• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 294
  • 290
  • 44
  • 33
  • 23
  • 16
  • 12
  • 10
  • 7
  • 7
  • 5
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 863
  • 224
  • 200
  • 199
  • 139
  • 126
  • 111
  • 111
  • 108
  • 100
  • 82
  • 81
  • 80
  • 77
  • 61
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Role of physiochemical parameters in the osteogenic potential of calcium phosphate biomaterials

Campion, Charlie January 2015 (has links)
The number of clinical procedures performed in the USA using bone graft substitutes was estimated at 1.1 million in 2010 and is projected to reach 1.3 million in 2015. This increasing demand for bone graft substitutes is a result of an ever-ageing population coupled with recent reports in the clinical literature of concerns regarding the safety of allograft and recombinant bone morphogenetic proteins such as rh- BMP-2 and the supply of autograft, which has led to an increased clinical interest in synthetic alternatives to allograft; autograft; and recombinant growth factors. One such synthetic material is silicate-substituted hydroxyapatite (SiCaP). Mechanical testing revealed SiCaP to have similar mechanical behaviour to morcellised cancellous bone. In computated spinal and hip models the simulated stresses in SiCaP were determined to be low when in situ, indicating a stressshielding effect from the implanted metalwork and surrounding bone. We also found an inverse relationship between porosity and Young's Modulus. Our results indicated that the strut-porosity of a material substrate should be increased to maximise the potential for formation of a precursor to bone-like apatite after implantation in osseous defects and further confirmed previous reports that betatricalcium phosphate is less bioactive than hydroxyapatite. We demonstrated a direct link between the amount of strut-porosity and the osteoinductivity of SiCaP. We learned that adding a resorbable carrier phase did not impair the osteoinductive potential of SiCaP, suggesting that osteoinductivity is not necessarily determined in the first 24-48 hours post implantation. Most notably from our studies we determined that the osteoinductivity of SiCaP correlated with its performance in orthotopic defects. Our research confirmed our hypothesis that modifying the micron-scale physical structure of a hierarchical porous SiCaP based biomaterial influences its functional performance in vitro and such modifications can be applied to improve its performance outcomes in ectopic and orthotopic treatment sites in vivo.
42

Effects of Irradiation on Grafted Skin : Vascular Changes after Irradiation

OKA, TOHRU, KANEDA, TOSHIO, UEDA, MINORU, SUMI, YASUNORI 01 1900 (has links)
No description available.
43

Graft copolymer micelles and surface modification with polymer micelles /

Ma, Yanhui, January 2000 (has links)
Thesis (Ph. D.)--University of Texas at Austin, 2000. / Vita. Includes bibliographical references (leaf 115). Available also in a digital version from Dissertation Abstracts.
44

Development of an in vivo device to investigate the effect of mechanical load on allograft remodeling

Jamieson, Miranda Lindsay 11 1900 (has links)
Failure of a primary hip arthroplasty is often caused by osteolysis which compromises the patient’s periprosthetic bone stock. Impaction allografting involves the use of morselized allograft bone and cement to stabilize the implant and restore this periprosthetic bone stock. Although clinical results of impaction allografting are favourable, regions of necrotic bone graft have been shown to exist for many years post-operatively and may ultimately lead to implant failure. Previous laboratory research has identified a correlation between mechanical stimuli and bone growth; therefore, the purpose of this study was to develop an in vivo device that would enable the investigation of the effect of mechanical load on bone graft incorporation in impacted allograft hip prostheses. An actuator was developed with a finite volume to enable its subcutaneous implantation along the tibia (20mm x 10mm x 10mm) and spine (35mm x 25mm x 15mm) in a rat bone chamber model. The actuator was designed to deliver a dynamic, (1Hz), compressive, (-6N), load that was controlled telemetrically throughout a 6-week long in vivo study. Independent validations of the mechanical actuator and the electrical control system were performed prior to an electromechanical validation of the integrated system. The responsiveness, quantity and magnitude of the load were investigated. The mechanical actuator was motor-driven and the electrical control system was based on radio frequency signal transmission. The electromechanical actuator conformed to the volumetric restrictions of the rat bone chamber model (tibia: 13mm x 17mm x 10mm; spine: 35mm x 30mm x 11mm). A wide range of operating frequencies (0.5 to 3.0 ± 0.05Hz) was achieved and a telemetrically controlled load was produced for 20 seconds per day throughout a simulated 6 week in vivo study. Due to inefficiencies of the mechanical actuator and voltage limitations of the control system, the magnitude of the compressive load produced by the actuator (-1.67 ± 0.10N) was less than specified by the design criteria. Future work to optimize the actuator design and fabrication is warranted in order to increase the maximum load magnitude; however, the current design provides a novel means to begin the investigation of the role of mechanical load on bone graft incorporation in impaction allografting.
45

Development of an in vivo device to investigate the effect of mechanical load on allograft remodeling

Jamieson, Miranda Lindsay 11 1900 (has links)
Failure of a primary hip arthroplasty is often caused by osteolysis which compromises the patient’s periprosthetic bone stock. Impaction allografting involves the use of morselized allograft bone and cement to stabilize the implant and restore this periprosthetic bone stock. Although clinical results of impaction allografting are favourable, regions of necrotic bone graft have been shown to exist for many years post-operatively and may ultimately lead to implant failure. Previous laboratory research has identified a correlation between mechanical stimuli and bone growth; therefore, the purpose of this study was to develop an in vivo device that would enable the investigation of the effect of mechanical load on bone graft incorporation in impacted allograft hip prostheses. An actuator was developed with a finite volume to enable its subcutaneous implantation along the tibia (20mm x 10mm x 10mm) and spine (35mm x 25mm x 15mm) in a rat bone chamber model. The actuator was designed to deliver a dynamic, (1Hz), compressive, (-6N), load that was controlled telemetrically throughout a 6-week long in vivo study. Independent validations of the mechanical actuator and the electrical control system were performed prior to an electromechanical validation of the integrated system. The responsiveness, quantity and magnitude of the load were investigated. The mechanical actuator was motor-driven and the electrical control system was based on radio frequency signal transmission. The electromechanical actuator conformed to the volumetric restrictions of the rat bone chamber model (tibia: 13mm x 17mm x 10mm; spine: 35mm x 30mm x 11mm). A wide range of operating frequencies (0.5 to 3.0 ± 0.05Hz) was achieved and a telemetrically controlled load was produced for 20 seconds per day throughout a simulated 6 week in vivo study. Due to inefficiencies of the mechanical actuator and voltage limitations of the control system, the magnitude of the compressive load produced by the actuator (-1.67 ± 0.10N) was less than specified by the design criteria. Future work to optimize the actuator design and fabrication is warranted in order to increase the maximum load magnitude; however, the current design provides a novel means to begin the investigation of the role of mechanical load on bone graft incorporation in impaction allografting.
46

Islet xenograft rejection : studies in the pig-to-rodents and pig-to-primate models /

Wennberg, Lars, January 1900 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst. / Härtill 5 uppsatser.
47

Synthesis and characterization of perfectly alternating segmented copolymers comprised of poly(dimethylsiloxane)s and engineering thermoplastics /

Smith, Susan Abenes, January 1991 (has links)
Thesis (M.S.)--Virginia Polytechnic Institute and State University, 1991. / Vita. Abstract. Includes bibliographical references (leaves 178-180). Also available via the Internet.
48

Oligopeptide-functionalized graft copolymers synthesis and applications in nucleic acid delivery /

Breitenkamp, Rebecca Boudreaux, January 2009 (has links)
Thesis (Ph. D.)--University of Massachusetts Amherst, 2009. / Includes bibliographical references (p. 98-107). Print copy also available.
49

Carotis-TEA mit Reinseration in die Arteria carotis externa, eine neue OP-Variante. Vergleich mit den bisherigen Standardverfahren

Gabsch, Uwe, January 2007 (has links)
Ulm, Univ., Diss., 2007.
50

Synthesis and characterization of graft and block copolymers using hydroboration /

Baleg, Abd-Almonam. January 2006 (has links)
Thesis (MSc)--University of Stellenbosch, 2006. / Bibliography. Also available via the Internet.

Page generated in 0.0487 seconds