluate its behavior in terms of linear strain and deflection of the pipe wall. For the transversely disposed pipe, it was observed lateral bending effect and larger strains when buried in loose sand. For the longitudinally diposed pipe, the largest strains occurred in the pipe central cross section and in the tests conducted in dense sand. Nevertheless, additional testing is needed to better clarify the results, in terms of soil/pipe interaction along the pipe length. Daily digital images were acquired under standardized conditions of illumination for the use of digital image correlation technique. The particle/pixel size ratio was set equal to 4. Image texture quality was improved by adding 20% colored sand to the material used in the investigation. The level of refinement of the analysis mesh, evaluated by varying the subset size and the spacing of subsets, did not shown significant effect in the displacement fields. However, finer meshes allowed more detailed observations in the engineering shear strain fields obtained. Additionally, the digital image correlation technique allowed the evaluation of the displacement vectors evolution along the different slope stages considered. Moreover, this technique also captured the effect of the transversely disposed pipe on surrounding soil particles displacements.
6

Análisis y modelado de una instalación geotérmica para climatización de un conjunto de oficinas

Ruiz Calvo, Félix 01 September 2015 (has links)
[EN] The use of ground source heat pump systems has spread during the last years. When designing, studying and optimizing this kind of systems, models are used, more or less detailed, which allow predicting the behavior of the system within the application minimum requirements. The installation studied in this thesis is located at Universitat Politècnica de València. In this report, the development of a global detailed model of this installation is presented, along with its validation using experimental data. The main objective is to obtain a model able to correctly predict the dynamic and static behavior of the system, both on a short- and a long-term basis. Prior to the model development, it is necessary to study the performance of the experimental system. Besides the system description, also an analysis of the performance of the installation during five years (from 2008 to 2012) is carried out. For this analysis, some characteristic parameters of the system behavior have been taken into account which are obtained from the experimental measurements corresponding to the typical operation of the installation, such as the average water temperatures, the building's thermal load, the partial load ratio, or the daily and seasonal performance factors. Since the study and analysis of these parameters is one of the aims of the present work, the calculation procedure and the formulas used for their determination are detailed, in some cases involving a highly complex raw data processing. From the short-term evolution study of the variables that represent the performance of the installation, the main characteristics of the system dynamic behavior are identified. The model will intend to reproduce these characteristics. On the other hand, the long-term performance parameters are studied as monthly averages. In this analysis, the characteristic trends of the system long-term performance are identified. The model should be able to also reproduce these trends. The global model has been developed using the TRNSYS software. A progressive incorporation strategy has been followed. At each step, the correct adjustment of the model is ensured by validating it with experimental data, allowing the identification of the influence that each component has on the final results. When including the ground source heat exchanger to the global model, it is evident the need for a new model for this component that can correctly reproduce both the dynamic and static response of the water temperature at the end of the pipes of the heat exchanger. Therefore, as a final step, a new ground source heat exchanger model has been developed, based on combining two different models: the g-function model in order to account for the long-term behavior of the ground temperature, and the B2G model, specifically developed for this application. The ground source heat exchanger model has been validated against experimental data from two different installations and, finally, it has been included into the global model of the system. The system global model developed has proved to be able to precisely reproduce the experimental results for the system performance, both on a short- and long-term basis, even after including the modifications that have occurred on the experimental installation along the years. Therefore, the model will be a useful tool for the development of future optimization strategies, together with the corresponding control algorithms. / [ES] En los últimos años se han extendido las instalaciones de climatización con bomba de calor acoplada al terreno. En el diseño, el estudio y la optimización de este tipo de instalaciones se utilizan modelos con mayor o menor nivel de detalle que permiten predecir el comportamiento del sistema dentro de unos requerimientos mínimos específicos de la aplicación en concreto. La instalación objeto de estudio de la presente tesis se encuentra situada en la Universitat Politècnica de València. A lo largo de esta memoria se presenta el trabajo de desarrollo de un modelo global detallado de esta instalación, así como su validación con datos experimentales. El objetivo perseguido es el de obtener un modelo capaz de predecir correctamente el comportamiento dinámico y estático de la instalación, tanto a corto como a largo plazo. Previo al desarrollo del modelo en sí, es necesario estudiar el comportamiento de la instalación experimental. Además de una descripción detallada del sistema, se realiza un análisis de su funcionamiento a lo largo de varios años (del año 2008 al 2012). Para este análisis se han tenido en cuenta diversos parámetros característicos del comportamiento energético del sistema, obtenidos a partir de las medidas experimentales registradas en el funcionamiento habitual de la instalación. Uno de los objetivos de esta tesis es precisamente el estudio y análisis de estos parámetros, por lo que se han detallado las fórmulas y el procedimiento de cálculo utilizado para su obtención, que en algunos casos puede presentar una gran complejidad en el manejo y tratamiento de los datos experimentales. A partir del estudio de la evolución a corto plazo de las variables representativas del funcionamiento de la instalación, se identifican las principales características del comportamiento dinámico del sistema, que se intentarán reproducir con el modelo desarrollado. Por su parte, el estudio de los parámetros característicos del funcionamiento a lo largo de varios años se realiza teniendo en cuenta los valores correspondientes a promedios mensuales. En este análisis se identifican también las tendencias características del comportamiento del sistema a largo plazo, que posteriormente el modelo global de la instalación deberá ser capaz de reproducir. El modelo global se ha desarrollado utilizando la herramienta TRNSYS. Para ello se ha seguido una estrategia de incorporación progresiva de componentes. En cada paso se asegura un correcto ajuste del modelo mediante su validación con datos experimentales, lo cual permite identificar y aislar los efectos de cada componente sobre los resultados finales. Al incluir el intercambiador enterrado en el modelo global, queda patente la necesidad de un nuevo modelo de intercambiador enterrado capaz de reproducir el comportamiento tanto dinámico como estático de la temperatura del agua a la salida del mismo. Así pues, como último punto de la tesis, se ha desarrollado un modelo de intercambiador enterrado, basado en la combinación de dos modelos distintos: el modelo \emph{g-function} para tener en cuenta el comportamiento a largo plazo de la temperatura del terreno y el modelo B2G, desarrollado específicamente para esta aplicación. Este modelo de intercambiador enterrado ha sido debidamente validado con datos experimentales pertenecientes a dos intercambiadores distintos y, posteriormente, se ha incluido en el modelo global de la instalación. El modelo global de la instalación desarrollado de esta forma consigue reproducir con precisión los resultados experimentales del funcionamiento del sistema tanto a corto como a largo plazo, incluso después de aplicar las mismas modificaciones que se han ido aplicando a la instalación experimental a lo largo de los años, y resulta ser, por tanto, una herramienta útil para el desarrollo de futuras estrategias de optimización energética, junto con los algoritmos de control correspondientes. / [CA] Als últims anys s'han estès les instal·lacions de climatització amb bomba de calor acoplada al terreny. En el disseny, l'estudi i la optimització d'aquest tipus d'instal·lacions s'utilitzen models amb major o menor nivell de detall que permeten predir el comportament del sistema dins uns requeriments mínims específics de l'aplicació en concret. La instal·lació objecte d'estudi de la present tesi es troba a la Universitat Politècnica de València. Al llarg d'aquesta memòria es presenta el treball de desenvolupament d'un model global detallat d'aquesta instal·lació, així com la seua validació amb dades experimentals. L'objectiu perseguit es el d'obtindre un model capaç de predir correctament el comportament dinàmic i estàtic de la instal·lació, tant a curt com a llarg termini. Prèviament al desenvolupament del model en sí, es necessari estudiar el comportament de la instal·lació experimental. A més de una descripció detallada del sistema, es realitza un anàlisi del seu funcionament al llarg de diversos anys (de l'any 2008 al 2012). Per a aquest anàlisi s'han considerat diversos paràmetres característics del comportament energètic del sistema, obtinguts a partir de les mesures experimentals registrades en el funcionament habitual de la instal·lació, com per exemple les temperatures mitjanes de l'aigua en diversos punts del sistema, la demanda tèrmica de l'edifici, el factor de càrrega parcial o els factors de rendiment diari i estacional. Un dels objectius d'aquesta tesi és precisament l'estudi i anàlisi d'aquestos paràmetres, pel que s'han detallat les fórmules i el procediment de càlcul emprat per a la seua obtenció, que en alguns casos pot presentar una gran complexitat en el tractament de les dades experimentals. A partir de l'estudi de la evolució a curt termini de les variables representatives del funcionament de la instal·lació, s'identifiquen les principals característiques del comportament dinàmic del sistema, que s'intentaran reproduir amb el model desenvolupat. Per altra banda, l'estudi dels paràmetres característics del funcionament al llarg de diversos anys es realitza tenint en compte els valors corresponents a promitjos mensuals. En aquest anàlisi s'identifiquen també les tendències característiques del comportament del sistema a llarg termini, que posteriorment el model global de la instal·lació deurà ser capaç de reproduir. El model global s'ha desenvolupat utilitzant la ferramenta TRNSYS. Amb aquest fi s'ha seguit una estratègia d'incorporació progressiva de components. A cada pas s'assegura un correcte ajust del model mitjançant la validació amb dades experimentals, la qual cosa permet identificar i aïllar els efectes de cada component sobre els resultats finals. Al incloure l'intercanviador soterrat en el model global, queda de manifest la necessitat d'un nou model d'intercanviador soterrat capaç de reproduir el comportament tant dinàmic com estàtic de la temperatura de l'aigua a la eixida del tub. Així, com últim punt de la tesi, s'ha desenvolupat un model d'intercanviador soterrat, basat en la combinació de dos models distints: el model \emph{g-function} per a tindre en comte el comportament a llarg termini de la temperatura del terreny i el model B2G, desenvolupat específicament per a aquesta aplicació. Aquest model d'intercanviador soterrat ha sigut degudament validat amb dades experimental de dos intercanviadors distints i, posteriorment, s'ha inclòs en el model global de la instal·lació. El model global de la instal·lació desenvolupat d'aquesta manera aconsegueix reproduir amb precisió els resultats experimentals del funcionament del sistema tant a curt com a llarg termini, inclús després d'aplicar-hi les mateixes modificacions que s'han anat aplicant a la instal·lació experimental al llarg dels anys, y resulta ser, per tant, una ferramenta útil per al desenvolupament de futures estratègies d'optimització energèti / Ruiz Calvo, F. (2015). Análisis y modelado de una instalación geotérmica para climatización de un conjunto de oficinas [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/54134
7

Modelagem física de condutos enterrados sujeitos a perda de apoio ou elevação localizada / Physical modeling of buried pipes subjected to localized loss of support or elevation

Costa, Yuri Daniel Jatobá 24 May 2005 (has links)
Este trabalho apresenta um estudo experimental sobre o comportamento de dutos enterrados sofrendo perda de apoio ou elevação em uma determinada região ao longo do comprimento. Foram realizados ensaios com modelos físicos compostos por um maciço de areia pura contendo um tubo repousando sobre um alçapão localizado no centro do vão. A pesquisa envolveu dois programas experimentais distintos. O primeiro foi desenvolvido na Escola de Engenharia de São Carlos/USP e contou com o desenvolvimento e a construção de um equipamento de ensaios possuindo um sistema de alçapão. Os modelos eram dotados de instrumental capaz de medir as deflexões e as deformações específicas ao longo do duto, além das tensões totais no maciço de solo circundante e na base do equipamento. O segundo programa experimental foi conduzido na Universidade do Colorado em Boulder, EUA, e envolveu ensaios em centrífuga. Essa fase da pesquisa teve por finalidade realizar uma investigação visual dos mecanismos de ruptura do sistema composto pelo solo e pelo duto sujeito à perda de apoio. Ambas as etapas do trabalho contaram com a execução de testes com modelos sem tubo. Os ensaios realizados revelaram aspectos importantes do problema investigado. A movimentação ativa ou passiva do alçapão exerceu uma forte influência na redistribuição das tensões no maciço de solo exterior à estrutura, a qual abrangeu distâncias horizontais superiores a 5 B e verticais superiores a 4 B. Após a perda de apoio ou a elevação, o topo, a base e as demais partes do conduto assumiram perfis de deflexão distintos ao longo do comprimento, os quais foram consideravelmente influenciados pela densidade relativa do solo e pela sobrecarga aplicada. A movimentação ativa do alçapão revelou ainda padrões de ruptura incluindo localizações de deformação propagando-se para a região do maciço de solo fora do alçapão / This thesis presents an experimental study on the behavior of buried pipes undergoing a loss of support or elevation in a localized region along its length. Tests with physical models comprising a pure dry sand and a tube resting on a rigid trapdoor base located at the center of its length were performed. The research included two distinct testing programs. The first testing program was carried out at the School of Engineering of Sao Carlos/USP, and included the construction of a laboratory facility containing a trapdoor system. The models were equipped with devices for measuring deflections and strains in the pipe, and total stresses in the soil mass and in the lower boundary of the model. The second phase of this investigation was conducted at the University of Colorado at Boulder, USA, and involved centrifuge testing. The main goal of this part of the research was to assess the failure mechanisms that take place when the pipe experiences loss of support. Models without the pipe were also tested in both phases. Important aspects of the soil-structure interaction were verified with the testing programs carried out in this study. A strong influence on the stress redistribution within the soil mass in the vicinity of the structure was achieved after the active or passive conditions were established, encompassing horizontal distances greater than 5 B and vertical distances greater than 4 B. The crown, the base, and the other parts of the pipe assumed distinct deflection profiles after the loss of support or elevation, which were strongly influenced by the relative density of the surrounding soil and by the surficial applied surcharge. The imposed downward boundary movement included the formation of shear bands initiating at the edge of the void and propagating towards the soil mass in the vicinity of the trapdoor
8

Modelagem física de condutos enterrados sujeitos a perda de apoio ou elevação localizada / Physical modeling of buried pipes subjected to localized loss of support or elevation

Yuri Daniel Jatobá Costa 24 May 2005 (has links)
Este trabalho apresenta um estudo experimental sobre o comportamento de dutos enterrados sofrendo perda de apoio ou elevação em uma determinada região ao longo do comprimento. Foram realizados ensaios com modelos físicos compostos por um maciço de areia pura contendo um tubo repousando sobre um alçapão localizado no centro do vão. A pesquisa envolveu dois programas experimentais distintos. O primeiro foi desenvolvido na Escola de Engenharia de São Carlos/USP e contou com o desenvolvimento e a construção de um equipamento de ensaios possuindo um sistema de alçapão. Os modelos eram dotados de instrumental capaz de medir as deflexões e as deformações específicas ao longo do duto, além das tensões totais no maciço de solo circundante e na base do equipamento. O segundo programa experimental foi conduzido na Universidade do Colorado em Boulder, EUA, e envolveu ensaios em centrífuga. Essa fase da pesquisa teve por finalidade realizar uma investigação visual dos mecanismos de ruptura do sistema composto pelo solo e pelo duto sujeito à perda de apoio. Ambas as etapas do trabalho contaram com a execução de testes com modelos sem tubo. Os ensaios realizados revelaram aspectos importantes do problema investigado. A movimentação ativa ou passiva do alçapão exerceu uma forte influência na redistribuição das tensões no maciço de solo exterior à estrutura, a qual abrangeu distâncias horizontais superiores a 5 B e verticais superiores a 4 B. Após a perda de apoio ou a elevação, o topo, a base e as demais partes do conduto assumiram perfis de deflexão distintos ao longo do comprimento, os quais foram consideravelmente influenciados pela densidade relativa do solo e pela sobrecarga aplicada. A movimentação ativa do alçapão revelou ainda padrões de ruptura incluindo localizações de deformação propagando-se para a região do maciço de solo fora do alçapão / This thesis presents an experimental study on the behavior of buried pipes undergoing a loss of support or elevation in a localized region along its length. Tests with physical models comprising a pure dry sand and a tube resting on a rigid trapdoor base located at the center of its length were performed. The research included two distinct testing programs. The first testing program was carried out at the School of Engineering of Sao Carlos/USP, and included the construction of a laboratory facility containing a trapdoor system. The models were equipped with devices for measuring deflections and strains in the pipe, and total stresses in the soil mass and in the lower boundary of the model. The second phase of this investigation was conducted at the University of Colorado at Boulder, USA, and involved centrifuge testing. The main goal of this part of the research was to assess the failure mechanisms that take place when the pipe experiences loss of support. Models without the pipe were also tested in both phases. Important aspects of the soil-structure interaction were verified with the testing programs carried out in this study. A strong influence on the stress redistribution within the soil mass in the vicinity of the structure was achieved after the active or passive conditions were established, encompassing horizontal distances greater than 5 B and vertical distances greater than 4 B. The crown, the base, and the other parts of the pipe assumed distinct deflection profiles after the loss of support or elevation, which were strongly influenced by the relative density of the surrounding soil and by the surficial applied surcharge. The imposed downward boundary movement included the formation of shear bands initiating at the edge of the void and propagating towards the soil mass in the vicinity of the trapdoor
9

[pt] ANÁLISE DE PROBLEMAS TRIDIMENSIONAIS SOLO-ESTRUTURA PELO MÉTODO DOS ELEMENTOS FINITOS NO DOMÍNIO DE FOURIER / [es] ANÁLISIS DE PROBLEMAS TRIDIMENSIONALES SUELO-EXTRUCTURA POR EL MÉTODO DE LOS ELEMENTOS FINITOS EN EL DOMINIO DE FOURIER / [en] THREE-DIMENSIONAL ANALYSIS OF SOIL-STRUCTURE PROBLEMS USING THE FINITE ELEMENT METHOD IN THE FOURIER DOMAIN

JANAINA VEIGA CARVALHO 03 August 2001 (has links)
[pt] Este trabalho estuda problemas geotécnicos e de interação solo-estrutura utilizando o método dos elementos finitos acoplado com a transformada de Fourier. Pela aplicação da transformada de Fourier, as equações diferenciais que governam o problema elástico linear, com as correspondentes condições de contorno, são reescritas no plano de Fourier, permitindo que um problema de natureza tridimensional possa ser numericamente analisado por uma discretização bidimensional. Esta técnica foi empregada neste trabalho para certos problemas de engenharia, como dutovias, túneis e fundações tipo radier, onde a geometria e os parâmetros dos materiais mantêm-se constantes ao longo do eixo longitudinal do corpo, porém admitindo-se variações espaciais no carregamento imposto ao sistema, gerando , assim, um estado tridimensional de tensões. Alguns elementos de interface, com formulação publicada na literatura, foram também considerados na implementação computacional, visto que em problemas de interação solo- estrutura o comportamento do sistema é bastante influenciado pelas propriedades e características mecânicas do solo imediatamente vizinho à estrutura. Os exemplos numéricos apresentados são comparados, sempre que possível, com os resultados obtidos por outra solução analítica ou numérica, procurando discutir as vantagens e limitações do acoplamento da transformada de Fourier com o método dos elementos finitos para a análise de determinada classe de problemas geotécnicos tridimensionais. / [en] In this work some geotechnical and soil-structure interaction problems are studied using the finite element method coupled with a Fourier transform technique. For linear elastic problems, Fourier transforms are applied to the governing field equations, thus enabling that some specific tridimensional problems can be analyzed using a 2D finite element mesh. In conventional finite element applications, a 3D discretization is usually required, but difficulties associated with the preparation of the finite element mesh and the involved computational efforts prevent, in general, the use of a true 3D model. The integral transform method is used in this research for the analysis of some very common problems in geotechnical engineering, such as piping systems, raft foundations and tunnels, where the geometry and the soil profile may be considered constant along a coordinate direction. The applied loading, however, can assume any possible surface distribution, which does not allow to treat the problem under the plane strain assumptions. Some special finite elements presented in the literature, called joint or interface elements, are also incorporated into the finite element computational program written in this research, given that for soil-structure interaction problems the material behavior at the common interface may greatly affect the entire system results. Some numerical examples are presented, and their numerical results are compared, whenever possible, with other solutions obtained using analytical or other numerical technique. Advantages and limitations of the integral transform method to solve tridimensional geomechanics problems are also discussed in this work. / [es] Este trabajo estudia problemas geotécnicos y de interacción suelo-extructura utilizando el método de los elementos finitos acoplado con la transformada de Fourier. Por la aplicación de la transformada de Fourier, las ecuaciones diferenciales que goviernan el problema elástico lineal, con las correspondentes condiciones de contorno, son reescritas en el plano de Fourier, permitiendo que un problema de naturaleza tridimensional pueda ser numericamente analizado por una discretización bidimensional. Esta técnica fue utilizada en este trabajo para ciertos problemas de Ingeniería, como canales, túneles y fundaciones tipo radier, donde la geometría y los parámetros de los materiales se mantienen constantes a lo largo del eje longitudinal del cuerpo, aunque se admiten variaciones espaciales en la carga impuesta al sistema, generando , así, un estado tridimensional de tensiones. En la implementación computacional fueron considerados algunos elementos de la interfaz, con formulación publicada en la literatura, ya que en problemas de interacción suelo-extructura, el comportamiento del sistema está bastante influenciado por las propiedades y características mecánicas del suelo imediatamente vecino a la extructura. Los ejemplos numéricos presentados se compararon, siempre que fue posible, con los resultados obtenidos por otra solución analítica o numérica, discutiendo las ventajas y limitaciones del acoplamiento de la transformada de Fourier con el método de los elementos finitos para el análisis de determinada clase de problemas geotécnicos tridimensionales.
10

[en] DESIGN OF BURIED PIPELINES CONSIDERING THE RECIPROCAL SOIL-STRUCTURE INTERACTION / [pt] ESTUDO DE DUTOS ENTERRADOS CONSIDERANDO A INTERAÇÃO SOLO-ESTRUTURA

NELLY PIEDAD RUBIO RUBIO 18 February 2016 (has links)
[pt] Esta pesquisa tem como objetivo o desenvolvimento de uma metodologia com base no método de elementos finitos para o estudo do problema de contato com atrito que surge na interação solo-duto no comportamento de dutos enterrados. O tratamento das restrições de contato e a incorporação da lei do atrito (tipo Coulomb) é feita através do Método da Penalidade, tomando como referência o trabalho de Laursen e Simo (2002), onde as restrições de contato são impostas de maneira aproximada com o uso de parâmetros de penalidade para as forças normal e tangencial no contato. As relações cinemáticas são descritas em termos de uma função diferenciável da distancia entre os corpos (gap). Para a discretização são empregados elementos hexaedricos de 8 nós com uma formulação híbrida - Enhanced Assumed Strain (EAS) e os efeitos de comportamento não-linear dos materiais envolvidos são considerados na presença de grandes deslocamentos e grandes deformações. A teoria da plasticidade é utilizada para modelar a natureza não-linear das relações constitutivas do duto. Aplicações considerando o problema de contato com atrito que surge na interação solo-duto são apresentadas. / [en] This research aims the development of a methodology based on the finite element method for 3D frictional contact problems such as the frictional contact problem that arises from the soil-pipe interaction of buried pipelines. The treatment of the contact restrictions and the incorporation of the friction law of the Coulomb type are carried out through a penalty method, where the contact restrictions are imposed in an approximated manner using penalty parameters for both normal and tangential forces. The cinematic relations are established in terms of the diferential funtion of the gap between bodies. Hexahedral eight-node elements are employed based on the Enhanced Assumed Strain (EAS) concept and the effects of the non-linear behavior of the materials are considered in presence of large displacements and large deformations. The theory of plasticity is used to model the non-linear nature of the constitutive relations of the pipe. Applications are presented considering the frictional contact problem that arises on the interaction surfaces of a buried structure such as an oil pipeline.

Page generated in 0.2014 seconds