• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A Wireless, Fully-Passive Recorder for Medical Applications

Lee, Cedric W. January 2016 (has links)
No description available.
2

Fully-passive Wireless Acquisition of Biosignals

January 2020 (has links)
abstract: The recording of biosignals enables physicians to correctly diagnose diseases and prescribe treatment. Existing wireless systems failed to effectively replace the conventional wired methods due to their large sizes, high power consumption, and the need to replace batteries. This thesis aims to alleviate these issues by presenting a series of wireless fully-passive sensors for the acquisition of biosignals: including neuropotential, biopotential, intracranial pressure (ICP), in addition to a stimulator for the pacing of engineered cardiac cells. In contrast to existing wireless biosignal recording systems, the proposed wireless sensors do not contain batteries or high-power electronics such as amplifiers or digital circuitries. Instead, the RFID tag-like sensors utilize a unique radiofrequency (RF) backscattering mechanism to enable wireless and battery-free telemetry of biosignals with extremely low power consumption. This characteristic minimizes the risk of heat-induced tissue damage and avoids the need to use any transcranial/transcutaneous wires, and thus significantly enhances long-term safety and reliability. For neuropotential recording, a small (9mm x 8mm), biocompatible, and flexible wireless recorder is developed and verified by in vivo acquisition of two types of neural signals, the somatosensory evoked potential (SSEP) and interictal epileptic discharges (IEDs). For wireless multichannel neural recording, a novel time-multiplexed multichannel recording method based on an inductor-capacitor delay circuit is presented and tested, realizing simultaneous wireless recording from 11 channels in a completely passive manner. For biopotential recording, a wearable and flexible wireless sensor is developed, achieving real-time wireless acquisition of ECG, EMG, and EOG signals. For ICP monitoring, a very small (5mm x 4mm) wireless ICP sensor is designed and verified both in vitro through a benchtop setup and in vivo through real-time ICP recording in rats. Finally, for cardiac cell stimulation, a flexible wireless passive stimulator, capable of delivering stimulation current as high as 60 mA, is developed, demonstrating successful control over the contraction of engineered cardiac cells. The studies conducted in this thesis provide information and guidance for future translation of wireless fully-passive telemetry methods into actual clinical application, especially in the field of implantable and wearable electronics. / Dissertation/Thesis / Doctoral Dissertation Electrical Engineering 2020
3

Influence of the sweep angle on the leading edge vortex and its relation to the power extraction performance of a fully-passive oscillating-plate hydrokinetic turbine prototype

Lee, Waltfred 01 March 2021 (has links)
Oscillating-foil hydrokinetic turbines have gained interest over the years to extract energy from renewable sources. The influence of the sweep angle on the performance of a fully-passive oscillating-plate hydrokinetic turbine prototype was investigated experimentally in the present work. The sweep angle was introduced to promote spanwise flow along the plate in order to manipulate the leading edge vortex (LEV) and hydrodynamically optimize the performance of the turbine. In the present work, flat plates of two configurations were considered: a plate with a 6° sweep angle and an unswept plate (control), which were undergoing fully-passive pitch and heave motions in uniform inflow at the Reynolds numbers ranging from 15 000 to 30 000. The resulting kinematic parameters and the energy extraction performance were evaluated for both plates. Planar (2D) particle image velocimetry (PIV) was used to obtain patterns of the phase-averaged out-of-plane vorticity during the oscillation cycle. The circulation in the wake was then related to the induced-forces on the plate by calculating the moments of vorticity of the LEV with respect to the pitching axis of the plate. Tomographic (3D) PIV was implemented in evaluating the influence of the spanwise flow on the dynamics of the vortex structure in three-dimensional space. The rate of deformation of the vortex length was quantified by calculating the deformation terms embedded in the vorticity equations, then linked to the stability of the vortex. The results show evidence of delay of the shedding of LEV and increased vortex stability, in the case of the swept plate. The manipulation of the LEV by the spanwise flow was related to the induced kinematics exhibited by the prolonged heave forces experienced by the swept plate, which led to the higher power extraction performance at high inflow velocities. In the presence of spanwise flow, positive vortex stretching along the vortex line increased the stabilization of the vortex core and prevented the onset of helical vortex breakdown, observed in the case of the unswept plate. The use of the sweep profile on the plate has led to the improvement of energy extraction performance of the fully-passive hydrokinetic turbine. / Graduate

Page generated in 0.0476 seconds