11

Bifurcações induzidas por limites no contexto de estabilidade de tensão / Limit induced bifurcations in the context of voltage stability

Abrantes, Adriano Lima 09 August 2016 (has links)
A interligação dos sistemas elétricos de potência (SEPs) resultou em um aumento na complexidade dos mesmos. Além disso, devido a pressões econômicas e ambientais, os sistemas têm operado mais próximos aos seus limites de transmissão, o que aumenta a relevância de análises de segurança no contexto de estabilidade de tensão. Neste cenário, problemas associados à capacidade de transmissão do SEP, como a bifurcação induzida por limite (BIL), tornam-se mais importantes, criando a necessidade de ferramentas de análise apropriadas. Um dos objetivos deste projeto de mestrado é estudar mais profundamente as BILs para que se possa tratar melhor o fenômeno no contexto de estabilidade de tensão. Outro objetivo é o desenvolvimento de técnicas para avaliação da margem de estabilidade de tensão (MET) considerando a possibilidade de ocorrência de BIL. Finalmente, dada a grande importância e ampla utilização da análise de sensibilidade da MET devido à bifurcação sela-nó (BSN) em estudos de estabilidade de tensão, o equacionamento do problema de análise de sensibilidade da MET devido à BIL é o terceiro objetivo deste trabalho. A análise de sensibilidade é importante pois, não só fornece mais informações sobre o fenômeno de instabilidade e seus mecanismos, mas também auxilia na análise de segurança de SEPs, fornecendo informações sobre quais ações de controle serão mais eficazes na manutenção da MET e quais contingências serão mais severas. Isto é, quais mudanças no sistema mais afetam a MET. No entanto, este tipo de análise só foi realizado para o caso em que a MET é determinada por um ponto de BSN, não para o caso da BIL. Com o intuito de possibilitar que ferramentas de seleção de controles preventivos tratem o fenômeno da BIL, realizou-se uma análise de sensibilidade do ponto de BIL similar à análise usual baseada na BSN. Outra contribuição deste trabalho é uma formulação suave de limites complementares que foi aplicada ao problema de limites de injeção de potência reativa de unidades geradoras. A formulação proposta transforma, pelo menos numericamente, a BIL em uma BSN que pode ser detectada através de métodos já consolidados na literatura. / The interconnection of electric power systems (EPSs) led to an increase in security assessment complexity. Besides, due to economical and environmental inuences, EPSs have been operating closer to their transmission limits, which raises the relevance of security assessment in the context of voltage stability. In this scenario, problems related to EPS power transmission capacity, such as the limit induced bifurcation (LIB), become more important and bring the need of appropriate analysis tools. One of the goals of this project is to study the LIB problem more deeply, so it can be better understood in the context of voltage stability. Another objective is the development of methods for evaluating the load margin (LM) considering the possible occurrence of LIBs. Finally, since the LM sensitivity analysis due to saddle-node bifurcation (SNB) plays a highly important role in voltage stability studies, developing a method for LM sensitivity analysis due to LIB is our third objective. The sensitivity analysis is important not only because it provides information on the instability phenomenon and its mechanisms, but it is also useful for EPS security assessment, since it may provide knowledge on which control actions will be more eective in increasing the LM and which contingencies may be more severe. However, this analysis has been performed only for the case in which the LM is determined by a SNB point, not for the LIB case. With the intention of enabling pre-existing preventive control selection tools to treat the LIB phenomenon, a sensitivity analysis was performed at the LIB point similarly to what was developed for the SNB. Another contribution of this work is a smoothing formulation for complementary limits that was applied to the problem of limited reactive power injection of generating units. The proposed formulation transforms, at least numerically, the LIB in a SNB, which may be detected through methods already established in literature.
12

Método rápido para avaliação da margem de estabilidade de tensão devido a bifurcação de Hopf / Rapid method for evaluating the margin of voltage stability due to Hopf bifurcation

Oliveira, Karen Rezende Caino de 18 September 2009 (has links)
Apesar do crescente desenvolvimento das metodologias de detecção de bifurcações de Hopf em sistemas de energia elétrica nas últimas décadas, alguns aspectos ainda carecem de progressos, especialmente frente à crescente necessidade de aumento da segurança na operação dos sistemas eletroenergéticos. Um destes aspectos diz respeito ao tempo de processamento destas metodologias para serem utilizadas em tempo real na operação do sistema. Este tempo computacional é pouco considerado para este fim pelas metodologias atualmente existentes. Assim sendo, o presente trabalho apresenta um novo desenvolvimento relativo a estimação da margem de estabilidade do sistema de potência referente à bifurcação de Hopf e considera o tempo computacional envolvido neste processo a fim de incluir a margem devido a Hopf na operação em tempo real do sistema. O desenvolvimento apresentado estende uma das metodologias que compõe o estado da arte através da flexibilização de um dos parâmetros de interesse em relação a margem de estabilidade devido a bifurcação de Hopf, a saber, a frequência do autovalor no ponto de birfurcação. Esta metodologia utiliza o método de Newton em um conjunto de equações, e neste trabalho ainda é proposta a utilização de um tratamento da esparsidade para este conjunto de equações, deixando o algoritmo mais rápido. De forma a apresentar a eficiência desta metodologia proposta, esta foi testada em dois sistemas, o sistema Kundur de duas áreas e o sistema IEEE 39 barras. Os resultados obtidos são comparados frente a resultados obtidos também para a metodologia clássica utilizada em centros de operação. Através destes resultados é possível mostrar a possibilidade de sua utilização em tempo real e elucidar as grandes melhorias obtidas através do desenvolvimento proposto. / Despite the increasing development of Hopf bifurcations detection methods for electric power systems in the last decades, some aspects still require to progress, especially with the increasing necessity for higher safety in the electrical energy systems operation. One of these aspects concerns to the processing time of these methodologies to be used in real-time system operation. The computational time is disregarded for this purpose by the methods currently available. Therefore, this paper presents a new development for the power system stability margin estimation due to Hopf bifurcation and considers the computational time involved in this process to include the margin due to Hopf in electrical energy real-time operation. The presented development extends a methodology that makes up the state-of-the-art through an interest parameter relaxation in the stability margin due to Hopf bifurcation, namely, the eigenvalue frequency at the bifurcation point. This method uses Newton\'s method on a set of equations, and this work also proposes the use of a sparsity treatment for this set of equations, speeding up the algorithm. In order to demonstrate the proposed methodology efficiency, it was tested in two systems, the two areas Kundur system and the IEEE 39 bus system. The results are compared against the results of the classic methodology used in operation centers. Through these results it is possible to show the possibility of their use in real time and elucidate the major improvements resulting from the proposed development.
13

Uma contribuição ao estudo da estabilidade de tensão em sistemas elétricos de potência: novos aspectos relacionados à representação da carga. / A Contribution to the voltage stability studies within power systems: new aspects related to load representation.

Andrade, José Geraldo Barreto Monteiro de 08 October 2007 (has links)
Esse trabalho investiga o impacto do comportamento transitório e em regime permanente da carga sobre a estabilidade de tensão do sistema elétrico. Para isso, utiliza-se uma modelagem detalhada da rede elétrica, capaz de representar os principais eventos inerentes aos fenômenos de instabilidade e colapso de tensão. A simulação numérica do sistema algébrico-diferencial resultante é realizada utilizando-se o solver DASSLC. Ao final desse trabalho, faz-se uma análise da resposta dos diferentes modelos de carga sobre a estabilidade de tensão do sistema de 14 barras do IEEE. / This work investigates the impact of transient and steady state load behavior on power systems voltage stability. In order to do this, a detailed electric power system model is used to reproduce the main aspects of voltage instability and collapse phenomena. The numerical solution of the resulting non-linear differential-algebraic equations is carried out by using the DASSLC solver. An analysis of different load models behaviour for some voltage instability situations is presented for IEEE 14 bus system.
14

Bifurcações induzidas por limites no contexto de estabilidade de tensão / Limit induced bifurcations in the context of voltage stability

Adriano Lima Abrantes 09 August 2016 (has links)
A interligação dos sistemas elétricos de potência (SEPs) resultou em um aumento na complexidade dos mesmos. Além disso, devido a pressões econômicas e ambientais, os sistemas têm operado mais próximos aos seus limites de transmissão, o que aumenta a relevância de análises de segurança no contexto de estabilidade de tensão. Neste cenário, problemas associados à capacidade de transmissão do SEP, como a bifurcação induzida por limite (BIL), tornam-se mais importantes, criando a necessidade de ferramentas de análise apropriadas. Um dos objetivos deste projeto de mestrado é estudar mais profundamente as BILs para que se possa tratar melhor o fenômeno no contexto de estabilidade de tensão. Outro objetivo é o desenvolvimento de técnicas para avaliação da margem de estabilidade de tensão (MET) considerando a possibilidade de ocorrência de BIL. Finalmente, dada a grande importância e ampla utilização da análise de sensibilidade da MET devido à bifurcação sela-nó (BSN) em estudos de estabilidade de tensão, o equacionamento do problema de análise de sensibilidade da MET devido à BIL é o terceiro objetivo deste trabalho. A análise de sensibilidade é importante pois, não só fornece mais informações sobre o fenômeno de instabilidade e seus mecanismos, mas também auxilia na análise de segurança de SEPs, fornecendo informações sobre quais ações de controle serão mais eficazes na manutenção da MET e quais contingências serão mais severas. Isto é, quais mudanças no sistema mais afetam a MET. No entanto, este tipo de análise só foi realizado para o caso em que a MET é determinada por um ponto de BSN, não para o caso da BIL. Com o intuito de possibilitar que ferramentas de seleção de controles preventivos tratem o fenômeno da BIL, realizou-se uma análise de sensibilidade do ponto de BIL similar à análise usual baseada na BSN. Outra contribuição deste trabalho é uma formulação suave de limites complementares que foi aplicada ao problema de limites de injeção de potência reativa de unidades geradoras. A formulação proposta transforma, pelo menos numericamente, a BIL em uma BSN que pode ser detectada através de métodos já consolidados na literatura. / The interconnection of electric power systems (EPSs) led to an increase in security assessment complexity. Besides, due to economical and environmental inuences, EPSs have been operating closer to their transmission limits, which raises the relevance of security assessment in the context of voltage stability. In this scenario, problems related to EPS power transmission capacity, such as the limit induced bifurcation (LIB), become more important and bring the need of appropriate analysis tools. One of the goals of this project is to study the LIB problem more deeply, so it can be better understood in the context of voltage stability. Another objective is the development of methods for evaluating the load margin (LM) considering the possible occurrence of LIBs. Finally, since the LM sensitivity analysis due to saddle-node bifurcation (SNB) plays a highly important role in voltage stability studies, developing a method for LM sensitivity analysis due to LIB is our third objective. The sensitivity analysis is important not only because it provides information on the instability phenomenon and its mechanisms, but it is also useful for EPS security assessment, since it may provide knowledge on which control actions will be more eective in increasing the LM and which contingencies may be more severe. However, this analysis has been performed only for the case in which the LM is determined by a SNB point, not for the LIB case. With the intention of enabling pre-existing preventive control selection tools to treat the LIB phenomenon, a sensitivity analysis was performed at the LIB point similarly to what was developed for the SNB. Another contribution of this work is a smoothing formulation for complementary limits that was applied to the problem of limited reactive power injection of generating units. The proposed formulation transforms, at least numerically, the LIB in a SNB, which may be detected through methods already established in literature.
15

Método rápido para avaliação da margem de estabilidade de tensão devido a bifurcação de Hopf / Rapid method for evaluating the margin of voltage stability due to Hopf bifurcation

Karen Rezende Caino de Oliveira 18 September 2009 (has links)
Apesar do crescente desenvolvimento das metodologias de detecção de bifurcações de Hopf em sistemas de energia elétrica nas últimas décadas, alguns aspectos ainda carecem de progressos, especialmente frente à crescente necessidade de aumento da segurança na operação dos sistemas eletroenergéticos. Um destes aspectos diz respeito ao tempo de processamento destas metodologias para serem utilizadas em tempo real na operação do sistema. Este tempo computacional é pouco considerado para este fim pelas metodologias atualmente existentes. Assim sendo, o presente trabalho apresenta um novo desenvolvimento relativo a estimação da margem de estabilidade do sistema de potência referente à bifurcação de Hopf e considera o tempo computacional envolvido neste processo a fim de incluir a margem devido a Hopf na operação em tempo real do sistema. O desenvolvimento apresentado estende uma das metodologias que compõe o estado da arte através da flexibilização de um dos parâmetros de interesse em relação a margem de estabilidade devido a bifurcação de Hopf, a saber, a frequência do autovalor no ponto de birfurcação. Esta metodologia utiliza o método de Newton em um conjunto de equações, e neste trabalho ainda é proposta a utilização de um tratamento da esparsidade para este conjunto de equações, deixando o algoritmo mais rápido. De forma a apresentar a eficiência desta metodologia proposta, esta foi testada em dois sistemas, o sistema Kundur de duas áreas e o sistema IEEE 39 barras. Os resultados obtidos são comparados frente a resultados obtidos também para a metodologia clássica utilizada em centros de operação. Através destes resultados é possível mostrar a possibilidade de sua utilização em tempo real e elucidar as grandes melhorias obtidas através do desenvolvimento proposto. / Despite the increasing development of Hopf bifurcations detection methods for electric power systems in the last decades, some aspects still require to progress, especially with the increasing necessity for higher safety in the electrical energy systems operation. One of these aspects concerns to the processing time of these methodologies to be used in real-time system operation. The computational time is disregarded for this purpose by the methods currently available. Therefore, this paper presents a new development for the power system stability margin estimation due to Hopf bifurcation and considers the computational time involved in this process to include the margin due to Hopf in electrical energy real-time operation. The presented development extends a methodology that makes up the state-of-the-art through an interest parameter relaxation in the stability margin due to Hopf bifurcation, namely, the eigenvalue frequency at the bifurcation point. This method uses Newton\'s method on a set of equations, and this work also proposes the use of a sparsity treatment for this set of equations, speeding up the algorithm. In order to demonstrate the proposed methodology efficiency, it was tested in two systems, the two areas Kundur system and the IEEE 39 bus system. The results are compared against the results of the classic methodology used in operation centers. Through these results it is possible to show the possibility of their use in real time and elucidate the major improvements resulting from the proposed development.
16

Uma contribuição ao estudo da estabilidade de tensão em sistemas elétricos de potência: novos aspectos relacionados à representação da carga. / A Contribution to the voltage stability studies within power systems: new aspects related to load representation.

José Geraldo Barreto Monteiro de Andrade 08 October 2007 (has links)
Esse trabalho investiga o impacto do comportamento transitório e em regime permanente da carga sobre a estabilidade de tensão do sistema elétrico. Para isso, utiliza-se uma modelagem detalhada da rede elétrica, capaz de representar os principais eventos inerentes aos fenômenos de instabilidade e colapso de tensão. A simulação numérica do sistema algébrico-diferencial resultante é realizada utilizando-se o solver DASSLC. Ao final desse trabalho, faz-se uma análise da resposta dos diferentes modelos de carga sobre a estabilidade de tensão do sistema de 14 barras do IEEE. / This work investigates the impact of transient and steady state load behavior on power systems voltage stability. In order to do this, a detailed electric power system model is used to reproduce the main aspects of voltage instability and collapse phenomena. The numerical solution of the resulting non-linear differential-algebraic equations is carried out by using the DASSLC solver. An analysis of different load models behaviour for some voltage instability situations is presented for IEEE 14 bus system.
17

Avaliação da estabilidade de tensão nos sistemas de distribuição considerando a injeção de potência da geração distribuída / Voltage stability assessment in distribuition systems considering the power injection by distributed generation

Alves, Alessandro Arjona 01 April 2016 (has links)
Made available in DSpace on 2017-07-10T16:41:33Z (GMT). No. of bitstreams: 1 Dissertacao Alessandro Arjona Alves2 - Final.pdf: 1729270 bytes, checksum: eaef13266354526fc7d7558b8d6748d0 (MD5) Previous issue date: 2016-04-01 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The huge rise in electricity energy demand seen in recent decades, the growing interest in alternative and renewable energy sources have placed the distributed generation (DG) in evidence in the global energy landscape. This scenario brings a significant growth in the use of this energy source. Thus, different types of interface and primary sources of energy, with the possibility of allocating different points in the network and with different capabilities, distributed generation brings different impacts to the distribution systems, including power system voltage stability. The voltage stability in networks with distributed generation is the object of this study. To this end, it has been studied methods for power flow calculation, the fundamental concepts of voltage stability and methods of analysis. The aim of this research is to evaluate the distributed generation impact on the voltage stability. Therefore, it has been evaluated some technical aspects such as power factor, location and generation capacity. Through the development of the analysis it was possible to highlight the relationship between improvement in stability margin and the benefit in reducing losses caused by GD. Also it was found that, with a view to improving the margin of voltage stability, it is more efficient to inject power in the network with the same power factor of the system equivalent load. / O grande aumento de demanda por energia elétrica verificado nas últimas décadas, o crescente interesse por fontes alternativas e renováveis de energia tem colocado a geração distribuída (GD) em evidência no panorama energético mundial. Esse cenário propiciou um grande crescimento do uso deste tipo de fonte de energia. Assim, com diferentes tipos de interface e de fontes primárias de energia, com a possibilidade de alocação em distintos pontos da rede e com diferentes capacidades, a geração a distribuída traz diferentes impactos às redes de distribuição, inclusive à estabilidade de tensão dos sistemas. A estabilidade de tensão em redes com presença de geração distribuída é o objeto de estudo desta dissertação de mestrado. Neste sentido, são estudados os métodos para cálculo de fluxo de potência, os conceitos fundamentais da estabilidade de tensão e métodos de análise. O objetivo deste trabalho de pesquisa é avaliar os impactos da geração distribuída na estabilidade de tensão. Para tanto, foram avaliados alguns aspectos técnicos como fator de potência, localização e capacidade de geração. Através das análises desenvolvidas foi possível destacar a relação entre melhora na margem de estabilidade de tensão e o benefício em redução de perdas ocasionado pela GD. Também constatou-se que, com vistas à melhora da margem de estabilidade de tensão, é mais eficiente injetar potência na rede com o mesmo fator de potência da carga equivalente do sistema.
18

MODELAGEM DE CARGA DE UMA INDÚSTRIA DE GRANDE PORTE PARA ANÁLISE DE PROBLEMAS DE TENSÃO NO REGIME DINÂMICO / MODELING OF A LOAD OF BIG INDUSTRY FOR ANALYSIS OF PROBLEMS TENSION IN THE SCHEME OF DYNAMIC

Silva, Fábio Mendes da 27 October 2006 (has links)
Made available in DSpace on 2016-08-17T14:53:13Z (GMT). No. of bitstreams: 1 Fabio Mendes.pdf: 1170710 bytes, checksum: 82680998b91c71d757e674e600fb9799 (MD5) Previous issue date: 2006-10-27 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / The present work proposes an extended model representing part of a huge aluminum industry load for voltage stability investigations in time domain. The efforts were concentrated in the expansion of the industrial power distribution system model including explicit representation of the main transformers, capacitors, feeders and induction motors. The extended model is validated through a comparison between computer simulation results and the industry/power system utility recordings. A real sequence of events which took place in the Brazilian North Power System in the year of 2002 causing a complete industry breakdown (loss of bulk supply) was considered here for this purpose. / Este trabalho propõe um modelo estendido representando parte da carga de uma indústria de grande porte de alumínio para investigações do fenômeno da estabilidade de tensão no domínio do tempo. Os esforços se concentraram na expansão do modelo do sistema de distribuição industrial incluindo uma representação explícita dos principais transformadores, capacitores, alimentadores e motores de indução. O modelo expandindo é validado através de uma comparação entre os resultados das simulações computacionais e o de registradores alocados na indústria e no sistema elétrico. Uma seqüência real de eventos ocorrida no Sistema Elétrico do Norte do Brasil no ano de 2002 causando uma perda completa da indústria foi considerada para tal fim.
19

Análise de sensibilidade da margem de carregamento em sistemas elétricos de potência: um estudo comparativo / Sensitivity of loading margin in electrical power systems: a comparative study

Cantarino, Marcelo 09 July 2007 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-24T14:36:40Z No. of bitstreams: 1 marcelocantarino.pdf: 1124563 bytes, checksum: 25aa72244ea806af00361631d5fc961f (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-24T16:59:24Z (GMT) No. of bitstreams: 1 marcelocantarino.pdf: 1124563 bytes, checksum: 25aa72244ea806af00361631d5fc961f (MD5) / Made available in DSpace on 2017-04-24T16:59:24Z (GMT). No. of bitstreams: 1 marcelocantarino.pdf: 1124563 bytes, checksum: 25aa72244ea806af00361631d5fc961f (MD5) Previous issue date: 2007-07-09 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta um estudo comparativo da avaliação da sensibilidade da margem de carregamento em relação à variação de diferentes parâmetros elétricos do sistema, sem a necessidade de se revolver este problema da forma tradicional, ou seja, utilizando um programa de fluxo de potência continuado ou o método do ponto de colapso. Desta forma, obtém-se um ganho no tempo de resposta às perturbações sofridas pelo sistema, possibilitando ações de controle corretivo e preventivo mais eficazes. Como a análise de sensibilidade tem grande importância nos estudos da estabilidade de tensão, é necessário o desenvolvimento de novas metodologias e a avaliação das existentes, de modo a possibilitar uma análise mais eficiente e confiável da operação do sistema elétrico de potência em virtude das variações de seus parâmetros. Neste contexto, este trabalho apresenta um novo desenvolvimento matemático para a análise de sensibilidade utilizando as equações do fluxo de potência com tensões representadas em coordenadas retangulares, e estabelece um processo comparativo com o modelo tradicional expresso em termos das equações do fluxo de potência com tensões representadas em coordenadas polares. Os resultados produzidos pela metodologia de análise de sensibilidade são então comparados com os resultados exatos gerados pelo método do ponto de colapso. Sistemas testes IEEE e um modelo equivalente da região Sul-Sudeste brasileira são utilizados na simulação dos resultados. / This work presents a comparative study on the evaluation of the sensitivity of loading margin with respect to different electric system parameters, without the necessity of solving this problem by the conventional form using the continuation power flow or the point of collapse method. Therefore, a gain in the time response to the disturbances is obtained, making possible more efficient corrective and preventive control actions. As the sensitivity analysis has a great importance voltage stability studies, it is necessary to develop new methodologies and the evaluation of the existing ones, in order to make possible a more efficient and reliable operation analysis of the electrical power system due to the variations of its parameters. In this context, this work presents a new mathematical model for the sensitivity analysis using the power flow equations with the voltages in rectangular coordinates, and establishes a comparative process with the conventional model expressed in terms of power flow equations with the voltages in polar coordinates. The results provided by the sensitivity analysis are then compared with the actual results yielded by the point of collapse method. IEEE test systems and a South-Southeastern Brazilian network are used in the simulation of the results.
20

An approach to handle sudden load changes on static voltage stability analysis / Abordagem para considerar variações súbitas de carga na análise estática de estabilidade de tensão

Colombari, Luan Filipe dos Santos 03 March 2017 (has links)
In the context of static Voltage Stability Assessment (VSA), as the power system load grows, bus voltages tend to drop. This reduction may lead to generator or load disconnections caused by undervoltage protection schemes. These events comprise sudden parametric variations that affect the equilibrium diagram and the Voltage Stability Margin (VSM) of power systems. Practical examples of such sudden load changes are caused by the mandatory disconnection of Distributed Generation (DG) units and Undervoltage Load Shedding (ULS). There are no thorough studies in the literature concerning these load parametric variations and the discontinuities that they cause in power system equilibria. This dissertation describes a predictor/corrector scheme specifically designed to handle these discontinuities, so it is possible to evaluate their effect on the VSM of power systems. This method successively calculates the load discontinuities that exist in the equilibrium locus of the system under analysis. It results in the sequence of sudden load variations that happens and their overall impact on the system. When applied to quantify the effect of DG mandatory disconnections and ULS, the proposed predictor/corrector scheme yielded better results than the traditional Continuation Power Flow (CPFLOW), which experienced convergence problems caused by the discontinuities under analysis. However, due to its design, the applicability of the proposed method should be restricted to power systems that go through several successive sudden load changes. In this sense, it should not be regarded as a replacement for the CPFLOW, but rather as a technique that could award this traditional VSA tool with new features to enhance its performance. / No contexto de análise estática de estabilidade de tensão, conforme a carga de um sistema de potência cresce, as tensões nas suas barras tendem a cair. Essa redução pode causar a desconexão de geradores e cargas devido a atuação de proteções de subtensão. Esses eventos representam variações abruptas de demanda que alteram o diagrama de equilíbrio de um sistema e sua Margem de Estabilidade de Tensão (MET). Exemplos práticos dessas variações são causados pelo desligamento mandatório de unidades de Geração Distribuída (GD) e pelo Corte de Carga por Subtensão (CCS). Não há estudos detalhados na literatura que trabalham especificamente com essas variações nos parâmetros da carga, nem com as descontinuidades que elas causam no diagrama de equilíbrio de sistemas de potência. Essa dissertação descreve um procedimento especificamente projetado para lidar com essas descontinuidades, de modo que seja possível avaliar seu efeito na MET de sistemas elétricos. Esse método calcula sucessivamente as descontinuidades de carga que existem no diagrama de equilíbrio do sistema em análise. Ele resulta na sequência de variações súbitas de carga que ocorre e no seu impacto no sistema. Quando o método foi aplicado para quantificar o efeito do desligamento mandatório de GD e do CCS, ele apresentou resultados melhores do que o tradicional Fluxo de Carga Continuado (CPFLOW), o qual sofreu problemas de convergência causados pelas descontinuidades em questão. Entretanto, devido ao seu projeto, o método proposto só deve ser utilizado para sistemas de potência que estão sujeitos a várias sucessivas variações abruptas de carga. Por essa razão, esse método não pode ser considerado um substituto do CPFLOW, mas sim como uma técnica capaz de agregar novas funcionalidades a essa ferramenta tradicional, amentando assim seu horizonte de aplicações.