1

CONTROLLING QUASI-2D SEPARATION WITH FLOW INJECTION

Hunter Douglas Nowak (12467895) 27 April 2022 (has links)
<p>Highly loaded aerodynamic devices for propulsion and power generation are emerging to increase power output in a more compact machine are emerging. These devices can experience increased losses due to separation, as in the low-pressure turbine, which arise due to the operation at conditions that increases the adverse pressure gradients ore decrease the Reynolds number of the flow through the device. Therefore, flow control strategies become appealing to reduce losses at these conditions. This work aims to validate flow injection as an effective flow control strategy in the transonic regime.</p> <p>A test facility which was used to study boundary layer separation in a quasi-2d test article was modified to include flow injection and conditions were modified so that the facility was operated in the transonic regime. Valves were chosen which could achieve a wide range of excitation frequencies and the flow control ports were designed to accommodate their nominal flow rate. A preliminary test matrix was built while considering the limitations of the test facility.</p> <p>A numerical study was conducted to identify flow structures of interest and determine a preliminary understanding of the test article. The flow control was then added to the numerical study to guide the experimental set points for injected flow. The response of the flow to continuous slot blowing was characterized, and a 3D simulation with discrete injection ports was done to ensure the set-points determined from the 2D study were viable for discrete injection.</p> <p>Blow-down experiments were then conducted to study the behavior of bulk separation in a transonic regime for a quasi-2D geometry. Once behavior of the separation was understood, steady injection and then pulsated injection were applied in attempts to mitigate the separation. Steady injection was utilized to find the required pressure of injection relative to the total pressure at the inlet of the test article, while the pulsated injection served to identify a frequency at which the time averaged mitigation of separation was greatest.</p> <p>The experiments show that both steady and pulsated flow injection are viable techniques in flow control. It is also shown that pulsation does not allow for a lower pressure injection, but instead allows for the same effect with a lower mass flow requirement. Two-dimensional computational simulations are shown to be effective in determining injection frequencies but not the extent of separation or required injection pressures.</p>
2

Development of High-throughput Membrane Filtration Techniques for Biological and Environmental Applications / Development of High-throughput Membrane Filtration Techniques

Kazemi, Amir Sadegh 11 1900 (has links)
Membrane filtration processes are widely utilized across different industrial sectors for biological and environmental separations. Examples of the former are sterile filtration and protein fractionation via microfiltration (MF) and ultrafiltration (UF) while drinking water treatment, tertiary treatment of wastewater, water reuse and desalination via MF, UF, nanofiltration (NF) and reverse-osmosis (RO) are examples of the latter. A common misconception is that the performance of membrane separation is solely dependent on the membrane pore size, whereas a multitude of parameters including solution conditions, solute concentration, presence of specific ions, hydrodynamic conditions, membrane structure and surface properties can significantly influence the separation performance and the membrane’s fouling propensity. The conventional approach for studying filtration performance is to use a single lab- or pilot-scale module and perform numerous experiments in a sequential manner which is both time-consuming and requires large amounts of material. Alternatively, high-throughput (HT) techniques, defined as the miniaturized version of conventional unit operations which allow for multiple experiments to be run in parallel and require a small amount of sample, can be employed. There is a growing interest in the use of HT techniques to speed up the testing and optimization of membrane-based separations. In this work, different HT screening approaches are developed and utilized for the evaluation and optimization of filtration performance using flat-sheet and hollow-fiber (HF) membranes used in biological and environmental separations. The effects of various process factors were evaluated on the separation of different biomolecules by combining a HT filtration method using flat-sheet UF membranes and design-of-experiments methods. Additionally, a novel HT platform was introduced for multi-modal (constant transmembrane pressure vs. constant flux) testing of flat-sheet membranes used in bio-separations. Furthermore, the first-ever HT modules for parallel testing of HF membranes were developed for rapid fouling tests as well as extended filtration evaluation experiments. The usefulness of the modules was demonstrated by evaluating the filtration performance of different foulants under various operating conditions as well as running surface modification experiments. The techniques described herein can be employed for rapid determination of the optimal combination of conditions that result in the best filtration performance for different membrane separation applications and thus eliminate the need to perform numerous conventional lab-scale tests. Overall, more than 250 filtration tests and 350 hydraulic permeability measurements were performed and analyzed using the HT platforms developed in this thesis. / Thesis / Doctor of Philosophy (PhD) / Membrane filtration is widely used as a key separation process in different industries. For example, microfiltration (MF) and ultrafiltration (UF) are used for sterilization and purification of bio-products. Furthermore, MF, UF and reverse-osmosis (RO) are used for drinking water and wastewater treatment. A common misconception is that membrane filtration is a process solely based on the pore size of the membrane whereas numerous factors can significantly affect the performance. Conventionally, a large number of lab- or full-scale experiments are performed to find the optimum operating conditions for each filtration process. High-throughput (HT) techniques are powerful methods to accelerate the pace of process optimization—they allow for multiple experiments to be run in parallel and require smaller amounts of sample. This thesis focuses on the development of different HT techniques that require a minimal amount of sample for parallel testing and optimization of membrane filtration processes with applications in environmental and biological separations. The introduced techniques can reduce the amount of sample used in each test between 10-50 times and accelerate process development and optimization by running parallel tests.

Page generated in 0.0823 seconds