• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 7
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo de propriedades mecânicas de três resinas odontológicas comerciais fotopolimerizadas por LED e luz halógena

Macalós, Marta Ferreira January 2010 (has links)
Made available in DSpace on 2013-08-07T18:54:15Z (GMT). No. of bitstreams: 1 000423535-Texto+Completo-0.pdf: 597066 bytes, checksum: ce81a6cb6a7764590654a4d5a48d3e79 (MD5) Previous issue date: 2010 / This study aimed to examine the influence of time and intensity of energy, two types of light curing, LED and halogen light, the healing of three dental composite resins with different organic phases, Rok manufacturer of SDI, the organic phase UDMA, Filtek Z250, 3M ESPE, the organic phase Bis-GMA, UDMA, Bis-Ema, TEGDMA, and Ultradent Amelogem Plus, with the organic phase Bis-GMA and TEGDMA. Tests of tensile strength and diametral compressive strength and subsequently determining the modulus of elasticity of these resins. To test diametral tensile strength were prepared specimens with 6 mm in diameter and 3 mm thick for testing compressive strength, specimens with 3 mm in diameter and 6 mm thick. The resins were inserted in the headquarters in increments of 2 mm each and light cured by halogen light (3M Dental Products, Irvine, USA, 450 mW/cm for 18 and 36 s for 2the energy density of 8 and 16 J/cm2, respectively) and LED (High Powered Led Cordless - SDI LTD - Australia, with light intensity of 1200 mW/cm for 7 and 14 s for 2the energy density of 8 and 16 J/cm2). The samples were stored for 14 days at room temperature and distilled water, after this period the samples were tested in a universal testing machine EMIC DL - 2000, with the loading speed of 1 mm/min until the sample fractured. The results were tested using ANOVA and Tukey test with a confidence level of 95%. There was no statistically significant differences between groups of resin when analyzed in relation to the energy density for all items surveyed, compared to light curing units were statistically significant differences in modulus, and the halogen light showed better outcomes in relation to the LED (p=0,0166). With respect to the organic resins were superior in mechanical properties of those containing the UDMA monomer composition. Conclusion: The LED curing device presents itself as a viable alternative for use in dental practices and the implementation of the energy density of 8 J/cm, subject to the mechanical properties 2of the resins studied. / O presente estudo teve por objetivo estudar a influência do tempo e a intensidade de energia, de dois tipos de luz para fotopolimerização, LED e luz halógena, na cura de três resinas odontológicas compostas comerciais com diferentes fases orgânicas, Rok da fabricante SDI, fase orgânica UDMA; Filtek Z250, 3M ESPE, fase orgânica Bis-GMA, UDMA, Bis-EMA, TEGDMA; e Amelogem Plus da Ultradent, com fase orgânica Bis-GMA e TEGDMA. Foram realizados ensaios de resistência à tração diametral e resistência à compressão e posteriormente a determinação do módulo de elasticidade dessas resinas. Para o teste de resistência à tração diametral foram confeccionados corpos de prova com 6 mm de diâmetro e 3 mm de espessura e para o ensaio de resistência à compressão, corpos de prova com 3 mm de diâmetro e 6 mm de espessura. As resinas foram inseridas nas matrizes em incrementos de 2 mm cada e fotopolimerizadas por lâmpada halógena (3M Dental Products, Irvine, USA, com 450 mW/cm2 por 18 e 36 s para obter densidade de energia de 8 e 16 J/cm2, respectivamente) e por LED (High Powered Led Cordless – SDI LTD – Austrália, com intensidade de luz de 1200 mW/cm2 por 7 e 14 s para obter a densidade de energia de 8 e 16 J/cm2). As amostras foram armazenadas por 14 dias, em temperatura ambiente e água destilada, após esse período as amostras foram ensaiadas em uma máquina de ensaio universal EMIC DL – 2000, com velocidade de carregamento de 1 mm/min até que a amostra sofresse fratura. Os dados obtidos foram submetidos aos testes de variância ANOVA e Tukey com nível de confiança de 95%. Não houve diferenças estatisticamente significativa entre os grupos das resinas quando analisadas em relação à densidade de energia para todos os itens pesquisados (p<0,05).Em relação aos aparelhos fotopolimerizadores houve diferenças estatisticamente significativa para módulo de elasticidade, sendo que a luz halógena apresentou resultados superiores em relação ao LED (p=0,0166). Quanto à fase orgânica das resinas, apresentaram superioridade nas propriedades mecânicas àquelas que contêm o monômero UDMA em sua composição. Conclusão: O aparelho de fotopolimerização LED apresenta-se como uma alternativa viável para ser utilizado em consultórios dentários, bem como a aplicação da densidade de energia de 8 J/cm2, sem prejuízo das propriedades mecânicas das resinas estudadas.
2

Efeito biológico de uma fonte de luz halógena e de um LED na sobrevivência de culturas de Escherichia coli / A biocompatibility study of two light curing unit (LED and halogen light) upon the survival of Escherichia coli strains

Nathália Chacur Juliboni 17 December 2007 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A diversificação das fontes de luz empregadas para fotopolimerização de compósitos e o seu extenso uso nas diversas aplicações odontológicas, torna necessária a investigação da biocompatibilidade das mesmas. A conseqüente exposição dos tecidos durante estes procedimentos, sugere fortemente que mais investigações sobre os efeitos biológicos da luz com comprimentos de onda correspondentes ao da luz azul são necessárias. O efeito positivo provocado pela evolução dos aparelhos fotopolimerizadores desviou a atenção das possíveis alterações fototóxicas sobre o profissional e o paciente. Além disso, o aumento da temperatura causado por estes aparelhos fotopolimerizadores de maiores densidades de potência pode ser prejudicial ao tecido pulpar. Da mesma maneira, a presença de um corante no meio bucal e sua conseqüente exposição à luz azul poderia levar à formação de radicais livres, o que em situações de estresse oxidativo, poderia causar danos aos tecidos adjacentes. Este fenônemo é denominado Ação Fotodinâmica. O objetivo deste estudo foi avaliar em cepas de Escherichia coli (E. coli): (i) o potencial citotóxico de duas fontes de ativação utilizadas em procedimentos odontológicos durante 40 e 80 s de exposição; (ii) o efeito biológico do enxaguatório bucal da marca Plax Classic, contendo corante vermelho; (iii) o efeito biológico da associação das fontes de luz ao enxaguatório bucal da marca Plax Classic, contendo corante vermelho (ação fotodinâmica), durante 40 e 80 s de exposição; (iv) medir a emissão de calor gerada pelas fontes de luz. Foram utilizadas suspensões bacterianas de E.coli AB1157 (proficiente em mecanismos de reparo de lesões no DNA) e de E. coli BW9091 (deficiente no gene xthA-, envolvido no reparo por excisão de bases), irradiadas por um aparelho de luz halógena e um LED, que apresentam comprimentos de onda correspondentes ao da luz azul e densidades de potência de 430 mW/cm2 e 1669 mW/cm2, respectivamente. As medições da potência foram realizadas através de um lediômetro, para o LED, o Hilux LEDMAX, e um radiômetro acoplado ao próprio aparelho de luz halógena, Optilux 501. A partir dos resultados deste estudo, pôde-se constatar que: (i) as fontes de luz nas densidades de potência utilizadas e nos tempos de exposição realizados, não foram capazes de alterar a sobrevivência celular; (ii) o enxaguatório bucal isoladamente reduziu a sobrevivência das cepas de E. coli BW9091 e não causou efeito nas cepas de E. coli AB1157; (iii) quando o enxaguatório bucal foi associado às fontes de luz observamos que não houve diminuição da sobrevivência para as duas cepas bacterianas nos dois períodos de exposição, porém, na cepa mutante, BW9091, houve uma proteção contra o efeito citotóxico do enxaguatório bucal tanto em 40 quanto em 80 s para as duas fontes de luz; (iv) o aumento da temperatura das duas fontes de luz durante a fotoativação não foi capaz de reduzir a sobrevivência das cepas bacterianas. As fontes de luz utilizadas neste trabalho não apresentaram letalidade às cepas de E. coli. O enxaguatório bucal apresentou efeito biológico para a cultura de E. coli BW9091, possivelmente pela sua natureza antimicrobiana. A associação dos agentes físico e químico neste estudo não pareceu causar um estresse oxidativo nas células a ponto de reduzir a sobrevivência das culturas bacterianas, contrariamente, pareceu ativar mecanismos de proteção celular na cepa de E. coli BW9091 e mantê-la mais resistente à ação antimicrobiana do enxaguatório bucal. A variação da temperatura, apesar de elevada, parece ter sido dissipada pelo meio aquoso que continha a cultura bacteriana. / The diversity of light curing units (LCUs), its large use on variety dental applications, and its function as an activator of dental composites polymerization make necessary a study of its biocompatibility. The consequent exposure of tissues during photo activation, strongly suggests that more investigations about the biological effects of blue light are needed. The positive effect promoted by the LCUs evolution biased the attention of possible phototoxic effects on professionals and patients. In addition, the temperature rise caused by these LCUs with higher power densities may be harmful to the pulp tissue. On the same way, the presence of a photosensitizer upon oral environment and its consequent exposure to blue light could lead the formation of free radicals, in which oxidative stress outcome could damage the adjacent tissues. This phenomenon is called Photodynamic Action. The aim of this study was to evaluate in Escherichia coli (E. coli) strains: (i) the cytotoxic effect of two LCUs used in dental procedures during 40 and 80 seconds of irradiation times; (ii) the biological effect of a mouth rinse with a red photosensitizer, Plax Classic; (iii) the biological effect of the association of the LCUs to a mouth rinse, with a red photosensitizer, Plax Classic, during 40 and 80 seconds of irradiation times; (iv) measurement of the LCUs thermal emission. Suspensions of E. coli AB1157 (proficient in all DNA repair mechanisms) and E. coli BW9091 (gene xthA- deficient, related to DNA damage repair), were irradiated by a halogen light and a LED (light emitting diode), that presents intervals of wavelength correspondents with blue light and power densities of 430 mW/cm2 and 1669 mW/cm2, respectively. The power density for the LED LCU was measured on a Hilux LEDMAX power meter, and for the halogen LCU, on the Optilux 501 power meter. The results indicated that: (i) the LCUs used with these power densities and these irradiation times, were not capable in altering the cellular survival rate; (ii) the mouth rinse itself reduced the survival rate of E. coli strain BW9091 and did not caused effect in E. coli strain AB1157; (iii) when the mouth rinse was associated to the LCUs, we observed that there was no reduction of the survival rate to both E. coli strains in both irradiation times; however, in the mutant strain, BW9091, a protection against the citotoxic effect of the mouth rinse was observed in 40 and 80 seconds of irradiation times to both LCUs; (iv) the temperature rise of both LCUs during photo activation, despite being elevated, was not capable in reducing the bacterial strains survival rate. The LCUs used in this study did not present lethal effect to the E. coli strains. The mouth rinse presented a biological effect to the E. coli strain BW9091, possibly because its antimicrobial nature. Although the association of the physical and chemical agents did not seem to cause an oxidative stress that could reduce the bacterial survival rate of E. coli strains, it seemed to activate mechanisms of cellular protection in E. coli BW9091 that kept them more resistants to the antimicrobial nature of the chemical agent. The temperature rise seemed to be dissipated by the aquous solution that contained the bacterial culture.
3

Efeito biológico de uma fonte de luz halógena e de um LED na sobrevivência de culturas de Escherichia coli / A biocompatibility study of two light curing unit (LED and halogen light) upon the survival of Escherichia coli strains

Nathália Chacur Juliboni 17 December 2007 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A diversificação das fontes de luz empregadas para fotopolimerização de compósitos e o seu extenso uso nas diversas aplicações odontológicas, torna necessária a investigação da biocompatibilidade das mesmas. A conseqüente exposição dos tecidos durante estes procedimentos, sugere fortemente que mais investigações sobre os efeitos biológicos da luz com comprimentos de onda correspondentes ao da luz azul são necessárias. O efeito positivo provocado pela evolução dos aparelhos fotopolimerizadores desviou a atenção das possíveis alterações fototóxicas sobre o profissional e o paciente. Além disso, o aumento da temperatura causado por estes aparelhos fotopolimerizadores de maiores densidades de potência pode ser prejudicial ao tecido pulpar. Da mesma maneira, a presença de um corante no meio bucal e sua conseqüente exposição à luz azul poderia levar à formação de radicais livres, o que em situações de estresse oxidativo, poderia causar danos aos tecidos adjacentes. Este fenônemo é denominado Ação Fotodinâmica. O objetivo deste estudo foi avaliar em cepas de Escherichia coli (E. coli): (i) o potencial citotóxico de duas fontes de ativação utilizadas em procedimentos odontológicos durante 40 e 80 s de exposição; (ii) o efeito biológico do enxaguatório bucal da marca Plax Classic, contendo corante vermelho; (iii) o efeito biológico da associação das fontes de luz ao enxaguatório bucal da marca Plax Classic, contendo corante vermelho (ação fotodinâmica), durante 40 e 80 s de exposição; (iv) medir a emissão de calor gerada pelas fontes de luz. Foram utilizadas suspensões bacterianas de E.coli AB1157 (proficiente em mecanismos de reparo de lesões no DNA) e de E. coli BW9091 (deficiente no gene xthA-, envolvido no reparo por excisão de bases), irradiadas por um aparelho de luz halógena e um LED, que apresentam comprimentos de onda correspondentes ao da luz azul e densidades de potência de 430 mW/cm2 e 1669 mW/cm2, respectivamente. As medições da potência foram realizadas através de um lediômetro, para o LED, o Hilux LEDMAX, e um radiômetro acoplado ao próprio aparelho de luz halógena, Optilux 501. A partir dos resultados deste estudo, pôde-se constatar que: (i) as fontes de luz nas densidades de potência utilizadas e nos tempos de exposição realizados, não foram capazes de alterar a sobrevivência celular; (ii) o enxaguatório bucal isoladamente reduziu a sobrevivência das cepas de E. coli BW9091 e não causou efeito nas cepas de E. coli AB1157; (iii) quando o enxaguatório bucal foi associado às fontes de luz observamos que não houve diminuição da sobrevivência para as duas cepas bacterianas nos dois períodos de exposição, porém, na cepa mutante, BW9091, houve uma proteção contra o efeito citotóxico do enxaguatório bucal tanto em 40 quanto em 80 s para as duas fontes de luz; (iv) o aumento da temperatura das duas fontes de luz durante a fotoativação não foi capaz de reduzir a sobrevivência das cepas bacterianas. As fontes de luz utilizadas neste trabalho não apresentaram letalidade às cepas de E. coli. O enxaguatório bucal apresentou efeito biológico para a cultura de E. coli BW9091, possivelmente pela sua natureza antimicrobiana. A associação dos agentes físico e químico neste estudo não pareceu causar um estresse oxidativo nas células a ponto de reduzir a sobrevivência das culturas bacterianas, contrariamente, pareceu ativar mecanismos de proteção celular na cepa de E. coli BW9091 e mantê-la mais resistente à ação antimicrobiana do enxaguatório bucal. A variação da temperatura, apesar de elevada, parece ter sido dissipada pelo meio aquoso que continha a cultura bacteriana. / The diversity of light curing units (LCUs), its large use on variety dental applications, and its function as an activator of dental composites polymerization make necessary a study of its biocompatibility. The consequent exposure of tissues during photo activation, strongly suggests that more investigations about the biological effects of blue light are needed. The positive effect promoted by the LCUs evolution biased the attention of possible phototoxic effects on professionals and patients. In addition, the temperature rise caused by these LCUs with higher power densities may be harmful to the pulp tissue. On the same way, the presence of a photosensitizer upon oral environment and its consequent exposure to blue light could lead the formation of free radicals, in which oxidative stress outcome could damage the adjacent tissues. This phenomenon is called Photodynamic Action. The aim of this study was to evaluate in Escherichia coli (E. coli) strains: (i) the cytotoxic effect of two LCUs used in dental procedures during 40 and 80 seconds of irradiation times; (ii) the biological effect of a mouth rinse with a red photosensitizer, Plax Classic; (iii) the biological effect of the association of the LCUs to a mouth rinse, with a red photosensitizer, Plax Classic, during 40 and 80 seconds of irradiation times; (iv) measurement of the LCUs thermal emission. Suspensions of E. coli AB1157 (proficient in all DNA repair mechanisms) and E. coli BW9091 (gene xthA- deficient, related to DNA damage repair), were irradiated by a halogen light and a LED (light emitting diode), that presents intervals of wavelength correspondents with blue light and power densities of 430 mW/cm2 and 1669 mW/cm2, respectively. The power density for the LED LCU was measured on a Hilux LEDMAX power meter, and for the halogen LCU, on the Optilux 501 power meter. The results indicated that: (i) the LCUs used with these power densities and these irradiation times, were not capable in altering the cellular survival rate; (ii) the mouth rinse itself reduced the survival rate of E. coli strain BW9091 and did not caused effect in E. coli strain AB1157; (iii) when the mouth rinse was associated to the LCUs, we observed that there was no reduction of the survival rate to both E. coli strains in both irradiation times; however, in the mutant strain, BW9091, a protection against the citotoxic effect of the mouth rinse was observed in 40 and 80 seconds of irradiation times to both LCUs; (iv) the temperature rise of both LCUs during photo activation, despite being elevated, was not capable in reducing the bacterial strains survival rate. The LCUs used in this study did not present lethal effect to the E. coli strains. The mouth rinse presented a biological effect to the E. coli strain BW9091, possibly because its antimicrobial nature. Although the association of the physical and chemical agents did not seem to cause an oxidative stress that could reduce the bacterial survival rate of E. coli strains, it seemed to activate mechanisms of cellular protection in E. coli BW9091 that kept them more resistants to the antimicrobial nature of the chemical agent. The temperature rise seemed to be dissipated by the aquous solution that contained the bacterial culture.
4

Estudo, in vitro, da influência da técnica e do aparelho de fotopolimerização na resistência de união de pinos intra-radiculares / In vitro study of influence of technique and light curing unit in retention force of fiber post system

Nagase, Denis Yudi 04 March 2010 (has links)
Objetivo: Este estudo se propõe a verificar a influencia do tipo de luz fotopolimerizadora na força de retenção de pinos intra-radiculares, tanto na técnica direta como na direta indireta. Métodos: 40 raízes de dentes bovinos com comprimento de 12 mm foram tratadas endodonticamente e divididas aleatoriamente em 4 grupos de acordo com a técnica de obtenção dos pinos e luz fotopolimerizadora (n=10): grupo 1 (técnica direta associada à lâmpada halogena); grupo 2 (técnica direta ao LED); grupo 3 (técnica direta-indireta associada à lampada halógena); e grupo 4 (técnica direta-indireta associada ao LED). A força de retenção foi determinada através do teste de tração usando Universal Testing Machine (Instron). Todos os dados foram analisados usando one-way analysis of variance (ANOVA) com a significância de p<0.05 e complementadas com teste de Tukey. Após o teste, as interfaces adesivas onde ocorreram as falhas foram examinadas e classificadas. Resultado: Os grupos 3 (246,05N ± 29,51) e 4 (241,60N ± 28,95) não apresentaram força de retenção estatisticamente diferente mas foram maiores que os grupos 1 (142,30N ± 25,60) e 2 (178,56N ± 25,67). A maior parte das fraturas ocorreu na interface dentina/resina. Conclusão: Com base nos resultados obtidos, concluímos que o método direto-indireto proporcionou a melhor retenção dos pinos de fibra de vidro. / Objectives: The purpose of this study is to verify the influence of light curing type on retention force of direct technique and direct-indirect technique. Methods: Fourth bovine single root teeth with 12mm of length were used in this study. The roots were endodontically treated and randomly divided in four groups according to the light curing unit and technique used: group 1(direct technique, halogen lamp), group 2(direct technique, LED), group 3(direct-indirect technique, halogen lamp), group 4(direct-indirect technique, lamp). The retention force was determined sing a Universal Testing Machine (Instron). All data were analyzed using one-way analysis of variance (ANOVA) and Tukey test. After the test, the failure was examined and classified according to the fracture place: post/ resin; resin/dentin; mix. Results: Group 3 (246,05N ± 29,51) and 4(241,60N ± 28,95)4 (95,18N) did not show statistically difference but presented higher retention force than group 1 (142,30N ± 25,60) and 2 (178,56N ± 25,67). Most of fracture occurred in interface between dentin/resin. Conclusion: Based on the obtained results, it was concluded that adhesive cementation technique influenced in the retention of glass fiber post.
5

\"Estudo do efeito da distância da ponta de aparelhos fotoativadores na microdureza e no grau de conversão da resina composta usando luz halógena, laser de argônio e LED\" / Study of the effect of light curing tip distance on microhardness and on degree of conversion of a composite resin using halogen light, argon laser and LED.

Rode, Kátia Martins 16 February 2007 (has links)
O objetivo desse estudo foi avaliar o efeito da distância da ponta fotoativadora na profundidade de polimerização da resina composta por meio de testes de microdureza Vickers e da análise do grau de conversão pelo método FT-Raman. O aparelho de luz halógena (500 mW/cm2) e o LED (900 mW/cm2) foram utilizados na sua intensidade convencional. O laser de argônio, na potência de 250 mW. Os tempos de fotoativação foram de 40 segundos para a luz halógena, 20 segundos para o LED e 20 e 30 segundos para o laser. E as distâncias da ponta fotoativadora foi padronizada com anéis de 3, 6 e 9 mm de altura. A resina composta micro-híbrida foi inserida em porção única, em matrizes de polipropileno pretas com as espessuras de 1 a 4 mm. Os corpos-de-prova foram armazenados por uma semana a seco, a 37ºC em recipientes protegidos da luz. Os dados da microdureza e do grau de conversão foram analisados separadamente por meio da análise de variância e teste de Tukey, com nível de significância de 5% e depois correlacionados pelo teste de correlação de Pearson. Os resultados obtidos permitiram concluir que: o aumento da distância da fonte de luz promoveu uma diminuição nos valores de microdureza e no grau de conversão para todos os tipos de fontes de luz estudados e o mesmo ocorreu com o aumento da espessura de resina composta diminuindo também os valores de microdureza e grau de conversão. Houve uma alta correlação entre a análise PDM (porcentagem de dureza máxima) e a análise do grau de conversão e entre o teste de microdureza e a análise do grau de conversão. As fontes de fotoativação estudadas promoveram grau de conversão e microdureza correspondentes entre si, desde que a espessura da resina fosse de 1 mm de espessura e a que a fonte estivesse a uma distância máxima de 3 mm. / This study evaluated the influence of curing tip distance on cure depth of a composite resin, measuring the Vickers microhardness and determining the degree of conversion, using FT-Raman spectroscopy. The halogen light (500 mW/cm2) and the LED (900 mW/cm2) were used with conventional intensity of power and the argon laser with 250mW. The exposure time was 40 seconds to halogen light, 20 seconds to LED and 20 and 30 seconds to Argon laser. And the curing tip distances used (0, 3, 6 e 9 mm) were controlled by metals rings. The composite was placed in one increment, in a black polipropilen matrix with thickness of the 1 to 4 mm. The specimens were stored for one week in dry stove, for 37ºC in containers protect from the light. The values of microhardness and degree of coonversion were analyzed separately by ANOVA (Analysis of variance) and Tukey test, with significance level for 5%. Then, the correlation was analyzed by Pearson test. The results obtained conclude that: the increased of tip distance produced a decreased in microhardness and degree of conversion values; the microhardness and degree conversion values decreased as the thickness increased; it showed a higher correlation between the qualities of polymerization and the degree of conversion and between the microhardness test and the degree of conversion. The present study suggests that the units of polymerization studied produced microhardness and degree of conversion values that corresponded to each other, only with 1mm of thickness and using a tip distance of 3 mm, at most.
6

Influência da fonte de luz fotoativadora nas propriedades ópticas de resína composta, em função da cor, espessura e tempo de armazenamento

Queiroz, Renato Souza [UNESP] 10 August 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-08-10Bitstream added on 2014-06-13T19:40:56Z : No. of bitstreams: 1 queiroz_rs_dr_arafo.pdf: 679998 bytes, checksum: 47166f3c2a2f40adf0235d9237b0bd24 (MD5) / Esse estudo se propõe a avaliar as propriedades ópticas (Fluorescência e Absorbância) da resina composta fotoativada (4 SEASONS®) utilizando aparelho fotopolimerizador convencional (luz Halógena Ulttralux - DabiAtlant), e aparelho emissor de Diodo (Radii – SDI e Ultralume Led 5- Ultradent), em função da fonte de luz foto-ativadora, cor, espessura e tempo de armazenamento em saliva artificial. Foram confeccionadas 5 amostras (10,0x1,0 mm) para cada grupo experimental. Para a realização do teste de Absorbância foi utilizado aparelho espectrofotômetro de luz visível (Diode Array Spectrophotometer, HP – Serial Number: 8452-A). Para a obtenção dos valores de fluorescência emitida pelas amostras, foi utilizado espectrofotômetro (SPEX TRIAX FLUOROLOG 3, Jobin Yvon – Serial Number: 0135B-3-99). Os resultados foram julgados estatisticamente conforme a interação entre os fatores de avaliação nos distintos trabalhos. Pode-se concluir que a fonte de luz fotoativadora influenciou apenas a emissão fluorescente da resina de cor TC, não tendo efeito negativo na absorbância; o aumento na espessura da amostra acarretou uma diminuição na emissão fluorescente e na absorbância de todas as cores da resina, independente da fonte de luz; e as diferentes cores da resina exibiram diferentes emissões fluorescentes e absorbância... / The arm of this study is to evaluate optical properties (fluorescence and Absorbance) of a composite resin (4 SEASONS®) using light curing units (LCUs)-(QTH - Ulttralux – DabiAtlant and LEDs Radii – SDI and Ultralume Led 5- Ultradent) in function of LCUs, shade, thickness and storage times. 5 samples were prepared for each experimental group. To perform the Absorbance test, was used of UV-Vis spectrophotometer (Diode Array Spectrophotometer, HP – Serial Number: 8452-A). To obtain the fluorescence emission by samples, we used a spectrophotometer (SPEX TRIAX FLUOROLOG 3, Jobin Yvon – Serial Number: 0135B-3-99). The results were deemed statistically as the interaction between the evaluation factors in the different works. It can be concluded that the LCUs only influenced the fluorescent emission of resin color TC, having no negative effect on the absorbance; the increase in thickness of the sample decrease the fluorescent emission and absorbance for colors of the resin, independent of the LCUs; different colors of resin exhibited different fluorescent emission and absorbance.
7

\"Estudo do efeito da distância da ponta de aparelhos fotoativadores na microdureza e no grau de conversão da resina composta usando luz halógena, laser de argônio e LED\" / Study of the effect of light curing tip distance on microhardness and on degree of conversion of a composite resin using halogen light, argon laser and LED.

Kátia Martins Rode 16 February 2007 (has links)
O objetivo desse estudo foi avaliar o efeito da distância da ponta fotoativadora na profundidade de polimerização da resina composta por meio de testes de microdureza Vickers e da análise do grau de conversão pelo método FT-Raman. O aparelho de luz halógena (500 mW/cm2) e o LED (900 mW/cm2) foram utilizados na sua intensidade convencional. O laser de argônio, na potência de 250 mW. Os tempos de fotoativação foram de 40 segundos para a luz halógena, 20 segundos para o LED e 20 e 30 segundos para o laser. E as distâncias da ponta fotoativadora foi padronizada com anéis de 3, 6 e 9 mm de altura. A resina composta micro-híbrida foi inserida em porção única, em matrizes de polipropileno pretas com as espessuras de 1 a 4 mm. Os corpos-de-prova foram armazenados por uma semana a seco, a 37ºC em recipientes protegidos da luz. Os dados da microdureza e do grau de conversão foram analisados separadamente por meio da análise de variância e teste de Tukey, com nível de significância de 5% e depois correlacionados pelo teste de correlação de Pearson. Os resultados obtidos permitiram concluir que: o aumento da distância da fonte de luz promoveu uma diminuição nos valores de microdureza e no grau de conversão para todos os tipos de fontes de luz estudados e o mesmo ocorreu com o aumento da espessura de resina composta diminuindo também os valores de microdureza e grau de conversão. Houve uma alta correlação entre a análise PDM (porcentagem de dureza máxima) e a análise do grau de conversão e entre o teste de microdureza e a análise do grau de conversão. As fontes de fotoativação estudadas promoveram grau de conversão e microdureza correspondentes entre si, desde que a espessura da resina fosse de 1 mm de espessura e a que a fonte estivesse a uma distância máxima de 3 mm. / This study evaluated the influence of curing tip distance on cure depth of a composite resin, measuring the Vickers microhardness and determining the degree of conversion, using FT-Raman spectroscopy. The halogen light (500 mW/cm2) and the LED (900 mW/cm2) were used with conventional intensity of power and the argon laser with 250mW. The exposure time was 40 seconds to halogen light, 20 seconds to LED and 20 and 30 seconds to Argon laser. And the curing tip distances used (0, 3, 6 e 9 mm) were controlled by metals rings. The composite was placed in one increment, in a black polipropilen matrix with thickness of the 1 to 4 mm. The specimens were stored for one week in dry stove, for 37ºC in containers protect from the light. The values of microhardness and degree of coonversion were analyzed separately by ANOVA (Analysis of variance) and Tukey test, with significance level for 5%. Then, the correlation was analyzed by Pearson test. The results obtained conclude that: the increased of tip distance produced a decreased in microhardness and degree of conversion values; the microhardness and degree conversion values decreased as the thickness increased; it showed a higher correlation between the qualities of polymerization and the degree of conversion and between the microhardness test and the degree of conversion. The present study suggests that the units of polymerization studied produced microhardness and degree of conversion values that corresponded to each other, only with 1mm of thickness and using a tip distance of 3 mm, at most.
8

Estudo, in vitro, da influência da técnica e do aparelho de fotopolimerização na resistência de união de pinos intra-radiculares / In vitro study of influence of technique and light curing unit in retention force of fiber post system

Denis Yudi Nagase 04 March 2010 (has links)
Objetivo: Este estudo se propõe a verificar a influencia do tipo de luz fotopolimerizadora na força de retenção de pinos intra-radiculares, tanto na técnica direta como na direta indireta. Métodos: 40 raízes de dentes bovinos com comprimento de 12 mm foram tratadas endodonticamente e divididas aleatoriamente em 4 grupos de acordo com a técnica de obtenção dos pinos e luz fotopolimerizadora (n=10): grupo 1 (técnica direta associada à lâmpada halogena); grupo 2 (técnica direta ao LED); grupo 3 (técnica direta-indireta associada à lampada halógena); e grupo 4 (técnica direta-indireta associada ao LED). A força de retenção foi determinada através do teste de tração usando Universal Testing Machine (Instron). Todos os dados foram analisados usando one-way analysis of variance (ANOVA) com a significância de p<0.05 e complementadas com teste de Tukey. Após o teste, as interfaces adesivas onde ocorreram as falhas foram examinadas e classificadas. Resultado: Os grupos 3 (246,05N ± 29,51) e 4 (241,60N ± 28,95) não apresentaram força de retenção estatisticamente diferente mas foram maiores que os grupos 1 (142,30N ± 25,60) e 2 (178,56N ± 25,67). A maior parte das fraturas ocorreu na interface dentina/resina. Conclusão: Com base nos resultados obtidos, concluímos que o método direto-indireto proporcionou a melhor retenção dos pinos de fibra de vidro. / Objectives: The purpose of this study is to verify the influence of light curing type on retention force of direct technique and direct-indirect technique. Methods: Fourth bovine single root teeth with 12mm of length were used in this study. The roots were endodontically treated and randomly divided in four groups according to the light curing unit and technique used: group 1(direct technique, halogen lamp), group 2(direct technique, LED), group 3(direct-indirect technique, halogen lamp), group 4(direct-indirect technique, lamp). The retention force was determined sing a Universal Testing Machine (Instron). All data were analyzed using one-way analysis of variance (ANOVA) and Tukey test. After the test, the failure was examined and classified according to the fracture place: post/ resin; resin/dentin; mix. Results: Group 3 (246,05N ± 29,51) and 4(241,60N ± 28,95)4 (95,18N) did not show statistically difference but presented higher retention force than group 1 (142,30N ± 25,60) and 2 (178,56N ± 25,67). Most of fracture occurred in interface between dentin/resin. Conclusion: Based on the obtained results, it was concluded that adhesive cementation technique influenced in the retention of glass fiber post.

Page generated in 0.0807 seconds