• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 2
  • Tagged with
  • 5
  • 5
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Imagerie dynamique et vélocimétrie IRM des gaz hyperpolarisés

De Rochefort, Ludovic 07 June 2006 (has links) (PDF)
Ce travail s'inscrit dans le cadre du projet RNTS R-MOD qui visait le développement d'un simulateur morpho-fonctionnel des voies respiratoires. Des méthodes de visualisation et de quantification de flux gazeux pulmonaires par IRM des gaz hyperpolarisés (GHP) ont été développées pour pouvoir valider les résultats du simulateur.<br />Pour atteindre cet objectif, un système adapté à l'environnement spécifique de l'IRM a été développé pour permettre l'administration de GHP de manière contrôlée, et différentes approches d'imagerie du flux de GHP ont été explorées.<br />La 1ère approche est basée sur de l'imagerie dynamique de l'inspiration de GHP. Ce type d'expérience est analysé. L'évolution du phénomène est trop rapide pour être observée correctement avec les techniques actuelles. Néanmoins, un état d'équilibre dynamique de la répartition spatiale de l'aimantation dans les poumons lors d'inspirations en régime stationnaire est observable. Les paramètres dont dépend cet équilibre et une partie de ce qui peut être quantifié par le biais de ce type d'expérience ont été formalisés et les concepts introduits ont été validés par différentes expériences d'imagerie dynamique.<br />La 2ième approche, quantitative, est basée sur la vélocimétrie par contraste de phase combinée à l'imagerie radiale rapide. D'abord validée quantitativement sur des fantômes d'écoulement connus (tube droit, coude, bifurcation), la technique a ensuite été appliquée sur un modèle réaliste d'arbre bronchique et comparée à une simulation numérique des écoulements. Les 3 composantes de la vitesse ont été mesurées en environ 1 s avec une résolution spatiale du mm et une précision du cm•s-1. Enfin, la faisabilité in vivo de la mesure de vitesse dans les voies aériennes pulmonaires a été démontrée dans la trachée lors d'une inspiration.<br />Cet outil de caractérisation des écoulements à l'aide de l'IRM des GHP ouvre des voies prometteuses aussi bien pour la physique des écoulements que pour les applications médicales.
2

Diffusion de l'hélium-3 hyperpolarisé dans le tissu pulmonaire : évaluation par différentes techniques IRM

Habib, Dayane 24 September 2007 (has links) (PDF)
Ce travail présente une étude expérimentale sur l'effet de la diffusion restreinte de l'hélium-3 hyperpolarisé dans l'acinus pulmonaire effectuée à bas champ magnétique 0,1 T. Plusieurs fantômes avec différentes tailles et connections modélisant l'acinus humain sain et à un stade précoce de l'emphysème ont été réalisés selon le modèle de Kitaoka. L'atténuation du signal dévie par rapport au comportement prévu de décroissance exponentielle en G2, G étant l'intensité de gradient. Cette observation indique une certaine ambiguïté sur la possibilité de quantifier de façon absolue le coefficient de diffusion apparent (ADC), sauf dans la limite G faible. Des simulations Monte-Carlo sont en bon accord avec les mesures. Des séquences originales rapides basées sur le principe des échos de spin multiples ont été développées, pour accéder à une valeur globale d'ADC à des temps longs permettant l'exploration du gaz dans toute la structure de branchement de l'acinus. Des mesures sur un modèle animal d'emphysème (rat) ont été comparées à des cartes obtenues à partir d'acquisitions standard avec petits angles de basculement, elles indiquent une augmentation systématique et toujours significative des ADC par rapport au contrôle sain, pour plusieurs protocoles de mesure. La méthode globale a une meilleure sensibilité que la cartographie standard, en outre elle donne un plus fort contraste d'ADC entre animaux sains et avec emphysème du fait de la possibilité d'employer des valeurs de G plus faibles. Ces outils de mesure de diffusion par IRM et RMN des gaz hyperpolarisés ouvrent des voies prometteuses aussi bien pour la physique de la diffusion que pour les applications médicales.
3

Helium-3 Magnetic Resonance Elastography of the lung / Elastographie des poumons par résonance magnétique de l’hélium-3 hyperpolarisé

Santarelli, Roberta 27 February 2013 (has links)
Selon l'American Lung Association, dans les dernières années, les maladies pulmonaires sont devenues la troisième cause mondiale de décès après les maladies cardiovasculaires et le cancer. Et il est prévu que la position augmente dans ce classement au cours des dix prochaines années. Les maladies pulmonaires telles que la broncho-pneumopathie chronique obstructive (BPCO) et la fibrose interstitielle affectent des millions de personnes dans le monde, tuant des milliers d'entre eux chaque année tandis que de nouveaux cas sont signalés. Aujourd'hui, il n'y a pas de diagnostic précoce des maladies pulmonaires. Celles-ci se manifestent essentiellement par une modification des propriétés viscoélastiques du parenchyme pulmonaire qui ne peut être détectée par les techniques usuelles appliquées généralement sur les autres organes. La tomodensitométrie par rayons X et la biopsie pulmonaire chirurgicale peuvent indiquer la maladie. Cependant, il n'est pas encore possible de prédire la progression de cette dernière ni de déterminer la durée optimale de la thérapie, ni encore d'explorer l'administration d'autres agents potentiellement moins toxiques que ceux utilisés de nos jours. Les causes et les mécanismes de la maladie ainsi que les facteurs génétiques associés ne sont pas encore déterminés. Les enjeux sociétal et médical sont énormes. Les propriétés viscoélastiques des tissus pulmonaires jouent un rôle clé dans la fonction-même de l'organe. Elles pourraient être des biomarqueurs pulmonaires très sensibles puisqu'elles dépendent de la structure des tissus, des conditions biologiques, et qu'elles sont considérablement altérées par la plupart des maladies pulmonaires comme le cancer, l'emphysème, l'asthme ou la fibrose interstitielle. Toutefois, l’auscultation et l’exploration tactile couramment utilisées ne peuvent pas localement les sonder in vivo. Dans ce travail de thèse, une nouvelle modalité a été développée pour cartographier les propriétés viscoélastiques du parenchyme pulmonaire afin de détecter, quantifier et classer les maladies qui les modifient. Cette nouvelle méthode d'imagerie, l’élastographie par résonance magnétique de l'hélium-3 hyperpolarisé, bénéficie de l'innocuité et de la sensibilité de la technique ainsi que de l'importance du signal d'hélium-3 hyperpolarisé dans les poumons.Tout d'abord, la technique a été validée sur des fantômes de poumons préservés de cochon. D'une part, les hypothèses de confinement du gaz et de l'indépendance à la composition du gaz qui sous-tendent l'élastographie IRM quantitative de l'hélium-3 ont été confirmées. D'autre part, la sensibilité de la technique a été éprouvée par rapport à l'inflation des poumons et à leur dépendance à la gravité. Puis, un mode d'excitation original a été développé et les protocoles d'acquisition IRM ont été optimisés pour réaliser l'élastographie IRM de l'hélium-3 in vivo. Les premières mesures de propagation d'ondes de cisaillement ont été obtenues à la fois dans des poumons de rat et d'humain. Les modules d'élasticité de cisaillement obtenus s'accordent assez bien avec les valeurs de rigidité obtenues ex vivo par les techniques alternatives. Ce travail ouvre une voie unique d'exploration in vivo de la physiopathologie pulmonaire. / According to the American Lung Association, for the last few years, lung diseases have become the third most common cause of death worldwide after cardiovascular disease and tumors, and it is expected to rise up the ranking position in the next ten years. Lung diseases such as Chronic Obstructive Pulmonary Disease and interstitial fibrosis affect millions of people worldwide, killing thousands of them every year while new cases are reported. Today, there is no early diagnosis of these pulmonary diseases. They effectively manifest by a modification of the viscoelastic properties of the lung parenchyma which cannot be detected by usual techniques that are applied to other organs. X-ray computer tomography and surgical lung biopsy can state the disease. However, it is not yet possible to predict its progression, to determine the optimal length of the therapy, or to explore the administration of other agents potentially less toxic than those used nowadays. Causes and mechanisms of the disease, associated genetic factors are not determined yet. The social and medical issues are huge. The viscoelastic properties of lung tissue play a key role in the basic function of the organ. They could be very sensitive pulmonary biomarkers as they depend on the tissue structure, the biological conditions, and they are dramatically altered by most lung diseases like cancer, emphysema, asthma, or interstitial fibrosis. However, current auscultation and tactual explorations fail to regionally probe them in vivo.In this PhD work, a new modality was developed to regionally measure the viscoelastic properties of the lung parenchyma in order to detect, quantify, and classify diseases that modify them. This new imaging approach, hyperpolarized helium-3 Magnetic Resonance Elastography (MRE), benefit from the innocuity and the sensitivity of the technique as well as from the huge hyperpolarized helium-3 signal in the lung. First, the technique was validated on preserved pig lung phantoms. On the one hand, the assumptions of gas confinement and gas content independence that support quantitative helium-3 MRE were assessed. On the other hand, the sensitivity of the technique was challenged with respect to lung inflation and gravity dependence. Second, original means of mechanical excitation were developed and MR acquisition protocols were optimized to perform helium-3 MRE in vivo. First measurements of shear wave propagation were achieved in both rat and human lungs. Resulting shear elasticity agrees fairly well with stiffness values found ex vivo by alternative measurement techniques. This work opens up promising insights into lung pathophysiology in vivo.
4

Evaluation de l’interaction fluide-structure dans les Voies Aériennes Supérieures par Imagerie par Résonance Magnétique / Evaluation of the upper airway fluid/structure coupling using magnetic resonance imaging during a breath cycle

Hagot, Pascal 24 February 2015 (has links)
Le Syndrome d’Apnée Obstructive du Sommeil affecte 4 à 6 % de la population en France soit près de 3 millions de personnes. Toutefois, les techniques de diagnostic usuelles ne permettent pas de déterminer de façon précise les sites d’occlusion ni de décrire les interactions fluide-paroi qui jouent un rôle important dans les processus de fermeture des voies aériennes supérieures. Au cours de ce travail, un ensemble d’outil a été mis en œuvre pour explorer les mécanismes sous-jacents conduisant à une apnée obstructive. La détermination géométrique et la caractérisation mécanique des voies aériennes supérieures, d’une part, la mesure des écoulements dans ces dernières, d’autre part, ont été réalisées par imagerie par résonance magnétique de l’hydrogène, pour les tissus, de l’hélium-3 et du fluor-19 pour les gaz. Les données obtenues ont été exploitées tout d’abord dans un modèle numérique statique pour estimer les lois d’état locales et caractériser la compliance des voies aériennes supérieures, puis, dans un modèle monodimensionnel, prenant en compte l’interaction fluide-structure et la limitation de débit au cours de l’inspiration, pour localiser les sites potentiellement responsables d’un éventuel collapsus. Par ailleurs, les écoulements de gaz d’hélium-3 et d’hexafluorure de soufre ont été simulés afin de déterminer le potentiel de ces deux modalités d’imagerie de gaz pour l’étude des obstructions des voies aériennes. La faisabilité d’une imagerie statique et dynamique par résonance magnétique du fluor a été démontrée. Avec une densité du gaz traceur bien plus importante, cette dernière technique présente une plus grande sensibilité à l’obstruction. Cette thèse ouvre ainsi une nouvelle voie de diagnostic et de guide thérapeutique personnalisé pour ce syndrome. / Obstructive Sleep Apnea (OSA) is a common disorder occurring in almost 3 million French people. However, current diagnosis methods are not sufficient to precisely define obstructing sites and doesn't take into account the fluid structure coupling which plays an important role during upper airway closing. During this thesis, we developed a series of tools exploring upper airway closing process. On the one hand, a screening tool of the structure and the mechanical properties of the upper airway, and on the other hand, a screening tool exploring with dynamic images of inert gases flow into the upper airway, were obtained using conventional hydrogen MRI coupled to magnetic resonance elastography (MRE) and helium-3 or fluor-19 gases MRI, respectively. Geometric and biomechanical data obtained using MRI/MRE are injected into a numerical model given the compliance and the state law of upper airway. Contributions of anatomical restriction on airway collapse are also investigated using a multi-compartmental two-dimensional fluid structure interaction model during a breath inspiration to predicted airway mechanical changes and collapse pressures. Furthermore, helium 3 and sulfur hexafluoride flow was modeled at steady state using commercial finite volume software to evaluate potential feasibility to image upper airway collapsibility during OSA. First dynamic MR imaging using sulfur hexafluoride (SF6) was obtained showing the feasibility of this technique. Using SF6, 6 times denser than air, shows a higher sensibility to upper airway obstruction. This thesis opens a new imaging modality to probe and to diagnose upper airway obstruction.
5

Magnetic Resonance of Hyperpolarised Helium-3 at Low Magnetic Fields

Safiullin, Kayum 27 September 2011 (has links) (PDF)
Dans ce travail nous avons étudié le problème du rapport signal à bruit (RSB) en IRM à très bas champ magnétique et exploré des applications potentielles en utilisant du gaz 3He hyperpolarisé. Nous avons comparé deux méthodes d'élargissement de bande passante sans perte de RSB : une contre-réaction et un couplage inductif de la détection. Nous avons mis en œuvre la contre-réaction, plus appropriée à très bas champ. Des mesures d'atténuation par diffusion dans un gaz d'3He en géométrie cylindrique ont été faites par échos multiples de spin ou de gradient dans une large gamme de conditions correspondant à la diffusion dans les voies aériennes des poumons. Un bas champ permet d'utiliser des faibles gradients sur des durées longues, sans influence de la susceptibilité des matériaux. Nos mesures fournissent un ensemble de données destiné à une comparaison directe avec des modèles théoriques et d'autres résultats publiés. Une nouvelle séquence (Slow Low Angle Shot, SLASH) est proposée pour l'imagerie de gaz à bas champ. Des séries d'images à 2D dans des fantômes montrent qu'elle offre une résolution d'image et un RSB meilleurs que pour une séquence FLASH. Par ailleurs, des cartes de diffusion apparente dans des poumons fixés de petit animal ont été obtenues à partir d'images 2D et 3D. Les résultats sont compatibles avec ceux des mesures globales de diffusion par échos de spin dans ces mêmes poumons, et sont similaires aux résultats in vivo publiés. Ces poumons fixés sont donc un fantôme commode et pertinent pour des études méthodologiques. Les mesures de diffusion en bas champ, insensibles aux effets de susceptibilité, ont été faites sur une large gamme de temps de diffusion.

Page generated in 0.0478 seconds