Blízká fotometrie / Near-field photometry

Kutý, Tomáš January 2015 (has links)
This thesis is focused on the theoretical and practical introduction to the verification procedures used today for obtaining luminosity curves of lamps. The introduction acquaints readers with the photometric variables. Consequently, it is theoretically described procedure for constructing luminance curves by zonal flow and further familiarization with the near-field photometry. For the practical part was chosen several lights. These lamps were measured by luxmeter first from a very close photometric distance from lights, and then from large distance. The next step was to obtain pictures of luminaries in planes C 0 to 345 ° (with a step of 15 °) of the angle gamma from 0 to 180 ° (in steps of 5 °). The measured data were processed by zonal flow and through programs LumiDISP and Matlab. The partial result of this thesis is to verify whether it is possible to use the luminance analyzer for obtaining luminosity curves, it means, if the luminosity curve obtained through luminance analyzer will comply with the curves obtained through a luxmeter. Further work should ascertain the feasibility of acquired photographs lamps from a very close photometric distance could create luminosity curve for any location and distance from the observer to measured lamps.
12

Nejistoty měření ve fotometrii / Measurement uncertainties in photometry

Motyčka, Martin January 2016 (has links)
This master's thesis is focused on problematic of measurent unceartainties in photometry. Theoretical part describes photometric measururing instruments, their uncearnities and limitations. In the second part of this thesis there is a mathematical description of calculating uncearnities in laboratory conditions. In practical part there are calculations of uncearnities for photometric instruments at light laboraty VUT Brno.
13

Měření kvality osvětlení na operačních sálech / Measurement of operating room lights quality

Rovná, Tereza January 2016 (has links)
This thesis is focused on measuring the quality of lighting in operating rooms. Operating lights are very demanding in terms of quality requirements for each parameter, so it is important to specify exactly these parameters and check them regurarly. To measure the quality of the light source, was used a special kit from Maquet. Measurement procedure was not as accurate as it was for operating lighting need, therefore, this work includes a proposal to improve the measurement of quality lighting in operating theaters. In cooperation with University Hospital Brno Bohunice University Hospital Motol and the company Maquet measured nine operating lights, each light were compared in terms of parameters such as maximum light intensity, light distribution in the surgical field. In each category were selected several lighting, which reached the best results. The various parameters were compared with values declared by the manufacturer.
14

Pozorování zdrojů gama záření a kalibrace observatoře Cherenkov Telescope Array / The observations of gamma ray sources and calibration of the Cherenkov Telescope Array Observatory

Juryšek, Jakub January 2020 (has links)
In this thesis, we present the Monte Carlo study of two prototypes of tele- scopes for the Cherenkov Telescope Array (CTA) observatory, followed by the first data analysis partially using our reconstruction pipeline based on Random Forests. The Monte Carlo model of the SST-1M prototype is created and val- idated by comparison with data. Using the precise Monte Carlo models, we evaluate the performance of the SST-1M and LST-1 prototypes, working so-far in mono-regime as standalone telescopes, resulting in their energy and angular resolution, and the differential sensitivity. We also present an analysis of the data from the first two Crab Nebula observation campaigns conducted with the LST-1 telescope. In the last part of the thesis, we present a study of aerosol optical depth of the atmosphere above both future sites of the CTA observa- tory, retrieved from photometric measurements of Sun/Moon photometers. We focus on the photometer in-situ calibration for nocturnal measurements and introduce corrections to minimize systematic shifts between diurnal and noc- turnal measurements. Using the developed methods, we present the aerosol characterization of both CTA sites based on the photometric data. 1
15

Fotometrie a spektroradiometrie zapouzdřených LED čipů / Photometry and spectroradiometry of LEDs

Vysoudil, Martin January 2012 (has links)
This thesis deals with the processing of light technical parameters and performance of key LED chips for their applications in lighting systems. The aim is to create a laboratory model for measuring the qualitative and quantitative parameters of highly luminous light LED emitted depending on the angle, using a spherical integrator 0.3 m, goniometer and fiber spektroradiometr /luxmeters. Goniometer is designed using modular optomechanical parts company Thorlabs. Due to the current passing through the LED chips heat up considerably. To light LED chip parameters tested were not affected by heat from the chip is required to pay the heat generated by a passive radiator. Another part of this thesis is the reconstruction of an older model spherical integrator. Reconstruction must be undertaken so as to ensure sufficient cooling again tested LEDs. Light scattered in the ball of the integrator is led by the optical cable to the spektroradiometr that are subsequently recorded its parameters. The second element used to measure the light produced by the LED source is photocell. Spherical integrator must be appropriately modified to indicate the two measuring elements and also meet the standards of determining the correctness of measurement. At the end of the measurement results will be compared with catalog values provided by the manufacturer.