• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A study of microho1low cathode discharge plasmas by laser absorption spectroscopy of excited helium atoms / 励起ヘリウム原子のレーザー吸収分光によるマイクロホローカソード放電プラズマの研究

Ueno, Keisuke 25 March 2019 (has links)
京都大学 / 0048 / 新制・課程博士 / 博士(工学) / 甲第21756号 / 工博第4573号 / 新制||工||1713(附属図書館) / 京都大学大学院工学研究科機械理工学専攻 / (主査)教授 蓮尾 昌裕, 教授 木村 健二, 教授 江利口 浩二 / 学位規則第4条第1項該当 / Doctor of Philosophy (Engineering) / Kyoto University / DFAM
2

Optical and Mass Spectrometric Studies of a Helium Dielectric-Barrier Atmospheric-Pressure Plasma Jet Used as an Ambient Desorption Ionization Source

Heywood, Matthew Spencer 06 March 2012 (has links) (PDF)
Recently there has been a surge in the field of mass spectrometry centered around the concept of rapid analysis of target analytes with minimal or no sample preparation. The target analyte undergoes desorption from its surface of origin and is subsequently ionized under ambient conditions. The technique is termed ambient desorption/ionization mass spectrometry (ADI-MS). Since the introduction of ADI-MS in 2004, there has been an explosion of research based around the development of novel ambient desorption/ionization (ADI) sources with the capability of desorbing and ionizing a variety of target analytes from various sampling surfaces. One type of ADI source uses the properties of an electrical discharge, typically a helium gas plasma, for desorption and ionization. For electrical-discharge-based sources, ionization is the result of an atmospheric pressure chemical ionization (APCI) process. The initiation of the APCI process it generally attributed to the Penning ionization of atmospheric nitrogen (N2) by highly energetic helium metastable species (Hem). In this work, I describe the direct imaging of the densities of helium metastable atoms in atmospheric pressure plasma jet (APPJ) of a helium-based dielectric-barrier discharge (DBD) using collisionally-assisted laser-induced fluorescence. Axial Hem distributions are compared to the emission of excited helium (He*) and nitrogen ion (N2+*) species in the plasma. A correlation is found between Hem densities and the performance of the ionization source in ADI-MS. Fluorescence images also show that Hem densities increase substantially when a glass slide is placed 10 mm from the discharge capillary in a geometry typical for desorption/ionization experiments. Advantage is taken of the time-varying nature of the plasma to produce axial profiles of temporally and spectrally resolved fluorescence images of Hem atoms and ground state nitrogen ions in the plasma jet. The axial distribution and similarities in the temporal behavior of the helium metastable and ground state nitrogen ion species give strong evidence that nitrogen ion species are created via Penning ionization by helium metastable atoms. Although axial distributions of He*,N2+*, and N2* emission support the fluorescence data, temporally-resolved emission measurements show that emission from key plasma species is almost entirely the result of excitation by a temporal energy wave. The effect that hydrogen (H2) has on the helium metastable atom densities is also presented. The addition of hydrogen to the discharge gas severely quenches the metastable state, leaving it virtually undetectable. The addition of 0.9% H2 to the helium in the source provides an order of magnitude increase in ADI-MS signal for target analytes despite the quenching of the Hem population.
3

Etude d’un micro-jet de plasma à pression atmosphérique / Study of a cold atmospheric pressure plasma micro jet

Douat, Claire 17 February 2014 (has links)
Ces dernières années un nouveau type de décharges hors équilibre thermodynamique, aptes à générer des micro jets de plasma se propageant en atmosphère libre, a suscité beaucoup d’intérêt dans la communauté scientifique. Ces micro jets, produits dans des structures type décharge à barrière diélectrique, ont des propriétés particulièrement intéressantes, tant sur le plan de la physique des plasmas que sur celui des applications, en particulier pour des applications biomédicales ou de traitement de surface.Dans ce travail de thèse il est démontré que ces jets de plasma correspondent à la propagation à grande vitesse d'un front d'ionisation sans déplacement de matière. Une caractérisation des propriétés des jets (vitesse et distance de propagation) a été effectuée en fonction de la tension appliquée, du débit, de la composition du gaz, et de la géométrie de la décharge. La distribution spatio-temporelle des espèces réactives produites par le jet a été mesurée, et en particulier celle de l'état métastable He (2³S) mesuré par absorption laser. Des densités comprises entre 1.10¹² et 5.10¹³ cm-³ ont été obtenues pour l’état He (2³S). Sa distribution est annulaire à la sortie de la structure de la décharge et se referme le long du jet. La densité maximale est obtenue à une distance correspondant à la moitié de la zone où les atomes métastables sont présents, ce qui est en contradiction avec les modèles actuels. De plus, afin de mieux comprendre la physique des jets de plasma, nous avons fait interagir deux jets placés l’un en face de l’autre. L'étude de la contre propagation de deux jets révèle qu’il existe une distance minimale d'approche laissant entre eux une zone exempte de plasma. Après l’extinction des deux plasmas, une seconde décharge s’amorce exactement dans cette zone. Une étude détaillée couplant diagnostics électrique, imagerie ultra-rapide et spectroscopie d'émission nous a permis de montrer que cette décharge secondaire est due à une inversion de polarité conduisant à la création transitoire d'un piège à électrons.Dans le but d'aborder l'étude des applications des jets de plasma au domaine biologique, nous avons également étudié la dégradation de l’ADN plasmidique par un jet de plasma. Nous avons mis en évidence que ce type de plasma induit majoritairement des cassures simples et doubles brins, alors que très peu d’oxydations de base ou de sites abasiques sont observés, ceci même avec l’ajout de quelques pourcents d’oxygène dans le gaz. / Micro plasma jets operating at atmospheric pressure in free atmosphere have recently attracted great attention because of their numerous advantages. In fact, micro plasma jets can be operated stably at atmospheric pressure and propagated over some centimeters in a free atmosphere. Moreover, these jets are non-thermal plasmas and create numerous reactive species. These properties allow to use this kind of plasma in many applications, such as surface treatment, decontamination, and plasma medicine.In this work it is shown that these micro plasma jets correspond to the fast propagation of an ionization front with no displacement of matter. A characterization of the plasma proprieties (e.g. distance and velocity of propagation) has been done as a function of the applied voltage, gas flow, gas composition and discharge geometry. The spatiotemporal distribution of the reactive species created by the plasma has been measured, with a special focus on the helium metastable atoms which have been measured by absorption laser spectroscopy. The helium metastable atom densities obtained are in the range of 1.10¹² to 5.10¹³ cm-³. Thanks to a very good spatiotemporal resolution, we have done a time-resolved full cartography of the plasma. This allowed us to show that the helium metastable atom distribution is annular near the nozzle and becomes circular as the plasma propagates. The maximum helium metastable atoms density has been measured at about half of the distance where the helium metastable atoms are present. This observation is in contradiction with results reported by numerical models. To gain further insight into the physical processes of the plasma, we have placed two micro plasma jets face to face. This study showed that both plasmas interact in such a way that they never come into contact, letting a space free of plasma between them. Moreover, we revealed that after the extinction of the plasmas, a second discharge is ignited in the previously free space. Fast imaging, spectroscopy diagnostics and electrical measurements showed that this second discharge is due to a polarity reversal, which creates an electron trap. Aiming the study of the application of micro plasma jets in the plasma medicine field, we have studied the degradation of plasmid DNA by our plasma jet. We observed that the plasma treatment leads mostly to single and double strands breaks, and to very little base oxidation and abasite site, even when oxygen is added into the gas mixture.
4

Etude de la production des espèces réactives de l’oxygène et de l’azote par décharge Plasma Gun à pression atmosphérique pour des applications biomédicales / Study of oxygen and nitrogen reactive species production in atmospheric pressure Plasma Gun discharge for biomedical applications

Darny, Thibault 27 June 2016 (has links)
En l’espace d’une dizaine d’années, les jets de plasma froid à pression atmosphérique ont su s’imposer comme un outil pertinent pour les applications biomédicales. La simplicité de conception et d’utilisation de ces dispositifs, combinée à leurs facultés de produire des espèces réactives (NO, OH, O …), ont significativement contribué au développement rapide du domaine. Beaucoup d’efforts ont été entrepris dans le développement de diagnostics quantitatifs, pour mesurer la production des espèces réactives dans la plume plasma d’un jet donné. Toutefois, la diversité des géométries de décharge, des sources d’alimentations électriques ou des conditions d’utilisation, rendent les comparaisons d’un jet à l’autre, difficiles. Cette thèse a porté sur l’étude du jet de plasma froid à pression atmosphérique développé au GREMI, le Plasma Gun (hélium, impulsion de tension microseconde). Nous avons étudié les mécanismes de décharge susceptibles de considérablement affecter la production d’espèces réactives, dans des conditions approchantes d’applications biomédicales. La thèse s’articule en trois chapitres principaux : l’étude de la modification de l’écoulement de l’hélium par plasma (par strioscopie) ; l’étude de la propagation du plasma dans le capillaire diélectrique (étude expérimentale et numérique de la dynamique de propagation rapide du plasma et de l’évolution du champ électrique en mélange hélium-azote) ; l’étude de l’interaction du plasma avec une cible conductrice (mesures dans le capillaire et dans la plume de l’évolution spatiale et temporelle de la concentration des métastables de l’hélium, corrélées à des mesures du champ électrique). Ce dernier point est en particulier représentatif de tout jet plasma en condition traitement biomédical in vivo et tend à faire une distinction fondamentale avec les mécanismes de décharge du jet plasma dit « libre », sans obstacle entravant la plume plasma. / Over the past ten years, the cold atmospheric pressure plasma jets (CAPPJ) became useful devices for biomedical applications. Their relatively simple design and use, combine with their ability to produce reactive species (NO, OH, O, …), led to a rapid research growth in this field. A lot of studies have been devoted to quantitative diagnostics development for the reactive species production measurements in the plasma plume. However, it is difficult to compare one jet with another because of the huge variety of discharge geometries, electric power supplies or operating conditions. This thesis deals with the study of the CAPPJ developed in GREMI, the Plasma Gun (helium feeded, microsecond voltage pulse). We have studied discharge mechanisms which strongly impact the reactive species production in near target biomedical application conditions. This study is divided in three parts : the study of helium flow modifications induced by the plasma (strioscopy visualization); the study of plasma propagation inside dielectric capillary (experimental and numerical study of fast plasma propagation dynamic and electric field evolution for helium-nitrogen mixtures); the study of conductive target-plasma interaction (space and time resolved measurements inside the capillary and the plasma plume of helium metastable production, correlated with electric field evolution). The conductive target contact concerns any in vivo biomedical treatments. CAPPJ in front of such a conductive target leads to fundamentally different discharge mechanisms compare to the free jet case.

Page generated in 0.0752 seconds