• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 44
  • 1
  • Tagged with
  • 46
  • 46
  • 32
  • 30
  • 12
  • 11
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Desenvolvimento de métodos de extração e determinação de bifenilas policloradas por cromatografia gasosa e detector de captura de elétrons em óleo Ascarel, reator anaeróbio e solo / Development and validation of a method for determination of Polychlorinated Biphenyls (PCBs) of a standard solution PCB Congener MIX 1 by gas chromatography and electron capture detector in three different matrices: Askarel oil, samples from batch anaerobic reactors and soil

Maria Angela Tallarico Adorno 23 August 2013 (has links)
Bifenilas policloradas (PCBs) são componentes de óleo ascarel, usado extensamente (no Brasil até os anos 80) como isolante em transformadores de energia devido às suas propriedades físico-químicas como estabilidade térmica e alta constante dielétrica. Apesar de ter sido proibido em todo o mundo devido à alta toxicidade dos PCBs presentes em sua composição, ainda resta grande quantidade de ascarel em circulação como resíduo \"passivo\" e resultante de contaminação em trocas dos fluidos dos transformadores, além de vazamentos. A principal forma de eliminação é por incineração, que, além de ser um processo caro, pode provocar a formação de compostos mais tóxicos, as dioxinas. Por isso é importante o monitoramento da concentração dessas substâncias, a fim de evitar maiores impactos ambientais na sua disposição, bem como em estudos de biodegradação. Esta matriz é extremamente complexa, o que torna a extração e determinação desses analitos um processo trabalhoso e difícil. Neste trabalho avaliaram-se métodos de extração e determinação de PCBs presentes na solução padrão comercial PCB Congener MIX 1, SUPELCO (PCBs 10, 28, 52, 138, 153 e 180). O desenvolvimento de métodos de extração (cromatografia em coluna, extração líquido-líquido (L-L), extração em fase sólida (SPE) e micro-extração em fase sólida - SPME) dos PCBs foi seguido da determinação, por cromatografia gasosa com detector por captura de elétrons (CG/DCE), em três matrizes diferentes: óleo ascarel, amostras provenientes de reatores anaeróbios em batelada e solo. Os métodos cuja purificação e extração diminuíram o efeito dos interferentes da matriz, como SPE - Sulfoxide, cromatografia em coluna de sílica e extração L-L com n-hexano foram validados pela avaliação dos seguintes parâmetros: linearidade e faixa de aplicação; precisão instrumental; limite de detecção, limite de quantificação e recuperação absoluta. O critério de escolha entre os métodos para extração dos PCBs do óleo que forneceram maior eficiência (cartucho SPE Sulfoxide e coluna de sílica gel, após lavagem ácida; método da adição de padrão, entre 1,0 e 4,0 mg L-1) deve considerar a disponibilidade de recursos, pois a sílica gel é mais viável economicamente do que o cartucho SPE. Os valores de R2 > 0,99 para o método de extração com sílica, mesmo tendo sido considerados apenas três pontos para a curva de calibração, atestam maior linearidade do que o método com SPE Sulfoxide (R2 entre 0,97 e 0,99). A extração L-L e determinação por CG/DCE dos PCBs (padronização interna) de amostras provenientes de reatores anaeróbios em batelada (aquosas, em matriz extremamente complexa com biomassa e espuma de poliuretano para imobilização de microrganismos) foram eficientes na faixa de concentração entre 0,05 e 0,5 mg L-1. Esse método foi adequado para monitorar PCBs em estudo de degradação anaeróbia e teste de adsorção dos PCBs em espuma; forneceu linearidade com R2 entre 0,93 e 0,96 e limites de detecção de 0,048 a 0,298 mg L-1, além de recuperação absoluta entre 14,1% e 110,7%. As condições testadas por SPME não permitiram a extração dos PCBs de óleo e de solo, principalmente devido à dessorção incompleta dos PCBs da fibra de polidimetil-siloxano, de 100 μm. / Polychlorinated biphenyls (PCBs) are components of ascarel, oil widely used as insulation (until the \'80s in Brazil) due to its physicochemical properties such as thermal stability and high dielectric constant. Despite having been banned worldwide due to the high toxicity of PCBs present in its composition, there are still lots of outstanding ascarel as \"passive\" residue and resulting contamination of fluids in transformers exchanges, plus leaks. The main form of disposal is incineration, which, besides being costly, can cause the formation of more toxic compounds, that is, dioxins. It is therefore important to monitor the concentration of these substances in order to prevent further environmental impacts in their disposal, as well as in studies of biodegradation. This is an extremely complex matrix, which makes the extraction and determination of this analytes very difficult and labor intensive. In this work we have evaluated methods of extraction and determination of the PCBs present in the standard solution Congener MIX 1, SUPELCO (PCBs 10, 28, 52, 138, 153 e 180). The extraction and cleanup developed methods which reduced the effects of interfering matrix as solid phase extraction (SPE) - Sulfoxide, column chromatography on silica and liquid-liquid (L-L) extraction with n-hexane, and solid phase microextraction (SPME) after determination of the PCBs by gas chromatography with electron capture detector (GC/ECD) were validated by assessing the following parameters: linearity and range of application; instrumental precision; detection limit; limit of quantification and absolute recovery. The criterion for choosing between the methods for extraction of PCBs from the oil with a higher efficiency (SPE cartridge Sulfoxide and silica gel column, after acid washing; using the standard addition method, between 1.0 and 4.0 mg L-1) must evaluate the availability resources, since the silica gel is more economically viable than the SPE cartridge. The R2 values > 0.99 for silica extraction method, even though it was considered only three points for the calibration curve, attested higher linearity than the method with SPE Sulfoxide (R2 between 0.97 and 0.99). The L-L extraction and determination by GC/ECD of the PCBs (internal standardization) of samples from batch anaerobic reactors (aqueous, in a very complex matrix with biomass and polyurethane foam for the immobilization of microorganisms) were efficient in the concentration range between 0.05 and 0.5 mg L-1. This method was suitable to monitor PCBs in anaerobic degradation studies and its adsorption on foam; provided R2 linearity between 0.93 and 0.96 and detection limits from 0.048 to 0.298 mg L-1, as well as absolute recovery between 14.1% and 110.7%. The conditions tested for SPME technique did not allow the extraction of the PCBs from the oil and soil, mainly due to the \"incomplete dessorption\" of PCBs from the polydimethylsiloxane fiber of 100 micron.
42

Degradação de profenofós em solução aquosa e em ervilhas processadas por feixe de elétrons e a síntese de polímeros impressos para extração seletiva desse pesticida / Degradation of profenofos in aqueous solution and peas by electron beam processed and synthesis of imprinted polymers for selective extraction of this pesticide

Flavio Thihara Rodrigues 10 April 2015 (has links)
Profenofós é um organofosforado empregado como inseticida e acaricida amplamente utilizado no Brasil para o controle de pragas de cebolas, milho, soja, café, tomate, algodão, feijão, batata e outros. A irradiação é um processo empregado em todo o mundo e recomendada por diversos órgãos de saúde para a conservação de alimentos. A radiação ionizante utiliza raios gama, raios X ou aceleradores de elétrons e tem sido aplicada para eliminar ou reduzir a ação de agentes patogênicos e contribuir para aumentar o tempo de estocagem de vários alimentos. Os objetivos desse trabalho foram: (a) avaliar a degradação de soluções aquosas de profenofós submetidas à radiação ionizante, identificar e quantificar a formação de novos produtos por GC-MS; (b) analisar o efeito de feixe de elétrons em ervilhas inoculadas com soluções aquosas de profenofós; (c) sintetizar Polímeros Molecularmente Impressos (MIP) e Sílica Impressa Molecularmente (MIS), posteriormente, caracterizar os adsorventes em fase sólida e verificar sua seletividade para profenofós. O tratamento com aceleradores de elétrons com dose 31,6 kGy promoveu a formação de um novo produto de degradação e redução de 93,40 % de profenofós em soluções aquosas. Em ervilhas inoculadas com 1 μg de profenofós submetidas à radiação ionizante de 30,4 kGy promoveu uma redução na concentração de profenofós em 57,46 %. Além disso, foram realizadas sínteses de MIP e MIS para a extração em fase sólida de profenofós. Os MIS sintetizados por sol-gel mostraram-se eficazes para o reconhecimento molecular e extração seletiva de profenofós. / Profenofos is an organophosphate widely used in Brazil as insecticide and acaricide in the control of pests in onions, corn, soybeans, coffee, tomato, cotton, beans, potatoes among others. Irradiation is a process used worldwide and recommended by many health agencies for food preservation. Food irradiation preserving process uses accelerated electrons, gamma rays or X-rays. Ionizing radiation treatment is applied to eliminate or to reduce the action of pathogens and to increase the shelf life of some foods. The objective of this study were (a) to evaluate the degradation of aqueous solutions of Profenofos by ionizing radiation, identify and quantify the formation of new products by GC-MS; (b) to analyze the effects of electron beam in peas inoculated with aqueous solutions of Profenofos; (c) to synthesize Molecularly Imprinted Polymer (MIP) and Molecularly Imprinted Silica (MIS), subsequently characterize the adsorbents in solid phase and check its selectivity for profenofos. The treatment with electron accelerators with 31.6 kGy dose promoted the formation of a new by-product and 93.40 % reduction of profenofos in aqueous solutions. In peas inoculated with 1 μg of profenofos by ionizing radiation of 30.4 kGy promoted a reduction of 57.46 % in the concentration of profenofos. Furthermore, the MIP and MIS were performed for solid phase extraction of profenofos. The MIS synthesized by sol-gel proved to be effective for the recognition molecular and selective extraction of profenofos.
43

Novos dispositivos de microextração e pré-concentração para eletroforese capilar utilizando membranas microporosas ou processos eletroquímicos e sua potencialidade na análise de aminas e metais / New devices to extraction and preconcentration with microporous membranes and electrochemical procedures prior to capillary electrophoresis: some applications to amines and metals analysis

Antunes Junior, Osmar 13 October 2008 (has links)
A eletroforese capilar (CE) é uma técnica de separação eficiente, que tem merecido grande atenção nas últimas duas décadas, e que oferece soluções analíticas alternativas ou complementares à cromatografia líquida num número crescente campos de aplicação, incluindo análises de fármacos, compostos biológicos e biogênicos, dentre outros. Entre as vantagens comparativas da técnica figuram separações mais rápidas com pequeno dispêndio de amostras, solução tampão (e solvente orgânico, se usado), baixo custo de operação e manutenção. Todavia, a exigüidade de amostra no capilar tem como reflexo, via de regra, limites de detecção menos favoráveis que os da HPLC, uma limitação significativa na análise de traços, suplantável por técnicas e procedimentos de extração/acumulação prévia dos analitos. Nesta tese concebeu-se e implementou-se a combinação inédita entre a CE e a préconcentração eletroquímica de metais. Novos dispositivos para extração líquido/gás/líquido mediada por membranas microporosas também foram propostos e aplicados à analise de aminas voláteis, sempre utilizando detector de condutância medida sem contato direto com a solução (C4D, contactless capacitively coupled conductivity detection). Primeiramente, sem recorrer à preconcentração, definiu-se condições de análise para 16 aminas (metilamina, dimetilamina, trimetilamina, propilamina, n-butilamina, s-butilamina, t-butilamina, hexilamina, DMAE, etanolamina, dietanolamina, trietanolamina, 1,3-diaminopropano, 1,4-diaminobutano, 1,5-diaminopentano e 1,6-diaminohexano) juntamente com íon amônio, e, para análise de 9 metais (TI++, Cd2+, Pb2+,Cr3+, Zn2+, Ag+, Cu2+, Co2+ e Ni2+). Um método completo para análise de dimetilaminoetanol em formulações cosméticas por CE-C4D foi desenvolvido e validado. Os estudos de extração e pré-concentração líquido/gás/líquido foram realizados utilizando filamento oco de Oxyphan preenchido com solução coletora. Foi construída cela para extração gasosa constituída de recipiente fechado no qual se introduz amostra com analitos voláteis, ou volatilizáveis pela adição de reagente e/ou aquecimento (pervaporação). A bobina coletora de filamento oco preenchido com solução coletora foi montada na parte interna da tampa da cela. Testes realizados com amostras de tecidos de peixe demonstraram o funcionamento do sistema, que poderá ser aperfeiçoado e aplicado, por exemplo, à análise de aminas biogênicas primárias de baixo peso molecular, indicadoras de decomposição de certos alimentos. Criou-se também extrator microvolumétrico em que o filamento de Oxyphan é montado concentricamente no interior de um capilar de sílica fundida, para realização de estudos de extração líquido/gás/líquido em fluxo. Um sistema em fluxo compreendendo válvulas e microbombas foi montado e colocado sob controle de um programa de computador (Labview), que, entre outras funções, controla o deslocamento da solução coletora exposta no filamento oco (13 µL) até o ponto exato da interface em que se dá a injeção no capilar da CE. Pela primeira vez recorreu-se à acumulação eletroquímica (ECPC) de analitos num sistema FIA-CE-C4D - uma configuração baseada inteiramente na eletroquímica -, visando expandir os limites de detecção das determinações e eliminar interferência de matriz por troca de meio. Implementou-se a pré-concentração catódica seguida de redissolução anódica com uma célula eletroquímica especial, em que o capilar da eletroforese é posicionado junto ao eletrodo de trabalho, feito de ouro obtido a partir de CD\'s graváveis. Uma célula microfluídica ECPC-FIA-CE-C4D também foi construída. Tomando íons Cu2+ como sistema modelo, demonstrou-se o aumento do sinal referente aos íons cobre(lI) no eletroferograma para tempos crescentes de acumulação eletroquímica. Para a solução de alto teor salino contendo mistura dos íons Cd(II), Pb(II), Zn(lI) e Cu(II), comprovou-se a eliminação da interferência da matriz por troca de meio antes da redissolução anódica. Os testes iniciais indicam que os novos dispositivos e sistemas propostos nesta tese para uso em conjunto com a CE têm potencialidade para desencadear novas pesquisas, desenvolvimento de métodos e aplicações, sendo passíveis também de miniaturização e automação. / Capillary electrophoresis (CE) is an efficient separation technique that evolved rapidly in the last couple of decades, now offering complementary or alternative analytical solutions to liquid chromatography for an expanding number of application fields including drugs, biological and biogenic compounds. Some comparative advantages of CE are faster separation, very low consumption of buffer solutions and samples (and organic solvents, if any), lower maintenance and operational costs. However, the quantification of a few nanoliters of analyte in a capillary, as a rule, compromises the detection limits attainable by HPLC, a shortcomming in trace analysis, suplantable by extraction/preconcentration of the analytes from the sample. The combination of electrochemical preconcentration (ECPC) with CE is first proposed in this thesis and tested with metal ions. New devices for liquid/gas/liquid extraction based on microporous filaments filled with a collector solution were proposed and applied to the analysis of volatile amines, The detector of choice was the C4D (capacitively coupled contactless conductivity detection) and CE-C4D working conditions were defined for the separation and determination of: i) 16 amines (methylamine, dimethylamine, trimethylamine, propylamine, n-butylamine, s-butylamine, t-butylamine, hexilamine, ethanolamine, diethanolamine, triethanolamine, DMAE, 1,3-diaminopropane, 1,4- diaminobutane, 1,5-diaminopentane and 1,6-diaminohexane) plus ammonium, ii) nine metallic ions (Tl+, Cd2+, Pb2+, Cr3+ Zn2+, Ag+, Cu2+, Co2+ e Ni2+). A complete method of analysis for Dimethyl-amino-ethanol (DMAE) in cosmetic formulations was established and validated. Liquid/gas/liquid extraction studies were based on the use of a polypropylene microporous filment (Oxyphan® ) filled with the collection solution. A closed cell was devised in which an Oxyphan® coil is installed beneath the cap and volatilization of sample components can be promoted by heating (pervaporation) or addition of a reactant. The device was successfully tested with fish samples by the detection of primary low molecular weight biogenic amines, a procedure of special interest in fast checking of fish or other foods for decomposition. A microvolumetric version of the liquid/gas/liquid extractor was created with an Oxyphan® hollow fiber mounted concentrically inside a silica capillary. A flow system comprising the micropumps, solenoid valves and the microextrator was designed, automatically operated under software control (Labview). This FIA-CE system was tested by the extraction/enrichment of volatile amines in the collecting solution (13 µL) followed by accurate displacement to the interface with the CE capillary by the micropumps. Pioneering work with ECPC-FIA-CE-C4D an all-electrochemical system was conducted in this thesis aiming expanded detection limits and matrix effect reduction. An electrochemical cell for the interface with FIA-CE system was built in acrylic using gold electrodes made from gold-sputtered CD-Rs. A microfluidic version of the cell interfaced with the CE capillary was also conceived. The full system was evaluated by using Cu2+ as a model specie; an increase in analytical signal was observed as a function of the cathodic deposition time before stripping. For a mixture of Cd2+, Cu2+, Zn2+ and Pb2+ in a high saline media, elimination of the matrix interference by medium exchange before stripping was demonstrated. Initial favorable evaluations show that the devices and systems proposed in 12 the thesis have the potential to engender further research of methods and applications as well as miniaturization and automation of procedures.
44

Degradação de profenofós em solução aquosa e em ervilhas processadas por feixe de elétrons e a síntese de polímeros impressos para extração seletiva desse pesticida / Degradation of profenofos in aqueous solution and peas by electron beam processed and synthesis of imprinted polymers for selective extraction of this pesticide

Rodrigues, Flavio Thihara 10 April 2015 (has links)
Profenofós é um organofosforado empregado como inseticida e acaricida amplamente utilizado no Brasil para o controle de pragas de cebolas, milho, soja, café, tomate, algodão, feijão, batata e outros. A irradiação é um processo empregado em todo o mundo e recomendada por diversos órgãos de saúde para a conservação de alimentos. A radiação ionizante utiliza raios gama, raios X ou aceleradores de elétrons e tem sido aplicada para eliminar ou reduzir a ação de agentes patogênicos e contribuir para aumentar o tempo de estocagem de vários alimentos. Os objetivos desse trabalho foram: (a) avaliar a degradação de soluções aquosas de profenofós submetidas à radiação ionizante, identificar e quantificar a formação de novos produtos por GC-MS; (b) analisar o efeito de feixe de elétrons em ervilhas inoculadas com soluções aquosas de profenofós; (c) sintetizar Polímeros Molecularmente Impressos (MIP) e Sílica Impressa Molecularmente (MIS), posteriormente, caracterizar os adsorventes em fase sólida e verificar sua seletividade para profenofós. O tratamento com aceleradores de elétrons com dose 31,6 kGy promoveu a formação de um novo produto de degradação e redução de 93,40 % de profenofós em soluções aquosas. Em ervilhas inoculadas com 1 μg de profenofós submetidas à radiação ionizante de 30,4 kGy promoveu uma redução na concentração de profenofós em 57,46 %. Além disso, foram realizadas sínteses de MIP e MIS para a extração em fase sólida de profenofós. Os MIS sintetizados por sol-gel mostraram-se eficazes para o reconhecimento molecular e extração seletiva de profenofós. / Profenofos is an organophosphate widely used in Brazil as insecticide and acaricide in the control of pests in onions, corn, soybeans, coffee, tomato, cotton, beans, potatoes among others. Irradiation is a process used worldwide and recommended by many health agencies for food preservation. Food irradiation preserving process uses accelerated electrons, gamma rays or X-rays. Ionizing radiation treatment is applied to eliminate or to reduce the action of pathogens and to increase the shelf life of some foods. The objective of this study were (a) to evaluate the degradation of aqueous solutions of Profenofos by ionizing radiation, identify and quantify the formation of new products by GC-MS; (b) to analyze the effects of electron beam in peas inoculated with aqueous solutions of Profenofos; (c) to synthesize Molecularly Imprinted Polymer (MIP) and Molecularly Imprinted Silica (MIS), subsequently characterize the adsorbents in solid phase and check its selectivity for profenofos. The treatment with electron accelerators with 31.6 kGy dose promoted the formation of a new by-product and 93.40 % reduction of profenofos in aqueous solutions. In peas inoculated with 1 μg of profenofos by ionizing radiation of 30.4 kGy promoted a reduction of 57.46 % in the concentration of profenofos. Furthermore, the MIP and MIS were performed for solid phase extraction of profenofos. The MIS synthesized by sol-gel proved to be effective for the recognition molecular and selective extraction of profenofos.
45

Novos dispositivos de microextração e pré-concentração para eletroforese capilar utilizando membranas microporosas ou processos eletroquímicos e sua potencialidade na análise de aminas e metais / New devices to extraction and preconcentration with microporous membranes and electrochemical procedures prior to capillary electrophoresis: some applications to amines and metals analysis

Osmar Antunes Junior 13 October 2008 (has links)
A eletroforese capilar (CE) é uma técnica de separação eficiente, que tem merecido grande atenção nas últimas duas décadas, e que oferece soluções analíticas alternativas ou complementares à cromatografia líquida num número crescente campos de aplicação, incluindo análises de fármacos, compostos biológicos e biogênicos, dentre outros. Entre as vantagens comparativas da técnica figuram separações mais rápidas com pequeno dispêndio de amostras, solução tampão (e solvente orgânico, se usado), baixo custo de operação e manutenção. Todavia, a exigüidade de amostra no capilar tem como reflexo, via de regra, limites de detecção menos favoráveis que os da HPLC, uma limitação significativa na análise de traços, suplantável por técnicas e procedimentos de extração/acumulação prévia dos analitos. Nesta tese concebeu-se e implementou-se a combinação inédita entre a CE e a préconcentração eletroquímica de metais. Novos dispositivos para extração líquido/gás/líquido mediada por membranas microporosas também foram propostos e aplicados à analise de aminas voláteis, sempre utilizando detector de condutância medida sem contato direto com a solução (C4D, contactless capacitively coupled conductivity detection). Primeiramente, sem recorrer à preconcentração, definiu-se condições de análise para 16 aminas (metilamina, dimetilamina, trimetilamina, propilamina, n-butilamina, s-butilamina, t-butilamina, hexilamina, DMAE, etanolamina, dietanolamina, trietanolamina, 1,3-diaminopropano, 1,4-diaminobutano, 1,5-diaminopentano e 1,6-diaminohexano) juntamente com íon amônio, e, para análise de 9 metais (TI++, Cd2+, Pb2+,Cr3+, Zn2+, Ag+, Cu2+, Co2+ e Ni2+). Um método completo para análise de dimetilaminoetanol em formulações cosméticas por CE-C4D foi desenvolvido e validado. Os estudos de extração e pré-concentração líquido/gás/líquido foram realizados utilizando filamento oco de Oxyphan preenchido com solução coletora. Foi construída cela para extração gasosa constituída de recipiente fechado no qual se introduz amostra com analitos voláteis, ou volatilizáveis pela adição de reagente e/ou aquecimento (pervaporação). A bobina coletora de filamento oco preenchido com solução coletora foi montada na parte interna da tampa da cela. Testes realizados com amostras de tecidos de peixe demonstraram o funcionamento do sistema, que poderá ser aperfeiçoado e aplicado, por exemplo, à análise de aminas biogênicas primárias de baixo peso molecular, indicadoras de decomposição de certos alimentos. Criou-se também extrator microvolumétrico em que o filamento de Oxyphan é montado concentricamente no interior de um capilar de sílica fundida, para realização de estudos de extração líquido/gás/líquido em fluxo. Um sistema em fluxo compreendendo válvulas e microbombas foi montado e colocado sob controle de um programa de computador (Labview), que, entre outras funções, controla o deslocamento da solução coletora exposta no filamento oco (13 µL) até o ponto exato da interface em que se dá a injeção no capilar da CE. Pela primeira vez recorreu-se à acumulação eletroquímica (ECPC) de analitos num sistema FIA-CE-C4D - uma configuração baseada inteiramente na eletroquímica -, visando expandir os limites de detecção das determinações e eliminar interferência de matriz por troca de meio. Implementou-se a pré-concentração catódica seguida de redissolução anódica com uma célula eletroquímica especial, em que o capilar da eletroforese é posicionado junto ao eletrodo de trabalho, feito de ouro obtido a partir de CD\'s graváveis. Uma célula microfluídica ECPC-FIA-CE-C4D também foi construída. Tomando íons Cu2+ como sistema modelo, demonstrou-se o aumento do sinal referente aos íons cobre(lI) no eletroferograma para tempos crescentes de acumulação eletroquímica. Para a solução de alto teor salino contendo mistura dos íons Cd(II), Pb(II), Zn(lI) e Cu(II), comprovou-se a eliminação da interferência da matriz por troca de meio antes da redissolução anódica. Os testes iniciais indicam que os novos dispositivos e sistemas propostos nesta tese para uso em conjunto com a CE têm potencialidade para desencadear novas pesquisas, desenvolvimento de métodos e aplicações, sendo passíveis também de miniaturização e automação. / Capillary electrophoresis (CE) is an efficient separation technique that evolved rapidly in the last couple of decades, now offering complementary or alternative analytical solutions to liquid chromatography for an expanding number of application fields including drugs, biological and biogenic compounds. Some comparative advantages of CE are faster separation, very low consumption of buffer solutions and samples (and organic solvents, if any), lower maintenance and operational costs. However, the quantification of a few nanoliters of analyte in a capillary, as a rule, compromises the detection limits attainable by HPLC, a shortcomming in trace analysis, suplantable by extraction/preconcentration of the analytes from the sample. The combination of electrochemical preconcentration (ECPC) with CE is first proposed in this thesis and tested with metal ions. New devices for liquid/gas/liquid extraction based on microporous filaments filled with a collector solution were proposed and applied to the analysis of volatile amines, The detector of choice was the C4D (capacitively coupled contactless conductivity detection) and CE-C4D working conditions were defined for the separation and determination of: i) 16 amines (methylamine, dimethylamine, trimethylamine, propylamine, n-butylamine, s-butylamine, t-butylamine, hexilamine, ethanolamine, diethanolamine, triethanolamine, DMAE, 1,3-diaminopropane, 1,4- diaminobutane, 1,5-diaminopentane and 1,6-diaminohexane) plus ammonium, ii) nine metallic ions (Tl+, Cd2+, Pb2+, Cr3+ Zn2+, Ag+, Cu2+, Co2+ e Ni2+). A complete method of analysis for Dimethyl-amino-ethanol (DMAE) in cosmetic formulations was established and validated. Liquid/gas/liquid extraction studies were based on the use of a polypropylene microporous filment (Oxyphan® ) filled with the collection solution. A closed cell was devised in which an Oxyphan® coil is installed beneath the cap and volatilization of sample components can be promoted by heating (pervaporation) or addition of a reactant. The device was successfully tested with fish samples by the detection of primary low molecular weight biogenic amines, a procedure of special interest in fast checking of fish or other foods for decomposition. A microvolumetric version of the liquid/gas/liquid extractor was created with an Oxyphan® hollow fiber mounted concentrically inside a silica capillary. A flow system comprising the micropumps, solenoid valves and the microextrator was designed, automatically operated under software control (Labview). This FIA-CE system was tested by the extraction/enrichment of volatile amines in the collecting solution (13 µL) followed by accurate displacement to the interface with the CE capillary by the micropumps. Pioneering work with ECPC-FIA-CE-C4D an all-electrochemical system was conducted in this thesis aiming expanded detection limits and matrix effect reduction. An electrochemical cell for the interface with FIA-CE system was built in acrylic using gold electrodes made from gold-sputtered CD-Rs. A microfluidic version of the cell interfaced with the CE capillary was also conceived. The full system was evaluated by using Cu2+ as a model specie; an increase in analytical signal was observed as a function of the cathodic deposition time before stripping. For a mixture of Cd2+, Cu2+, Zn2+ and Pb2+ in a high saline media, elimination of the matrix interference by medium exchange before stripping was demonstrated. Initial favorable evaluations show that the devices and systems proposed in 12 the thesis have the potential to engender further research of methods and applications as well as miniaturization and automation of procedures.
46

Comparação entre analisadores com fluxo constante ou pulsado: aplicação a amostras de relevância farmacêutica, agronômica e/ou ambiental / Comparison of flow analyzers exploiting constant or pulsed flows: application to samples of pharmaceutical, agronomical and/or environmental relevance

Milton Katsumi Sasaki 24 November 2015 (has links)
Sistemas de análises químicas em fluxo com multi-impulsão empregam bombas solenoide como unidade propulsora de fluidos, as quais proporcionam fluxos pulsados. Estes provêm um eficiente transporte radial de massas, o que garante boa homogeneização das soluções envolvidas, mesmo em situações de dispersão limitada. O objetivo principal deste trabalho foi então comparar o desempenho de metodologias envolvendo reagentes imobilizados em sistemas de análises em fluxo com fluxos constantes ou pulsados. Para isto, foram selecionadas as determinações espectrofotométricas de ácido ascórbico em produtos farmacêuticos, utilizando reator tubular de polietileno (50 cm) com MnO2(s) imobilizado, e reação com formaldoxima (0,25 mol L-1); e de carbaril em águas naturais, explorando extração líquido-líquido com xileno imobilizado em membrana de PVDF, e solução de NaOH a 0,1 mol L-1 como fluxo aceptor. Adicionalmente, compararam-se os dois tipos de fluxo em uma nova titulação em fluxo, a titulação monitorada por traçador; a determinação de acidez total em vinagres foi selecionada e utilizaram-se as titulações por injeção em fluxo e programada em triângulo, ambas empregando solução de NaOH a 0,01 mol L-1 como titulante e fenolftaleína como indicador ácido-base, com monitoramento por traçador empregando azul brilhante FCF (ca. 6 mg L-1). Na determinação de ácido ascórbico, o desempenho do sistema com fluxos pulsados foi superior àquele com fluxos constantes quanto ao limite de detecção: 0,33 contra 0,60 mg L-1 (critério 3,3 ?), e à repetibilidade: d.p.r. estimado como 2,5 contra 5,6% (n = 20); quanto à exatidão, não foi encontrada diferença estatisticamente significativa entre o método proposto e o da Farmacopeia Britânica ao nível de confiança de 95%. Na determinação de carbaril, o uso de fluxos pulsados favoreceu a extração do analito, obtendo-se uma sensibilidade 9,3% maior relativamente ao emprego de fluxos constantes, além de uma melhor linearidade da curva analítica; entretanto, o método mostrou-se susceptível a interferência de outros metilcarbamatos, o que comprometeu sua aplicação à análise de águas naturais. Na determinação de acidez total, a exploração de fluxos pulsados proporcionou menores variações da razão dos valores de absorbância relativos ao monitoramento do traçador e do indicador; não foi encontrada diferença estatística entre as titulações em fluxo propostas e o método titulométrico de referência ao nível de confiança de 95% / Multi-pumping flow systems use solenoid pumps as fluid propelling devices, which deliver pulsed flows. These flows provide an efficient radial mass transport, thus good mixing conditions even in limited sample dispersion situations. The main objective of this work was then to compare the performance of methodologies involving immobilized reagents in flow systems with constant or pulsed flows. To this end, the spectrophotometric determinations of ascorbic acid in pharmaceutical products using a 50-cm polyethylene tubular reactor with immobilized MnO2(s) with further colour-forming reaction with 0.25 mol L-1 formaldoxime; and carbaryl in natural waters exploiting liquid-liquid extraction with xylene immobilized in a PVDF membrane and a 0.1 mol L-1 ¬¬NaOH solution as acceptor stream, were selected. Moreover, constant and pulsed flows were compared in relation to a novel strategy for flow titration, named tracer-monitored titration; the determination of total acidity in vinegars was selected and flow injection and triangle-programmed titrations were applied, both using a 0.01 mol L-1 NaOH solution as titrant, phenolphtalein as acid-base indicator and ca. 6 mg L-1 brilliant blue FCF as tracer. Regarding ascorbic acid determination, the pulsed flow system was superior in relation to the constant flow system for detection limit: 0.33 against 0.60 mg L-1 (3.3 ? criterion), and for repeatability: r.s.d. estimated as 2.5 against 5.6% (n = 20); in relation to accuracy, no significant differences between the proposed method and that of the British Pharmacopoeia were found at the 95% confidence level. Regarding carbaryl determination, use of pulsed flows favored the analyte extraction, leading to a 9.3% sensitivity improvement in relation to use of constant flows; besides the attainment of better linearity of the analytical curve. The method was however susceptible to interference of other methylcarbamates, thus the application to natural water analyses was impaired. Regarding total acidity determination, pulsed flows exploitation provided lower variations in the ratio of absorbance values related to the monitoring of tracer and indicator; no significant differences between the proposed titrations and the reference method were found at the 95% confidence level

Page generated in 0.0741 seconds