• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 292
  • 208
  • 52
  • 31
  • 31
  • 31
  • 31
  • 31
  • 31
  • 12
  • 11
  • 7
  • 7
  • 4
  • 3
  • Tagged with
  • 718
  • 170
  • 91
  • 80
  • 75
  • 67
  • 62
  • 56
  • 55
  • 53
  • 50
  • 49
  • 48
  • 45
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
401

Avaliação do desempenho de bomba multifásica na geração de microbolhas de ar para o processo de flotação por ar dissolvido aplicado ao pré-tratamento de efluente de indústria têxtil / Evaluation of performance of multiphase pump in the air microbubble generation for dissolved air flotation process applied to pre-treatment of textile wastewater

Pioltine, André 25 March 2009 (has links)
A flotação por ar dissolvido (FAD) é um método de separação de fases bastante utilizado em sistemas de tratamento de efluentes industriais. Nos últimos 20 anos, numerosos avanços têm contribuído para uma maior eficiência deste processo. Entre estes, podem-se citar os avanços nos métodos para a saturação de ar na água. Atualmente tem-se realizado estudos com a utilização de bombas multifásicas em substituição às unidades de saturação tradicionais, com vistas a se buscar maior simplicidade e facilidade operacional, aliados à menor necessidade de manutenção periódica da unidade de saturação. Desta forma, o presente trabalho teve como objetivo avaliar o desempenho de uma bomba multifásica na geração de microbolhas de ar no processo de flotação por ar dissolvido para o tratamento de efluente de indústria têxtil. O projeto foi dividido nas seguintes etapas: Etapa I - com o emprego do Flotateste, foram determinadas as dosagens adequadas de coagulante e polímero para o tratamento do despejo líquido industrial em estudo; Etapa II - utilizando-se uma unidade piloto de flotação por ar dissolvido montada nas instalações de uma indústria têxtil, avaliou-se a influência das condições de operação (taxa de aplicação superficial, razão de recirculação, pressão de saturação e quantidade de ar fornecida) na eficiência do sistema constituído pela bomba multifásica. Considerando a taxa de aplicação superficial empregada neste estudo, a qual foi mantida em faixa estreita de valor (TASclar em torno de 128,6 ± 10 m/d), verificou-se que os maiores valores de eficiência de remoção dos parâmetros monitorados foram obtidos nos ensaios realizados com razão de recirculação igual a 30% associados ao fornecimento de ar de 13%. Nos ensaios onde se realizou a avaliação da concentração de ar presente na recirculação pressurizada, as concentrações de ar efetivamente fornecidas (fração dissolvida e não dissolvida) pelo sistema constituído pela bomba multifásica, foram superiores às concentrações máximas teóricas de ar dissolvido calculadas a partir da Lei de Henry. O valor da relação A/S que forneceu os melhores resultados situou-se em torno de 0,015 g ar/g sólidos. Desta forma, sugere-se tal valor como subsídio ao projeto de sistema de flotação constituído pela tecnologia em estudo nesta pesquisa. / The dissolved air flotation is a method for solid/liquid separation that is used in the industries to treat the wastewater. In the last 20 years, several advances have been added to increase the process\' efficiency. For example, there are the advances in the air saturation methods. Nowadays, studies have been carried out with the use of multiphase pumps instead of conventional saturator units. This way, the aim of this research was to evaluate the performance of a multiphase pump in the air microbubble generation for dissolved air flotation process that is applied to treat the effluent of textile industry. The research was performed in two stages: i) on laboratory scale (Flotatest), where the adequate dosages of coagulant and flocculation aid were carried out; ii) in a pilot unit, where studies were conducted aiming at the evaluation of operational conditions in the system\'s efficiency. In the pilot unit (hydraulic surface loading equal to 128,6 ± 10m/d) , it was verified that the best results in terms of removal efficiency of monitored parameters were obtained for the essays performed with recirculation ratio equal to 30%, air supply of 13% and A/S ratio equal to 0.015 g air/g solids. The air concentrations supplied (dissolved fraction and non-dissolved fraction) by the system were higher than the maximum theoretical concentration of dissolved air (Henry\'s law).
402

Flotação aplicada ao pós-tratamento do efluente de reator anaeróbio de leito expandido tratando esgoto sanitário / Flotation applied to the post-treatment of effluents from expanded bed anaerobic reactor treating domestic sewage

Rogério Gomes Penetra 23 May 2003 (has links)
Este trabalho apresenta e discute os resultados de um estudo amplo e aprofundado sobre os principais parâmetros operacionais da flotação por ar dissolvido, utilizada no pós-tratamento de efluentes de um reator anaeróbio de leito expandido (RALEx), tratando 10 m3/hora de esgoto sanitário. Foram realizados preliminarmente ensaios utilizando o flotateste, unidade de flotação em escala de laboratório, para identificar as melhores dosagens de coagulante (cloreto férrico), o polímero mais adequado, dentre os 26 testados, e sua respectiva dosagem, o pH de coagulação adequado, o tempo (Tf) e o gradiente de velocidade (Gf) de floculação mais apropriados e a quantidade de ar (S*) requerida. Para obtenção das condições operacionais adequadas para a unidade piloto de flotação, os valores de Tf e de Gf foram variados de zero a 24 minutos e de 40 a 100 s-1, respectivamente. As concentrações de cloreto férrico e de polímero sintético variaram de 15 a 92 mg/L e de 0,25 a 7,0 mg/L, respectivamente. S* variou de 2.85 a 28.5 gramas de ar por metro cúbico de efluente e a taxa de aplicação superficial na unidade de flotação abrangeu de 180 a 250 m3/m2/d. O desempenho da flotação durante a partida do reator anaeróbio também foi investigado. O uso de 50 mg/L de cloreto férrico, de Tf igual a 20 min e Gf de 80 s-1, de S* de 19,7 g de ar por m3 de efluente e taxa de 180 m3/m2/d produziu excelentes resultados nos ensaios com a instalação piloto de flotação, com elevadas remoções de carga de DQO (80,6%), de fósforo total (90,1%) e de sólidos suspensos totais (92,1%) e com turbidez entre 1,6 e 15,4 uT e residuais de ferro de 0,5 mg/L, com remoção estimada, na forma de lodo, de 77 gramas de SST por m3 de efluente tratado. Nestas mesmas condições, no sistema RALEx+FAD, foram observadas remoções globais de 91,6% de carga de DQO, de 90,1% de carga de fósforo e de 96,6% de carga de SST. O emprego da flotação por ar dissolvido (FAD) mostrou-se alternativa bastante atraente para o pós-tratamento de efluentes de reatores anaeróbios. Se a coagulação estiver bem ajustada, o sistema composto de reator anaeróbio seguido de unidade de flotação consegue alcançar excelente remoção de matéria orgânica, redução significativa da concentração de fósforo e de sólidos suspensos, além de precipitação dos sulfetos dissolvidos, gerados no reator anaeróbio. Bons resultados foram alcançados mesmo quando o reator RALEx produziu efluentes de baixa qualidade durante seu período de partida. Nesse período, o sistema de flotação atuou como barreira eficaz, evitando a emissão de efluente de baixa qualidade do sistema. / This research work presents ad discusses the results of a wide and deep study on the main operational parameters of DAF while used for the post-treatment of effluents from a pilot expanded-bed anaerobic (RALEx) reactor. The system received 10 m3 per hour of domestic sewage. Bench-scale assays in flota-test units were first carried out to achieve the best dosage of coagulants (ferric chloride), the best polymer and respective dosages, the adjusted pH for coagulation, the flocculation time (Tf), the proper velocity gradient (Gf) and the amont of air (S*) required. In order to obtain the proper operational conditions in the pilot DAF plant, Tf and Gf were made to vary from zero to 24 minutes and from 40 to 100 s-1, respectively. The chemicals ferric chloride and synthetic polymer concentrations ranged from 15 to 92 mg/L and 0.25 to 7.0 mg/L, repectively. S* varied from 2.85 to 28.5 grams of air per cubic meter of wastewater and the applied flotation rates ranged from 180 to 250 m3.m-2.d-1. DAF performance was also investigated during RALEx start-up period. At the DAF operational conditions of 50 mgFeCl3.l-1, Tf of 15 min, Gf of 80 s-1, S* of 19.7 g of air per m3 of wastewater and the applied loading rate of 180 m3.m-2.d-1, the removal efficiencies attained 80.6% for COD, 90.1% for phosphorus, 92.1% for suspended solids, producing effluents with turbidity ranged from 1.6 to 15.4 NTU, residual Fe of 0.5 mg/L, removing 77 grams of SST per cubic meter of wastewater. At the same conditions, the system RALEx-DAF presented global efficiencies of 91.6% for COD, 90.1% for phosphorus and 96.6% for suspended solids. The utilization of dissolved-air flotation (DAF) constitutes an attractive alternative for the post-treatment of anaerobic reactor´s effluents. If coagulation is well adjusted, such system composed of anaerobic reactor followed by DAF can achieve excellent organic matter removal, expressive solids and phosphorus reduction and precipitation of dissolved sulfide generated in the anaerobic unit. Good results were also obtained even when RALEx produced low quality effluents during start-up period. In such period, the DAF unit functioned as an efficient barrier for avoiding the emission of low quality system effluent.
403

Pós-tratamento físico-químico por flotação de efluentes de reatores anaeróbios de manta de lodo (UASB) / Physical-chemical post-treatment by flotation of effluents from upflow anaerobic sludge blanket (UASB)

Rogério Gomes Penetra 29 May 1998 (has links)
O emprego da flotação por ar dissolvido (FAD) para o pós-tratamento de efluentes de reatores anaeróbios aparenta ser atraente considerando algumas características desse processo físico-químico. A FAD é reconhecidamente um processo de alta taxa, particularmente eficiente na remoção de material particulado em suspensão e de flocos produzidos pela coagulação química de águas residuárias. Além disso, há produção de lodo espesso e provavelmente arraste de parcela de gases e de compostos voláteis, presentes nos efluentes anaeróbios. Entretanto, a concepção de sistemas de FAD deve ser precedida por ensaios em unidades de flotação em escala de laboratório, permitindo a determinação dos principais parâmetros do processo. Neste trabalho, são apresentados e discutidos os resultados obtidos em laboratório e em instalação piloto de flotação com escoamento contínuo recebendo efluente de reator anaeróbio de manta de lodo (UASB), com 18 m3 de volume, tratando esgoto sanitário. Os ensaios em unidade em escala de laboratório foram realizados utilizando diferentes dosagens de cloreto férrico (entre 30 e 110 mg/L) ou de polímero catiônico (entre 1,0 e 16,0 mg/L), atuando como coagulantes. Além disso, foram estudadas as condições de floculação (tempo de 15 e de 25 min, e gradiente médio de velocidade de floculação entre 30 e 100 s-1) e diferentes valores de quantidade de ar fornecido ao processo (S*, entre 4,7 e 28,5 g de ar por m3 de efluente). Com a instalação piloto de FAD foram realizados apenas ensaios preliminares variando-se a taxa de aplicação superficial (140 e 210 m3/m2/d) para diferentes valores de S* (14,8 a 29,5 g de ar por m3 de efluente). Com o emprego de dosagem de 65 mg/L de cloreto férrico, de tempo de 15 min e gradiente médio de velocidade de floculação de 80 s-1 e de 19 g de ar por m3 de efluente, foram observados excelentes resultados em laboratório, com elevadas remoções de DQO (89%), de fosfato total (96%), de sólidos suspensos totais (96%), de turbidez (98%), de cor aparente (91%), de sulfetos (não detectado) e NTK (47%). Considerando o sistema UASB e FAD, nos testes em laboratório, foram observadas remoções globais de 97,7% de DQO, de 98,0% de fosfato total, de 98,9% de SST, de 99,5% de turbidez, de 97,8% de cor aparente e de 59,0% de NTK. Nos ensaios com a instalação piloto de FAD, o sistema apresentou remoções de 93,6% de DQO, de 87,1% de SST, de 90% de sulfetos e de 30% de NTK. / The utilization of dissolved-air flotation (DAF) for the post-treatment of effluents from anaerobic reactors seems to be attractive considering some characteristics features of such a physical-chemical process. DAF is known to be a high-rate process particularly efficient for the removal of suspended particles and flocs produced by the chemical coagulation of wastewaters. Moreover, it produces a thick sludge and probably promotes the stripping of gases and volatile compounds present in anaerobic effluents. However, the design of DAF systems has to be preceeded by assays in lab-scale units permiting to establish the main process parameters. The results obtained from a lab-scale unit receiving effluent of a 18 m3 upflow anaerobic sludge blanket (UASB) reactor treating domestic sewage are presented and discussed. The assays were performed firstly in a lab-scale unit, using ferric chloride (from 30 to 110 mg/L) or cationic polymer (from 1.0 to 16.0 mg/L) as coagulant under different concentrations. In order to obtain proper conditions for flocculation time (t) was fixed at 15 and 25 min and velocity gradient (G) was ranged form 30 to 100 s-1. The required quantity of air (S*) was ranged from 4.7 to 28.5 g of air per m3 of wastewater. Using a FAD pilot plant, only preliminary assays were performed, using two surface load rate values (140 e 210 m3/m2/d) and different S* values (from 14.8 to 29.5 g of air per m3 of wastewater). Using a lab-scale unit, 65 mg/L FeCl3, 15 min for t, 80 s-1 for G and 19.0 g of air per m3 of wastewater for S*, the removal efficiencies obtained were 89% for COD, 96% for total phosphate, 96% for suspended solids, 98% for turbidity, 91% for apparent color, 47% for TKN and sulphites were not detected in final effluent. For the UASB-DAF systems, still in labscale unit, global efficiencies were 97.7% for COD, 98.0% for total phosphate, 98.9% for suspended solids, 99.5% for turbidity, 97.8% for apparent color and 59.0% for TKN. Using DAF pilot plant, system global efficiencies were 93.6% for COD, 87.1% for suspended solids, 90% for sulphites and 30% for TKN.
404

Flexographic deinking with electric field technology by destabilization and flotation

Shemi, Akpojotor 02 July 2008 (has links)
Every year, millions of tons of paper are diverted from landfills and recycled. Newspaper constitutes a large portion of total paper recycled, providing a cheap source of raw material for the paper industry and helping sustainable forestry. The recycling of newsprint paper involves the separation of ink from the newsprint, which is done either by flotation or washing. Conventional flotation processes for separating ink are not adequate for newsprint printed using flexography printing technique and with water-based ink. The removal of these flexographic water-based inks by washing is a better alternative. However, one drawback of washing is that it has lower yield. In addition, the subsequent wash filtrate is difficult and costly to decontaminate. The overall goal is to develop a combination of processes that can remove ink from a feedstock that contains up to 100% flexographic ink newsprint; in the context of process variables with known effects. In the present work the objectives are to (1) demonstrate that incorporating an electric field into a conventional deinking process improves deinking efficiency, (2) propose a mechanism of how incorporating an electric field helps to improve deinking efficiency, (3) demonstrate that an electric field can decontaminate water containing flexographic inks and identify the mechanism behind electric field clarification of water, and (4) demonstrate that by incorporating electric fields into both the flotation deinking stage and water decontamination, the target deinking efficiency can be achieved.
405

Využití tlakovzdušné flotace pro terciární stupeň čištění odpadních vod / The use of a dissolved air flotation for tertiary stage of wastewater treatment

Čmaradová, Miroslava January 2013 (has links)
The thesis is focused on the area of wastewater treatment. There is a solution possibility of using flotation for the removal of phosphorus precipitates formed during the tertiary treatment of wastewater. The first part is devoted to a general description of wastewater treatment, there is also described as a flotation separation technology and precipitation of phosphorus. The second part is practically oriented. It describes the experimental equipment used for the precipitation of phosphorus and subsequent removal of the precipitate flotation, during the experiment and the results obtained.
406

Análise das principais variáveis na flotação industrial do complexo de mineração de Tapira - MG

Silva, Fernando Brandão Rodrigues da 07 March 2016 (has links)
Diante de um cenário de expansão do agronegócio e do aumento do consumo de fertilizantes em função do crescimento exponencial da população, torna-se necessário um melhor aproveitamento das reservas minerais existentes, através da obtenção de produtos de melhor qualidade e em quantidades adequadas para atender à demanda nacional. No Complexo de Mineração de Tapira, da Vale Fertilizantes, é produzido o concentrado fosfático com teor de 35,0% de P2O5 a partir do minério com teor de P2O5 da ordem de 8,0% de P2O5, que são destinados ao suprimento do Complexo Industrial de Uberaba e do Complexo Minero químico de Araxá para fabricação de fertilizantes. A flotação industrial, etapa responsável pela recuperação do P2O5 e, consequentemente, pela viabilidade do negócio, é dividida nos circuitos friável, granulado e ultrafino, sendo que, o concentrado friável e granulado compõem o concentrado convencional. Hoje somente 14,7% da massa que alimenta a usina se torna produto, sendo o restante considerado perdas no processo, sendo que, as maiores perdas de massa estão localizadas no rejeito das flotações, representando 42,3%. De 2012 a 2014, a recuperação mássica global diária da usina de beneficiamento variou de 12,4 a 15,9% enquanto a recuperação metalúrgica diária de P2O5 de 48,7 a 82,4%. Pelo grau de variabilidade, é visível que a usina operou em diferentes condições. Visto isto, este trabalho teve como objetivos analisar a influência das variáveis operacionais e de processo nas recuperações mássica e metalúrgica de P2O5 da flotação industrial dos circuitos granulado, friável e ultrafino. E adicionalmente foi feito uma análise do efeito das variáveis do minério, tais como teores, dureza e percentual de minério da frente 02, nas recuperações globais da usina de beneficiamento e do efeito das dosagens de reagentes nas recuperações obtidas na flotação de bancada, utilizando a metodologia de planejamento de experimentos. Todo trabalho foi realizado utilizando o banco de dados histórico da Vale Fertilizantes de Tapira-MG, onde todas as variáveis independentes foram adimensionalizadas conforme a faixa experimental utilizada. Para fazer as análises estatísticas foi utilizada a técnica de superfície de respostas e os valores das variáveis independentes que maximizam as recuperações foram encontrados através da análise canônica. No estudo da flotação industrial do circuito friável foram obtidos 41,3% de recuperação mássica e 91,3% de recuperação metalúrgica de P2O5, valores bons para o circuito, sendo que as maiores recuperações ocorrem para concentração de sólidos da alimentação nova da flotação entre 45 e 50%, cujos valores estão atribuídos ao tempo de residência da polpa nas células e colunas de flotação industriais. Quanto maior o número de pilhas de minério retomadas no dia, maior a recuperação mássica, porém, neste cenário, a flotação se torna instável, pois há enorme variação de massa na alimentação. Maiores recuperações mássicas são obtidas para dosagem de depressor superior a 120 g/t e para dosagem de coletor sintético de 11,6%. No estudo da flotação industrial do circuito granulado foram obtidos 28,3% de recuperação mássica e 79,4% de recuperação metalúrgica de P2O5, sendo considerados valores bons para o circuito. Maiores recuperações são obtidas quando o percentual de minério da frente 02 se encontra acima de 90%, pelo fato do minério desta frente possuir apatitas mais recuperáveis na flotação. Da mesma forma as recuperações aumentam quando o nível de polpa da etapa rougher está mais alto em função da elevada massa de cargas circulantes que a etapa recebe. Já na análise da flotação industrial do circuito ultrafino, foram obtidos 23,95% de recuperação mássica, sendo que a mesma é maximizada para dosagem de depressor e coletor superior a 420 e 300 g/t, respectivamente. Na análise da influência das variáveis do minério, foi observado que maiores recuperações são obtidas para minérios com teor de P2O5 acima de 8,0%, teor de Fe2O3 na ordem de 28% e percentual de minério da frente 02 de 83%. O percentual de minério duro apresentou forte influência nas recuperações, devido à divisão de massas no circuito que está atrelada a esta variável. No entanto, o percentual de minério duro que maximiza as recuperações ficou bastante próximo da capacidade de projeto da usina de beneficiamento, que é de 20%. Finalmente, no estudo da flotação de bancada, foi notado que nos circuitos friável e granulado as maiores recuperações são atingidas para uma dosagem de coletor superior a 250 g/t e que o aumento simultâneo da dosagem de coletor e do percentual de coletor sintético contribui para o aumento de recuperação na flotação. Porém, neste cenário, está propício a produzir um concentrado mais pobre em termos de teor de P2O5, mostrando que nem sempre a maior recuperação representa o cenário ideal. Desta forma, os resultados apresentados mostraram os valores das variáveis que propiciam maiores recuperações na flotação e, consequentemente, menores perdas no rejeito. / Faced with an agribusiness expansion scenario and the increase in fertilizer consumption due to the exponential growth of the population, it is necessary to make better use of existing reserves, by obtaining products of better quality and in adequate quantities to meet demand national. In Tapira Mining Complex, Vale Fertilizantes, the phosphate concentrate is produced with content of 35.0% P2O5 from ore with content of about 8.0% P2O5, which are intended to supply Complex Industrial Uberaba and Araxá Minero Chemical Complex for the production of fertilizers. The industrial flotation step responsible for the recovery of P2O5 and hence the viability of the business is divided into the crumbly, grainy and ultrathin circuits, and, friable and granular concentrate comprise the conventional concentrated. Today only 14.7% of the mass which feeds the mill product becomes, the remainder being considered losses in the process, and the larger mass losses are located in the waste of flotation, representing 42.3%. From 2012 to 2014, the daily global mass recovery processing plants varied from 12.4 to 15.9% while the daily metallurgical recovery of P2O5 from 48.7 to 82.4%. By the degree of variability, it appears that the plant operated under different conditions. Seen this, this study aimed to analyze the influence of operational and process variables in P2O5 mass and metallurgical recoveries of industrial flotation circuits of grainy, crumbly and ultrathin. And besides was made an analysis of the effect of ore variables, as degrees, hardnesse and the ore front 02 percentage, in global recoveries of processing plant and the effect of dosages of reagents in the recoveries obtained from the bench flotation using the experimental design methodology. All work was performed using the historical database of Vale Fertilizantes of Tapira-MG, where all independent variables were dimensionless as the experimental range used. To make the statistical analysis it used the response surface technique and the values of the independent variables that maximize recoveries were found by canonical analysis. In the study of industrial flotation circuit crispy were obtained from 41.3% mass recovery and 91.3% metallurgical recovery P2O5, good values for the circuit, and the highest recoveries occur for solids concentration of the new flotation power between 45 and 50%, which values are assigned to the residence time of the pulp in cells and industrial flotation columns. The greater the number of ore heaps resumed on the higher the mass recovery, but in this scenario flotation becomes unstable because there is enormous weight variation in the feed. Higher recoveries are obtained for mass depressant dosage exceeding 120 g / t for synthetic collector dosage of 11.6%. In the study of industrial flotation circuit of the granulate were obtained 28.3% to 79.4% mass recovery and metallurgical recovery of P2O5 being considered good values for the circuit. Higher recoveries are obtained when the front ore 02 percentage is above 90%, because the ore of this front have more clear apatite. Likewise recoveries increase when the level of pulp rougher step is highest due to the high mass of circulating step receives loads. In the analysis of industrial flotation circuit of the ultrafine were obtained 23.95% of mass recovery, and the same is maximized to depressant dosage and the top collector 420 and 300 g / t, respectively. The analysis of the influence of variables ore, it was observed that higher recoveries are obtained for ores with P2O5 content above 8.0%, Fe2O3 content in the order of 28% forward and 02 of ore percentage of 83%. Hard ore percentage has strong influence on recoveries due to mass division in the circuit that is linked to this variable. However, the hard ore percentage that maximizes recoveries was very close to the design capacity of the processing plant, which is 20%. Finally, the study of the bench flotation, has noted that in friable and granular circuits the highest recoveries are achieved for a collector dosage exceeding 250 g / t and the simultaneous increase of collector dosage and synthetic collector percentage contributes to the increase recovery in the flotation, but this scenario is suitable to produce a concentrate poorer in terms of P2O5 content, showing that higher recovery is not always the ideal scenario. Thus, the results show the values of variables that provide higher recoveries in the flotation and hence lower losses in the waste. / Dissertação (Mestrado)
407

Avaliação do desempenho de bomba multifásica na geração de microbolhas de ar para o processo de flotação por ar dissolvido aplicado ao pré-tratamento de efluente de indústria têxtil / Evaluation of performance of multiphase pump in the air microbubble generation for dissolved air flotation process applied to pre-treatment of textile wastewater

André Pioltine 25 March 2009 (has links)
A flotação por ar dissolvido (FAD) é um método de separação de fases bastante utilizado em sistemas de tratamento de efluentes industriais. Nos últimos 20 anos, numerosos avanços têm contribuído para uma maior eficiência deste processo. Entre estes, podem-se citar os avanços nos métodos para a saturação de ar na água. Atualmente tem-se realizado estudos com a utilização de bombas multifásicas em substituição às unidades de saturação tradicionais, com vistas a se buscar maior simplicidade e facilidade operacional, aliados à menor necessidade de manutenção periódica da unidade de saturação. Desta forma, o presente trabalho teve como objetivo avaliar o desempenho de uma bomba multifásica na geração de microbolhas de ar no processo de flotação por ar dissolvido para o tratamento de efluente de indústria têxtil. O projeto foi dividido nas seguintes etapas: Etapa I - com o emprego do Flotateste, foram determinadas as dosagens adequadas de coagulante e polímero para o tratamento do despejo líquido industrial em estudo; Etapa II - utilizando-se uma unidade piloto de flotação por ar dissolvido montada nas instalações de uma indústria têxtil, avaliou-se a influência das condições de operação (taxa de aplicação superficial, razão de recirculação, pressão de saturação e quantidade de ar fornecida) na eficiência do sistema constituído pela bomba multifásica. Considerando a taxa de aplicação superficial empregada neste estudo, a qual foi mantida em faixa estreita de valor (TASclar em torno de 128,6 ± 10 m/d), verificou-se que os maiores valores de eficiência de remoção dos parâmetros monitorados foram obtidos nos ensaios realizados com razão de recirculação igual a 30% associados ao fornecimento de ar de 13%. Nos ensaios onde se realizou a avaliação da concentração de ar presente na recirculação pressurizada, as concentrações de ar efetivamente fornecidas (fração dissolvida e não dissolvida) pelo sistema constituído pela bomba multifásica, foram superiores às concentrações máximas teóricas de ar dissolvido calculadas a partir da Lei de Henry. O valor da relação A/S que forneceu os melhores resultados situou-se em torno de 0,015 g ar/g sólidos. Desta forma, sugere-se tal valor como subsídio ao projeto de sistema de flotação constituído pela tecnologia em estudo nesta pesquisa. / The dissolved air flotation is a method for solid/liquid separation that is used in the industries to treat the wastewater. In the last 20 years, several advances have been added to increase the process\' efficiency. For example, there are the advances in the air saturation methods. Nowadays, studies have been carried out with the use of multiphase pumps instead of conventional saturator units. This way, the aim of this research was to evaluate the performance of a multiphase pump in the air microbubble generation for dissolved air flotation process that is applied to treat the effluent of textile industry. The research was performed in two stages: i) on laboratory scale (Flotatest), where the adequate dosages of coagulant and flocculation aid were carried out; ii) in a pilot unit, where studies were conducted aiming at the evaluation of operational conditions in the system\'s efficiency. In the pilot unit (hydraulic surface loading equal to 128,6 ± 10m/d) , it was verified that the best results in terms of removal efficiency of monitored parameters were obtained for the essays performed with recirculation ratio equal to 30%, air supply of 13% and A/S ratio equal to 0.015 g air/g solids. The air concentrations supplied (dissolved fraction and non-dissolved fraction) by the system were higher than the maximum theoretical concentration of dissolved air (Henry\'s law).
408

Influência do uso de polímeros sintéticos no desempenho da flotação por ar dissolvido aplicada no tratamento de água para abastecimento / Influence of synthetic polymer usage on the performance of dissolved air flotation applied to supply water

Luci Sartori 14 August 1998 (has links)
O uso de polímeros sintéticos como auxiliares de floculação no tratamento de águas para abastecimento é uma prática que vem sendo bastante estimulada. Contudo o uso na floculação visando a flotação de águas para abastecimento tem sido pouco estudado. Neste trabalho, são apresentados os resultados de estudo da influência da aplicação de polímeros sintéticos como auxiliares de floculação na clarificação, por flotação, de água preparada com cor elevada (100 ± 9,0 uC) e baixa turbidez (6,80 ± 1,0 uT). Foram investigados três diferentes tipos de polímeros (catiônico, aniônico e não iônico), aplicados conjuntamente ao coagulante primário (sulfato de alumínio). Após a otimização da dosagem deste coagulante (40 mg/L), sem emprego de polímeros, foi estudado o desempenho da flotação diante a redução da dosagem de coagulante conjugado à aplicação de diferentes dosagens de polímeros. Também foram investigadas a influência do tempo decorrido após a mistura rápida para a adição do polímero, e do tempo e gradiente médio de velocidade na floculação para a flotação. Foram utilizadas duas unidades de flotação por ar dissolvido, uma em escala de laboratório (Flotateste) e outra em escala piloto (com escoamento contínuo). Após a adequação dos parâmetros de floculação, os ensaios obtidos com o flotateste mostraram que a aplicação de 0,25 mg/L de polímero não iônico permitiu a redução de 50% na dosagem de coagulante, sem queda significativa na eficiência de remoção de cor e turbidez (96% e 93% respectivamente). Por sua vez, o polímero catiônico, na dosagem de 0,25 mg/L, possibilitou redução de 70% na dosagem de sulfato de alumínio, com eficiência de remoção de cor e turbidez de 90%. A instalação piloto de flotação operando com TASap de 262 m3/m2d, e aplicação de polímeros, nas condições otimizadas com o flotateste, foi capaz de fornecer bons resultados de remoção de cor aparente (82% e cor no efluente de 18,6 uC) e de turbidez (80% com turbidez de 1,40 uT no efluente). Nos ensaios com a unidade piloto de flotação operando com TASap de 525 m3/m2d, com redução de 70% na dosagem de coagulante (aplicação de 0,25 mg/L de polímero catiônico), observou-se redução de até 79% na massa de Iodo gerada. / The usage of synthetic polymers as flocculation aids for the treatment of supply water is a practice which have been widely stimulated, however its usage in flocculation aiming supply water flocculation has been scarcely studied. This work presents the results of the study of the influence of synthetic polymer application as a flocculation aids for clarifying prepared water containing high levei of color (100 ± 9.0 CU) and low turbidity (6.80 ± 1.0 NTU) through flotation. Three different kinds of polymers were investigated - cationic, anionic and non-ionic - which were applied together with the primary cogulant (aluminium sulphate). After the optimization of this coagulant dosage (40 mg/L), without the utilization of polymers, it was studied the flotation performance by the reduction of the coagulant dosage together with the application of different polymer dosages. It was also studied the influence of the time after rapid mixing for the polymer addition, and of time and average velocity gradient and flotation. Two units of dissolved air flotation were used, a bench unit and a pilot plant unit (with continuous flow). After the flocculation parameters adequacy, the essays obtained with FLOTATESTE showed that the application of 0.5 mg/L of non-ionic polymer allowed a reduction of 50% on coagulant dosage, without meningful drops of the color and turbidity removal efficient (96% and 93% respectively). On the other hand, the cationic polymer, at 0.25 mg/L, enabled a 70% reduction on the aluminium sulphate dosage with color and turbidity removal efficiency of 90%. The plant flotation unit, operating under a flow rate of 262 m3/m2d and with polymer application, under conditions optimized by FLOTATESTE, was able to provide good results of colour removal (82% and effluent color of 18.6 CU) and turbicity removal (83% with turbicity of 1.23 NTU in the effluent). In the essays with the pilot plant flotation unit, operating under a flow rate of 525 m3/m2d after reduction of 70% on the coagulant dosage (application of 0,25 mg/L of cationic polymer) , an up to 79% reduction in mass of sludge generated was observed.
409

Influência da velocidade de entrada na zona de contato na eficiência de clarificação de unidades retangulares de flotação por ar dissolvido aplicado no tratamento de águas para abastecimento / Influence of the velocity in the contact zone entrance on the clarification efficiency of rectangular dissolved air flotation units applied to water treatment to supply

Kisner Anderson Maia 07 October 2010 (has links)
A flotação por ar dissolvido (FAD) é reconhecida atualmente como técnica eficiente para a etapa de clarificação em sistemas de tratamento de água para abastecimento. Diversos estudos vêm sendo realizados para aprimoramento dessa técnica e das características físicas das unidades FAD. Seguindo essa tendência, o presente trabalho teve como objetivo estudar os efeitos da velocidade na entrada da zona de contato (\'V IND.EZC\') na eficiência de clarificação de unidades retangulares FAD. Para o presente estudo foi utilizada água sintética preparada através da adição de 1,0 mg/L de ácido húmico e 8,5 mg/L de caulinita, a qual foi coagulada com sulfato de alumínio. A pesquisa foi dividida em duas fases: FASE I - com o emprego do Flotateste foram determinadas as dosagens adequadas de coagulante, o pH adequado de coagulação com a medição do potencial zeta das partículas (PZ), o gradiente médio de velocidade para floculação e o tempo médio para floculação para o tratamento da água sintética em estudo; FASE II - utilizando unidade FAD em escala piloto foram realizados ensaios para diferentes variações na altura da entrada da zona de contato (he) da câmara de flotação de forma a se obter diferentes valores de \'V IND.EZC\'. Nesta fase foram investigadas duas diferentes condições de coagulação as quais forneceram bons resultados por flotação: 1ª condição, aplicação de 42,5 mg/L de \'AL IND.2\'(\'SO IND.4\')IND.3\' e pH de 6,35 \'+ OU -\' 0,05 na qual resultou em PZ positivo em torno de +10 mV e para 2ª condição, aplicação de 22,5 mg/L de \'AL IND.2\'(\'SO IND.4\')IND.3\' e pH de 6,40 \'+ OU -\' 0,05 na qual resultou em PZ próximo de 0 mV. Os ensaios foram monitorados e comparados entre si os valores residuais de turbidez e cor aparente. Em todos os ensaios as taxas de aplicação superficial foram mantidas em faixas estreitas de verificando-se que os melhores resultados residuais dos parâmetros monitorados foram obtidos para a 1ª condição de estudo com valores de 0,66 NTU de turbidez e cor aparente igual a 2 uC (eficiências de 90,5 e 93,9% respectivamente). Os resultados demonstraram que para a faixa de valores de \'V IND.EZC\' entre 62,2 e 12.432,4 m/h pouca influência desse parâmetro foi observada na eficiência do processo de clarificação por flotação para ambas as condições de coagulação investigadas. Entretanto, a faixa de valores de \'V IND.EZC\' entre 124,3 e 180,2 m/h forneceram as melhores condições de flotação. Portanto, sugere-se tal faixa de valores como subsídio ao projeto de sistemas de flotação constituído pelas características apresentadas nesta pesquisa. / Dissolved air flotation (DAF) is currently recognized as an efficient technique for water clarification in water treatment systems. Several studies have been conducted to improve this technique and the physical characteristics of DAF units in order to constantly improve their performance. Following this trend, the aim of this research was to evaluate the effects of the velocity in the contact zone entrance on the clarification efficiency of rectangular DAF units. A DAF pilot plant fed with synthetic water prepared by adding 1.0 mg/L of humic acid and 8.5 mg/L of kaolin, and coagulated with aluminum sulfate was used. The research was divided into two phases: I) by using a laboratory scale DAF unit (Flotatest) the optimal coagulation, flocculation, and flotation conditions for the synthetic water previously described were investigated; and II) by using a DAF pilot unit tests were performed for different variations in the height of the contact zone entrance (he) of the flotation chamber to obtain different values of velocity in the contact zone entrance. In this phase two different conditions of coagulation were investigated yielding good results: 1st condition: application of 42.5 mg/L of \'AL IND.2\'(\'SO IND.4\')IND.3\' and pH 6.35 \'+ OR -\' 0.05, which resulted in zeta potential of positive particles around +10 mV, and 2nd condition: application of 22.5 mg/L \'AL IND.2\'(\'SO IND.4\')IND.3\' and pH 6.40 \'+ OR -\' 0.05, which resulted in zeta potential of particles near zero. The tests were monitored and the residual values of turbidity and apparent color were compared. In all experiments, the hydraulic surface loadings were kept in narrow bands of values (in the contact zone equal to 180 \'+ OR -\' 4 m/h and in the clarification zone, equal to 184 \'+ OR -\' 4 m/d). It was verified that the best residual results of the parameters monitored were obtained for the 1st condition with 0.66 NTU turbidity and apparent color equal to 2 uC (efficiencies of 90.5 and 93.9%, respectively). The results showed that for the range of values of velocity in the contact zone entrance between 62.2 and 12432.4 m/h little influence of this parameter was observed on the clarification efficiency process by flotation for both coagulation conditions investigated. However, as the range of values between 124.3 and 180.2 m/h provided the best flotation conditions, such a range should be adopted for the designs of rectangular DAF units.
410

Emprego de polímeros em unidade piloto de floto-filtração como pós-tratamento de efluentes de reatores anaeróbios de leito expansível tratando esgoto sanitário / Post-treatment of effluents from anaerobic reactor treating domestic sewage by flotation/filtration pilot system with cationic synthetic polymers

Eduardo Rocha Dias Santos 19 September 2008 (has links)
Este trabalho avaliou o desempenho de uma unidade piloto de floto-filtração, que utilizou polímeros associados ao cloreto férrico no pós-tratamento de efluente de reator anaeróbio de leito expansível (RALEx), tratando esgoto sanitário. Preliminarmente, testaram-se em ensaios de flotação por ar dissolvido em escala de bancada (flotateste), baixas dosagens de polímero sintético catiônico de alto peso molecular como auxiliar de flotação. As dosagens de coagulante deram-se na relação de mg Fe/L por unidade de turbidez (NTU) do RALEx (Fe/turbidez) e variou de 0,08 a 0,18 nos ensaios de bancada. As dosagens fixas de polímero, associadas ao cloreto férrico ocorreram entre 0,1 e 0,4 mg/L. As variáveis operacionais dos ensaios de flotateste e de floto-filtração em escala piloto utilizadas foram: gradiente de floculação de 90/s, tempo de floculação de 18 min, recirculação de 15%, pressão de saturação na câmara com 450±10 kPa e taxa de aplicação superficial igual a 300 \'M POT.3\'/\'M POT.2\'.d. Para os ensaios piloto de floto-filtração foi utilizado leito filtrante de areia, com tamanho efetivo de 0,8 mm e profundidade igual a 1,10 m. Dentre os ensaios piloto de floto-filtração realizados, foram obtidos os melhores resultados ao utilizar dosagens variáveis de cloreto férrico respeitando a relação de 0,15 mg Fe/L para cada unidade de turbidez (Fe/turbidez), associado a dosagens fixas de 0,4 mg/L de polímero, produzindo efluente final com SST < 2 mg/L. Para as condições da presente pesquisa, o polímero que propiciou em flotateste efluente com turbidez mais baixa, tem como características: catiônico, alto peso molecular e altíssima densidade de carga. Foi verificado nos ensaios piloto com dosagens de polímero entre 0,4 e 1,2 mg/L um teor de sólidos totais > 3% no lodo flotado. / This work assessed the performance of domestic sewage treatment pilot unit consisting of anaerobic reactor followed dissolved-air flotation/filtration (DAFF). Associated ferric chloride was used polyelectrolytes. First, was tested in lab-scale dissolved-air flotation (LSDAF), low dosages of cationic synthetic polymer with high molecular weight as aiding of flotation. Coagulant dosages was given in mg Fe/L by unit of turbidity (NTU) of RALEx and it varied from 0,08 to 0,16 in LSDAF. The fixed dosages of polymer associated to the ferric chloride happened between 0,1 and 0,4 mg/L.The variables operational of the LSDAF and DAFF were: velocity gradient (90/s), flocculation time (18 min), recirculation rate (15%), air requirements (12 g air/\'M POT.3\'), saturation pressure (450±10 kPa) and surface load (300 \'M POT.3\'/\'M POT.2\'.d). In pilot unit DAFF, of bed filter of sand was used, with effective size of 0,8 mm and depth the same to 1,10 m. Best results were achieved with 0,15 mg Fe/L per turbidity associated to 0,4 mg/L of polyelectrolytes, producing final effluent with TSS < 2 mg/L. For the conditions of this research, provide that the polyelectrolyte in LSDAF, effluent with lower turbidity, is characterized: cationic, high molecular weight and high load density. It was verified in the pilot essays with dosages of polymer between 0,4 and 1,2 mg/L thickening sludge > 3%.

Page generated in 0.0661 seconds