Spelling suggestions: "subject:"estética"" "subject:"dietética""
1 |
Parâmetros térmicos de solidificação, microestrutura e resistência mecânica de ligas eutéticas Sn-0,7%Cu-(xNi) / Solidification thermal parameters, microstructure and mechanical resistance of the eutectic Sn-0,7wt%Cu (-Ni) alloysSilva, Bismarck Luiz 29 July 2013 (has links)
Made available in DSpace on 2016-06-02T19:12:32Z (GMT). No. of bitstreams: 1
5520.pdf: 15957813 bytes, checksum: 79aec06af1bae5d8465f546113e03184 (MD5)
Previous issue date: 2013-07-29 / Sn-Pb traditional solder alloys were overly utilize in electronic devices industry, since their properties and features use were adequate and well known. In the last years many restrictions and directives were and have been designed with a view to minimize or eliminate the use of this metal in the electronic industry. Thereby, several lead-free solder alloys emerged. Among these alloys, eutectic Sn-0.7wt%Cu (TE=227°C) appears as potential candidate to replace eutectic Sn-37wt%Pb alloys, because present low cost when compared with the other lead-free solder alloys. Fatigue resistance and fluidity are quite similar compared with those obtained for the traditional Sn-Pb alloys. Small alloying additions of Ni in Sn-Cu eutectics between levels 20-1000ppm Ni can improve welding properties such as good fluidity, reliability, fine degree of wetting, ensuring suitable mechanical resistance of solder joint. Thus, the main goals of present study are investigate the influence of the Ni microadditions on solidification thermal parameters (transient interfacial heat transfer coefficient - hi), eutectic growth rate v and cooling rate - Ṫ), microstructure features (dendritic and cellular spacings, λ1 and λC) and tensile properties in directionally solidified Sn-0.7wt%Cu, Sn-0.7wt%Cu-0.05wt%Ni e Sn-0.7wt%Cu-0.1wt%Ni alloys under unsteady-state conditions against AISI steel carbon 1020 water-cooled bottom part. Measurements of hi coefficient showed that Ni microadditions (500 and 1000ppm of Ni) in the eutectic Sn-0.7wt%Cu affected significantly the fluidity levels. The microstructures obtained for the Sn-0,7wt%Cu-(xNi) alloys presented eutectic colonies/cells along the casting length, with dendritic regions only on first positions close to the bottom. Small Ni additions promoted increase on ultimate tensile strength (σu) and elongation (δ), with the Sn-0.7wt%Cu-0.05wt%Ni alloy corresponding to the better combination of σu and δ, 36.6MPa and 12.1%, respectively. / As tradicionais ligas de soldagem Sn-Pb foram excessivamente utilizadas na indústria de dispositivos eletrônicos, uma vez que suas características de uso e propriedades eram adequadas e bem conhecidas. Contudo, devido aos problemas acarretados pela toxidade do Pb, várias restrições/diretrizes foram e estão sendo criadas a fim de minimizar ou eliminar o uso desse metal na indústria eletrônica. Com isso, diversas ligas de soldagem livres de Pb surgiram e dentre tais ligas, a liga eutética Sn-0,7%Cu (TE=227°C) surge com uma alternativa promissora para a substituição de ligas de solda contendo Pb, pois apresentam menor custo que as demais ligas de soldagem e propriedades como resistência à fadiga e fluidez semelhantes às obtidas para ligas do sistema Sn-Pb. Neste contexto, microadições de Ni em ligas eutéticas Sn-Cu em níveis entre 20 e 1000ppm podem trazer melhorias de propriedades de soldagem como boa fluidez, boa soldabilidade, bom grau de molhamento, garantindo adequada resistência mecânica da junta soldada. Assim, o presente estudo objetiva investigar a influência de microadições de Ni nos parâmetros térmicos de solidificação (coeficiente interfacial de transferência de calor metal/molde - hi, velocidade de solidificação - v e taxa de resfriamento - Ṫ), nas características estruturais (espaçamento intercelular e interdendrítico, λC e λ1) e nas propriedades mecânicas de tração das ligas Sn-0,7%Cu, Sn-0,7%Cu-0,05%Ni e Sn-0,7%Cu-0,1%Ni solidificadas unidirecionalmente no sentido vertical ascendente contra chapa molde de aço carbono 1020. Os valores de hi mostraram que microadições de Ni (500 e 1000ppm) em ligas eutéticas Sn-0,7%Cu afetaram consideravelmente o nível de fluidez. As microestruturas das ligas Sn-0,7%Cu-(xNi) apresentaram colônias eutéticas ao longo dos lingotes, com regiões dendríticas apenas nas posições próximas da base refrigerada. As microadições de Ni promoveram um aumento do limite de resistência à tração (σu) e do alongamento específico (δ), com a liga Sn-0,7%Cu-0,05%Ni apresentando a melhor combinação σu/δ, 36,6 MPa e 12,1%, respectivamente.
|
2 |
Efeito de inoculantes para refino de grão e modificador de eutético na curva de resfriamento da liga A356 e da liga A356 reciclada / Effect of inoculants for grain refiniment and eutectic modifier in the cooling curve of A356 alloy and recycled A356 alloySilva, Cássia Cavalcanti [UNESP] 07 July 2016 (has links)
Submitted by Cassia Cavalcanti da Silva null (cassiacavalcanti@terra.com.br) on 2016-08-01T22:46:23Z
No. of bitstreams: 1
Silva_Cássia_2016.pdf: 9369604 bytes, checksum: d9e7dedc0ffe91324f392628a9e5c12f (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-03T16:09:39Z (GMT) No. of bitstreams: 1
silvia_cc_dr_guara.pdf: 9369604 bytes, checksum: d9e7dedc0ffe91324f392628a9e5c12f (MD5) / Made available in DSpace on 2016-08-03T16:09:39Z (GMT). No. of bitstreams: 1
silvia_cc_dr_guara.pdf: 9369604 bytes, checksum: d9e7dedc0ffe91324f392628a9e5c12f (MD5)
Previous issue date: 2016-07-07 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A liga AA 356 é uma liga Al-Si amplamente utilizada tanto na indústria automobilística como na aeronáutica. Para melhorar suas propriedades mecânicas, são usados inoculantes para o refino de grão e para modificação eutética. Os componentes solidificados em moldes metálicos, que são mais eficientes na extração de calor, em geral, têm propriedades mecânicas superiores àqueles solidificados em moldes de areia que apresentam uma menor taxa de extração de calor. A curva de resfriamento que é uma curva da temperatura em função do tempo obtida da extremidade de um termopar localizado no centro do molde e conectado a um sistema de aquisição de dados é uma ferramenta que permite avaliar tanto o refino de grão quanto a modificação eutética. Essa ferramenta permite observar também a formação de fases intermetálicas, e é influenciada por fatores como a taxa de resfriamento. A primeira derivada da curva de resfriamento que representa a taxa de resfriamento é parte da ferramenta, pois melhora a precisão dos dados obtidos com a curva de resfriamento. Para o desenvolvimento desse trabalho foram preparados lingotes variando-se o material do molde (areia e aço), o teor de modificador de eutético e a adição de refinador de grão, ambos na forma de ligas-mãe (ante-liga) Al-10Sr e Al-5Ti-1B, respectivamente. Os valores para traçar as curvas de resfriamento foram obtidos monitorando a temperatura do metal desde o vazamento até sua completa solidificação e posterior resfriamento. Amostras do material foram preparadas para metalografia e obtidas imagens de macroestrutura e microestrutura. Da microestrutura foram obtidas as imagens com o ataque químico convencional e o ataque químico profundo; foram realizadas medidas de fração de porosidade por área, por técnica de microscopia, além de medidas de dureza Vickers e Brinell. Os resultados confirmam que a técnica da análise térmica da curva de resfriamento é uma excelente ferramenta, pois além de fornecer as temperaturas solidus e liquidus, as temperaturas de transformações de fases e informações sobre a eficácia do refino de grão e modificação eutética, pode ser utilizada na avaliação da presença de impurezas e na identificação de fases presentes nas ligas, tanto da liga primária quanto da liga reciclada. / The alloy AA 356 is an Al-Si alloy widely used in the automotive and aeronautics industry. To improve the mechanical properties of this alloy inoculants are used to grain refine and eutectic modification. The solidified components in metal mold, with a higher heat extraction rate, generally have mechanical properties superior to those solidified in sand mold with a lower heat extraction rate. The cooling curve is a curve of temperature versus time obtained in the end of a thermocouple located in the center of the mold and connected to a data acquisition system. It is a tool to evaluate both the grain refinement as the eutectic modification. This tool also can also be used to observe the formation of intermetallic phases, and is influenced by factors such as the cooling rate. The first derivative of the curve representing the cooling rate is part of the tool because it improves the accuracy of the data obtained from the curve. For the development of this work ingots were prepared varying the mold material (sand and steel), the content of eutectic modifier and the grain refiner addition , both in the form of master alloys Al-10Sr and Al-5Ti-1B, respectively.The data for plotting the cooling curves were obtained experimentally during solidification; Samples of the material were prepared for metallography and macrostructure and microstructure images were obtained. Through microstructure images obtained with conventional etching and deep etching. Porosity fraction area was measured by microscopy technique and hardness measurements were performed by Vickers and Brinell metdhod. The results confirm that the thermal analysis of the cooling curve is an excellent tool because provides the solidus and liquidus temperatures and the phase transformations on the effectiveness of the grain refining and eutectic modification and it can be used to assess the presence of impurities in the phase identification, for both the primary alloy and the recycled alloy.
|
3 |
Estudo comparativo entre duas técnicas de analgesia na cirurgia de postectomia por Plastibell® : mistura eutética de prilocaína e lidacaína x bloqueio do nervo dorsal do pênisSalgado Filho, Marcello Fonseca 14 April 2010 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-12-16T17:15:33Z
No. of bitstreams: 1
marcellofonsecasalgadofilho.pdf: 9000247 bytes, checksum: a234119931ed8da56fb969e17bc8b078 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-12-19T13:03:57Z (GMT) No. of bitstreams: 1
marcellofonsecasalgadofilho.pdf: 9000247 bytes, checksum: a234119931ed8da56fb969e17bc8b078 (MD5) / Made available in DSpace on 2016-12-19T13:03:57Z (GMT). No. of bitstreams: 1
marcellofonsecasalgadofilho.pdf: 9000247 bytes, checksum: a234119931ed8da56fb969e17bc8b078 (MD5)
Previous issue date: 2010-04-14 / Introdução: O bloqueio do nervo dorsal do pênis (BNDP) e a anestesia local tópica (LT) com uma mistura eutética de prilocaína e lidacaína são técnicas de uso rotineiro, fácil aplicação e baixo índice de complicações na cirurgia de postectomia. Propôs-se avaliar qual delas apresenta melhor analgesia com menor efeito hemodinâmico na cirurgia de postectomia por Plastibell® em crianças. Pacientes e métodos: Este ensaio clínico randomizado foi conduzido com 41 meninos, submetidos à postectomia por Plastibell® divididos em dois grupos: LT e BNDP. O estudo foi aprovado pelo Comitê de Ética em Pesquisa em Humanos segundo as normas da declaração de Helsinki e pelo Clinical trials/FDA. Nos pacientes sorteados para a técnica LT, a pomada de mistura eutética de prilocaína e lidacaína era aplicada no prepúcio uma hora antes da cirurgia. Antes da indução anestésica, todas as crianças eram monitoradas com estetoscópio precordial e monitor multiparâmetro Datex Omeda®. A indução anestésica era padrão para os dois grupos, com concentração inspirada de sevoflurano a 8% sob máscara facial e ventilação espontânea. No grupo BNDP, fez-se o bloqueio do nervo dorsal do pênis com levobupivacaína a 0,5% na dose de 2mg/kg. Avaliaram-se a frequência cardíaca, a pressão arterial média, a frequência respiratória e os movimentos involuntários durante os momentos de indução anestésica, de bloqueio do nervo dorsal do pênis, um minuto após a incisão e no pós-operatório imediato. A dor foi avaliada na primeira e na vigésima quarta hora de pós-operatório, pela escala análogo visual de dor. Resultados: Os grupos foram homogêneos quanto à idade, peso, diâmetro da glande, comprimento do pênis e tempo cirúrgico. No grupo LT, observou-se uma tendência a aumento da freqüência cardíaca no momento 1 minuto pós-incisão (p = 0,073) e da pressão arterial media no momento 1 minuto pósincisão (p = 0,046). No grupo BNDP, houve aumento da freqüência cardíaca (p = 0,004) e da pressão arterial média (p = 0,016) no momento do bloqueio. Comparando os momentos de maiores estímulos hemodinâmicos em cada grupo (T2 no grupo LT e T1 no grupo BNDP), observamos um estímulo mais intenso no BNDP, com aumento significante da freqüência cardíaca (p = 0,001) e maior incidência de movimentos involuntários (p = 0,002). Não houve diferença na dor
7
na primeira e na vigésima quarta hora de pós-operatório entre os grupos estudados. A incidência de hematoma e edema em 24 horas de pós--operatório foi maior no grupo BNDP. Conclusão: A anestesia LT com a pomada de mistura eutética de prilocaína e lidacaína proporciona menor repercussão hemodinâmica e analgesia satisfatória ao procedimento de postectomia por Plastibell®, controle da dor pós-operatório e baixa incidência de complicações pós-operatórias em relação ao BNDP, quando ambas as técnicas estão associadas à anestesia geral inalatória com sevoflurano. / Introduction: The dorsal penile nerve block (DPNB) and local topical anesthesia (LT) with eutetic mixture lidocaine and prilocaine are current techniques with easy implementation and low complication rate in circumcision surgery. Herein, we evaluated which anesthetic technique provides better analgesia with less hemodynamic stimulation during circumcision with Plastibell® in children. Patients and methods: Forty-one boys who underwent circumcision with Plastibell® were divided at random into two groups: LT and DPNB. In LT group the ointment eutetic mixture lidocaine and prilocaine was applied to the foreskin one hour before surgery. Before inhalatory induction, all children were completely monitored. Inhalatory induction was standard for the two groups with 8% end-tidal concentration of sevoflurane on a facemask and spontaneous ventilation. After 10 minutes of anesthesia induction, the end-tidal sevoflurane concentration was decreased to 2%. In the DPNB a dorsal penile nerve block was done with levobupivacaine 0.5% (2 mg/kg). We evaluated the heart rate, respiratory rate mean arterial pressure, and involuntary movements in the moments of induction of anesthesia (T0); dorsal penile nerve block (T1); 1 minute post-incision (T2) and 1 minute after end of surgery (T3). And also pain 1 hour and 24 hours after surgery. Results: The groups were homogeneous when compared age, weight, diameter of the glands, penile length and surgical duration. In the LT group there was a tendency to increase Heart Rate at T2 (p = 0.073) and an increase of Mean Arterial Pressure at T2 (p = 0.046) when compared to the induction time. The DPNB group had an increase in Heart Rate (p = 0.004) and Mean Arterial Pressure (p = 0.016) at the block time (T1) when compared to T0 time. Comparing the moments of greatest hemodynamic stimulus for each group (T2 for LT and T1 for DPNB) we observed a more intense stimulus in DPNB group with a significant increase in Heart Rate (p = 0.001) and greater incidence of involuntary movements (57.1% vs. 10%; p = 0.002). There was no difference in the incidence of pain between the study groups. Post-operative complications were higher in DPNB, especially hematoma and edema. Conclusions: Anesthesia with eutetic mixture lidocaine and prilocaine provides satisfactory hemodynamic stable during circumcision with Plastibell®, pain control and less complication in the post
9
operative period when this technique is associated with general anesthesia with sevoflurane.
|
Page generated in 0.0596 seconds