Magnétomètres à pompage optique à Hélium 4 : développement et preuve de concept en magnétocardiographie et en magnétoencéphalographie / Helium 4 optically-pumped magnetometers : development and proof of concept in magnetocardiography and magnetoecephalographyCorsi, Marie-Constance 12 October 2015 (has links)
La magnétocardiographie (MCG) et la magnétoencéphalographie (MEG) sont deux techniques d'imagerie non-invasives mesurant respectivement les champs magnétiques cardiaques et cérébraux. Les dispositifs actuels utilisent des capteurs supraconducteurs de haute performance mais nécessitant un dispositif de refroidissement cryogénique, engendrant de fortes contraintes tant techniques que financières. Les magnétomètres à pompage optique (OPM) tendent à constituer une réelle alternative. Parmi eux figurent ceux développés au CEA-LETI, basés sur l'utilisation de l'hélium 4. Cette thèse a pour objectif de développer des magnétomètres vectoriels à 4He (fonctionnant à température ambiante) dédiés aux applications MCG et MEG.Après une optimisation des paramètres-clés d'un prototype non-miniaturisé préexistant, une sensibilité inférieure à 100 fT/sqrt(Hz) a pu être obtenue suivant deux axes. Afin de respecter les besoins spécifiques de la MCG et de la MEG une étape de miniaturisation a dû être menée et une architecture gradient-métrique a été mise en place. Parallèlement, des tests précliniques menés à Clinatec nous ont permis de concevoir un nouveau conditionnement du prototype, ainsi qu'un système réduisant les perturbations magnétiques. Une analyse des principales sources de bruit a révélé que les deux principaux contributeurs au bruit sont le laser et le système de décharge HF. Nous avons ainsi envisagé plusieurs pistes d'amélioration du niveau de bruit dont une nouvelle technique de détection. Le prototype issu de ces travaux comporte une pièce élémentaire (la cellule) d'un centimètre de côté, et présente une sensibilité intrinsèque de 350 fT/sqrt(Hz).Le dispositif a ensuite été testé avec succès dans le cadre de mesures MCG sur un sujet sain, précédées de tests sur fantôme ayant permis de prouver l'opérabilité de nos capteurs dans un environnement clinique. Par ailleurs, la reproductibilité des résultats ainsi que la possibilité de réduire à 30 s le temps d'acquisition des données ont pu être démontrées. Une optimisation spécifique de la partie optique du prototype a permis d'obtenir une sensibilité de l'ordre de 210 fT/sqrt(Hz) entre 3 et 300 Hz, compatible avec l'application MEG. Après des tests menés avec succès sur fantôme, trois séries d'essais ont été réalisées sur un sujet sain. Nous avons pu ainsi détecter des potentiels évoqués auditifs, visuels ainsi qu'une modulation de l'activité cérébrale spontanée sous l'effet de l'ouverture des paupières. L'ensemble des résultats obtenus constitue les premières preuves de concept cliniques du dispositif en MCG et MEG. / Magnetocardiography (MCG) and magnetoencephalography (MEG) are non-invasive techniques consisting in measuring respectively cardiac and brain magnetic fields. Despite their performance, the sensors currently used need a cryogenic cooling system which engenders technical and financial constraints. New cryogenic-free sensors have recently emerged: the OPMs (Optically-Pumped Magnetometers). Among them, vector 4He magnetometers developed by CEA-LETI which work at room-temperature. This thesis is focused on the development of 4He magnetometers dedicated to MCG and MEG.After having optimized the key-parameters of a first non-miniaturized prototype, a sensitivity inferior to 100 fT/sqrt(Hz) has been obtained along two axes. In order to meet biomedical constraints, a miniaturization of the device has been processed. In parallel, preclinical tests were carried out which have enabled us to design a gradiometer mode, a new packaging, and a magnetically isolated system. A noise analysis revealed that laser and HF discharge were the main sources of disturbance, and lead us to consider improvements such as a new detection mode. Eventually, a sensor, with a 1cm-sided cell, and an intrinsic sensitivity of 350 fT/√Hz has been developed.Then, device has been successfully tested in the frame of the MCG application from a healthy subject, preceded by a simulation study with a phantom which enables us to demonstrate its operability within a clinical environment. Moreover, we have proved the reproducibility of the measurements and the possibility to detect the main features of the cardiac cycle within a 30 s recording time. A specific optimization of the optical part has enabled us to obtain a 210 fT/sqrt(Hz) sensitivity between 3 and 300 Hz, suitable for the MEG application. After having tested our device with a phantom, three MEG experiments were performed with a healthy subject: auditory evoked field, visual evoked field and spontaneous activities have been detected. The obtained results form the first clinical proof of concept of the device for MCG and MEG applications.
|
2 |
Polarisation par pompage optique d'hélium 3 liquide pur ou en solution dans l'hélium 4, en dessous de 500mKCornut, Myriam 24 February 1993 (has links) (PDF)
No description available.
|
3 |
Structure microscopique et dynamique des vortex dans un superfluide denseVillerot, Sophie 27 November 2012 (has links) (PDF)
L'étude des vortex trouve sa justification dans le rôle que ces derniers jouent dans la turbulence quantique. L'équation de Gross-Pitaevskii ne peut pas nous permettre de modéliser convenablement l'Hélium superfluide, mais on peut l'utiliser pour obtenir le paramètre d'ordre d'un superfluide modèle, ayant le maximum de propriétés en commun avec l'Hélium, notamment une courbe de dispersion identique, par la modification du terme d'interactions.En supposant que le minimum roton influence l'essentiel de la physique, on détermine la forme du paramètre d'ordre loin de la perturbation créée par le vortex rectilinéaire axisymétrique par deux approches différentes - il apparaît alors que seuls deux paramètres sont nécessaires pour caractériser entièrement le profil.Le modèle proposé par Pomeau-Rica, qui offre la possibilité d'étudier le superfluide près de la cristallisation, met en lumière l'impact de la profondeur du minimum roton sur l'amplitude des oscillations. Par comparaison avec les résultats obtenus ab initio par Reatto, les résultats donnés par le modèle de Berloff-Roberts exhibent un déphasage marqué, qui semble être une conséquence non-physique de la forme du spectre d'excitation. Les calculs énergétiques laissent à penser que les oscillations portent une faible fraction de l'énergie du vortex, l'énergie cinétique dominant.Le calcul du paramètre d'ordre est effectué pour un anneau de grande taille par rapport à la distance interatomique, à vitesse nulle et à vitesse non-nulle. La détermination des énergies potentielle et cinétique permet d'accéder à la vitesse maximale atteinte par l'anneau en fonction de son rayon et de la comparer à la vitesse critique de Landau.
|
4 |
Cryoréfrigérateur à tube à gaz pulsé pour applications spatiales travaillant à basses températures (4K-10K) / Pulse tube cryocooler for space applications working at low temperatures (4K-10K)Charrier, Aurélia 02 October 2015 (has links)
Certaines missions d'astrophysique embarquent des détecteurs infrarouges ou X qui sont refroidis à des températures subkelvin via un système cryogénique qui comporte soit un bain d'hélium (comme pour Herschel), soit un réfrigérateur Joule-Thomson (comme pour Planck) pour le pré-refroidissement de l'étage subkelvin. Un doigt froid à tube à gaz pulsé ayant les mêmes performances qu'un Joule-Thomson pourrait offrir un certain nombre d'avantages pour les futures chaines cryogéniques (pas de pré-refroidissement nécessaire, simplicité d'intégration, fiabilité accrue).L'objectif de cette thèse concerne l'étude et la réalisation d'un doigt froid à tube à gaz pulsé 4K qui pourrait remplacer une machine Joule-Thomson. Deux principaux axes d'étude ont été menés parallèlement : des études sur les matériaux régénérateur et des études de performances. Des développements technologiques portant sur le régénérateur (étude et mise en forme de différents matériaux ayant des anomalies de chaleur spécifique à basse température) ont été menés afin d'améliorer les performances d'un doigt froid à tube à gaz pulsé haute fréquence (30Hz) travaillant avec de l'hélium 4.Cette thèse a permis d'obtenir la meilleure performance mondiale en terme de température limite en utilisant de l'hélium 4 et avec un pré-refroidissement à 20K. Une température limite de 3,86K a été obtenue et une puissance froide de 25mW est disponible à 5K. Cette thèse a également permis d'étudier l'effet du gaz réel sur le comportement de la machine, en particulier grâce à des mesures de profils de température du régénérateur. Cinq configurations différentes de régénérateur (variation de la répartition de chaleur spécifique le long du régénérateur froid) ont été testées. Elles ont permis de mieux comprendre le rôle de la répartition de la chaleur spécifique dans le régénérateur. Ces différentes mesures ont été complétées avec des études de fluctuations de températures pariétales réalisées à l'aide d'une centrale d'acquisition rapide (toutes les millisecondes). / Some astrophysics missions embark infrared or X detectors which are cooled down to subkelvin temperatures using a cryogenic cooling system that features helium bath (like for the Herschel satellite) or a Joule-Thomson cryocooler (like for the Planck satellite) for the precooling of the subkelvin cooling stage. A pulse tube cold finger which would have the same performances as a Joule-Thomson cryocooler could offer some advantages for future cryogenic chains (no need of precooling, simplicity of integration, increased reliability).The goal of this PhD is the making and the study of a pulse tube cold finger working at temperature around 4K which could replace a Joule-Thomson cryocooler. Two main lines have been worked on simultaneously : studies on materials for the cold regenerator and studies on the cold finger performances. Technological developments on the cold regenerator (including study and shaping of different materials with specific heat anomalies at low temperature) have been performed to enhance the performances of a cold finger working at high frequency (30Hz) with helium 4.The work done during this PhD led to the best no-load temperature never achieved using helium 4 and with a precooling of 20K. A no-load temperature of 3.86K has been obtained and 25mW of cooling power are available at 5K. In addition the effect of real gas on the cryorefrigerator operation has been studied in particular thanks to the measurement of regenerator thermal profiles. Five configurations with different regenerator fillings (variation of the distribution of the specific heat along the cold regenerator) have been tested. These five tests led to a better understanding of the role of the distribution of the specific heat in the regenerator. These measurements have been completed with studies of regenerator wall temperature fluctuations recorded thanks to a fast data acquisition system (each millisecond).
|
5 |
Réalisation d'un laser LNA monomode et asservi sur la transition 23S1-23P de l'hélium 4 (1083nm): utilisation pour quelques expériences de refroidissement radiatif d'atomes d'hélium 4 métastableVansteenkiste, Nathalie 03 October 1989 (has links) (PDF)
Ce mémoire présente quelques expériences de refroidissement radiatif transverse d'un jet d'hélium 4 métastable sur la transition 23S → 2 3P . Une première partie est consacrée à la description du laser à solide (LNA), en anneau, monomode et asservi sur la raie atomique à 1.083 micron de l'hélium, qui a été construit pour ces expériences. La seconde partie décrit quelques expériences de refroidissement radiatif transverse d'un jet d'hélium métastable qui ont été réalisées avec ce laser ; on y présente en particulier une expérience utilisant un piégeage cohérent de population ("résonance noire") sélectif en vitesse, qui a permis d'atteindre une température à une dimension de 2 microKelvins, inférieure à l'énergie de recul d'un seul photon.
|
6 |
Laser LNA de puissance, application au pompage optique de l'hélium-3 et des mélanges hélium-3/hélium-4Larat, Christian 25 October 1991 (has links) (PDF)
No description available.
|
7 |
Contributions à l'étude expérimentale de l'hélium-3 liquide polariséVillard, Bérengère 14 October 1999 (has links) (PDF)
L'héhum-3 liquide polarisé est préparé par pompage optique laser de l'hélium-3 pur dans un champ magnétique faible et à température ambiante, suivi d'une liquéfaction rapide de l'échantillon polarisé. La mise en oeuvre d'un nouveau cryostat à hélium-3 nous a permis d'obtenir des échantillons d'hélium-3 liquide dont le taux de polarisation atteint 25 %, à des températures de l'ordre de 0.5 K très bien stabilisées. Cette stabilité nous a permis d'étudier l'influence de la polarisation nucléaire sur l'équilibre liquide-vapeur, et en particulier sur la pression de vapeur saturante. Nous avons développé dans ce but des capteurs capacitifs très sensibles. Une estimation (limitée à l'ordre le plus bas en M^2) des effets attendus suite à une brutale destruction de l'aimantation M est menée. Ces effets sont expérimentalement observés dans les mélanges hélium-3/hélium-4 ; dans l'hélium-3 pur, seule une augmentation transitoire et faible de la pression a pu être observée. Nous décrivons ensuite une expérience préliminaire visant à déterminer le temps de relaxation longitudinale T1 dans les mélanges isotopes. La relaxation sur les parois de la cellule est efficacement réduite par l'utilisation d'un enduit de césium et des temps de l'ordre de 20 minutes sont observés. Nous nous sommes interessés plus particulièrement à la détermination de la concentration en hélium-3 en phase liquide Enfin, nous étudions expérimentalement l'effet du champ dipolaire sur l'évolution de l'aimantation transverse dans nos échantillons liquides fortement aimantés. Nous observons la précession libre de l'aimantation après une impulsion RMN et analysons de façon détaillée son temps d'amortissement en fonction de divers paramètres. Ce temps varie de façon spectaculaire avec l'angle de basculement, effet qui pourrait être lié à des instabilités dynamiques de RMN.
|
8 |
Structure microscopique et dynamique des vortex dans un superfluide dense / Microscopic structure and Dynamics of Vortices in a dense SuperfluidVillerot, Sophie 27 November 2012 (has links)
L’étude des vortex trouve sa justification dans le rôle que ces derniers jouent dans la turbulence quantique. L’équation de Gross-Pitaevskii ne peut pas nous permettre de modéliser convenablement l’Hélium superfluide, mais on peut l’utiliser pour obtenir le paramètre d'ordre d’un superfluide modèle, ayant le maximum de propriétés en commun avec l’Hélium, notamment une courbe de dispersion identique, par la modification du terme d’interactions.En supposant que le minimum roton influence l’essentiel de la physique, on détermine la forme du paramètre d’ordre loin de la perturbation créée par le vortex rectilinéaire axisymétrique par deux approches différentes - il apparaît alors que seuls deux paramètres sont nécessaires pour caractériser entièrement le profil.Le modèle proposé par Pomeau-Rica, qui offre la possibilité d’étudier le superfluide près de la cristallisation, met en lumière l’impact de la profondeur du minimum roton sur l’amplitude des oscillations. Par comparaison avec les résultats obtenus ab initio par Reatto, les résultats donnés par le modèle de Berloff-Roberts exhibent un déphasage marqué, qui semble être une conséquence non-physique de la forme du spectre d’excitation. Les calculs énergétiques laissent à penser que les oscillations portent une faible fraction de l’énergie du vortex, l'énergie cinétique dominant.Le calcul du paramètre d’ordre est effectué pour un anneau de grande taille par rapport à la distance interatomique, à vitesse nulle et à vitesse non-nulle. La détermination des énergies potentielle et cinétique permet d’accéder à la vitesse maximale atteinte par l’anneau en fonction de son rayon et de la comparer à la vitesse critique de Landau. / Vortices study's justification lays in the fact that those former play an important part in quantum turbulence. The Gross-Pitaevskii equation can't be a proper model for superfluid helium, but we can still use it to determine the order parameter of a theoretical superfluid, which has then the maximum amount of properties in common with liquid helium, and in particular, the same dispersion relation, thus gained by modifying the interaction terms.We then make the assumption that all the physical properties of the superfluid are triggered by the existence of the roton minimum, which allows us to calculate the order parameter far from the perturbation created by an axisymmetric rectilinear vortex, using two different methods. At that point, it appears that only two parameters are needed to fully characterize vortex profil.Pomeau-Rica's model offers the possibility to study the superfluid near crystallization and reveals the influence of the roton minimum's shape and depth on oscillations' amplitude. Results are subsequently compared to those given by Reatto's ab initio calculations. In Berloff-Roberts' model, profil displays a strong phase shift, which seems to be a non-physical consequence of the dispersion relation's shape at high frequencies. Energies reckoning leads us to think that oscillations carry a small fraction of the total vortex' energy, meaning that the kinetic energy is dominant.The order parameter for a vortex ring, whose radius is much larger than the interatomic distance, is calculated at zero and nonzero speed. Potential and kinetic energies are estimated and help us obtain the maximal speed reached by such a ring, depending on its radius and finally discussed this speed in regard to the Landau critical speed.
|
9 |
Conception, réalisation et application d'un magnétomètre atomique vectoriel / Design, realization and application of a vector atomic magnetometerLe Prado, Matthieu 23 January 2014 (has links)
Plusieurs technologies de magnétomètres atomiques ont été développées depuis les années 60. Afin d’obtenir une technologie capable de mesurer des champs magnétiques inférieurs à 50 nT et compatible avec notre magnétomètre scalaire isotrope, nous avons du concevoir un magnétomètre atomique dans une configuration qui n'a jamais été publiée.Nous avons calculé les résonances caractéristiques de ce magnétomètre et réalisé un prototype. Son bruit est inférieur à 1 ou 0.1 pT/√Hz, respectivement pour les versions tri axiales ou mono-axiales.Une façon de réduire le bruit du magnétomètre de 7 dB a été identifiée et le principe de ce magnétomètre pourrait offrir d’intéressantes perspectives pour les horloges atomiques. / Several technologies of atomic magnetometers have been developed since the60s. To obtain a technology capable of measuring magnetic fields lower than 50 nT and compatible with our isotropic scalar magnetometer, we had todevelop an atomic magnetometer in a configuration that has never been published.We calculated the resonances characteristic of the magnetometer with the formalism of the dressed atom and realized a prototype. The noise of the resulting magnetometer is lower than 1 or 0.1 pT/√Hz, on the monoaxial or triaxial versions respectively.One way to reduce the noise of the magnetometer of 7 dB has been identified and the principle of this magnetometer could offer interesting perspectives for atomic clocks.
|