• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

In Vivo Tissue Diagnosis for Myocardial Infarction Using Optical Spectroscopy with Novel Spectral Interpretation Algorithms

Chen, Po-Ching 31 March 2011 (has links)
In recent decades, the rapid development of optical spectroscopy for tissue diagnosis has been indicative of its high clinical value. The goal of this research is to prove the feasibility of using diffuse reflectance spectroscopy and fluorescence spectroscopy to assess myocardial infarction (MI) in vivo. The proposed optical technique was designed to be an intra-operative guidance tool that can provide useful information about the condition of an infarct for surgeons and researchers. In order to gain insight into the pathophysiological characteristics of an infarct, two novel spectral analysis algorithms were developed to interpret diffuse reflectance spectra. The algorithms were developed based on the unique absorption properties of hemoglobin for the purpose of retrieving regional hemoglobin oxygenation saturation and concentration data in tissue from diffuse reflectance spectra. The algorithms were evaluated and validated using simulated data and actual experimental data. Finally, the hypothesis of the study was validated using a rabbit model of MI. The mechanism by which the MI was induced was the ligation of a major coronary artery of the left ventricle. Three to four weeks after the MI was induced, the extent of myocardial tissue injury and the evolution of the wound healing process were investigated using the proposed spectroscopic methodology as well as histology. The correlations between spectral alterations and histopathological features of the MI were analyzed statistically. The results of this PhD study demonstrate the applicability of the proposed optical methodology for assessing myocardial tissue damage induced by MI in vivo. The results of the spectral analysis suggest that connective tissue proliferation induced by MI significantly alter the characteristics of diffuse reflectance and fluorescence spectra. The magnitudes of the alterations could be quantitatively related to the severity and extensiveness of connective tissue proliferation.
2

Accuracy of semi-infinite diffusion theory to estimate tissue hemodynamics in layered slab models

Sabbir, Md Mainul Hasan 27 July 2021 (has links)
No description available.
3

Développement d’un système de spectroscopie infrarouge résolue temporellement pour la quantification des concentrations d’hémoglobine cérébrale

Leclerc, Paul-Olivier 11 1900 (has links)
L’étude du cerveau humain est un domaine en plein essor et les techniques non-invasives de l’étudier sont très prometteuses. Afin de l’étudier de manière non-invasive, notre laboratoire utilise principalement l’imagerie par résonance magnétique fonctionnelle (IRMf) et l’imagerie optique diffuse (IOD) continue pour mesurer et localiser l’activité cérébrale induite par une tâche visuelle, cognitive ou motrice. Le signal de ces deux techniques repose, entre autres, sur les concentrations d’hémoglobine cérébrale à cause du couplage qui existe entre l’activité neuronale et le flux sanguin local dans le cerveau. Pour être en mesure de comparer les deux signaux (et éventuellement calibrer le signal d’IRMf par l’IOD), où chaque signal est relatif à son propre niveau de base physiologique inconnu, une nouvelle technique ayant la capacité de mesurer le niveau de base physiologique est nécessaire. Cette nouvelle technique est l’IOD résolue temporellement qui permet d’estimer les concentrations d’hémoglobine cérébrale. Ce nouveau système permet donc de quantifier le niveau de base physiologique en termes de concentrations d’hémoglobine cérébrale absolue. L’objectif général de ma maîtrise était de développer un tel système afin de l’utiliser dans une large étude portant sur la condition cardiovasculaire, le vieillissement, la neuroimagerie ainsi que les performances cognitives. Il a fallu tout d’abord construire le système, le caractériser puis valider les résultats avant de pouvoir l’utiliser sur les sujets de recherche. La validation s’est premièrement réalisée sur des fantômes homogènes ainsi qu’hétérogènes (deux couches) qui ont été développés. La validation des concentrations d’hémoglobine cérébrale a été réalisée via une tâche cognitive et appuyée par les tests sanguins des sujets de recherche. Finalement, on présente les résultats obtenus dans une large étude employant le système d’IOD résolue temporellement en se concentrant sur les différences reliées au vieillissement. / Our understanding of the functional organization of the human brain has been greatly influenced by the development of new medical imaging techniques. Pr. Hoge’s research has focused on the use of functional magnetic resonance imaging (fMRI) and continuous diffuse optical imaging (DOI) for non-invasive localization and quantification of brain activity associated with behavioral stimuli or tasks (e.g. cognitive, motor or visual). The respective signals of both techniques are based on cerebral haemoglobin concentrations because of the coupling that exists between neuronal activity and cerebral blood flow. Relating BOLD fMRI signals with those acquired using DOI has been complicated by the fact that fMRI yields fractional change values, while the majority of DOI methods have provided absolute changes from an unknown baseline. To address this, we adopted a newer technique known as time-resolved DOI, which allows absolute quantification of cerebral haemoglobin concentrations. Time-resolved DOI thus has the capacity to quantify the subject’s resting hemoglobin concentrations in absolute micromolar units. The main objective of my masters’ project was to implement and optimize a time-resolved DOI system for use in a large study exploring the links between cardiovascular fitness, aging, neuroimaging markers, and cognitive performance. In this thesis we describe the fabrication of the system, followed by its characterisation and validation using solid optical phantoms (homogeneous and heterogeneous) developed for this purpose. Haemoglobin concentrations obtained non-invasively with the system are validated against blood draws, while the sensitivity to variations in concentration are assessed during a cognitive task. Finally, we present the results of a large study in which the time-resolved DOI system was used to characterize age-related vascular changes in the brain.
4

Développement d’un système de spectroscopie infrarouge résolue temporellement pour la quantification des concentrations d’hémoglobine cérébrale

Leclerc, Paul-Olivier 11 1900 (has links)
L’étude du cerveau humain est un domaine en plein essor et les techniques non-invasives de l’étudier sont très prometteuses. Afin de l’étudier de manière non-invasive, notre laboratoire utilise principalement l’imagerie par résonance magnétique fonctionnelle (IRMf) et l’imagerie optique diffuse (IOD) continue pour mesurer et localiser l’activité cérébrale induite par une tâche visuelle, cognitive ou motrice. Le signal de ces deux techniques repose, entre autres, sur les concentrations d’hémoglobine cérébrale à cause du couplage qui existe entre l’activité neuronale et le flux sanguin local dans le cerveau. Pour être en mesure de comparer les deux signaux (et éventuellement calibrer le signal d’IRMf par l’IOD), où chaque signal est relatif à son propre niveau de base physiologique inconnu, une nouvelle technique ayant la capacité de mesurer le niveau de base physiologique est nécessaire. Cette nouvelle technique est l’IOD résolue temporellement qui permet d’estimer les concentrations d’hémoglobine cérébrale. Ce nouveau système permet donc de quantifier le niveau de base physiologique en termes de concentrations d’hémoglobine cérébrale absolue. L’objectif général de ma maîtrise était de développer un tel système afin de l’utiliser dans une large étude portant sur la condition cardiovasculaire, le vieillissement, la neuroimagerie ainsi que les performances cognitives. Il a fallu tout d’abord construire le système, le caractériser puis valider les résultats avant de pouvoir l’utiliser sur les sujets de recherche. La validation s’est premièrement réalisée sur des fantômes homogènes ainsi qu’hétérogènes (deux couches) qui ont été développés. La validation des concentrations d’hémoglobine cérébrale a été réalisée via une tâche cognitive et appuyée par les tests sanguins des sujets de recherche. Finalement, on présente les résultats obtenus dans une large étude employant le système d’IOD résolue temporellement en se concentrant sur les différences reliées au vieillissement. / Our understanding of the functional organization of the human brain has been greatly influenced by the development of new medical imaging techniques. Pr. Hoge’s research has focused on the use of functional magnetic resonance imaging (fMRI) and continuous diffuse optical imaging (DOI) for non-invasive localization and quantification of brain activity associated with behavioral stimuli or tasks (e.g. cognitive, motor or visual). The respective signals of both techniques are based on cerebral haemoglobin concentrations because of the coupling that exists between neuronal activity and cerebral blood flow. Relating BOLD fMRI signals with those acquired using DOI has been complicated by the fact that fMRI yields fractional change values, while the majority of DOI methods have provided absolute changes from an unknown baseline. To address this, we adopted a newer technique known as time-resolved DOI, which allows absolute quantification of cerebral haemoglobin concentrations. Time-resolved DOI thus has the capacity to quantify the subject’s resting hemoglobin concentrations in absolute micromolar units. The main objective of my masters’ project was to implement and optimize a time-resolved DOI system for use in a large study exploring the links between cardiovascular fitness, aging, neuroimaging markers, and cognitive performance. In this thesis we describe the fabrication of the system, followed by its characterisation and validation using solid optical phantoms (homogeneous and heterogeneous) developed for this purpose. Haemoglobin concentrations obtained non-invasively with the system are validated against blood draws, while the sensitivity to variations in concentration are assessed during a cognitive task. Finally, we present the results of a large study in which the time-resolved DOI system was used to characterize age-related vascular changes in the brain.

Page generated in 0.0983 seconds