• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeitos do ultra-som pulsado de baixa intensidade em um modelo ósseo de ratas ovarectomizadas analisados por meio do ensaio de flexo-compressão / Low-intensity pulsed ultrasound effects on a bone pattern of ovariectomized female rats analyzed through flexion-compression test

Kodama, Ana Cristina 10 November 2003 (has links)
O osso é um tecido dinâmico que remodela em resposta a um estímulo mecânico aplicado. O ultra-som pulsado de baixa intensidade consiste da propagação de ondas de energia mecânica e o propósito desta investigação foi analisar seus efeitos em um modelo ósseo de ratas ovarectomizadas por meio do ensaio de flexo-compressão. O estudo foi composto por 28 ratas Wistar, com peso médio de 251,4 gramas. Os animais foram divididos em 3 grupos: 10 animais ovarectomizados, tratados com ultra-som (grupo tratado), 9 animais ovarectomizados para controle (grupo ovarectomizado) e 9 animais intactos que não sofreram nenhum tipo de intervenção (grupo intacto). No grupo tratado as aplicações do ultra-som foram iniciadas no primeiro dia após a cirurgia de ovarectomia, extendendo-se por 9 semanas, 6 dias por semana, durante 20 minutos diários. Por meio do ensaio de flexo-compressão, realizado na extremidade proximal dos fêmures, foi avaliado o limite máximo. A deformação do limite máximo não foi alterada nos diferentes grupos. No entanto, a média da carga do limite máximo do grupo ovarectomizado foi significativamente menor quando comparada com os grupos intacto e tratado, e entre os grupos intacto e tratado as médias não foram estatisticamente diferentes, sugerindo que apesar do grupo tratado também ter sido submetido à ovarectomia, a média da carga do limite máximo foi semelhante à do grupo intacto pela influência do ultra-som. Estes resultados fornecem indícios de que a perda de massa óssea provocou diminuição da carga do limite máximo e que a estimulação com ultra-som pulsado de baixa intensidade em fêmures de ratas ovarectomizadas contribuiu na preservação deste parâmetro mecânico / Bone is a dynamic tissue, which remodels to applied mechanical stimuli. The low-intensity pulsed ultrasound consists on the propagation of waves of mechanical energy and the motivation of this study was to analyze its effects on a ovariectomized female rat bone model through flexion-compression test. The study was carried out with 28 female Wistar rats with 251,4 grams average weight. The animals were divided in 3 groups: 10 ovariectomized rats exposed to ultrasound (treated animals), 9 control ovariectomized animals (ovariectomized group) and 9 intact animals that did not suffer any kind of intervention (intact group). In the treated group, the ultrasound exposition was initiated on the first day after the surgery, and it was extended for 9 weeks, 6 days per week, during 20 minutes per day. Through the flexion-compression test, carried out on the femur’s proximal extremity, the maximum limit was evaluated. The maximum limit deformation wasn’t altered in these different groups. Though, the maximum limit load average in the ovariectomized group was significantly lower when compared to the intact and treated groups, and between the intact and treated groups, the average wasn’t statistically different, suggesting that despite of the treated group was submitted to ovariectomy, the average value of the load maximum limit was similar to the intact group by the ultrasound influence. These results were indications that the loss of bone mass caused the load maximum limit decreasing and that the low-intensity pulsed ultrasound stimulation on femurs of ovariectomized female rats contributed to the preservation of this mechanical parameter
2

Efeitos do ultra-som pulsado de baixa intensidade em um modelo ósseo de ratas ovarectomizadas analisados por meio do ensaio de flexo-compressão / Low-intensity pulsed ultrasound effects on a bone pattern of ovariectomized female rats analyzed through flexion-compression test

Ana Cristina Kodama 10 November 2003 (has links)
O osso é um tecido dinâmico que remodela em resposta a um estímulo mecânico aplicado. O ultra-som pulsado de baixa intensidade consiste da propagação de ondas de energia mecânica e o propósito desta investigação foi analisar seus efeitos em um modelo ósseo de ratas ovarectomizadas por meio do ensaio de flexo-compressão. O estudo foi composto por 28 ratas Wistar, com peso médio de 251,4 gramas. Os animais foram divididos em 3 grupos: 10 animais ovarectomizados, tratados com ultra-som (grupo tratado), 9 animais ovarectomizados para controle (grupo ovarectomizado) e 9 animais intactos que não sofreram nenhum tipo de intervenção (grupo intacto). No grupo tratado as aplicações do ultra-som foram iniciadas no primeiro dia após a cirurgia de ovarectomia, extendendo-se por 9 semanas, 6 dias por semana, durante 20 minutos diários. Por meio do ensaio de flexo-compressão, realizado na extremidade proximal dos fêmures, foi avaliado o limite máximo. A deformação do limite máximo não foi alterada nos diferentes grupos. No entanto, a média da carga do limite máximo do grupo ovarectomizado foi significativamente menor quando comparada com os grupos intacto e tratado, e entre os grupos intacto e tratado as médias não foram estatisticamente diferentes, sugerindo que apesar do grupo tratado também ter sido submetido à ovarectomia, a média da carga do limite máximo foi semelhante à do grupo intacto pela influência do ultra-som. Estes resultados fornecem indícios de que a perda de massa óssea provocou diminuição da carga do limite máximo e que a estimulação com ultra-som pulsado de baixa intensidade em fêmures de ratas ovarectomizadas contribuiu na preservação deste parâmetro mecânico / Bone is a dynamic tissue, which remodels to applied mechanical stimuli. The low-intensity pulsed ultrasound consists on the propagation of waves of mechanical energy and the motivation of this study was to analyze its effects on a ovariectomized female rat bone model through flexion-compression test. The study was carried out with 28 female Wistar rats with 251,4 grams average weight. The animals were divided in 3 groups: 10 ovariectomized rats exposed to ultrasound (treated animals), 9 control ovariectomized animals (ovariectomized group) and 9 intact animals that did not suffer any kind of intervention (intact group). In the treated group, the ultrasound exposition was initiated on the first day after the surgery, and it was extended for 9 weeks, 6 days per week, during 20 minutes per day. Through the flexion-compression test, carried out on the femur’s proximal extremity, the maximum limit was evaluated. The maximum limit deformation wasn’t altered in these different groups. Though, the maximum limit load average in the ovariectomized group was significantly lower when compared to the intact and treated groups, and between the intact and treated groups, the average wasn’t statistically different, suggesting that despite of the treated group was submitted to ovariectomy, the average value of the load maximum limit was similar to the intact group by the ultrasound influence. These results were indications that the loss of bone mass caused the load maximum limit decreasing and that the low-intensity pulsed ultrasound stimulation on femurs of ovariectomized female rats contributed to the preservation of this mechanical parameter
3

Efeitos do laser de baixa intensidade e do Biosilicato® no reparo ósseo de ratas osteopênicas

Bossini, Paulo Sérgio 26 August 2010 (has links)
Made available in DSpace on 2016-06-02T20:18:13Z (GMT). No. of bitstreams: 1 3309.pdf: 4224881 bytes, checksum: 86928c516da5db9abcf5f60af6b27178 (MD5) Previous issue date: 2010-08-26 / Financiadora de Estudos e Projetos / Osteoporosis is a systemic skeletal disease characterized by low bone density and microarchitectural deterioration of bone tissue, with consequent increase of the risk of fractures. Frequently, the lower mineral density due to osteoporosis leads to a delay in fracture healing rates and bone repair quality. Within this context, biochemical and biophysical resources have been studied in an attempt to enhance bone consolidation. Two of the most promising treatments are the use of low level laser therapy (LLLT) and bioactive materials. Several studies suggest that both resources are able to stimulate osteoblast proliferation and osteogenesis at the fracture site, promoting a greater deposition of bone mass. Thus, two studies were performed with the aim of evaluating the effects of LLLT (Ga-Al-As, 830nm, 100mW), with the fluences of 60J/cm² and 120J/cm² and a bioactive ceramic (Biosilicate®), used alone or associated on consolidation of bone defects induced in the tibiae of osteopenic rats. A total of 60 female Wistar rats (12 weeks-old, ± 250g) were submitted to ovariectomy (OVX) and, sixty days after the induction, a bone defect was performed in both tibiae of all animals. The animals were randomly divided into six groups (n=10). In the first study, the effects of LLLT on the bone repair of osteopenic rats were evaluated in three groups: group bone defect control without any treatment (GC); group bone defect irradiated with LLLT, at 60J/cm² (GL60); and group bone defect irradiated with LLLT, at 120J/cm² (GL120). The animals were submitted to laser irradiation at a single point on the bone defect for seven sessions, on alternated days. In the laser treated groups, at both fluences, it was possible to observe a greater amount of new bone formation compared to the control. Birefringence analysis demonstrated that irradiated bone defects presented greater deposition and improved the structural organization of collagen fibers, mainly in the group treated with the laser, at 120J/cm². COX-2, CBFA-1 and VEGF immunoreactivity was detected in a similar manner either 60J/cm2 or 120J/cm2 fluences. However, no differences were observed in the biomechanical analysis. Therefore, the LLLT, at the two fluences used, improved the bone repair in the tibia of osteopenic rats. In the second study, the effects of Biosilicate® associated with LLLT on bone repair in osteopenic rats were analyzed in four groups: group bone defect control without any treatment (GC); group bone defect filled with Biosilicate® (GB); group bone defect filled with Biosilicate®, irradiated with LLLT, at 60J/cm2 (GBL60); and group bone defect filled with Biosilicate®, irradiated with LLLT, at 120J/cm2 (GBL120). Biosilicate® was used in the form of particles with granulometry of 180-212μm and the treated animals were irradiated with laser at a single point on the bone defect for seven sessions, on alternated days. The results demonstrated that the LLLT, with fluences of 60J/cm² and 120J/cm² stimulated the expression of COX-2 in the circumjacent cells of the biomaterial, increased of the collagen deposition and the biomechanical bone properties. Morphometric analysis revealed that the animals with bone defects filled with Biosilicate® and irradiated with laser, at 120J/cm² showed a higher amount of newly formed bone compared to the other groups. Thus, the LLLT, mainly in fluency 120J/cm² in contact with Biosilicate® improved the bone repair process in osteopenic rats. These findings are fundamental in elucidating the biological mechanisms involved in the repair of fractures with difficult consolidation, especially those associated with bone metabolic disease processes, such as osteoporosis. / A osteoporose é uma doença esquelética sistêmica caracterizada por baixa densidade óssea e deterioração da microarquitetura do tecido ósseo, com consequente aumento do risco de fraturas. Fraturas de difícil consolidação são comumente encontradas em pacientes osteoporóticos com altos índices de morbidade e mortalidade. Dentro desse contexto, recursos biofísicos e bioquímicos têm sido estudados na tentativa de minimizar o tempo de consolidação óssea, destacando-se o uso da terapia laser de baixa intensidade (LLLT) e dos materiais bioativos. Vários estudos sugerem que ambos os recursos são capazes de estimular a proliferação de osteoblastos e a osteogênese no local da fratura, promovendo uma maior deposição de massa óssea, fundamental para o processo de consolidação. Diante disso, foram realizados dois estudos com o objetivo de verificar os efeitos da LLLT (Ga-Al-As, 830nm, 100mW), nas fluências de 60J/cm² e 120J/cm² e de uma vitrocerâmica bioativa (Biosilicato®), utilizados independentemente ou associados, na consolidação de defeitos ósseos induzidos em tíbias de ratas osteopênicas. Um total de 60 ratas da linhagem Wistar (12 semanas de idade, ± 250g) foram submetidas à ovarectomia (OVX) e, sessenta dias após a indução, foi realizado um defeito ósseo em ambas as tíbias de todos os animais, os quais foram distribuídos aleatoriamente em seis grupos com dez animais cada. No primeiro estudo, foram avaliados os efeitos da LLLT sobre o reparo ósseo de ratas osteopênicas, a partir de três grupos experimentais: grupo controle com defeito ósseo sem tratamento (GC); grupo defeito ósseo tratado com laser 60J/cm² (GL60) e grupo defeito ósseo tratado com laser 120J/cm² (GL120). Os animais foram submetidos à irradiação laser em um único ponto sobre o defeito ósseo por sete sessões, em dias alternados. Nos grupos tratados com laser, em ambas as fluências, foi evidenciada uma maior quantidade de osso neoformado comparado ao controle. A análise de birrefringência demonstrou que os defeitos ósseos irradiados apresentaram maior deposição e melhor organização estrutural das fibras colágenas, principalmente no grupo tratado com laser na fluência de 120J/cm². A imunorreatividade à COX-2, CBFA-1 e VEGF foi detectada de forma similar nas duas fluências utilizadas e na análise biomecânica não houve diferença estatística significativa entre os grupos. Portanto, a LLLT, nas duas fluências utilizadas, estimulou o reparo ósseo em tíbias de ratas osteopênicas. No segundo estudo, foram analisados os efeitos do Biosilicato® associado à LLLT no reparo ósseo de ratas osteopênicas, a partir de quatro grupos experimentais: grupo controle com defeito ósseo sem tratamento (GC); grupo defeito ósseo preenchido com Biosilicato® (GB); grupo defeito ósseo preenchido com Biosilicato® e irradiado com LLLT, com fluência de 60J/cm² (GBL60); e grupo defeito ósseo preenchido com Biosilicato® e irradiado com LLLT, com fluência de 120J/cm² (GBL120). O Biosilicato® foi utilizado na forma de partículas com granulometria de 180-212μm e os animais tratados com laser foram irradiados em um único ponto sobre o defeito ósseo por sete sessões, em dias alternados. Os resultados demonstraram que a LLLT, nas fluências de 60J/cm² e 120J/cm², estimulou a expressão de COX-2 nas células circunjacentes ao biomaterial, promoveu aumento na deposição de fibras colágenas e na resposta biomecânica. A análise morfométrica revelou que os animais com defeitos ósseos preenchidos com Biosilicato® e submetidos à irradiação laser com fluência de 120J/cm² apresentaram maior área de osso neoformado quando comparados aos animais dos demais grupos. Desse modo, a LLLT, principalmente na fluência de 120J/cm², associada à aplicação do Biosilicato®, favoreceu o processo de reparo ósseo em defeitos induzidos em tíbias de ratas osteopênicas. Tais resultados são fundamentais na elucidação dos mecanismos biológicos envolvidos no reparo de fraturas de difícil consolidação, em especial àquelas associadas a processos patológicos osteometabólicos, como a osteoporose.

Page generated in 0.0356 seconds