21 |
Diretrizes para avaliação do gasto ambiental no ciclo do combustivel nuclear / Guidelines for evaluation of the environmental expense in the nuclear fuel cycleKOMATSU, CINTIA N. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:55:00Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:16Z (GMT). No. of bitstreams: 0 / Este estudo teve como objetivo estabelecer diretrizes para realização da Contabilidade Ambiental no Ciclo do Combustível Nuclear, tendo como estudo de caso a Unidade de Produção de Hexafluoreto de Urânio do Centro Tecnológico da Marinha em São Paulo. A ciência contábil, em sua vertente Contabilidade Ambiental, fornece um conjunto de ferramentas aptas a mensurar os esforços de proteção, conservação, recuperação e monitoramento do meio ambiente na etapa de Conversão, que vai do concentrado de urânio, o yellow cake, até a fabricação do hexafluoreto de urânio. Foram realizadas pesquisas, visitas, levantamento do banco de dados, entrevistas e consultas ao Relatório Preliminar de Análise de Segurança para se obter o porcentual dos gastos relativos à preservação ambiental que a unidade estudada investiu em relação ao total do gasto do empreendimento. E também foi realizada a valoração da área verde preservada, sendo possível o levantamento do Balanço Ambiental. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
22 |
Gestão do conhecimento organizacional através da identificação e análise das competências essenciais: o caso USEXA / Organizational knowledge management through the identification and analysis of core competences: USEXA, a case studyBEDIA, CARLOS E.M. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:18Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:09Z (GMT). No. of bitstreams: 1
12756.pdf: 6246107 bytes, checksum: 2eff5c5908c569b58cddb3095e01ad98 (MD5) / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP
|
23 |
Quantitative mass spectrometric determination of trace impurities in uranium hexafluoride using relative response factorsSowden, Miles January 1993 (has links)
A method has been developed that uses uranium hexafluoride as the
internal standard to quantitatively determine trace impurities in the
uranium hexafluoride using relative response factors. A computer
program was written to control the mass spectrometer and determine
the concentrations of target impurities present. Overlapping spectra are
deconvoluted using the Gauss-Seidel iterative method. The composition
of the sample is determined by comparing the peak height ratios of the
target impurities to the internal standard.
Measurement parameters are easily modified using the menu driven
program. A flexible database allows the list of target impurities to be
extended to accommodate any changes in analytical requirements. The
method has been adapted for automatic on-line measurements.
The technique was evaluated by analysing a number of carefully
prepared standards. Nine target impurities were studied which ranged
in concentration from parts per million to percentages. An overall
precision of fifteen percent was obtained. / Dissertation (MSc)--University of Pretoria, 1993. / gm2013 / Chemistry / unrestricted
|
24 |
Electrical discharges in SF. [i.e. sulphur hexafluoride] as a function of electrode configuration and pressureEteiba, Mahmoud B. January 1977 (has links)
No description available.
|
25 |
Methodology to quantify leaks in aerosol sampling system componentsVijayaraghavan, Vishnu Karthik 15 November 2004 (has links)
Filter holders and continuous air monitors (CAMs) are used extensively in the nuclear industry. It is important to minimize leakage in these devices and in recognition of this consideration, a limit on leakage for sampling systems is specified in ANSI/HPS N13.1-1999; however the protocol given in the standard is really germane to measurement of significant leakage, e.g., several percent of the sampling flow rate. In the present study, a technique for quantifying leakage was developed and that approach was used to measure the sealing integrity of a CAM and two kinds of filter holders. The methodology involves use of sulfur hexafluoride as a tracer gas with the device being tested operated under dynamic flow conditions. The leak rates in these devices were determined in the pressure range from 2.49 kPa (10 In. H2O) vacuum to 2.49 kPa (10 In. H2O) pressure at a typical flow rate of 56.6 L/min (2 cfm). For the two filter holders, the leak rates were less than 0.007% of the nominal flow rate. The leak rate in the CAM was less than 0.2% of the nominal flow rate. These values are well within the limit prescribed in the ANSI standard, which is 5% of the nominal flow rate. Therefore the limit listed in the ANSI standard should be reconsidered as lower values can be achieved, and the methodology presented herein can be used to quantify lower leakage values in sample collectors and analyzers. A theoretical analysis was also done to determine the nature of flow through the leaks and the amount of flow contribution by the different possible mechanisms of flow through leaks.
|
26 |
Methodology to quantify leaks in aerosol sampling system componentsVijayaraghavan, Vishnu Karthik 15 November 2004 (has links)
Filter holders and continuous air monitors (CAMs) are used extensively in the nuclear industry. It is important to minimize leakage in these devices and in recognition of this consideration, a limit on leakage for sampling systems is specified in ANSI/HPS N13.1-1999; however the protocol given in the standard is really germane to measurement of significant leakage, e.g., several percent of the sampling flow rate. In the present study, a technique for quantifying leakage was developed and that approach was used to measure the sealing integrity of a CAM and two kinds of filter holders. The methodology involves use of sulfur hexafluoride as a tracer gas with the device being tested operated under dynamic flow conditions. The leak rates in these devices were determined in the pressure range from 2.49 kPa (10 In. H2O) vacuum to 2.49 kPa (10 In. H2O) pressure at a typical flow rate of 56.6 L/min (2 cfm). For the two filter holders, the leak rates were less than 0.007% of the nominal flow rate. The leak rate in the CAM was less than 0.2% of the nominal flow rate. These values are well within the limit prescribed in the ANSI standard, which is 5% of the nominal flow rate. Therefore the limit listed in the ANSI standard should be reconsidered as lower values can be achieved, and the methodology presented herein can be used to quantify lower leakage values in sample collectors and analyzers. A theoretical analysis was also done to determine the nature of flow through the leaks and the amount of flow contribution by the different possible mechanisms of flow through leaks.
|
27 |
Photoisomérisation du cis-butène-2 sensibilisée par l'hexafluorure de soufre /Gagnon-Deslauriers, Hélène. January 1975 (has links)
Mémoire (M.Sc.)- Université du Québec à Chicoutimi, 1975. / "Thèse présentée dans le cadre du programme UQ d'études avancées en énergie pour l'obtention du grade de la maîtrise es science (énergie)". CaQCU Document électronique également accessible en format PDF. CaQCU
|
28 |
Diretrizes para implantação de um sistema de gestão ambiental no ciclo do combustível nuclear: estudo de caso da USEXA-CEA / Quidelines for implementation of an environmental management system in the nuclear fuel cycle: a case study of USEXA-CEAMATTIOLO, SANDRA R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:33Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:01Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
29 |
Descomissionamento de uma usina de producao de hexafluoreto de uranio / Uranium hexafluoride production plant decommissioningSANTOS, IVAN 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:55:29Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:54Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
30 |
Diagnóstico e sugestões para a gestão do conhecimento aplicada a uma instalação nuclear: a unidade de produção de hexafluoreto de urânio / Diagnosis and suggestions for the knowledge management applied to a nuclear installation: the uranium hexafluoride production unitMARCHESINI, PAULO R. de A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:43Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:22Z (GMT). No. of bitstreams: 1
12787.pdf: 6588986 bytes, checksum: a3586e859638aca4e1c3dc8d0f2d914b (MD5) / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP
|
Page generated in 0.0371 seconds