• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Étude et prédiction des propriétés de rétention en eau des sols : Prise en compte de la composition et de l'état structural du sol

Al Majou, Hassan 24 April 2008 (has links) (PDF)
Les propriétés de rétention en eau et leur relation avec les caractéristiques du sol ont fait l'objet de nombreuses études ces trente dernières années. L'objectif de ce travail est d'analyser la validité des fonctions de pédotransfert (FPT) établies avec des sols du territoire national, et de les comparer à celles développées à l'échelle de l'Europe. Les résultats montrent que les FPT établies avec des sols du territoire national conduisent à des prédictions de qualité meilleure ou similaire à celles obtenues avec les FPT établies à l'échelle de l'Europe. Il a été aussi montré que pour des sols du territoire national, des classes de pédotransfert établies par classe de texture (CFPT texturales) ou par classe de texture et de structure (CFPT texturo-structurales) conduisaient à de prédictions de meilleure qualité que celles obtenues avec des FPT beaucoup plus élaborées et réclamant une connaissance détaillée de la composition des sols. La prédiction des propriétés de rétention en eau est améliorée significativement lorsque la teneur en eau volumique à la capacité au champ in situ est utilisée comme prédicteur par classe de texture. Enfin, Les propriétés de rétention en eau ont été discutées pour les sols argileux en fonction de leur état structural à l'échelle des constituants élémentaires (mode d'assemblage des particules d'argile). Les résultats montrent que les propriétés de rétention en eau peuvent s'expliquer par les différences de teneur en argile et de mode d'assemblage des particules composant la phase argileuse.
2

Évaluation des fonctions de pédotransfert d’un sol hétérogène, milieu récepteur d’eau usée traitée, sur un site pilote dédié / Evaluation of pedotransfer functions of a heterogeneous soil, the receptor milieu for treated wastewater, a dedicated pilot site

Nasri, Behzad 10 December 2013 (has links)
Cette thèse a été effectuée dans le cadre du projet ANCRES. Son rôle est d'assurer la compréhension physique du milieu récepteur, le sol, alors qu'une autre équipe étudie l'impact physico-chimique des eaux usées traitées sur le sol. Pour cela, il faut connaître ses propriétés texturales et structurales contrôlant ses fonctions d'épuration et d'évacuation. La problématique est donc de comprendre le processus de l'infiltration imposée par un dispositif d'ANC dans un sol caillouteux. D'abord, suite au positionnement du site pilote d'ANC au pied d'un versant au cœur du plateau portlandien dans le département de l'Yonne en France, on a identifié là un type de sol hétérogène et complexe, caillouteux, une colluvion qui n'était pas cartographiée sur la carte géologique BRGM de cette région et sur laquelle on focalise la thèse. Ensuite, dans le sol complexe du site pilote, on a d'abord mesuré la conductivité hydraulique du sol par l'appareil Guelph sur 15 m² de la fouille de l'ANC à une profondeur de 120 cm : au total, on a fait 15 essais d'infiltration. De plus, on a récupéré 15 échantillons du sol accompagnant ses essais de Guelph pour la caractérisation physique au laboratoire. On a mesuré la texture, l'humidité résiduelle (HR), la teneur en cailloux (Rw) et la matière organique (MO) des échantillons au laboratoire. Ensuite, pour l'étude du processus d'infiltration, on a instrumenté ce site par un dispositif de surveillance hydrique (tensiométrie, teneur en eau, piézométrie) et de prélèvement d'eau interstitielle du sol. De plus, la masse volumique (densité) apparente d'un sol hétérogène a été déterminée. Parmi les paramètres mesurés, certains sont choisis comme indicateurs pour caractériser un sol comme milieu récepteur potentiel des eaux usées traitées en ANC. Puis, en utilisant la MO et la texture des échantillons, on a estimé la masse volumique apparente de la matrice du sol du site piloteau moyen de fonctions de pédotransfert appelées BD-FPTs et on a testé la relation entre la conductivité hydraulique à saturation Ks et la texture de ce sol complexe. Pour cela, une méthodologie en quatre phases a été développée pour évaluer la capacité prédictive des fonctions Ks-FPTs. Cette méthodologie de sélection n'a pas été trouvée dans la littérature mais est élaborée pour les besoins de la thèse. On a déduit les meilleures Ks-FPTs pour ce type de sol. Enfin, avec les données d'humidité volumique et du potentiel matriciel du sol, acquises par une centrale d'acquisition des données, le régime hydrodynamique du sol sous le massif filtrant de l'ANC a été étudié et on a mis en évidence l'écoulement préférentiel dans un sol caillouteux. Les résultats ont montré que dans la colluvion, bien que la matrice du sol soit fine, la conductivité hydraulique mesurée est plus élevée qu'attendu. Cela démontre que la fraction des cailloux dans le sol joue un rôle essentiel en accélérant l'évacuation des eaux usées traitées et aussi l'eau pluviale vers les couches sous-jacentes, et finalement vers la nappe. Cette propriété serait un point fort pour la fonction de transfert du sol et on peut en déduire une méthode pour améliorer la capacité de transfert de l'eau des sols lourds dans les projets d'aménagement urbain ou périurbain : l'ajout de graviers et graves calcaires par mélange au sol en place. On conclut que cette expérimentation, unique en son genre, a été utile pour évaluer la fonction de rétention / transfert de l'eau dans le sol recevant les eaux usées traitées. On a identifié les paramètres prédicteurs pertinents et les relations empiriques qui permettent de faire l'économie de nombreux essais in situ d'eau / The soil is an essential compartment in hydrologic cycle of water in the nature. Therefore, it is clear that taking into account the properties and organization of the soil is essential to the understanding and management of flows involved in the development of the quality of groundwater and surface water. The on-site sanitation (ANC) is a management method of domestic wastewater, by which the water is sent into the soil after settling and filtration liquefaction / aerobic degradation. The second step was often provided by the top soil in place himself, and this continues to this day on many plots of on-site sanitation.This thesis was carried out under ANCRES project. Its role was to ensure the physical understanding of the receptor medium, soil, while another research team was investigating the physico-chemical impact of treated wastewater on the sol. To ensure it, we have to understand its textural and structural properties controlling its purifying power and hydrodynamic processes. So, the problematic is to understand the process of infiltration imposed by an ANC in a heterogeneous stony soil. At first, due to the positioning of the pilot ANC site, at the foot of a slope in the Yonne department in France, a type of complex and heterogeneous soil, a colluvion, was identified. This soil has not been mapped on the BRGM (Bureau de recherches géologiques et minières) geological map of the area. So, the thesis was focalised on this soil. Then, in this soil complex at a depth of the 120 cm of the excavation of the ANC, the soil hydraulic conductivity was first measured by a Guelph apparatus on 15 m². We totally made 15 infiltration tests. Furthermore, we have collected 15 soil samples with each Guelph test for physics laboratory physical characterization. Then, in order to study the soil functions, this site was instrumented by the water monitoring devices (tensiometers, water content probes, and piezometer) and the interstitial water sampling device from the soil. In addition, the bulk of this heterogeneous soil was determined. Among the measured parameters, a series of indicators chosen to characterize the soil as a potential receptor medium of treated wastewater of the ANC. Then, the bulk density of the soil matrix using pedotransfer functions called BD-FPTs was estimated and the relationship between saturated hydraulic conductivity Ks and the texture of the soil complex (by Ks-FPT function) was tested. For this aim, a four-phase methodology was developed to assess the predictive ability of Ks- FPTs functions. This methodology in four phases is not found in the literature but was prepared for the purposes of the thesis. We concluded the best Ks- FPTS for this type of soil. Finally, with the volumetric water content and soil matrix potential data acquired by a the data loggers, the hydrodynamic regime of the soil under the sand pack of the ANC has been studied and demonstrated the preferential flow in a stony soil was demonstrated. The results showed that in the colluvion, although the soil matrix is fine, the measured hydraulic conductivity is higher than expected. This shows that the stone fraction in the soil plays an important role in accelerating the evacuation of treated wastewater and also rainwater to the underlying layers, and finally to the water table. This property would be a strong point for the transfer function of the soil and we can deduce a method to improve the transfer function of heavy soils in urban or peri-urban development projects. This could be possible by adding the gravel and -limestone to soil matrix and mixing them. It has been concluded that this experiment, unique in its kind, has been useful in evaluating the function of retention / transfer of water in the soil receiving treated wastewater. In addition, the relevant predictor parameters and empirical relationships that make the economy of many water tests were identified
3

Évaluation des fonctions de pédotransfert d'un sol hétérogène, milieu récepteur d'eau usée traitée, sur un site pilote dédié

Nasri, Behzad, Nasri, Behzad 10 December 2013 (has links) (PDF)
Cette thèse a été effectuée dans le cadre du projet ANCRES. Son rôle est d'assurer la compréhension physique du milieu récepteur, le sol, alors qu'une autre équipe étudie l'impact physico-chimique des eaux usées traitées sur le sol. Pour cela, il faut connaître ses propriétés texturales et structurales contrôlant ses fonctions d'épuration et d'évacuation. La problématique est donc de comprendre le processus de l'infiltration imposée par un dispositif d'ANC dans un sol caillouteux. D'abord, suite au positionnement du site pilote d'ANC au pied d'un versant au cœur du plateau portlandien dans le département de l'Yonne en France, on a identifié là un type de sol hétérogène et complexe, caillouteux, une colluvion qui n'était pas cartographiée sur la carte géologique BRGM de cette région et sur laquelle on focalise la thèse. Ensuite, dans le sol complexe du site pilote, on a d'abord mesuré la conductivité hydraulique du sol par l'appareil Guelph sur 15 m² de la fouille de l'ANC à une profondeur de 120 cm : au total, on a fait 15 essais d'infiltration. De plus, on a récupéré 15 échantillons du sol accompagnant ses essais de Guelph pour la caractérisation physique au laboratoire. On a mesuré la texture, l'humidité résiduelle (HR), la teneur en cailloux (Rw) et la matière organique (MO) des échantillons au laboratoire. Ensuite, pour l'étude du processus d'infiltration, on a instrumenté ce site par un dispositif de surveillance hydrique (tensiométrie, teneur en eau, piézométrie) et de prélèvement d'eau interstitielle du sol. De plus, la masse volumique (densité) apparente d'un sol hétérogène a été déterminée. Parmi les paramètres mesurés, certains sont choisis comme indicateurs pour caractériser un sol comme milieu récepteur potentiel des eaux usées traitées en ANC. Puis, en utilisant la MO et la texture des échantillons, on a estimé la masse volumique apparente de la matrice du sol du site piloteau moyen de fonctions de pédotransfert appelées BD-FPTs et on a testé la relation entre la conductivité hydraulique à saturation Ks et la texture de ce sol complexe. Pour cela, une méthodologie en quatre phases a été développée pour évaluer la capacité prédictive des fonctions Ks-FPTs. Cette méthodologie de sélection n'a pas été trouvée dans la littérature mais est élaborée pour les besoins de la thèse. On a déduit les meilleures Ks-FPTs pour ce type de sol. Enfin, avec les données d'humidité volumique et du potentiel matriciel du sol, acquises par une centrale d'acquisition des données, le régime hydrodynamique du sol sous le massif filtrant de l'ANC a été étudié et on a mis en évidence l'écoulement préférentiel dans un sol caillouteux. Les résultats ont montré que dans la colluvion, bien que la matrice du sol soit fine, la conductivité hydraulique mesurée est plus élevée qu'attendu. Cela démontre que la fraction des cailloux dans le sol joue un rôle essentiel en accélérant l'évacuation des eaux usées traitées et aussi l'eau pluviale vers les couches sous-jacentes, et finalement vers la nappe. Cette propriété serait un point fort pour la fonction de transfert du sol et on peut en déduire une méthode pour améliorer la capacité de transfert de l'eau des sols lourds dans les projets d'aménagement urbain ou périurbain : l'ajout de graviers et graves calcaires par mélange au sol en place. On conclut que cette expérimentation, unique en son genre, a été utile pour évaluer la fonction de rétention / transfert de l'eau dans le sol recevant les eaux usées traitées. On a identifié les paramètres prédicteurs pertinents et les relations empiriques qui permettent de faire l'économie de nombreux essais in situ d'eau

Page generated in 0.0843 seconds