• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeitos do ultra-som pulsado de baixa intensidade em um modelo ósseo de ratas ovarectomizadas analisados por meio do ensaio de flexo-compressão / Low-intensity pulsed ultrasound effects on a bone pattern of ovariectomized female rats analyzed through flexion-compression test

Kodama, Ana Cristina 10 November 2003 (has links)
O osso é um tecido dinâmico que remodela em resposta a um estímulo mecânico aplicado. O ultra-som pulsado de baixa intensidade consiste da propagação de ondas de energia mecânica e o propósito desta investigação foi analisar seus efeitos em um modelo ósseo de ratas ovarectomizadas por meio do ensaio de flexo-compressão. O estudo foi composto por 28 ratas Wistar, com peso médio de 251,4 gramas. Os animais foram divididos em 3 grupos: 10 animais ovarectomizados, tratados com ultra-som (grupo tratado), 9 animais ovarectomizados para controle (grupo ovarectomizado) e 9 animais intactos que não sofreram nenhum tipo de intervenção (grupo intacto). No grupo tratado as aplicações do ultra-som foram iniciadas no primeiro dia após a cirurgia de ovarectomia, extendendo-se por 9 semanas, 6 dias por semana, durante 20 minutos diários. Por meio do ensaio de flexo-compressão, realizado na extremidade proximal dos fêmures, foi avaliado o limite máximo. A deformação do limite máximo não foi alterada nos diferentes grupos. No entanto, a média da carga do limite máximo do grupo ovarectomizado foi significativamente menor quando comparada com os grupos intacto e tratado, e entre os grupos intacto e tratado as médias não foram estatisticamente diferentes, sugerindo que apesar do grupo tratado também ter sido submetido à ovarectomia, a média da carga do limite máximo foi semelhante à do grupo intacto pela influência do ultra-som. Estes resultados fornecem indícios de que a perda de massa óssea provocou diminuição da carga do limite máximo e que a estimulação com ultra-som pulsado de baixa intensidade em fêmures de ratas ovarectomizadas contribuiu na preservação deste parâmetro mecânico / Bone is a dynamic tissue, which remodels to applied mechanical stimuli. The low-intensity pulsed ultrasound consists on the propagation of waves of mechanical energy and the motivation of this study was to analyze its effects on a ovariectomized female rat bone model through flexion-compression test. The study was carried out with 28 female Wistar rats with 251,4 grams average weight. The animals were divided in 3 groups: 10 ovariectomized rats exposed to ultrasound (treated animals), 9 control ovariectomized animals (ovariectomized group) and 9 intact animals that did not suffer any kind of intervention (intact group). In the treated group, the ultrasound exposition was initiated on the first day after the surgery, and it was extended for 9 weeks, 6 days per week, during 20 minutes per day. Through the flexion-compression test, carried out on the femur’s proximal extremity, the maximum limit was evaluated. The maximum limit deformation wasn’t altered in these different groups. Though, the maximum limit load average in the ovariectomized group was significantly lower when compared to the intact and treated groups, and between the intact and treated groups, the average wasn’t statistically different, suggesting that despite of the treated group was submitted to ovariectomy, the average value of the load maximum limit was similar to the intact group by the ultrasound influence. These results were indications that the loss of bone mass caused the load maximum limit decreasing and that the low-intensity pulsed ultrasound stimulation on femurs of ovariectomized female rats contributed to the preservation of this mechanical parameter
2

Efeitos do ultra-som pulsado de baixa intensidade em um modelo ósseo de ratas ovarectomizadas analisados por meio do ensaio de flexo-compressão / Low-intensity pulsed ultrasound effects on a bone pattern of ovariectomized female rats analyzed through flexion-compression test

Ana Cristina Kodama 10 November 2003 (has links)
O osso é um tecido dinâmico que remodela em resposta a um estímulo mecânico aplicado. O ultra-som pulsado de baixa intensidade consiste da propagação de ondas de energia mecânica e o propósito desta investigação foi analisar seus efeitos em um modelo ósseo de ratas ovarectomizadas por meio do ensaio de flexo-compressão. O estudo foi composto por 28 ratas Wistar, com peso médio de 251,4 gramas. Os animais foram divididos em 3 grupos: 10 animais ovarectomizados, tratados com ultra-som (grupo tratado), 9 animais ovarectomizados para controle (grupo ovarectomizado) e 9 animais intactos que não sofreram nenhum tipo de intervenção (grupo intacto). No grupo tratado as aplicações do ultra-som foram iniciadas no primeiro dia após a cirurgia de ovarectomia, extendendo-se por 9 semanas, 6 dias por semana, durante 20 minutos diários. Por meio do ensaio de flexo-compressão, realizado na extremidade proximal dos fêmures, foi avaliado o limite máximo. A deformação do limite máximo não foi alterada nos diferentes grupos. No entanto, a média da carga do limite máximo do grupo ovarectomizado foi significativamente menor quando comparada com os grupos intacto e tratado, e entre os grupos intacto e tratado as médias não foram estatisticamente diferentes, sugerindo que apesar do grupo tratado também ter sido submetido à ovarectomia, a média da carga do limite máximo foi semelhante à do grupo intacto pela influência do ultra-som. Estes resultados fornecem indícios de que a perda de massa óssea provocou diminuição da carga do limite máximo e que a estimulação com ultra-som pulsado de baixa intensidade em fêmures de ratas ovarectomizadas contribuiu na preservação deste parâmetro mecânico / Bone is a dynamic tissue, which remodels to applied mechanical stimuli. The low-intensity pulsed ultrasound consists on the propagation of waves of mechanical energy and the motivation of this study was to analyze its effects on a ovariectomized female rat bone model through flexion-compression test. The study was carried out with 28 female Wistar rats with 251,4 grams average weight. The animals were divided in 3 groups: 10 ovariectomized rats exposed to ultrasound (treated animals), 9 control ovariectomized animals (ovariectomized group) and 9 intact animals that did not suffer any kind of intervention (intact group). In the treated group, the ultrasound exposition was initiated on the first day after the surgery, and it was extended for 9 weeks, 6 days per week, during 20 minutes per day. Through the flexion-compression test, carried out on the femur’s proximal extremity, the maximum limit was evaluated. The maximum limit deformation wasn’t altered in these different groups. Though, the maximum limit load average in the ovariectomized group was significantly lower when compared to the intact and treated groups, and between the intact and treated groups, the average wasn’t statistically different, suggesting that despite of the treated group was submitted to ovariectomy, the average value of the load maximum limit was similar to the intact group by the ultrasound influence. These results were indications that the loss of bone mass caused the load maximum limit decreasing and that the low-intensity pulsed ultrasound stimulation on femurs of ovariectomized female rats contributed to the preservation of this mechanical parameter
3

Análise experimental de pilares de concreto armado submetidos à flexo-compressão, reforçados com concreto auto-adensável e conectores metálicos / Experimental analysis of reinforced concrete columns subjected to flexion-compression, reinforced with self-compacting concrete and metal connectors

Rocha, Anderson Souza 27 November 2015 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-03-09T18:17:57Z No. of bitstreams: 2 Dissertação - Anderson Souza Rocha - 2015.pdf: 7517938 bytes, checksum: 82b541aff42a5ea10a296bdc2f6c4074 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-03-10T12:04:55Z (GMT) No. of bitstreams: 2 Dissertação - Anderson Souza Rocha - 2015.pdf: 7517938 bytes, checksum: 82b541aff42a5ea10a296bdc2f6c4074 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-03-10T12:04:55Z (GMT). No. of bitstreams: 2 Dissertação - Anderson Souza Rocha - 2015.pdf: 7517938 bytes, checksum: 82b541aff42a5ea10a296bdc2f6c4074 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-11-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The proposed research is based on the study of reinforcement columms in reinforced concrete, with the use of anchor bolts and fill with self-compacting concrete, by jacketing. In addition to the experimental studies, numerical simulation was performed using a computer program based on the finite element method, took into account the breaking loads, displacements and deformations which allows a careful study of reinforced columms. The experimental part of this work was based on the test five columms of reinforced concrete, submitted to straight flexion-compression, in order to assess the bond interface between the concrete substrate and reinforcement of concrete and confirm the efficiency of this technique commonly used for reinforcement. Two columms were used as reference, one with the original abutment dimensions (Reference Columm, cross section: 120 x 250 mm) and the other monolithic concreted with the section of enhanced piece (Monolithic Columm, cross section: 155 x 250 mm). The others received a layer of 35 mm thick concrete in the compressed self-compacting face. The preparation of the interface between the two materials, it will be carried with the scarification boreholes along this surface, which anchors were inserted responsible for reinforcement of concrete bond with the substrate. It can be concluded on the work developed that not only the quantity but especially the location of the connectors used for the connection between the two materials, are essential for a good result of resistance and failure mode. Despite the studs do not present break, there was the peeling of the reinforcement layer. The results obtained indicate the possibility of using this method in the structural reinforcement columms rehabilitation, as it showed an increase in bearing capacity of about four times compared to the column of reference. The results of numerical simulation were very satisfactory, because the behavior of the columms in relation to tensile strength, displacements and deformations, approached the experimental results, with minor differences. / A pesquisa proposta se baseia no estudo do reforço de pilares em concreto armado, com emprego de chumbadores e preenchimento com concreto auto adensável, por encamisamento. Além do estudos experimentais, foi feita uma simulação numérica, utilizando um programa computacional baseado no Método dos Elementos Finitos, levou-se em consideração as cargas de ruptura, deslocamentos e deformações o que possibilita um estudo criterioso dos pilares reforçados. A etapa experimental deste trabalho foi embasada no ensaio de cinco pilares de concreto armado, submetidos à flexo-compressão reta, com intuito de avaliar a interface de ligação entre o concreto do substrato e concreto do reforço e confirmar a eficiência desta técnica usualmente utilizada para reforço. Dois pilares foram usados como referência, sendo um com as dimensões originais do pilar (Pilar de Referência, seção transversal: 120 x 250 mm) e o outro monolítico concretado com a seção de uma peça reforçada (Pilar Monolítico, seção transversal: 155 x 250 mm). Os demais receberam uma camada de 35 mm de espessura de concreto auto-adensável na face comprimida. O preparo da interface entre os dois materiais, proceder-se-á com a escarificação e realização de furos ao longo desta superfície, onde foram inseridos chumbadores responsáveis pela ligação do concreto do reforço com o substrato. Pode-se concluir em trabalhos desenvolvidos que não só a quantidade, mas principalmente, a localização dos conectores utilizados na ligação entre os dois materiais, são imprescindíveis para um bom resultado de resistência e modo de ruptura. Apesar dos chumbadores não apresentarem ruptura, houve o desplacamento da camada do reforço. Os resultados obtidos confirmam a possibilidade da utilização deste método de reforço na reabilitação estrutural de pilares, pois apresentou um aumento da capacidade portante em aproximadamente quatro vezes em relação ao pilar de referência. Os resultados da simulação numérica foram muito satisfatórios, pois o comportamento dos pilares, em relação a carga de ruptura, deslocamentos e deformações, aproximaram dos resultados experimentais, com pequenas diferenças.

Page generated in 0.1718 seconds