• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 45
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 48
  • 31
  • 21
  • 19
  • 18
  • 14
  • 11
  • 9
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência do tipo de preparo na resistência à fratura (sob teste de compressão) de dentes restaurados com facetas cerâmicas obtidas por um sistema CAD/CAM

Gutiérrez Halabí, Celso Ignacio Roberto January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014. / Made available in DSpace on 2014-08-06T18:08:36Z (GMT). No. of bitstreams: 1 326579.pdf: 7453410 bytes, checksum: f42b176c9f2113d7ccccdfbbef95a637 (MD5) Previous issue date: 2014 / O objetivo deste estudo foi avaliar a influência do tipo de preparo na resistência à fratura (sob teste de compressão) de facetas cerâmicas realizadas com o sistema CAD/CAM em incisivos inferiores. Trinta incisivos hígidos foram, aleatoriamente, divididos em 3 grupos: 1 (DH) - Dente hígido, 2 (SRI) - Preparo vestibular sem redução incisal e faceta cerâmica e, 3 (CRI) - Preparo vestibular com redução incisal e faceta cerâmica. Os preparos foram realizados com pontas diamantadas esféricas número 1011 e tronco-cônicas números 4138, 4138F e 4138FF (Microdont, São Paulo, SP, Brasil) e conferidos com guias de silicone (Virtual, Ivoclar Vivadent, Schaan, Liechtenstein) e uma sonda milimetrada. Todas as facetas cerâmicas foram desenhadas utilizando o CEREC 3D (Software V.3.80) e posteriormente fresadas no CEREC MC XL (Sirona Dental Systems, Bensheim, Germany). Utilizou-se, para todas as restaurações o bloco IPS e.max CAD LT BL1/C14 (Ivoclar Vivadent, Schaan, Liechtenstein). Todos os espécimes foram incluídos em um cilindro de PVC (Bucha de redução soldável, Tigre, Brasil) em uma angulação de 65°. Após armazenamento em água destilada a 37ºC durante uma semana, os corpos de prova foram submetidos ao teste de fratura, e ,subsequentemente, a análise do padrão de fratura após o teste. A análise estatística demostrou que houve diferença significativa entre os grupos G1 (DH) e G3 (CRI), e G2 (SRI) e G3 (CRI) (p>0.05). Demonstrou-se que a redução incisal de 1.5 mm diminui a resistência à fratura do complexo dente-restauração, sob forças e compressão. Com relação ao tipo de fratura foi observado que 19 (63,33%) dos espécimes fraturaram exclusivamente no dente, enquanto em 5 (16,66%) espécimes a fratura foi apenas da restauração cerâmica, e em 13 (43,33%) espécimes a fratura foi tanto no dente como na restauração cerâmica. Concluiu-se que o desgaste da borda incisal em preparos para facetas cerâmicas, em dentes inferiores, diminui a resistência à fratura do conjunto dente/restauração.
2

Influência da espessura do material cerâmico à base de dissilicato de lítio sobre a resistência flexural e resistência à fratura de facetas do tipo "lentes de contato"

Silva, Daniel Baptista da January 2014 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014 / Made available in DSpace on 2015-02-05T21:20:58Z (GMT). No. of bitstreams: 1 329772.pdf: 72339437 bytes, checksum: 05e2ef1a68340653dd5529d8d92938f1 (MD5) Previous issue date: 2014 / Objetivo: Avaliar a resistência à fratura, em dentes bovinos, de facetas cerâmicas de diferentes espessuras e a influência da espessura de uma cerâmica à base de dissilicato de lítio sobre a resistência flexural da mesma. Materiais e Método: Sessenta barras cerâmicas foram fabricadas com o sistema Emax Press (Ivoclar Vivadent) com diferentes espessuras: G1)2 mm; G2) 0,7 mm; G3) 0,5 mm; G4) 0,4 mm; G5) 0,3 mm; G6) 0,2mm. Sessenta incisivos centrais superiores bovinos com dimensões semelhantes recém extraídos, foram selecionados. Quarenta e cinco dentes foram aleatoriamente selecionados para serem restaurados com facetas cerâmicas (n=15), com variação da espessura da restauração, formando os seguintes grupos: G1: 0,7 mm; G2: 0,5 mm e G3: 0,3 mm, além de 15 dentes não restaurados (G4 - controle). As amostras foram então submetidas ao teste de resistência flexural e à fratura em uma máquina de ensaios universal (Instron 4444). As médias dos grupos foram comparadas por meio de uma Análise de Variância, um critério(a=0,05). O teste de comparações múltiplas de HSD de Tukey foi utilizado como teste post-hoc, para verificar diferença entre os grupos. Resultados: A resistência flexural do grupo G6 (0,2 mm) foi a única estatisticamente inferior aos demais grupos. Os resultados de resistência à fratura demonstraram que não houve diferença estatística entre os grupos estudados. Conclusão: A espessura cerâmica influencia nos valores de resistência flexural quando a espessura for de 0,2 mm e as diferentes espessuras cerâmicas testadas não influenciaram nos valores de resistência à fratura.<br> / Abstract: Objective: To evaluate the fracture resistance in bovine teeth, veneers ceramics of different thickness and the influence of the thickness of a ceramic-based lithium disilicate on the flexural strength of it. Materials and Methods: Sixty ceramic bars were manufactured in Emax Press system (Ivoclar Vivadent) with different thicknesses: G1) 2 mm;G2) 0.7 mm; G3) 0.5 mm; G4) 0.4 mm; G5) 0.3 mm; G6) 0.2 mm. Sixty bovine central incisors with similar dimensions newly extracted, were selected. Forty-five teeth were randomly selected to be restored with ceramic veneers (n = 15), varying the thickness of the restoration, forming the following groups: G1: 0.7 mm; G2: 0.5 mm G3: 0.3 mm, and15 teeth not restored (G4 - control). The samples were then subjected to flexural strength and fracture toughness test in a universal testing machine (Instron 4444). The means of groups were compared by means of an Analysis of Variance one criterion (a = 0.05). The multiple comparison test of Tukey HSD was used as post-hoc test to verify differences between groups. Results: The flexural strength of the G6 (0.2 mm) group was the only statistically inferior to other groups. The results of fracture toughness showed no statistical difference between groups. Conclusion: The ceramic thickness influences the values of flexural strength when the thickness is 0.2 mm and different ceramic thicknesses tested did not influence the values of fracture resistance.
3

Influência da coloração do substrato, espessura e translucidez da cerâmica na cor de facetas laminadas produzidas com o sistema CEREC inLab

Hilgert, Leandro Augusto January 2009 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-24T08:59:38Z (GMT). No. of bitstreams: 1 268353.pdf: 3288334 bytes, checksum: ff1e19404dfabc735e020224a39b7578 (MD5) / O objetivo deste estudo in vitro foi investigar, espectrofotométrica e visualmente, a cor de facetas produzidas com um sistema CAD/CAM, com diferentes níveis de descoloração de substrato, espessuras de material e graus de translucidez das cerâmicas. Para isso, incisivos centrais superiores esquerdos de um modelo dental acrílico foram preparados para facetas com 0,4, 0,7 e 1,00mm de desgaste axial. Esses foram replicados em três diferentes colorações que simulavam substratos normal, escurecido e severamente escurecido. As facetas cerâmicas foram produzidas com o sistema CEREC inLab pelo método de correlação à anatomia hígida para cada tipo de preparo, com blocos dos materiais EmpressCAD HT (HT), EmpressCAD LT (LT) e EmpressCAD Multi (MU) e e.maxCAD HT (EH). Todas as restaurações receberam caracterização extrínseca e glazeamento padronizados. A união das facetas aos preparos foi simulada com um gel try-in padrão. As diferentes combinações de profundidade e preparo, coloração do substrato e cerâmica foram estandardizadamente fotografadas e tiveram sua cor mensurada por um espectrofotômetro clínico. As coordenadas de cor (CIELAB) instrumentalmente mensuradas foram comparadas às de uma restauração-referência (preparo normal, 0,7mm de espessura e cerâmica HT), para a determinação da diferença de cor (?E). As fotografias foram analisadas por 7 avaliadores que determinaram se a diferença de cor entre espécimes e restauração-padrão era aceitável ou inaceitável. Os resultados das análises espectrofotométrica e visual permitiram estabelecer um limite de aceitabilidade de diferença de cor para o estudo igual a ?E=3,3. Substratos normais foram restaurados de maneira aceitável com preparos conservadores (0,4mm) e cerâmicas translúcidas (HT, EH e MU). Substratos escurecidos obtiveram bons resultados com 0,4mm de espessura e cerâmica LT ou 0,7mm e cerâmicas MU e LT. O escurecimento severo só foi mascarado adequadamente com espessura de 1,0mm e cerâmica LT. Cor do substrato, espessura e grau de translucidez da cerâmica afetam significativamente a cor final de facetas laminadas. Cerâmicas menos translúcidas e preparos mais invasivos colaboram no poder de mascaramento das facetas sobre substratos escurecidos. / The aim of this study was evaluating, spectrophotometric- and visually, the color of veneers fabricated by a CAD/CAM system, with different levels of stump discoloration, material thickness and translucency degrees of the ceramics. Acrylic upper-left central incisors of a dental model received veneer preparations with 0.4, 0.7 or 1.0mm of axial reduction and were reproduced in three different levels of discoloration, simulating normal, discolored and severely discolored stump shades. The ceramic veneers were produced by the CEREC inLab system using correlation mode. Milling blocks used were EmpressCAD HT (HT), EmpressCAD LT (LT), EmpressCAD Multi (MU) and e.maxCAD HT (EH). All restorations were standardly stained and glazed. Cementation was simulated with a standard try-in paste. The different combinations of preparation depth, stump shade and ceramic translucency degree were standardly photographed and analyzed by a clinical spectrophotometer. The measured CIELAB coordinates were compared to a reference-restoration (normal stump shade, 0.7mm thickness and HT ceramic) to determine de color difference (?E). The photographs were analyzed by seven observers that judged the color difference between test-specimens and reference-restoration acceptable or not. Results from instrumental and visual analysis allowed an acceptability threshold of ?E=3,3 to be determined for this study. Normal stump shades were acceptably restored with conservative preparations (0.4mm) and translucent ceramics (HT, MU and EH). Discolored stumps presented good results with 0.4mm/LT, and 0.7mm/MU or 0.7mm/LT. Severe discoloration was only masked by 1.0mm preparation and LT. Stump shade, thickness and translucency degree of the ceramic significantly affect the final color of laminate veneers. Less translucent ceramics and more invasive preparations increase the masking power of veneers on discolored substrates.
4

Avaliação da resistência à fratura de facetas estéticas minimamente invasivas de dissilicato de lítio e de resina composta

Linhares, Ludmilla de Azevedo January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014. / Made available in DSpace on 2014-08-06T17:57:52Z (GMT). No. of bitstreams: 1 326900.pdf: 8838308 bytes, checksum: 673364846f5df6dc38ef1a6027e5fcd7 (MD5) Previous issue date: 2014 / O objetivo deste trabalho foi comparar técnicas restauradoras em facetas estéticas com formas diferentes de preparo (técnicas indireta com cerâmica e direta com resina composta). Quarenta pré-molares hígidos foram divididos em 4 grupos (n=10): G1-grupo controle - sem preparo, restauração tipo faceta direta de resina composta, estendendo-se por toda a face vestibular e envolvendo 1mm da cúspide vestibular tendo 0,2mm de espessura na vestibular e oclusal, G2-grupo sem preparo, facetas de porcelana com 0,2mm de dissilicato de lítio, estendendo-se por toda a face vestibular e envolvendo 1mm da cúspide vestibular tendo 0,2mm de espessura na vestibular e oclusal; G3-grupo com preparo de 0,2 mm de profundidade e redução oclusal de 0,2 mm, facetas de porcelana com 0,2 mm de dissilicato de lítio, estendendo-se por toda a face vestibular e envolvendo 1 mm da cúspide vestibular tendo 0,2 mm de espessura na vestibular e oclusal; G4- grupo com preparo de 0,5 mm de profundidade e redução oclusal de 0,5 mm, facetas de porcelana com 0,5 mm de dissilicato de lítio estendendo-se por toda a face vestibular e envolvendo 1 mm da cúspide vestibular tendo 0,5 mm de espessura na vestibular e oclusal. Os elementos dentais foram preparados e, posteriormente, moldados para confecção das peças cerâmicas. Com estas peças finalizadas, os tratamentos da superfície interna da cerâmica como do elemento dental foram realizados, para que pudessem ser cimentados. O passo seguinte à cimentação adesiva foi a termociclagem, com cerca de 10.000 ciclos, dos corpos de prova. Após, as amostras foram submetidas ao teste de resistência à fratura sob compressão, onde houve a fixação em uma máquina de ensaio universal 4444 (Instron, EUA), sendo a máquina regulada à velocidade de 0,5mm/min., no sentido perpendicular à superfície do laminado cerâmico / resina composta, até a fratura, completa ou parcial, das amostras. A força necessária para a fratura, em Newton (N), de cada corpo de prova foi anotada e submetida à ANOVA+ Teste post hoc de Duncan (p < 0,05). A análise estatística demonstrou que houve diferenças entre os grupos (p <0,05). As médias de resistência à fratura foram: G1 = 690,33 ± 233a; G2 = 790,52 ± 408a; G3 = 1131,34 ± 341b; G4 = 983,56 ± 202ab. Os grupos G1 e G2 apresentaram uma resistência à fratura significativamente menor que G3 (p = 0,05). Enquanto G4 apresentou valor intermediário que não diferiu estatisticamente tanto de G3 como de G1 e G2. Concluindo que facetas de cerâmica com preparo e espessura de 0,2 mm apresentam alta resistência à fratura.
5

Efeito da translucidez da pastilha cerâmica na sorção de água e solubilidade de diferentes agentes de cimentação

Leal, Clara Lemos Nunes January 2013 (has links)
Submitted by Edileide Reis (leyde-landy@hotmail.com) on 2015-04-14T22:24:13Z No. of bitstreams: 1 CLARA LEMOS NUNES LEAL.pdf: 3268070 bytes, checksum: 969c5dadb96951cfa703f1cd3286cb2d (MD5) / Made available in DSpace on 2015-04-14T22:24:13Z (GMT). No. of bitstreams: 1 CLARA LEMOS NUNES LEAL.pdf: 3268070 bytes, checksum: 969c5dadb96951cfa703f1cd3286cb2d (MD5) Previous issue date: 2013 / Os novos padrões de beleza tornam o sorriso um dos fatores fundamentais de convívio social. Nesse sentido, a Odontologia estética vem utilizando cada vez mais os laminados cerâmicos, que possibilitam resultados satisfatórios com mínimo desgaste dental. O objetivo deste trabalho é realizar uma revisão de literatura sobre laminados cerâmicos, suas indicações, uso, além da cimentação adesiva. Diante da literatura revisada, observou-se que a escolha da cerâmica deve ser realizada de maneira criteriosa, sendo as de dissilicato de lítio mais comumente indicadas atualmente. Verifica-se também a necessidade da realização de preparos cuidadosos, ângulos arredondados, em espessuras que variem de acordo com as necessidades individuais, especialmente pela possível interferência da cor do substrato dentário sobre o resultado final. Finalmente, dada a íntima relação entre a fixação adesiva e a durabilidade dos laminados cerâmicos, ressalta-se o cuidado necessário na escolha e aplicação dos agentes de cimentação resinosa, sua polimerização adequada, bem como preparo da superfície cerâmica e da estrutura dental, o que possibilita, de acordo com estudos, melhoria nas propriedades mecânicas desse conjunto.
6

O impacto do preparo, da cerâmica e do contato oclusal na distribuição de tensões em facetas

Meirelles, Laura Célia Fernandes [UNESP] 02 December 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:36Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-12-02. Added 1 bitstream(s) on 2015-09-17T15:47:32Z : No. of bitstreams: 1 000843143.pdf: 1842870 bytes, checksum: 17eef18d8303e51e77d82360b9f3de64 (MD5) / O objetivo do estudo foi verificar a distribuição de tensões nas facetas cerâmicas confeccionadas com dois tipos de material: feldspato e dissilicato de lítio em quatro diferentes tipos de preparos limitados ao esmalte dental: (1) vestibular; (2) vestibular com redução incisal; (3) vestibular com cobertura incisal e (4) estendido, em duas situações oclusais: carga aplicada no terço incisal e no terço médio palatino, obtidas por meio de análise por elementos finitos. Os modelos tridimensionais foram realizados no software CAD Rhinoceros 4.0® utilizando um arquivo stl (estereolitografia) de um incisivo central superior, com dimensões médias encontradas na literatura, onde foram simuladas as condições utilizadas para realização de um teste experimental. Os modelos foram compostos por esmalte, dentina, polpa, poliéter (para simular ligamento periodontal), cerâmica e base e foram submetidos a cargas de 100 N sob angulação de 45º em relação ao plano oclusal. O pré-processamento e pós-processamento foram realizados pelo programa de elementos finitos Ansys® v.13.0. Os resultados foram apresentados em gráficos de tensão máxima principal, com seus respectivos valores numéricos representados em escala de cores. A análise de elementos finitos mostrou que os desenhos mais conservadores apresentaram uma melhor distribuição de tensão nos laminados cerâmicos de dissilicato de lítio em comparação à cerâmica feldspática, no entanto, a mais alta concentração de tensão foi encontrada nas facetas desse mesmo material no grupo estendido quando submetido à carga no terço médio palatino. O tipo do contato oclusal causou diferente distribuição de tensão entre os diferentes tipos de preparos, sendo que, o contato incisal promoveu uma maior concentração de tensão nas facetas realizadas com ambos materiais exceto no preparo estendido confeccionado com a porcelana de dissilicato de lítio / The purpose of this study was to verify the stress distribution in the ceramic veneers made with two types of porcelain: feldspathic and lithium disilicate in four different design types limited to dental enamel:(1) buccal preparation, (2) buccal preparation with incisal reduction, (3) buccal preparation with coverage incisal and (4) extended preparation in two different occlusal situations: load on the incisal third and the middle third palatine, through mathematical finite element method. Three-dimensional CAD models were performed in CAD Rhinoceros 4.0® using a stl file of a maxillary central incisor with average dimensions found in the literature, where conditions used for conducting an experimental test. The models were composed of enamel, dentin, pulp, polyether (to simulate the periodontal ligament), and ceramic base and underwent loads of 100 N under an angle of 45 degrees to the occlusal plane in the incisal and middle thirds of the palatal tooth region. Preprocessing and post processing by ANSYS® version 13.0 finite element program were performed. The results were presented in plots by principal maximum stress with their respective numerical values represented by the color scale. The finite element analysis showed that for the most conservative designs present a better stress distribution on veneers of lithium disilicate, nevertheless, the higher tensile stresses concentrations were found on veneers of same material for group subjected to palatal chamfer design when subjected to load in the middle third palate. The type of occlusal contact contact caused different distribution of tension among the different types of preparations design, and the incisal contact promoted higher stress concentration in both facets except the extended preparation performed with porcelain lithium disilicate
7

O impacto do preparo, da cerâmica e do contato oclusal na distribuição de tensões em facetas /

Meirelles, Laura Célia Fernandes. January 2014 (has links)
Orientador: Clovis Pagani / Co-orientador: Alexandre Luiz Souto Borges / Banca: Eduardo Bresciani / Banca: Eron Toshio Colato Yamamoto / Resumo: O objetivo do estudo foi verificar a distribuição de tensões nas facetas cerâmicas confeccionadas com dois tipos de material: feldspato e dissilicato de lítio em quatro diferentes tipos de preparos limitados ao esmalte dental: (1) vestibular; (2) vestibular com redução incisal; (3) vestibular com cobertura incisal e (4) estendido, em duas situações oclusais: carga aplicada no terço incisal e no terço médio palatino, obtidas por meio de análise por elementos finitos. Os modelos tridimensionais foram realizados no software CAD Rhinoceros 4.0® utilizando um arquivo stl (estereolitografia) de um incisivo central superior, com dimensões médias encontradas na literatura, onde foram simuladas as condições utilizadas para realização de um teste experimental. Os modelos foram compostos por esmalte, dentina, polpa, poliéter (para simular ligamento periodontal), cerâmica e base e foram submetidos a cargas de 100 N sob angulação de 45º em relação ao plano oclusal. O pré-processamento e pós-processamento foram realizados pelo programa de elementos finitos Ansys® v.13.0. Os resultados foram apresentados em gráficos de tensão máxima principal, com seus respectivos valores numéricos representados em escala de cores. A análise de elementos finitos mostrou que os desenhos mais conservadores apresentaram uma melhor distribuição de tensão nos laminados cerâmicos de dissilicato de lítio em comparação à cerâmica feldspática, no entanto, a mais alta concentração de tensão foi encontrada nas facetas desse mesmo material no grupo estendido quando submetido à carga no terço médio palatino. O tipo do contato oclusal causou diferente distribuição de tensão entre os diferentes tipos de preparos, sendo que, o contato incisal promoveu uma maior concentração de tensão nas facetas realizadas com ambos materiais exceto no preparo estendido confeccionado com a porcelana de dissilicato de lítio / Abstract: The purpose of this study was to verify the stress distribution in the ceramic veneers made with two types of porcelain: feldspathic and lithium disilicate in four different design types limited to dental enamel:(1) buccal preparation, (2) buccal preparation with incisal reduction, (3) buccal preparation with coverage incisal and (4) extended preparation in two different occlusal situations: load on the incisal third and the middle third palatine, through mathematical finite element method. Three-dimensional CAD models were performed in CAD Rhinoceros 4.0® using a stl file of a maxillary central incisor with average dimensions found in the literature, where conditions used for conducting an experimental test. The models were composed of enamel, dentin, pulp, polyether (to simulate the periodontal ligament), and ceramic base and underwent loads of 100 N under an angle of 45 degrees to the occlusal plane in the incisal and middle thirds of the palatal tooth region. Preprocessing and post processing by ANSYS® version 13.0 finite element program were performed. The results were presented in plots by principal maximum stress with their respective numerical values represented by the color scale. The finite element analysis showed that for the most conservative designs present a better stress distribution on veneers of lithium disilicate, nevertheless, the higher tensile stresses concentrations were found on veneers of same material for group subjected to palatal chamfer design when subjected to load in the middle third palate. The type of occlusal contact contact caused different distribution of tension among the different types of preparations design, and the incisal contact promoted higher stress concentration in both facets except the extended preparation performed with porcelain lithium disilicate / Mestre
8

Influência do contorno axial de laminados cerâmicos, sem término cervical, sobre o comportamento da margem gengival : estudo clínico prospectivo /

Araujo, Nara Santos. January 2016 (has links)
Orientador: Eduardo Passos Rocha / Coorientador Renato Herman Sundfeld / Banca: Paulo Henrique dos Santos / Banca: Rodolfo Bruniera Anchieta / Resumo: Objetivo: Avaliar, a través de um estudo clínico prospectivo, a influência de laminados cerâmicos, cimentado s sobre dentes sem a realiza ção d o término cervic al, sobre o comportamento da margem gengival. Materiais e Métodos : Setenta dentes restaurados com laminados cerâmicos foram avaliado s . Dentes vizinhos ou antagonistas não restaurados f oram utilizados como controle. O s fator es de estudo fo ram o tratamento r ealizado, o biótipo gengival e o tempo de análise (T) em 7 níveis [ T0 (previamente ao tratamento), T 7 ( 7 dias após cimentação), T1 5 (15 dias), T 30 (30 dias), T 60 (60 dias), T 120 (120 dias), e T 180 (180 dias após cimentação). As variáveis de resposta foram o índice gengival (IG), o índice de placa (IP) e a recessão gengival, recebendo escores, de forma qualitativa e decrescente ( Alfa, Beta, Charlie e Delta ), segundo a condição clínica . Fotografias digitais foram obtidas em cada tempo de análise. Resultado s : A análise dos grupos restaura do e controle mostrou maior prevalência de elementos conceituados "A lfa " para as variáveis IG e IP. Meno s registros em "B eta ' e "C harlie " foram observados no grupo restaurado, demostrando com isso um menor acúmulo de placa nas superfícies restauradas. O sobreconto rno horizontal nos dentes restaura dos não aumentou a ocorrência de inflamação na margem gengival em relação ao grupo controle, e 100% da amostra não apresentou recessão gengival após 180 dias de acompanhamento clínico. Conclus ão : Com base nos resultad os obtidos, observa - se que a presença de sobrecontorno horizontal nos dentes restaurados não alterou o posicionamento vertical da margem gengival e não ocasionou inflamação periodontal clinicamente perceptível . O biótipo ge ngival não influenciou nos resultados. / Abstract:Purpose : To evaluate, through a prospective clinical study, the influence of ceramic veneers, cemented on teeth without cervical finish line, on the be havior of the gingival margin Materials and Methods : Seventy teeth with ceramic laminate veneers were evaluated . Neighboring unrestored teeth were used as control. The study factors were the treatment, the gingival biotype and the time analysis (T) on 7 le vels [T0 ( prior to treatment ), T7 (7 days after cementation), T1 5 (15 days), T 30 (30 days), T 60 (60 days) T 12 0 (120 days), and T 180 (180 days after cementation)] . The response variables were gingival index (GI), plaque index (PI), and gingival recession, g etting scores (Alfa, Beta, Charlie and Delta), according to the clinical condition . Digital photographs were taken in each time. Results: The analysis of the restored and control groups showed a higher prevale nce of reputable elements "Alfa" for GI and PI variables . Lower records in "Beta" and "Charlie" were observ ed in the restored group, showing less plaque build - up in the restored surfaces . The horizontal overcontouring of restorations, did not increase the occurrence of inflammation of the gingival margin in the restored group compared to the control group, and 100% of the sample obtained concept "Alfa" to the variable gingival recession after 180 days of clinical follow - up . Conclusion : The presence of horiz ontal overcontouring did not change the vertical position of the gingival margin and did not cause a clinically perceptible periodontal inflammation. The gingival biotype did not influence the results. / Mestre
9

Avaliação da estabilidade de cor e capacidade de mascaramento de facetas com cerâmicas reforçadas por dissilicato de lítio e cerâmicas híbridas / Evaluation of color stability and masking ability of ceramics reinforced by lithium disilicate and hybrid ceramics veneers

Rodrigues, Raphaela Farias 29 June 2017 (has links)
Os objetivos deste trabalho foram avaliar a estabilidade de cor e capacidade de mascaramento até 1.000.000 de ciclos termomecânicos das facetas de cerâmica híbrida e cerâmica reforçada com dissilicato de lítio processadas pelo método de fresagem CAD/CAM; verificar a influência da cor do cimento em relação a cor final das facetas e a correspondência entre as pastas try-in; e as respectivas cores dos cimentos. Foram confeccionadas 60 facetas cerâmicas, pelo método de fresagem, que foram cimentadas com cimento fotopolimerizável (Variolink Esthetic LC), seguindo as orientações dos fabricantes, em réplicas de incisivos centrais escurecidos (C4) e não escurecidos (A2) e distribuídas nos grupos experimentais (n=10) DA2N, DC4N, DC4L, HA2N, HC4N, HC4L de acordo com o tipo de cerâmica dissilicato de lítio (D) e híbrida (H), cor do substrato A2 e C4, e cor do cimento neutral (N) e ligth (L). As leituras com espectrofotômetro foram realizadas previamente à cimentação das facetas, facetas + pastas Try-In, imediatamente após cimentação da faceta, após 48h, 72h e após ciclos termomecânicos (250.000, 500.000, 750.000 e 1.000.000) em máquina de ciclagem. Os dados foram analisados pelo teste ANOVA-2 medidas repetidas e teste Tukey (5%). Observou-se que ambas as cerâmicas apresentaram estabilidade de cor e capacidade de mascaramento, pois apesar de ocorrer diferença estatística em alguns grupos, todos os valores de E apresentaram-se abaixo de 1,7, ou seja, não são perceptíveis. Da mesma forma, verificou-se que a cor dos cimentos (neutral e light) não influenciou na cor final das restaurações, pois não houve diferença estatística significante comparando-se os grupos DC4N e DC4L como também entre HC4N e HC4L. Correlacionando-se as pastas try-in com as cores dos respectivos cimentos todos os valores obtidos para E ficaram abaixo de 3,3 que é considerado o limite como perceptível por observadores não treinados. Concluiu-se que as facetas de cerâmica híbrida e dissilicato de lítio apresentam muito boa estabilidade de cor ao longo do tempo e capacidade de mascaramento. Assim como, as diferentes cores de cimento não influenciam a cor final das facetas e as pastas try-in apresentam fidelidade em relação às respectivas cores dos cimentos. / The objectives of this work were to evaluate the color stability and masking ability up to 1,000,000 thermomechanical cycles of hybrid and reinforced with lithium disilicate ceramics processed by the CAD/CAM method; to verify the influence of cement color in relation to the final color of the veneers; and the correspondence between try-in and respective colors of the cements. 60 ceramic veneers were prepared using the milling method, which were cemented by light-curing cement (Variolink Esthetic LC) according to the manufacturer\'s instructions on replicates of darkened (C4) and nondarkened central incisors (A2) and distributed in the experimental groups (n=10) - DA2N, DC4N (D), DC4L, HA2N, HC4N, HC4L according to ceramic - lithium disilicate (D) and hybrid (H), substrate color - A2 and C4, and cement color - neutral (N) and ligth (L). The spectrophotometer measurements were performed prior to veneers cementation, veneers + try-In, immediately after cementing, after 48h, 72h and after thermomechanical cycles (250,000, 500,000, 750,000 and 1,000,000) in a cycling machine. Data were analyzed by ANOVA-2 repeated measures and Tukey test (5%). It was observed that both ceramics presented color stability and masking ability, because although there was a statistical difference in some groups, all values of E were below 1.7, ie, they are not perceptible. Likewise, it was found that the color of the cements (neutral and light) did not influence the final color of the restorations, since there was no significant statistical difference comparing the groups DC4N and DC4L as well as between HC4N and HC4L. By correlating the tryin with the colors of the respective cements all values obtained for E were below 3.3 which is considered the limit as perceived by untrained observers. It was concluded that hybrid ceramics and lithium disilicate veneers exhibit very good color stability over time and masking ability. As well as, the different cement colors do not influence the final color of the veneers and try-in pastes show similarity to the respective colors of the cements.
10

Influ?ncia da espessura e grau de translucidez dos materiais nanocer?micos utilizados em CAD/CAM e do tipo de cimento na cor final de facetas

Peixoto, Maur?cio Tomazoni 13 December 2016 (has links)
Submitted by Caroline Xavier (caroline.xavier@pucrs.br) on 2017-05-23T17:30:49Z No. of bitstreams: 1 DIS_MAURICIO_TOMAZONI_PEIXOTO_COMPLETO.pdf: 977170 bytes, checksum: 550fe78287feca797929ac42cf3a7c9c (MD5) / Made available in DSpace on 2017-05-23T17:30:49Z (GMT). No. of bitstreams: 1 DIS_MAURICIO_TOMAZONI_PEIXOTO_COMPLETO.pdf: 977170 bytes, checksum: 550fe78287feca797929ac42cf3a7c9c (MD5) Previous issue date: 2016-12-13 / Conselho Nacional de Pesquisa e Desenvolvimento Cient?fico e Tecnol?gico - CNPq / The increasing demand for aesthetic restorations, associated with the evolution of techniques and materials, allowed the preparation of prosthetic pieces of reduced thickness. The introduction of CAD / CAM technology has made accurate and fast restorations. However, the final color of the restoration remains the direct responsibility of the dentist, where a visual assessment of color can cause errors, while an instrumental color measurement has accurate readings. The objective of the study was to investigate the factors that may influence the final color and translucency of different veneers with different thicknesses made by CAD/CAM materials and different types of resin cements on a darkened substrate. The samples were made by copy biogeneric in the CEREC SW 4.2 system, after a sample calculation of the pilot project, 60 upper central incisors of the right side of color C3 of epoxy resin were selected in 12 groups of 5 elements, divided according to type of (Lava Ultimate HT and LT), facet thickness (0.3mm / 0.6mm / 1.0mm) and cement type (Relyx Ultimate and Relyx Veneer). After cementation, the samples were taken with the spectrophotometer at a value of ?E in 6 different times with a silicone guide on the tooth, which ensures that the color is uniform. The results showed a significant difference in the values of ?E in groups 1 and 4 (HT and LT of 0.3 mm) cemented with Relyx Ultimate, in groups 7 and 9 (HT of 0.3 mm and 1.0 mm), and in groups 10 And 12 (LT of 0.3mm and 1.0mm) cemented with Relyx Veneer. However, the results were not significant for the masking of the darkened substrate over time, however, significant differences in ?E values were. / A crescente demanda por restaura??es est?ticas, associada a evolu??o das t?cnicas e materiais, possibilitaram a confec??o de pe?as prot?ticas de espessuras reduzidas. A introdu??o da tecnologia CAD/CAM possibilitou a realiza??o de restaura??es precisas e exatas rapidamente. No entanto, a cor final da restaura??o continua sendo responsabilidade direta do dentista, onde uma avalia??o visual de cor pode ocasionar erros, enquanto uma medi??o de cor instrumental possui leituras precisas. O objetivo do estudo foi realizar uma investiga??o dos fatores que podem influenciar a cor final e translucidez de facetas com diferentes espessuras confeccionadas por materiais CAD/CAM e diferentes tipos de cimentos resinosos sobre um substrato escurecido. As amostras foram confeccionadas por c?pia biogen?rica no sistema CEREC SW 4.2, ap?s c?lculo amostral do projeto piloto, foram selecionados 60 incisivos centrais superiores do lado direito de cor C3 de resina ep?xi foram divididos em 12 grupos de 5 elementos, divididos de acordo com tipo de material (Lava Ultimate HT e LT), espessura da faceta (0,3mm/ 0,6mm/ 1,0mm) e tipo de cimento (Relyx Ultimate e Relyx Veneer). Ap?s a cimenta??o, realizou-se a tomada de cor das amostras com o espectrofot?metro pelo valor de ?E em 6 tempos distintos com uma guia de silicone sobre o dente, que garante que a tomada de cor seja uniforme. Os resultados mostraram diferen?a significativa nos valores de ?E nos grupos 1 e 4 (HT e LT de 0,3mm) cimentados com Relyx Ultimate, nos grupos 7 e 9 (HT de 0,3mm e 1,0mm), e nos grupos 10 e 12 (LT de 0,3mm e 1,0mm) cimentados com Relyx Veneer. Entretanto os resultados n?o foram significativos quanto ao mascaramento do substrato escurecido ao longo do tempo, entretanto, foram observadas diferen?as significativas nos valores de ?E ao longo do tempo em uma an?lise intra-grupos.

Page generated in 0.0496 seconds